855 resultados para Well-established techniques
Resumo:
Antibodies to citrullinated peptides are highly specific for rheumatoid arthritis (RA) and represent a significant risk factor for undifferentiated polyarthritis. This prognostic ability may be related to the very diagnostic performance of these autoantibodies, since RA is a more erosive disease than other forms of arthritis. The present study evaluated an association of antibodies to citrullinated peptides and the rate of joint destruction in patients with a well-established diagnosis of RA. Seventy-one patients with RA were evaluated in 1994 and again in 2002 (functional class, joint count, Health Assessment Questionnaire score, hands X-ray). Autoantibodies (rheumatoid factor (RF), anti-perinuclear factor, anti-cyclic citrullinated peptide (CCP) antibodies) and Sharp's index were analyzed blindly. Delta Sharp was calculated as the difference in Sharp's index obtained in 1994 and 2002. During the follow-up the Health Assessment Questionnaire score increased from 0.91 ± 0.74 to 1.39 ± 0.72 (P < 0.001). Similarly, the number of swollen joints increased from 4.6 ± 5.71 to 6.4 ± 4.1 (P = 0.002). The frequency of autoantibodies and anti-CCP titer remained stable; however, serum RF concentration increased from 202.8 ± 357.6 to 416.6 ± 636.5 IU/mL (P = 0.003). Sharp's index increased from 56.7 ± 62.1 to 92.4 ± 80.9 (P < 0.001). No correlation was observed between Delta Sharp and the presence of RF, anti-perinuclear factor, and anti-CCP antibodies at baseline. Antibodies to citrullinated epitopes are specific and early markers for the diagnosis of RA but do not seem to be associated with the rate of joint destruction in patients with a well-established diagnosis of RA.
Resumo:
Previous analyses of mitochondrial (mt)DNA and allozymes covering the range of the Iberian endemic golden-striped salamander, Chioglossa lusitanica, suggested a Pleistocene split of the historical species distribution into two population units (north and south of the Mondego river), postglacial expansion into the northernmost extant range, and secondary contact with neutral diffusion of genes close to the Mondego river. We extended analysis of molecular variation over the species range using seven microsatellite loci and the nuclear P-fibrinogen intron 7 (beta-fibint7). Both microsatellites and beta-fibint7 showed moderate to high levels of population structure, concordant with patterns detected with mtDNA and allozymes; and a general pattern of isolation-by-distance, contrasting the marked differentiation of two population groups suggested by mtDNA and allozymes. Bayesian multilocus analyses showed contrasting results as populations north and south of the Douro river were clearly differentiated based on microsatellites, whereas allozymes revealed differentiation north and south of the Mondego river. Additionally, decreased microsatellite variability in the north supported the hypothesis of postglacial colonization of this region. The well-documented evolutionary history of C. lusitanica, provides an excellent framework within which the advantages and limitations of different classes of markers can be evaluated in defining patterns of population substructure and inferring evolutionary processes across distinct spatio-temporal scales. The present study serves as a cautionary note for investigations that rely on a single type of molecular marker, especially when the organism under study exhibits a widespread distribution and complex natural history. (C) 2008 The Linnean Society of London, Biological Journal of the Linnean Society, 2008, 95, 371-387.
Resumo:
Delayed feedback (DF) control is a well-established technique to suppress single frequency vibration of a non-minimum phase system. Modal control is also a well-established technique to control multiple vibration modes of a minimum phase system. In this paper these techniques are combined to simultaneously suppress multiple vibration modes of a non-minimum phase system involving a small time delay. The control approach is called delayed resonant feedback (DRF) where each modal controller consists of a modal filter to extract the target mode signal from the vibration response, and a phase compensator to account for the phase delay of the mode. The methodology is first discussed using a single mode system. A multi-mode system is then studied and experimental results are presented to demonstrate the efficacy of the control approach for two modes of a beam. It is shown that the system behaves as if each mode under control has a dynamic vibration absorber attached to it, even though the actuator and the sensor are not collocated and there is a time delay in the control system. © 2013 IOP Publishing Ltd.
