950 resultados para X-rays: bursts


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present high time-resolution multiwavelength observations of X-ray bursts in the low-mass X-ray binary UY Vol. Strong reprocessed signals are present in the ultraviolet and optical, lagged and smeared with respect to the X-rays. The addition of far-ultraviolet coverage for one burst allows much tighter constraints on the temperature and geometry of the reprocessing region than previously possible. A blackbody reprocessing model for this burst suggests a rise in temperatures during the burst from 18,000 to 35,000 K and an emitting area comparable to that expected for the disk and/or irradiated companion star. The lags are consistent with those expected. The single-zone blackbody model cannot reproduce the ratio of optical to ultraviolet flux during the burst, however. The discrepancy seems too large to explain with deviations from a local blackbody spectrum and more likely indicates that a range of reprocessing temperatures are required. Comparable results are derived from other bursts, and in particular the lag and smearing both appear shorter when the companion star is on the near side of the disk as predicted. The burst observed by HST also yielded a spectrum of the reprocessed light. It is dominated by continuum, with a spectral shape consistent with the temperatures derived from lightcurve modeling. Taken as a whole, our observations confirm the standard paradigm of prompt reprocessing distributed across the disk and companion star, with the response dominated by a thermalized continuum rather than by emission lines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Due to the particular characteristics of the fusion products, i.e. very short pulses (less than a few μs long for ions when arriving to the walls; less than 1 ns long for X-rays), very high fluences ( 10 13 particles/cm 2 for both ions and X rays photons) and broad particle energy spectra (up to 10 MeV ions and 100 keV photons), the laser fusion community lacks of facilities to accurately test plasma facing materials under those conditions. In the present work, the ability of ultraintese lasers to create short pulses of energetic particles and high fluences is addressed as a solution to reproduce those ion and X-ray bursts. Based on those parameters, a comparison between fusion ion and laser driven ion beams is presented and discussed, describing a possible experimental set-up to generate with lasers the appropriate ion pulses. At the same time, the possibility of generating X-ray or neutron beams which simulate those of laser fusion environments is also indicated and assessed under current laser intensities. It is concluded that ultraintense lasers should play a relevant role in the validation of materials for laser fusion facilities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ability of ultraintese lasers to create short pulses of energetic particles and high fluences is addressed as a solution to reproduce ion and X-ray ICF bursts for the characterization and validation of plasma facing components. The possibility of using a laser neutron source for material testing will also be discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article describes a project to unwrap an ancient Egyptian mummy using X-ray computed tomography (CT). About 600 X-ray CT images were obtained through the mummified body of a female named Tjetmutjengebtiu (or Jeni for short), who was a singer in the great temple of Karnak in Egypt during the 22nd dynasty (c. 945-715 BC). The X-ray CT images reveal details of the remains of body organs, wrappings and jewellery. 3D reconstructions of Jeni’s teeth suggest that she was probably only around 20 years old when she died, although the cause of death cannot be ascertained from the CT scans. The CT images were used to build a 3D model of Jeni’s head which enabled an artist to paint a picture of what Jeni may have looked like during life. A PowerPoint presentation and movie clips are provided as supplementary material that may be useful for teaching.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Radiological evaluation of the paediatric cervical spine can be a challenge due to the normal anatomic variants and injuries that are unique to children. We aimed to identify the usefulness of plain X-rays in comparison with CT and MRI in diagnosing Paediatric cervical spinal injuries. METHODS Retrospective review of imaging studies of children diagnosed with paediatric cervical spine injuries who had presented to two tertiary hospitals in Queensland. RESULTS There were 38 patients with 18 male and 20 female .The mean age was 8.6 years. Plain Cervical Spine X-rays (3views, AP lateral and open mouth views) were done in 34 patients. The remaining 8 children had a suspected head injury and hence had CT scans of their neck done at the time of CT head scan. Of these images taken, X-rays were diagnostic in 28 (82%) patients. CONCLUSION X- Rays still have a role to play in the diagnosis of pediatric cervical spinal injuries and should be considered as the first line in fully conscious patients and their usefulness should not be overlooked in light of the newer imaging modalities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hydrophobins are a group of particularly surface active proteins. The surface activity is demonstrated in the ready adsorption of