904 resultados para Wireless data transfer


Relevância:

100.00% 100.00%

Publicador:

Resumo:

For wireless power transfer (WPT) systems, communication between the primary side and the pickup side is a challenge because of the large air gap and magnetic interferences. A novel method, which integrates bidirectional data communication into a high-power WPT system, is proposed in this paper. The power and data transfer share the same inductive link between coreless coils. Power/data frequency division multiplexing technique is applied, and the power and data are transmitted by employing different frequency carriers and controlled independently. The circuit model of the multiband system is provided to analyze the transmission gain of the communication channel, as well as the power delivery performance. The crosstalk interference between two carriers is discussed. In addition, the signal-to-noise ratios of the channels are also estimated, which gives a guideline for the design of mod/demod circuits. Finally, a 500-W WPT prototype has been built to demonstrate the effectiveness of the proposed WPT system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A wide range of non-destructive testing (NDT) methods for the monitoring the health of concrete structure has been studied for several years. The recent rapid evolution of wireless sensor network (WSN) technologies has resulted in the development of sensing elements that can be embedded in concrete, to monitor the health of infrastructure, collect and report valuable related data. The monitoring system can potentially decrease the high installation time and reduce maintenance cost associated with wired monitoring systems. The monitoring sensors need to operate for a long period of time, but sensors batteries have a finite life span. Hence, novel wireless powering methods must be devised. The optimization of wireless power transfer via Strongly Coupled Magnetic Resonance (SCMR) to sensors embedded in concrete is studied here. First, we analytically derive the optimal geometric parameters for transmission of power in the air. This specifically leads to the identification of the local and global optimization parameters and conditions, it was validated through electromagnetic simulations. Second, the optimum conditions were employed in the model for propagation of energy through plain and reinforced concrete at different humidity conditions, and frequencies with extended Debye's model. This analysis leads to the conclusion that SCMR can be used to efficiently power sensors in plain and reinforced concrete at different humidity levels and depth, also validated through electromagnetic simulations. The optimization of wireless power transmission via SMCR to Wearable and Implantable Medical Device (WIMD) are also explored. The optimum conditions from the analytics were used in the model for propagation of energy through different human tissues. This analysis shows that SCMR can be used to efficiently transfer power to sensors in human tissue without overheating through electromagnetic simulations, as excessive power might result in overheating of the tissue. Standard SCMR is sensitive to misalignment; both 2-loops and 3-loops SCMR with misalignment-insensitive performances are presented. The power transfer efficiencies above 50% was achieved over the complete misalignment range of 0°-90° and dramatically better than typical SCMR with efficiencies less than 10% in extreme misalignment topologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A wide range of non-destructive testing (NDT) methods for the monitoring the health of concrete structure has been studied for several years. The recent rapid evolution of wireless sensor network (WSN) technologies has resulted in the development of sensing elements that can be embedded in concrete, to monitor the health of infrastructure, collect and report valuable related data. The monitoring system can potentially decrease the high installation time and reduce maintenance cost associated with wired monitoring systems. The monitoring sensors need to operate for a long period of time, but sensors batteries have a finite life span. Hence, novel wireless powering methods must be devised. The optimization of wireless power transfer via Strongly Coupled Magnetic Resonance (SCMR) to sensors embedded in concrete is studied here. First, we analytically derive the optimal geometric parameters for transmission of power in the air. This specifically leads to the identification of the local and global optimization parameters and conditions, it was validated through electromagnetic simulations. Second, the optimum conditions were employed in the model for propagation of energy through plain and reinforced concrete at different humidity conditions, and frequencies with extended Debye's model. This analysis leads to the conclusion that SCMR can be used to efficiently power sensors in plain and reinforced concrete at different humidity levels