Resumo:
A very recent and exciting new area of research is the application of Concurrency Theory tools to formalize and analyze biological systems and one of the most promising approach comes from the process algebras (process calculi). A process calculus is a formal language that allows to describe concurrent systems and comes with well-established techniques for quantitative and qualitative analysis. Biological systems can be regarded as concurrent systems and therefore modeled by means of process calculi. In this thesis we focus on the process calculi approach to the modeling of biological systems and investigate, mostly from a theoretical point of view, several promising bio-inspired formalisms: Brane Calculi and k-calculus family. We provide several expressiveness results mostly by means of comparisons between calculi. We provide a lower bound to the computational power of the non Turing complete MDB Brane Calculi by showing an encoding of a simple P-System into MDB. We address the issue of local implementation within the k-calculus family: whether n-way rewrites can be simulated by binary interactions only. A solution introducing divergence is provided and we prove a deterministic solution preserving the termination property is not possible. We use the symmetric leader election problem to test synchronization capabilities within the k-calculus family. Several fragments of the original k-calculus are considered and we prove an impossibility result about encoding n-way synchronization into (n-1)-way synchronization. A similar impossibility result is obtained in a pure computer science context. We introduce CCSn, an extension of CCS with multiple input prefixes and show, using the dining philosophers problem, that there is no reasonable encoding of CCS(n+1) into CCSn.
Resumo:
Feste Lösungen homogen dispergierter Wirkstoffmoleküle in amorphen Polymermatrizen sind wichtige Materialien in vielen pharmazeutischen Anwendungen, bei denen eine kontrollierte Abgabe wasserunlöslicher Wirkstoffe in wässrige Systeme eine Rolle spielt. Die intermolekulare Bindungs-stärke zwischen Polymer- und Wirkstoffmolekülgruppen bestimmt die Stabilität der festen Lösung und steuert somit die biologische Aktivität der Wirkstoffmoleküle. In festen Lösungen, die aus acryl-säurehaltigen Copolymeren (Protonendonoren) und basischen Wirkstoffmolekülen (Protonenakzepto-ren) hergestellt werden, sind intermolekulare Wasserstoffbrücken zwischen den Systemkomponenten Triebkraft für die Bildung einer stabilen homogenen Dispersion und für die Entstehung struktureller Merkmale zwischen den Molekülgruppen der Systemkomponenten. Zudem ist die Bindungsstärke der Wasserstoffbrücken im Hinblick auf die kontrollierte Abgabe der Wirkstoffe von Bedeutung. Da dynamische chemische Gleichgewichte bei der Bildung der Wasserstoffbrücken eine wichtige Rolle spielen müssen neben strukturellen Parametern auch dynamische Faktoren beleuchtet werden. Ziel dieser Arbeit ist neben der Ermittlung von intermolekularen Bindungsstärken vor allem die Identifika-tion struktureller Verhältnisse zwischen den Systemkomponenten auf molekularer Ebene. Die Be-stimmung der Abhängigkeit dieser Parameter von der Struktur der verwendeten Polymere und einer Vielzahl weiterer Einflüsse wie z.B. Feuchtigkeit, Lagerdauer oder Wirkstoffkonzentration soll ein kontrolliertes Design fester Lösungen mit definierten anwendungsspezifischen Eigenschaften ermögli-chen. Temperaturabhängige 1H-Festkörper-MAS-NMR (Magic Angle Spinning Nuclear Magnetic Resonance) Experimente an festen Lösungen mit unterschiedlichen Copolymer-Zusammensetzungen weisen die Existenz dynamischer chemischer Gleichgewichte in den komplexen Wasserstoffbrücken-netzwerken