hydrophobins to hydrophobic/hydrophilic interfaces such as the air/water interface. Adsorbed hydrophobins self-assemble into ordered films, lower the surface tension of water, and stabilize air bubbles and foams. Hydrophobin proteins originate from filamentous fungi. In the fungi the adsorbed hydrophobin films enable the growth of fungal aerial structures, form protective coatings and mediate the attachment of fungi to solid surfaces. This thesis focuses on hydrophobins HFBI, HFBII, and HFBIII from a rot fungus Trichoderma reesei. The self-assembled hydrophobin films were studied both at the air/water interface and on a solid substrate. In particular, using grazing-incidence x-ray diffraction and reflectivity, it was possible to characterize the hydrophobin films directly at the air/water interface. The in situ experiments yielded information on the arrangement of the protein molecules in the films. All the T. reesei hydrophobins were shown to self-assemble into highly crystalline, hexagonally ordered rafts. The thicknesses of these two-dimensional protein crystals were below 30 Å. Similar films were also obtained on silicon substrates. The adsorption of the proteins is likely to be driven by the hydrophobic effect, but the self-assembly into ordered films involves also specific protein-protein interactions. The protein-protein interactions lead to differences in the arrangement of the molecules in the HFBI, HFBII, and HFBIII protein films, as seen in the grazing-incidence x-ray diffraction data. The protein-protein interactions were further probed in solution using small-angle x-ray scattering. Both HFBI and HFBII were shown to form mainly tetramers in aqueous solution. By modifying the solution conditions and thereby the interactions, it was shown that the association was due to the hydrophobic effect. The stable tetrameric assemblies could tolerate heating and changes in pH. The stability of the structure facilitates the persistence of these secreted proteins in the soil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We study the orbital modulation of X-rays from Cyg X-3, using data from Swift, INTEGRAL and RXTE. Using the wealth of data presently available and an improved averaging method, we obtain energy-dependent folded and averaged light curves with unprecedented accuracy. We find that above similar to 5?keV the modulation depth decreases with increasing energy, which is consistent with the modulation being caused by both boundfree absorption and Compton scattering in the stellar wind of the donor, with minima corresponding to the highest optical depth, which occurs around the superior conjunction. We find a decrease of the depth below similar to 3?keV, which appears to be due to re-emission of the absorbed continuum by the wind in soft X-ray lines. Based on the shape of the folded light curves, any X-ray contribution from the jet in Cyg X-3, which emits ?-rays detected at energies >0.1?GeV in the soft spectral states, is found to be minor up to similar to 100?keV. This implies the presence of a rather sharp low-energy break in the jet MeV-range spectrum. We also calculate phase-resolved RXTE X-ray spectra and show that the difference between the spectra corresponding to phases around superior and inferior conjunctions can indeed be accounted for by the combined effect of boundfree absorption in an ionized medium and Compton scattering.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

X-ray phase imaging with illumination by a partially coherent source with a setup similar to in-line holography is considered. Using the optical transform function, we consider the effects of partial coherence on this x-ray phase imaging for a weak phase object. The optimal contrast and the resolution of phase imaging are analyzed. As the coherence decreases, the imaging contrast and the optimal contrast frequency decrease, and the resolution degrades. It is shown that this contrast-enhanced phase-imaging method can be regarded as a linear bandpass filter and that the bandwidth and the image contrast are changeable. The frequency property of the imaging system can be improved if an incoherent x-ray source with the proper shape is used. (C) 1999 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electronic Kαl x-ray isotope shifts have been measured for Sn 116-124, Sm 148-154, W 182-184, W 184-186, and W 182-186 using a curved crystal Cauchois spectrometer. The analysis of the measurements has included the electrostatic volume effect, screening by the transition electron as well as the non-transition electrons, normal and specific mass shifts, dynamical nuclear qudrupole polarization, and a radiative correction effect of the electron magnetic moment in the nuclear charge radii are obtained. Where other experimental data are available, the agreement with the present measurements is satisfactory. Comparisons with several nuclear model predictions yield only partial agreement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The basic elements of Bragg-Fresnel multilayer optics are multilayer gratings. In this paper, the fabrication process for the simplest Bragg-Fresnel multilayer optics is given; the diffraction measurements at 8-keV x rays of multilayer gratings are presented; and the measurement results in the diffraction spectrum are analyzed and discussed in detail. (C) 1996 Society of Photo-Optical Instrumentation Engineers.