995 resultados para absorption measurement
Resumo:
The thesis provides an overall review and introduction to amorphous semiconductors, followed by a brief discussion on the important structural models proposed for chalcogenide glasses and their electrical, optional and thermal properties. It also gives a brief description of the Physics of thin films, ion implantation and Photothermal Deflection Spectroscopy. A brief description of the experimental setup of a photothermal deflection spectrometer and the details of the preparation and optical characterization of the thin film samples. It deals with the employment of the subgap optional absorption measurement by PDS to characterize the defects, amorphization and annealing behavior in silicon implanted with B+ ions and the profiles of ion range and vacancy distribution obtained by the TRIM simulation. It reports the results of all absorption measurements by PDS in nitrogen implanted thin film samples of Ge-Se and As-Se systems
Resumo:
Scattering and absorption by aerosol in anthropogenically perturbed air masses over Europe has been measured using instrumentation flown on the UK’s BAe-146-301 large Atmospheric Research Aircraft (ARA) operated by the Facility for Airborne Atmospheric Measurements (FAAM) on 14 flights during the EUCAARI-LONGREX campaign in May 2008. The geographical and temporal variations of the derived shortwave optical properties of aerosol are presented. Values of single scattering albedo of dry aerosol at 550 nm varied considerably from 0.86 to near unity, with a campaign average of 0.93 ± 0.03. Dry aerosol optical depths ranged from 0.030 ± 0.009 to 0.24 ± 0.07. An optical properties closure study comparing calculations from composition data and Mie scattering code with the measured properties is presented. Agreement to within measurement uncertainties of 30% can be achieved for both scattering and absorption,but the latter is shown to be sensitive to the refractive indices chosen for organic aerosols, and to a lesser extent black carbon, as well as being highly dependent on the accuracy of the absorption measurements. Agreement with the measured absorption can be achieved either if organic carbon is assumed to be weakly absorbing, or if the organic aerosol is purely scattering and the absorption measurement is an overestimate due to the presence of large amounts of organic carbon. Refractive indices could not be inferred conclusively due to this uncertainty, despite the enhancement in methodology compared to previous studies that derived from the use of the black carbon measurements. Hygroscopic growth curves derived from the wet nephelometer indicate moderate water uptake by the aerosol with a campaign mean f (RH) value (ratio in scattering) of 1.5 (range from 1.23 to 1.63) at 80% relative humidity. This value is qualitatively consistent with the major chemical components of the aerosol measured by the aerosol mass spectrometer, which are primarily mixed organics and nitrate and some sulphate.
Resumo:
In the present work, we report the growth of wurtzite InN epilayers on GaN/Si (1 1 1) substrate by plasma-assisted molecular beam epitaxy (PAMBE). The growth parameters such as indium flux, substrate temperature and RF power affect the crystallographic and morphological properties of InN layers, which were evaluated using high resolution X-ray diffraction (HRXRD) analysis and atomic force microscopy (AFM). It is found that excess indium (In) concentrations and surface roughness were increased with increase in In flux and growth temperature. The intensity of HRXRD (0 0 0 2) peak, corresponding to c-axis orientation has been increased and full width at half maxima (FWHM) has decreased with increase in RF power. It was found that highly c-axis oriented InN epilayers can be grown at 450 degrees C growth temperature, 450 W RF power and 1.30 x 10(-7) mbar In beam equivalent pressure (BEP). The energy gap of InN layers grown by optimizing growth conditions was determined by photoluminescence and optical absorption measurement. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
差分吸收法是进行瓦斯远距离监测的重要方法,根据瓦斯在近红外波段的吸收特性,报道了一种新型的远距离光纤瓦斯传感系统。采用1.3μm超辐射发光二极管为光源,利用光纤布拉格光栅(FBG)优良的窄带滤波特性实现了对瓦斯的差分吸收测量。和传统的干涉滤光片相比,光纤光栅滤波器插入损耗低、制备简单。系统具有全光纤化、结构简单、工作距离远、稳定性好的特点。工作距离10km,测量灵敏度为0.1%,是瓦斯爆炸极限的2%。
Resumo:
为提高表面热透镜薄膜吸收测量仪的灵敏度,在表面热透镜衍射理论基础上,通过数值模拟给出了探测激光腰斑半径、探测激光腰斑到样品表面距离、样品到探测光纤端面距离等仪器参数的优化方法.经优化调整后该仪器能达到优于0.1ppm量级的薄膜吸收率测量灵敏度.