nach. Veränderungen in der chemischen Verschiebung und in der Linienform der Reso-nanzlinien acider Protonen erlauben einen tiefen Einblick in die Architektur dieser Netzwerke und legen die Bindungsverhältnisse unter Berücksichtigung der Polymerchemie und der Mobilität der Systemkomponenten dar, wobei die Befunde mithilfe quantenchemischer Rechnungen untermauert werden können. Die Gegenwart acider Protonen ermöglicht einen einfachen 1H-2H-Austausch, wor-aufhin mithilfe rotorsynchronisierter temperaturabhängiger 2H-MAS-NMR Experimente die Wasser-stoffbrückenbindungsstärke bestimmt werden kann. Mit 1H-1H-Korrelationsexperimenten (Doppelquantenspektroskopie) stehen Methoden für die Bestimmung homonuklearer dipolarer 1H-1H-Kopplungen zur Verfügung, die strukturelle Aussagen aufgrund von bevorzugten räumlichen Kontak-ten bestimmter Molekülgruppen ermöglichen. Weiterhin können diese Experimente verwendet werden, um Wasserstoffbrücken zwischen Polymergruppen von Polymer-Wirkstoff-Wasserstoffbrücken zu unterscheiden, wodurch eine quantitative Beschreibung des Bindungsnetzwerks und der Konkurrenz-prozesse zwischen den einzelnen wasserstoffverbrückten Spezies ermöglicht wird. Eine Kristallisation der Wirkstoffmoleküle ist in vielen Anwendungen unerwünscht, da sie die biologische Verfügbarkeit des Wirkstoffs reduzieren. Mit 1H-Festkörper-MAS-NMR Experimenten können kristalline von amorph dispergierten Wirkstoffmolekülen unterschieden werden, wodurch eine Quantifizierung der Destabilisierungsprozesse ermöglicht wird, die durch Exposition der festen Lösungen mit Wasserdampf ausgelöst werden können. Die Zeit- und Konzentrationsabhängigkeit der Wasseraufnahme kann mit NMR-Experimenten verfolgt werden, wobei unterschiedlich mobile Was-serspezies an unterschiedlichen Bindungsorten identifiziert werden können, was zum molekularen Verständnis der Destabilisierungsprozesse beiträgt. Zusätzlich wird die Mobilität der Wirkstoffmole-küle bestimmt, die sich – wie auch die Wirkstoffkonzentration - als wichtige Größe in der Beschrei-bung der Destabilisierung erweist. Aufbauend auf den Beobachtungen wird ein Zusammenhang zwischen der Copolymerzusammensetzung und einer kritischen Wirkstoffkonzentration hergestellt, der für die Anwendungen amorpher fester Lösungen in biologischen Systemen von großer Bedeutung ist.
Resumo:
Summary form only given. Broadly tunable compact visible laser sources in the spectral region of 500-650 nm are valuable in biophotonics, photomedicine and for many applications including spectroscopy, laser projection and confocal microscopy. Unfortunately, commercially available lasers of this spectral range are in practice bulky and inconvenient in use. An attractive method for the realization of portable visible laser sources is the frequency-doubling of the infrared laser diodes in a nonlinear crystal containing a waveguide [1]. Nonlinear crystal waveguides that offer an order-of-magnitude increase in the IR-to-visible conversion efficiency also enable a very different approach to second-harmonic generation (SHG) tunability in periodically-poled crystals, promising order-of-magnitude increase of wavelength range for SHG conversion. This is possible by utilization of a significant difference in the effective refractive indices of the high-order and low-order modes in multimode waveguides [2]. The recent availability of low-cost, good quality semiconductor diode lasers, offering the coverage of a broad spectral range between 1 µ?? and 1.3 µp? [3,4], in combination with well-established techniques to fabricate good quality waveguides in nonlinear crystals, allows compact tunable CW laser sources in the visible spectral region to be realized [2].