and depth, also validated through electromagnetic simulations. The optimization of wireless power transmission via SMCR to Wearable and Implantable Medical Device (WIMD) are also explored. The optimum conditions from the analytics were used in the model for propagation of energy through different human tissues. This analysis shows that SCMR can be used to efficiently transfer power to sensors in human tissue without overheating through electromagnetic simulations, as excessive power might result in overheating of the tissue. Standard SCMR is sensitive to misalignment; both 2-loops and 3-loops SCMR with misalignment-insensitive performances are presented. The power transfer efficiencies above 50% was achieved over the complete misalignment range of 0°-90° and dramatically better than typical SCMR with efficiencies less than 10% in extreme misalignment topologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The research of power-line communications has been concentrated on home automation, broadband indoor communications and broadband data transfer in a low voltage distribution network between home andtransformer station. There has not been carried out much research work that is focused on the high frequency characteristics of industrial low voltage distribution networks. The industrial low voltage distribution network may be utilised as a communication channel to data transfer required by the on-line condition monitoring of electric motors. The advantage of using power-line data transfer is that it does not require the installing of new cables. In the first part of this work, the characteristics of industrial low voltage distribution network components and the pilot distribution network are measured and modelled with respect topower-line communications frequencies up to 30 MHz. The distributed inductances, capacitances and attenuation of MCMK type low voltage power cables are measured in the frequency band 100 kHz - 30 MHz and an attenuation formula for the cables is formed based on the measurements. The input impedances of electric motors (15-250 kW) are measured using several signal couplings and measurement based input impedance model for electric motor with a slotted stator is formed. The model is designed for the frequency band 10 kHz - 30 MHz. Next, the effect of DC (direct current) voltage link inverter on power line data transfer is briefly analysed. Finally, a pilot distribution network is formed and signal attenuation in communication channels in the pilot environment is measured. The results are compared with the simulations that are carried out utilising the developed models and measured parameters for cables and motors. In the second part of this work, a narrowband power-line data transfer system is developed for the data transfer ofon-line condition monitoring of electric motors. It is developed using standardintegrated circuits. The system is tested in the pilot environment and the applicability of the system for the data transfer required by the on-line condition monitoring of electric motors is analysed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Työn tavoitteena oli selvittää uudenlaisen WLAN-verkkoyhteyden tarjoajan liiketoiminnallisia mahdollisuuksia ja -edellytyksiä. Uudenlaisessa mallissa loppukäyttäjällä on langatonta lähiverkkoa käyttäessään mahdollisuus valita mieleisensä Internet-operaattori sekä käyttää paikallisia palveluja ilman Internet-yhteyttä, alueverkon kautta. Lisaksi tutkittiin langattoman tiedonsiirron markkinointia. Työn case-osuudessa tutkittiin Lappeen¬rannan teknillisen korkeakoulun WLAN-hanketta, ja siinä rakennettua access-verkkoa. Koko langattoman tiedonsiirron liiketoimintakenttä on vasta hakemassa lopullisia muotojaan. Nopeasta yleistymisestä huolimatta WLAN:in massamarkkinoille tuloa hidastavat tietyt ongelmat, mm. verkkovierailut (sekä WLAN-verkkojen että eri langattomien tiedonsiirtoteknologioiden välillä), epäselvät laskutusmallit sekä yhteensopivuusongelmat. Tietoturva on WLAN:in ongelmista kuuluisin, mutta ei suurin este todellisten massamarkkinoiden saavuttamisessa. Hyödyntämällä teknologian omaksujaryhmien erilaisia piirteitä saadaan etua tavoiteltaessa massamarkkinoita. Case-verkon liiketoimintasuunnitelmasta käy ilmi, että mikäli WLAN yleistyy, kuten on odotettu, esitetty uudenlainen alueellinen liiketoimintamalli voi olla taloudellisesti mahdollinen. Esitetyt riskit ja oletukset on huomioitava alan epävarman kehityksen takia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Data traffic caused by mobile advertising client software when it is communicating with the network server can be a pain point for many application developers who are considering advertising-funded application distribution, since the cost of the data transfer might scare their users away from using the applications. For the thesis project, a simulation environment was built to mimic the real client-server solution for measuring the data transfer over varying types of connections with different usage scenarios. For optimising data transfer, a few general-purpose compressors and XML-specific compressors were tried for compressing the XML data, and a few protocol optimisations were implemented. For optimising the cost, cache usage was improved and pre-loading was enhanced to use free connections to load the data. The data traffic structure and the various optimisations were analysed, and it was found that the cache usage and pre-loading should be enhanced and that the protocol should be changed, with report aggregation and compression using WBXML or gzip.