Resumo:
由薄膜表面光热形变简化理论和表面热透镜衍射理论导出表面热透镜信号表达式,从理论上证明了表面热透镜信号和薄膜吸收率的线性关系.应用表面热透镜技术研制了薄膜吸收测量仪,测量结果表明其吸收率测量灵敏度和精度均达10-6量级.
Resumo:
The laser-induced damage (LID) behavior of narrow-band interference filters was investigated with a Nd:YAG laser at 1064 nm under single-pulse mode and free-running mode. The absorption measurement of such coatings was performed with surface thermal lensing (STL) technique. The damage morphologies under the two different laser modes were also studied in detail. It was found that all the filters exhibited a pass-band-center-dependent absorption and laser-induced damage threshold (LIDT) behavior, but the damage morphologies were diverse. The explanation was given with the analysis of the electric field distribution and the operational behavior of the irradiation laser. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
研究了Ta2O5/SiO2硬膜双腔干涉滤光片带内、带边及带外的吸收和激光损伤特性。实验发现,对于作用激光,带通滤光片的驻波场分布、吸收率和损伤阈值在带内、带边和带外的响应特性对作用激光波长均呈现出明显的选择性。根据实验结果,结合滤光片的驻波场分析,给出了带通滤光片的损伤机理。
Resumo:
The density of metastable helium atoms in a dielectric barrier discharge operating in helium with some impurities present has been measured using laser-collisional-induced fluorescence and absorption techniques. Time-resolved measurements indicate that helium metastables contribute to the production of impurity ions, in this case N-2(+), in the postdischarge current phase of a glow discharge. In our particular discharge environment, the helium metastable density is (1.5+/-1.4)x10(10) cm(-3), a result consistent with failure to observe absorption by metastables in a multipass absorption measurement. (C) 2004 American Institute of Physics.
Resumo:
Polyfluorene end-capped with N-(2-benzothiazole)-1 8-naphthalimide (PF-BNI) is a highly fluorescent material with fluorescence emission modulated by solvent polarity Its low energy excited state is assigned as a mixed configuration state between the singlet S(1) of the fluorene backbone (F) with the charge transfer (CI) of the end group BNI The triexponential fluorescence decays of PF-BNI were associated with fast energy migration to form an intrachain charge-transfer (ICCT) state polyfluorene backbone decay and ICCT deactivation Time-resolved fluorescence anisotropy exhibited biexponential relaxation with a fast component of 12-16 ps in addition to a slow one in the range 0 8-1 4 ns depending on the solvent showing that depolarization occurs from two different processes energy migration to form the ICCT state and slow rotational diffusion motion of end segments at a longer time Results from femtosecond transient absorption measurements agreed with anisotropy decay and showed a decay component of about 16 ps at 605 nm in PF BNI ascribed to the conversion of S(1) to the ICCT excited state From the ratio of asymptotic and initial amplitudes of the transient absorption measurement the efficiency of intrachain ICCT formation is estimated in 0 5 which means that on average, half of the excited state formed in a BNI-(F)(n)-BNI chain with n = 32 is converted to its low energy intrachain charge-transfer (ICCT) state
Resumo:
Aims: Darunavir is widely used in HIV/AIDS therapy. It is a HIV protease inhibitor that has excellent efficacy against the virus. The aim of this study is to develop and validate an analytical method fast and free of interferences for determination of darunavir ethanolate as raw material and tablet dosage form. Methodology: As the formulation excipients show high interference in darunavir determination by a direct UV absorption measurement a derivative spectrophotometry was applied. A selective, easy and fast method was achieved employing simple and cheap instrumentation by using first-order derivative spectrophotometry. Results: The first-derivation of spectrum of the drug measured between 200 and 400 nm allowed identification of the analyte and showed absence of placebo interference. The assay was based on the absorbance at 276nm. The linear concentration range was established from 11 to 21 μg/mL. The intra-day and inter-day precision expressed as RSD was 0.06% and 3.75% respectively with mean recovery of 99.84%. Conclusion: The proposed analytical method is able to quantify darunavir as raw material and tablets and can be used routinely by any laboratory applying a spectrophotometer with a derivative accessory. The great difference of the method proposed here is that it proves to be free of placebo interferences as well as simple, fast and low cost.