Resumo:
Compact and tunable semiconductor terahertz sources providing direct electrical control, efficient operation at room temperatures and device integration opportunities are of great interest at the present time. One of the most well-established techniques for terahertz generation utilises photoconductive antennas driven by ultrafast pulsed or dual wavelength continuous wave laser systems, though some limitations, such as confined optical wavelength pumping range and thermal breakdown, still exist. The use of quantum dot-based semiconductor materials, having unique carrier dynamics and material properties, can help to overcome limitations and enable efficient optical-to-terahertz signal conversion at room temperatures. Here we discuss the construction of novel and versatile terahertz transceiver systems based on quantum dot semiconductor devices. Configurable, energy-dependent optical and electronic characteristics of quantum-dot-based semiconductors are described, and the resonant response to optical pump wavelength is revealed. Terahertz signal generation and detection at energies that resonantly excite only the implanted quantum dots opens the potential for using compact quantum dot-based semiconductor lasers as pump sources. Proof-of-concept experiments are demonstrated here that show quantum dot-based samples to have higher optical pump damage thresholds and reduced carrier lifetime with increasing pump power.
Resumo:
This thesis develops and validates the framework of a specialized maintenance decision support system for a discrete part manufacturing facility. Its construction utilizes a modular approach based on the fundamental philosophy of Reliability Centered Maintenance (RCM). The proposed architecture uniquely integrates System Decomposition, System Evaluation, Failure Analysis, Logic Tree Analysis, and Maintenance Planning modules. It presents an ideal solution to the unique maintenance inadequacies of modern discrete part manufacturing systems. Well established techniques are incorporated as building blocks of the system's modules. These include Failure Mode Effect and Criticality Analysis (FMECA), Logic Tree Analysis (LTA), Theory of Constraints (TOC), and an Expert System (ES). A Maintenance Information System (MIS) performs the system's support functions. Validation was performed by field testing of the system at a Miami based manufacturing facility. Such a maintenance support system potentially reduces downtime losses and contributes to higher product quality output. Ultimately improved profitability is the final outcome. ^
Resumo:
The growing need for fast sampling of explosives in high throughput areas has increased the demand for improved technology for the trace detection of illicit compounds. Detection of the volatiles associated with the presence of the illicit compounds offer a different approach for sensitive trace detection of these compounds without increasing the false positive alarm rate. This study evaluated the performance of non-contact sampling and detection systems using statistical analysis through the construction of Receiver Operating Characteristic (ROC) curves in real-world scenarios for the detection of volatiles in the headspace of smokeless powder, used as the model system for generalizing explosives detection. A novel sorbent coated disk coined planar solid phase microextraction (PSPME) was previously used for rapid, non-contact sampling of the headspace containers. The limits of detection for the PSPME coupled to IMS detection was determined to be 0.5-24 ng for vapor sampling of volatile chemical compounds associated with illicit compounds and demonstrated an extraction efficiency of three times greater than other commercially available substrates, retaining >50% of the analyte after 30 minutes sampling of an analyte spike in comparison to a non-detect for the unmodified filters. Both static and dynamic PSPME sampling was used coupled with two ion mobility spectrometer (IMS) detection systems in which 10-500 mg quantities of smokeless powders were detected within 5-10 minutes of static sampling and 1 minute of dynamic sampling time in 1-45 L closed systems, resulting in faster sampling and analysis times in comparison to conventional solid phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) analysis. Similar real-world scenarios were sampled in low and high clutter environments with zero false positive rates. Excellent PSPME-IMS detection of the volatile analytes were visualized from the ROC curves, resulting with areas under the curves (AUC) of 0.85-1.0 and 0.81-1.0 for portable and bench-top IMS systems, respectively. Construction of ROC curves were also developed for SPME-GC-MS resulting with AUC of 0.95-1.0, comparable with PSPME-IMS detection. The PSPME-IMS technique provides less false positive results for non-contact vapor sampling, cutting the cost and providing an effective sampling and detection needed in high-throughput scenarios, resulting in similar performance in comparison to well-established techniques with the added advantage of fast detection in the field.
