998 resultados para a- cyano -4- hydroxycinnamic


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The monoconjugates of phenolic acids (i.e. coumaric acid) with polyamines such as spermidine and spermine are strikingly similar to some toxins from spiders and predatory wasps. Many plants contain phenolic acid polyamine conjugates and there is some reliable information supporting their roles as plant defense chemicals. Eleven monoacylated compounds of diamines, triamines, tetraamines and oxa-polyamine amines were prepared in three to seven steps: 22, 23, 24, 25, 26, 27, 28, 29, 30, 31 and 32. The synthesis proceeds through stepwise construction of the polyamine backbone (as in 62 and 72), followed by protection and deprotection steps of the amino functions. Desymmetrization of readily available and prepared symmetrical polyamines is a key step in the synthesis. The protecting groups employed were tert-butoxycarbonyl (BOC) and trifluoroacetyl (TFA) group which were removed under different conditions: acid and base respectively. Deprotection and refunctionalization of the polyamine reagent demonstrated the versatility of these systems for N-acylation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Matrix-assisted laser desorption/ionization (MALDI) is a key ionization technique in mass spectrometry (MS) for the analysis of labile macromolecules. An important area of study and improvements in relation to MALDI and its application in high-sensitivity MS is that of matrix design and sample preparation. Recently, 4-chloro-alpha-cyanocinnamic acid (ClCCA) has been introduced as a new rationally designed matrix and reported to provide an improved analytical performance as demonstrated by an increase in sequence coverage of protein digests obtained by peptide mass mapping (PMM) (Jaskolla, T. W.; et al. Proc. Natl. Acad. Sci. U.S.A. 2008, 105, 12200-12205). This new matrix shows the potential to be a superior alternative to the commonly used and highly successful alpha-cyano-4-hydroxycinnamic acid (CHCA). We have taken this design one step further by developing and optimizing an ionic liquid matrix (ILM) and liquid support matrix (LSM) using ClCCA as the principle chromophore and MALDI matrix compound. These new liquid matrices possess greater sample homogeneity and a simpler morphology. The data obtained from our studies show improved sequence coverage for BSA digests compared to the traditional CHCA crystalline matrix and for the ClCCA-containing ILM a similar performance to the ClCCA crystalline matrix down to 1 fmol of BSA digest prepared in a single MALDI sample droplet with current sensitivity levels in the attomole range. The LSMs show a high tolerance to contamination such as ammonium bicarbonate, a commonly used buffering agent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Genotoxicity data on commercial azo dyes and their components remain sparse, despite their widespread use. We have tested the mutagenicity of 2-cyano-4-nitroaniline (CNNA) and 2,6-dicyano-4-nitroaniline (CNCNNA), components of azo dyes such as Disperse Blue 165 and Disperse Red 73, in Ames test strains. Both compounds are extraordinarily potent frameshift mutagens, with much greater activity than structurally similar dihalonitroanilines and halodinitroanilines. Analysis of the responses of strains over-expressing or deficient in bioactivation enzymes shows that bacterial nitroreductase and acetyl CoA: arylamine N-acetyltransferase are important mediators of the mutagenicity of CNNA and CNCNNA. Environ. Mol. Mutagen., 2015. © 2015 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ftalocianina de alumínio-cloro (AlClPc) é um fotossensibilizador de segunda geração em terapia fotodinâmica (TFD) caracterizado por seu caráter anfifílico e tendência de auto-agregação em meio aquoso, o que prejudica seu potencial de aplicação. O aCHC é um substrato de transportadores de monocarboxilato (MCT) superexpresso em células de MCF-7. Objetivando a solubilização da AlClPc e aumento de internalização em tecidos neoplásicos nos propomos aqui o uso de DSPC e DOPC em diferentes proporções para formar vesículas lipidicas mistas (LV) na presença de aCHC como sistemas veiculadores de fármaco. Lv foi preparado pelo método de injeção etanólica e formou vesículas de dimensões nanométricas (aproximadamente 100 nm) com bom índice de polidispersão, valores negativos de potencial zeta e estáveis em meio aquoso por mais de 50 dias. AlClPc se complexou com o fosfato das LV o que conferiu uma localização interfacial às moléculas de AlClPc como demonstrado pelos resultados de supressão de fluorescência. Medidas de anisotropia, fluorescência estática e resolvida no tempo corroboram com estes resultados e demonstram que a auto-agregação da AlClPc ocorre mesmo em lipossomas. Entretanto, a veiculação da AlClPc por LV em carcinoma de células escamosas oral (OSCC) levou a um processo de desagregação demonstrado por (FLIM). Este incrível comportamento é novo e aumenta o conhecimento científico sobre o mecanismo intracelular de ação de fotossensibilizadores em TFD. Em TFD, ambos os sistemas LVIII+AlClPc e LVIII+AlClPc+aCHC não apresentaram toxicidade no escuro no período de incubação de 3 h com as concentrações de lipídios, AlClPc e aCHC iguais a 0,15 mmol/L, 0,5 umol/L e 10,0 umol/L, respectivamente. De maneira inesperada, o sistema LVIII+AlClPc foi mais eficiente em TFD que o sistema LVIII+AlClPc+aCHC, devido ao caráter antioxidante do aCHC. Estes resultados abrem uma nova perspectiva do potencial uso de LV-AlClPc para o tratamento fotodinâmico.