Resumo:
Zusammenfassung Im Rahmen dieser Arbeit wurden grundlegende Aspekte der Photomodulation der Aktivität von Biomolekülen behandelt. Im ersten Teil der Arbeit wurde ein Weg ausgearbeitet, photochrome Indolinospirobenzopyrane kovalent an Immunoglobulin G zu koppeln. Dazu wurde ein vollständig wässriges Verfahren entwickelt, was die Synthese eines noch nicht in der Literatur beschriebenen wasserlöslichen und gleichzeitig zur Kopplung befähigten Indolinospirobenzopyrans voraussetzte. Der zweite Teil der Arbeit beschäftigte sich mit der spektroskopischen Charakterisierung einer Reihe von photochromen Indolinospirobenzopyranen. Zur Untersuchung der Kinetik des Schaltprozesses wurde die zeitaufgelöste, transiente Absorptionsspektroskopie eingesetzt. Die erhaltenen Daten wurden vor dem Hintergrund von in der Literatur postulierten Schaltmechanismen kontrovers diskutiert. Darüber hinaus wurden mit Hilfe der elektrooptischen Absorptionsmessung die Dipolmomente im Grundzustand und im ersten angeregten Zustand für eine Reihe von Indolinospirobenzopyranen bestimmt. Zur Durchführung der Messungen wurde die bestehende Apparatur zu Messung von photochromen Verbindungen im photostationären Gleichgewicht erweitert. Erwartungsgemäß wurden für die Merocyaninformen sehr große Dipolmomente um 18 Debye gefunden. Das Dipolmoment im ersten angeregten Zustand betrug dagegen nur etwa 12 Debye. Im Fall der Spiroformen war das Dipolmoment im Grundzustand klein (3-5 Debye), während es im ersten angeregten Zustand auf etwa 20 D anstieg.
Resumo:
In dieser Arbeit wird zum Erreichen hoher Kernspinpolarisationen die Methode des metastabilen optischen Pumpens benutzt. Das Verfahren beruht auf dem "Ubertrag des Drehimpulses absorbierter Photonen auf das hierbei angeregte Valenzelektron, welches durch Hyperfeinkopplung den Drehimpuls weiter auf den $^3$He-Kern transferiert. Da der Polarisationsprozess nur bei Dr"ucken von ca. 1~mbar effizient funktioniert, f"ur die meisten Anwendungen aber polarisiertes $^3$He bei einem Druck von $geq 1$~bar ben"otigt wird, muss das Gas nach der Aufpolarisation komprimiert werden. In unserer Arbeitsgruppe steht eine Maschine ("`Polarisator"') zur Verf"ugung, die das Gas polarisiert und anschlie"send komprimiert. Ziel dieser Dissertation ist, einerseits die Leistungsf"ahigkeit des Polarisators bez"uglich Maximalpolarisation und Gasfluss zu verbessern und andererseits den metastabilen Pumpprozess selbst genauer zu untersuchen.\ noindent Durch die Verwendung neuer Laser auf Basis der Fasertechnologie sowie einer systematischen Optimierung der optischen Komponenten konnten in abgeschlossenen Pumpzellen Rekord-Polarisationsgrade von $91pm 2$% erzielt werden.\ noindent Mit der Implementierung neuartiger Optiken und Laser am Mainzer Polarisator konnte die Leistungscharakteristik entscheidend verbessert werden. So wurde die erreichbare Polarisation bei identischer Produktionsrate um 20 Prozentpunkte gesteigert. Zurzeit sind maximale Polarisationsgrade von mehr als 75% im optischen Pumpvolumen erreichbar. Eine am Mainzer Triga-Reaktor durchgef"uhrte Polarisationsbestimmung ergab einen Wert von $72.7pm 0.7$%. Dies veranschaulicht die geringen Polarisationsverluste infolge der Gaskompression, des Transports und einer Lagerung "uber mehrere Stunden.\ noindent Zur Dynamik der geschwindigkeitsver"andernden St"o"se sowie zur Bestimmung der mittleren Photonen-Absorptionsrate wurde ein Modell entwickelt, welches auch experimentell best"atigt wurde. Damit konnte erstmalig das gemessene Absorptionsverhalten einer spektral schmalbandigen Laserdiode korrekt beschrieben werden.\ noindent Zudem stimmen die an so genannten abgeschlossenen Pumpzellen gemessenen extrem hohen Polarisationswerte mit theoretischen Vorhersagen "uberein, sofern der Druck im optischen Pumpvolumen geringer als 1~mbar ist und das $^3$He nicht durch Fremdgase verunreinigt ist. Bei derartigen Pumpzellen ist die gemessene Abh"angigkeit der Polarisation von Laserleistung, Metastabilendichte und falscher Zirkularkomponente mit der Theorie kompatibel.\