Resumo:
Capillary C4d deposition has been recognized as a marker of antibody-mediated rejection (AMR). Although the detection of capillary C4d by means of immunofluorescence (IF) in cryostat sections is well established, frozen tissue is not always available, thus limiting the diagnosis of AMR. The aim of the present study was to analyze different techniques for C4d staining and the prevalence of C4d in renal allograft biopsies. Detection of C4d was carried out using IF or immunohistochemistry (IHC) on frozen and paraffin sections of renal allograft biopsies available from the same patients. Biopsies obtained from 20 patients were classified into 3 groups: no rejection, acute rejection, and chronic allograft nephropathy (CAN). The capillary C4d deposition prevalence in frozen-IF, considered the gold standard technique for C4d detection, was 45% (9/20 cases). Compared with frozen-IF, the frozen-IHC technique presented an 85% concordance rate (17/20 cases; r =.70; P <.001; sensitivity = 77.8%; specificity = 90.9%). The paraffin-IF technique showed similar results, with an 80% concordance rate (16/20 cases; r =.64; P <.005; sensitivity = 55.6%; specificity = 100%), whereas C4d detection occurred in only 65% of paraffin-IHC cases (13/20; r =.30; not significant; sensitivity = 66.7%; specificity = 63.6%). No capillary C4d deposition was detected in cases without evidence of rejection. However, 4/7 cases (57%) of acute rejection were C4d positive. In the CAN group, 5111 cases (45%) were C4d positive. In conclusion, these results demonstrated that frozen-IHC and paraffin-IF can be considered alternative techniques to frozen-IF for C4d detection. The paraffin-IHC technique displayed the lowest concordance rate for C4d detection.
Resumo:
Malposition of the acetabular component during hip arthroplasty increases the occurrence of impingement, reduces range of motion, and increases the risk of dislocation and long-term wear. To prevent malpositioned hip implants, an increasing number of computer-assisted orthopaedic systems have been described, but their accuracy is not well established. The purpose of this study was to determine the reproducibility and accuracy of conventional versus computer-assisted techniques for positioning the acetabular component in total hip arthroplasty. Using a lateral approach, 150 cups were placed by 10 surgeons in 10 identical plastic pelvis models (freehand, with a mechanical guide, using computer assistance). Conditions for cup implantations were made to mimic the operating room situation. Preoperative planning was done from a computed tomography scan. The accuracy of cup abduction and anteversion was assessed with an electromagnetic system. Freehand placement revealed a mean accuracy of cup anteversion and abduction of 10 degrees and 3.5 degrees, respectively (maximum error, 35 degrees). With the cup positioner, these angles measured 8 degrees and 4 degrees (maximum error, 29.8 degrees), respectively, and using computer assistance, 1.5 degrees and 2.5 degrees degrees (maximum error, 8 degrees), respectively. Computer-assisted cup placement was an accurate and reproducible technique for total hip arthroplasty. It was more accurate than traditional methods of cup positioning.
Resumo:
The laparoscopic approach has emerged as a valid option for surgical management of kidney cancer, as well as a few benign pathologies. The immediate benefits of laparoscopy are well established and include less estimated blood loss, decreased pain, shorter perioperative convalescence, and improved cosmesis. Long-term oncologic outcomes of patients treated laparoscopically for kidney tumors are similar to those of open surgery.
Resumo:
Chemical analysis is a well-established procedure for the provenancing of archaeological ceramics. Various analytical techniques are routinely used and large amounts of data have been accumulated so far in data banks. However, in order to exchange results obtained by different laboratories, the respective analytical procedures need to be tested in terms of their inter-comparability. In this study, the schemes of analysis used in four laboratories that are involved in archaeological pottery studies on a routine basis were compared. The techniques investigated were neutron activation analysis (NAA), X-ray fluorescence analysis (XRF), inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS). For this comparison series of measurements on different geological standard reference materials (SRM) were carried out and the results were statistically evaluated. An attempt was also made towards the establishment of calibration factors between pairs of analytical setups in order to smooth the systematic differences among the results.