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A dry matrix application for matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI MSI) was used to profile the distribution of 4-bromophenyl-1,4-diazabicyclo(3.2.2)nonane-4-carboxylate, monohydrochloride (BDNC, SSR180711) in rat brain tissue sections. Matrix application involved applying layers of finely ground dry alpha-cyano-4-hydroxycinnamic acid (CHCA) to the surface of tissue sections thaw mounted onto MALDI targets. It was not possible to detect the drug when applying matrix in a standard aqueous-organic solvent solution. The drug was detected at higher concentrations in specific regions of the brain, particularly the white matter of the cerebellum. Pseudomultiple reaction monitoring imaging was used to validate that the observed distribution was the target compound. The semiquantitative data obtained from signal intensities in the imaging was confirmed by laser microdissection of specific regions of the brain directed by the imaging, followed by hydrophilic interaction chromatography in combination with a quantitative high-resolution mass spectrometry method. This study illustrates that a dry matrix coating is a valuable and complementary matrix application method for analysis of small polar drugs and metabolites that can be used for semiquantitative analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a novel method termed matrix suppressed laser desorption/ionization to improve the analysis of low-mass molecules by MALDI-TOF mass spectrometry. In this method, the surfactant of cetrimonium bromide (CTAB) is added to the conventional matrix of alpha-cyano-4-hydroxycinnamic acid solution to prepare the MALDI samples. During the MALDI process, the presence of CTAB could substantially or even completely suppress the matrix-related ion background. As a result, very clean mass spectra can be routinely obtained in the low-mass range. In addition, the presence of CTAB can significantly improve the mass resolution of low-mass molecules. It is seen that high-quality spectra were routinely obtained at a matrix/CTAB ratio of 1000:1. This method has been successfully used to analyze a variety of low-mass molecules.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and high-throughput method for the identification of disulfide-containing peptides utilizing peptide-matrix adducts is described. Some commonly used matrices in MALDI mass spectrometry were found to specifically react with sulfhydryl groups within peptide, thus allowing the observation of the peptide-matrix adduct ion [M + n + n' matrix + H](+) or [M + n + n' matrix + Na](+) (n = the number of cysteine residues, n' = 1, 2, ..., n) in MALDI mass spectra after chemical reduction of disulfide-linked peptides. Among several matrices tested, alpha-cyano-4-hydroxycinnamic acid (CHCA, molecular mass 189 Da) and alpha-cyano-3-hydroxycinnamic acid (3-HCCA) were found to be more effective for MALDI analysis of disulfide-containing peptides/proteins. Two reduced cysteines involved in a disulfide bridge resulted in a mass shift of 189 Da per cysteine, so the number of disulfide bonds could then be determined, while for the other matrices (sinapinic acid, ferulic acid, and caffeic acid), a similar addition reaction could not occur unless the reaction was carried out under alkaline conditions. The underlying mechanism of the reaction of the matrix addition at sulfhydryl groups is proposed, and several factors that might affect the formation of the peptide-matrix adducts were investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A matrix-assisted laser desorption ionization time-of-flight mass spectrometry(MALDI-TOF—MS) technique was used for analysis of moleculear weight of cytochrome C.The effects of three kinds of matrix,such as 2,5-dihydroxybenzoic acid(DHB),a-cyano-4-hydroxycinnamic acid(a-CHC) and sinapinic acid(SA),were used to compared and a suitable a-CHC was found.Experimental data showed that this method was properable to analysis of the congeneric biochemical samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oxidized carbon nanotubes are tested as a matrix for analysis of small molecules by matrix assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS). Compared with nonoxidized carbon nanotubes, oxidized carbon nanotubes facilitate sample preparation because of their higher solubility in water. The matrix layer of oxidized carbon nanotubes is much more homogeneous and compact