Resumo:
The wet bulk density is one of the most important parameters of the physical and geological properties of marine sediments. The density is connected directly with sedimentation history and a few sedirnent properties. Knowledge of the fine scale density-depth structure is the base for many model calculations, for both sedimentological and palaeoclimatic research. A density measurement system was designed and built at the Alfred Wegener Institute in Bremerhaven for measuring the wet buk density of sediment cores with high resolution in a non-destructive way. The density is deterrnined by measuring the absorption of Gamma-rays in the sediment. This principle has been used since the 50's in materials research and in the geosciences. In the present case, Cs137 is used as the radioactive source and the intensity is measured by a detector system (scintillator and photomultiplier). Density values are obtainable in both longitudinal core sections and planar cross-sections (the latter are a function of the axial rotation angle). Special studies on inhomogenity can be applied with core rotation. Detection of ice rafted debris (IRD) is made possible with this option. The processes that run the density measurement system are computer controlled. Besides the absorption measurement the core diameter at every measurement point is determined with a potentiometric system. The data values taken are stored on a personal computer. Before starting routine measurements on the sediment cores, a few experiments conceming the statistical aspects of the gamma-ray signal and its accuracy were carried out. These experiments led to such things as the optimum operational parameters. A high spatial resolution in the mm-range is possible with the 4mm-thin gamma-ray measurements. Within five seconds the wet bulk density can be deterrnined with an absolute accuracy of 1%. A comparison between data measured with the new system and conventional measurements on core samples after core splitting shows an agreement within +I- 5% for most of the values. For this thesis, density determinations were carried out on ten sediment cores. A few sediment characteristics are obtainable from using just the standard measurement results without core rotation. In addition to differentes and steps in the absolute density range, variations in the "frequency" of the density-depth structure can be detected due to the close spatial measurement interval and high resolution. Examples from measurements with small (9°) and great (90°) angle increments show that abrupt and smooth transitional changes of sedirnent layers as well as ice rafted debris of several dimensions can be detected and distiflguished clearly. After the presentation of the wet bulk density results, a comparison with data from other investigations was made. Measurements of the electrical resistivity correlated very well with the density data because both parameters are closely related to the porosity of the sedirnent. Additionally, results from measurements of the magnetic susceptibility and from ultra-sonic wave velocity investigations were considered for a integrative interpretation. The correlation of these both parameters and wet bulk density data is strongly dependent on the local (environmental) conditions. Finally, the densities were compared with recordings from sediment-echographic soundings and an X-ray computer tomography analysis. The individual results of all investigations were then finally combined into an accurate picture of the core. Problems of ambiguity, which exist when just one Parameter is determined alone, can be reduced more or less according to the number of parameters and sedimentary characteristics measured. The important role of the density data among other parameters of such an integrated interpretation is evident. Evidence of this role include the high resolution of the measurement, the excellent accuracy and the key position within methods and parameters concerning marine sediments.