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Physiological parameters measured by an embedded body sensor system were demonstrated to respond to changes of the air temperature in an office environment. The thermal parameters were monitored with the use of a wireless sensor system that made possible to turn any existing room into a field laboratory. Two human subjects were monitored over daily activities and at various steady-state thermal conditions when the air temperature of the room was altered from 22-23°C to 25-28°C. The subjects indicated their thermal feeling on questionnaires. The measured skin temperature was distributed close to the calculated mean skin temperature corresponding to the given activity level. The variation of Galvanic Skin Response (GSR) reflected the evaporative heat loss through the body surfaces and indicated whether sweating occurred on the subjects. Further investigations are needed to fully evaluate the influence of thermal and other factors on the output given by the investigated body sensor system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The efficiency of a Wireless Power Transfer (WPT) system is greatly dependent on both the geometry and operating frequency of the transmitting and receiving structures. By using Coupled Mode Theory (CMT), the figure of merit is calculated for resonantly-coupled loop and dipole systems. An in-depth analysis of the figure of merit is performed with respect to the key geometric parameters of the loops and dipoles, along with the resonant frequency, in order to identify the key relationships leading to high-efficiency WPT. For systems consisting of two identical single-turn loops, it is shown that the choice of both the loop radius and resonant frequency are essential in achieving high-efficiency WPT. For the dipole geometries studied, it is shown that the choice of length is largely irrelevant and that as a result of their capacitive nature, low-MHz frequency dipoles are able to produce significantly higher figures of merit than those of the loops considered. The results of the figure of merit analysis are used to propose and subsequently compare two mid-range loop and dipole WPT systems of equal size and operating frequency, where it is shown that the dipole system is able to achieve higher efficiencies than the loop system of the distance range examined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PhEDEx, the CMS transfer management system, during the first LHC Run has moved about 150 PB and currently it is moving about 2.5 PB of data per week over the Worldwide LHC Computing Grid (WLGC). It was designed to complete each transfer required by users at the expense of the waiting time necessary for its completion. For this reason, after several years of operations, data regarding transfer latencies has been collected and stored into log files containing useful analyzable informations. Then, starting from the analysis of several typical CMS transfer workflows, a categorization of such latencies has been made with a focus on the different factors that contribute to the transfer completion time. The analysis presented in this thesis will provide the necessary information for equipping PhEDEx in the future with a set of new tools in order to proactively identify and fix any latency issues. PhEDEx, il sistema di gestione dei trasferimenti di CMS, durante il primo Run di LHC ha trasferito all’incirca 150 PB ed attualmente trasferisce circa 2.5 PB di dati alla settimana attraverso la Worldwide LHC Computing Grid (WLCG). Questo sistema è stato progettato per completare ogni trasferimento richiesto dall’utente a spese del tempo necessario per il suo completamento. Dopo svariati anni di operazioni con tale strumento, sono stati raccolti dati relativi alle latenze di trasferimento ed immagazzinati in log files contenenti informazioni utili per l’analisi. A questo punto, partendo dall’analisi di una ampia mole di trasferimenti in CMS, è stata effettuata una suddivisione di queste latenze ponendo particolare attenzione nei confronti dei fattori che contribuiscono al tempo di completamento del trasferimento. L’analisi presentata in questa tesi permetterà di equipaggiare PhEDEx con un insieme di utili strumenti in modo tale da identificare proattivamente queste latenze e adottare le opportune tattiche per minimizzare l’impatto sugli utenti finali.