than that of nonoxidized carbon nanotubes. The efficiency of desorption/ionization for analytes and the reproducibility of peak intensities within and between sample spots are greatly enhanced on the surface of oxidized carbon nanotubes. The advantage of the oxidized carbon nanotubes in comparison with alpha-cyano-4-hydroxycinnamic acid (CCA) and carbon nanotubes is demonstrated by MALDI-TOF-MS analysis of an amino acid mixture. The matrix is successfully used for analysis of synthetic hydroxypropyl P-cyclodextrin, suggesting a great potential for monitoring reactions and for product quality control. Reliable quantitative analysis of jatrorrhizine and palmatine with a wide linear range (1-100 ng/mL) and good reproducibility of relative peak areas (RSD less than 10 %) is achieved using this matrix. Concentrations of jatrorrhizine (8.65 mg/mL) and palmatine (10.4 mg/mL) in an extract of Coptis chinensis Franch are determined simultaneously using the matrix and a standard addition method. (c) 2005 American Society for Mass Spectrometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The success of Matrix-assisted laser desorption / ionisation (MALDI) in fields such as proteomics has partially but not exclusively been due to the development of improved data acquisition and sample preparation techniques. This has been required to overcome some of the short comings of the commonly used solid-state MALDI matrices such as - cyano-4-hydroxycinnamic acid (CHCA) and 2,5-dihydroxybenzoic acid (DHB). Solid state matrices form crystalline samples with highly inhomogeneous topography and morphology which results in large fluctuations in analyte signal intensity from spot to spot and positions within the spot. This means that efficient tuning of the mass spectrometer can be impeded and the use of MALDI MS for quantitative measurements is severely impeded. Recently new MALDI liquid matrices have been introduced which promise to be an effective alternative to crystalline matrices. Generally the liquid matrices comprise either ionic liquid matrices (ILMs) or a usually viscous liquid matrix which is doped with a UV lightabsorbing chromophore [1-3]. The advantages are that the droplet surface is smooth and relatively uniform with the analyte homogeneously distributed within. They have the ability to replenish a sampling position between shots negating the need to search for sample hot-spots. Also the liquid nature of the matrix allows for the use of additional additives to change the environment to which the analyte is added.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evidence is presented that the performance of the rationally designed MALDI matrix 4-chloro-α-cyanocinnamic acid (ClCCA) in comparison to its well-established predecessor α-cyano-4-hydroxycinnamic acid (CHCA) is significantly dependent on the sample preparation, such as the choice of the target plate. In this context, it becomes clear that any rational designs of MALDI matrices and their successful employment have to consider a larger set of physicochemical parameters, including sample crystallization and morphology/topology, in addition to parameters of basic (solution and/or gas-phase) chemistry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Matrix-assisted laser desorption/ionisation (MALDI) coupled with time-of-flight (TOF) mass spectrometry (MS) is a powerful tool for the analysis of biological samples, and nanoflow high-performance liquid chromatography (nanoHPLC) is a useful separation technique for the analysis of complex proteomics samples. The off-line combination of MALDI and nanoHPLC has been extensively investigated and straightforward techniques have been developed, focussing particularly on automated MALDI sample preparation that yields sensitive and reproducible spectra. Normally conventional solid MALDI matrices such as α-cyano-4-hydroxycinnamic acid (CHCA) are used for sample preparation. However, they have limited usefulness in quantitative measurements and automated data acquisition because of the formation of heterogeneous crystals, resulting in highly variable ion yields and desorption/ ionization characteristics. Glycerol-based liquid support matrices (LSM) have been proposed as an alternative to the traditional solid matrices as they provide increased shot-to-shot reproducibility, leading to prolonged and stable ion signals and therefore better results. This chapter focuses on the integration of the liquid LSM MALDI matrices into the LC-MALDI MS/MS approach in identifying complex and large proteomes. The interface between LC and MALDI consists of a robotic spotter, which fractionates the eluent from the LC column into nanoliter volumes, and co-spots simultaneously the liquid matrix with the eluent fractions onto a MALDI target plate via sheath flow. The efficiency of this method is demonstrated through the analysis of trypsin digests of both bovine serum albumin (BSA) and Lactobacillus plantarum WCFS1 proteins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)