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Java Enterprise Applications (JEAs) are complex software systems written using multiple technologies. Moreover they are usually distributed systems and use a database to deal with persistence. A particular problem that appears in the design of these systems is the lack of a rich business model. In this paper we propose a technique to support the recovery of such rich business objects starting from anemic Data Transfer Objects (DTOs). Exposing the code duplications in the application's elements using the DTOs we suggest which business logic can be moved into the DTOs from the other classes.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabajo forma parte del proyecto “Health aware enhanced range wireless power transfer systems”, conocido por el acrónimo de ETHER. Los grupos investigadores que forman parte de ETHER involucran a dos instituciones, Universidad Politécnica de Cataluña (UPC) y Universidad Politécnica de Madrid (UPM). En este caso, el trabajo ha sido llevado a cabo en el marco del Centro de Electrónica Industrial(CEI) de la UPM. Además, este trabajo es el tercero en una sucesión de estudios realizados por el CEI con el objetivo de lograr implementar un sistema de carga inalámbrica en un marcapasos. Los trabajos previos al desarrollado son los realizados por Miguel Gifford y María Gonzalez. Otros trabajos del CEI han servido de guía. El principal objetivo de la aplicación, es evitar las operaciones que se llevan a cabo actualmente para la sustitución de la batería de los marcapasos implantados en pacientes. Este periodo de sustitución es del orden de cuatro años, lo que depende del tipo de marcapasos y las circunstancias en las que se vea envuelto el paciente. Se pretende lograr la carga del dispositivo causando la menor molestia posible al paciente sin afectar a su salud. El sistema de carga inalámrica o WPT1, está basado en inducción magnética resonante, conocida como RIC2. Esta tecnología se fundamenta en el uso de bobinas acopladas como elemento transmisor de energía. A su vez, la impedancia de estas bobinas, es compensada mediante el uso de condensadores, obteniendo circuitos resonantes. Mediante el uso de RIC se logran mejores características técnicas para la transmisión de energía en el rango medio. Esto permite salvar la distancia entre el elemento generador y la batería del marcapasos, incluso ante la existencia de tejido orgánico entre las dos bobinas. Se han considerado dos posibilidades de configuraci´on del sistema. Dos etapas: se dispone de dos bobinas, emisora y receptora. Esta configuración supone trabajar a altas frecuencias para conseguir transferencia de energías efectivas teniendo en cuenta las especificaciones del marcapasos. Tres etapas: se dispone de tres bobinas, emisora, intermedia y receptora. Se mejora el alcance, permitiendo trabajar a menores frecuencias, pero complicando el control y la implementación del sistema. Sin embargo, el foco de los esfuerzos invertidos en este trabajo, es el estudio del sistema de optimización que se introduce en las configuraciones anteriormente descritas. La optimización se centra en conseguir máxima transferencia de potencia, quedando relegado a un segundo plano el rendimiento. Esto se justifica por las características de la aplicación donde la principal limitación es la viabilidad del sistema. Asímismo, la viabilidad viene impuesta por la potencia que consume el marcapasos y la que es capaz de suministrar el sistema. Este sistema de optimización se basa en la regulación en frecuencia y en la adaptación de la impedancia de carga. Este último método es estudiado, y se basa en lograr una impedancia de carga igual al complejo conjugado de la impedancia de salida, logrando máxima transferencia de potencia. El sistema de optimización hace uso de varias estructuras de control de electrónica de potencia. Inversor: Se sitúa en la etapa emisora y permite controlar la frecuencia de trabajo del sistema. Rectificador activo: Se sitúa en la etapa receptora y controla el desfase entre intensidad y tensión. Convertidor CC-CC: Se sitúa en la etapa receptora, tras el rectificador. Controla la amplitud de la tensión.Mediante el uso conjunto del rectificador y el convertidor es posible controlar la impedancia de la carga. Se ha realizado un análisis teórico para determinar el punto de funcionamiento óptimo del sistema, y posteriormente, se han validado estos resultados mediante simulaciones. Se demuestra que la potencia transferida por el sistema WTP se multiplica por cinco respecto de la solución original, es decir, en ausencia del sistema de optimización. Además se logra mayor robustez, ya que el control activo del sistema proporciona mayor adaptabilidad ante condiciones alejadas de las de diseño. El trabajo realizado se ha prolongado durante un periodo de doscientos días efectivos con una dedicación de 360 horas de trabajo. El coste total asignado al desempeño del trabajo es de 16.678,94 euros.