892 resultados para Wave forms


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To evaluate the relationship between ductus venosus Doppler findings on the day of delivery and postnatal outcomes in pregnancies with absent or reversed end-diastolic (ARED) flow in the umbilical arteries. Study design: Postnatal outcomes of 103 newborns of pregnancies with a diagnosis of ARED flow on Doppler velocimetry of the umbilical arteries were analyzed retrospectively between January 1997 and December 2004. Single pregnancies and fetuses without malformations were included. The cases were divided into two groups according to the flow during atrial contraction (a-wave) in the ductus venosus on the day of delivery: group A, 20 cases with absent or reversed flow in the ductus venosus and group B, 83 cases with positive flow. The results were analyzed statistically using the chi-square test, Fisher`s exact test and the Mann-Whitney U test with the level of significance set at 5%. Results: All newborns were delivered by cesarean section. Gestational age was similar in the two groups (group A: 30 weeks and group B: 30.9 weeks, P = 0.23). Absent or reversed ductus venosus flow was associated with the following adverse postnatal outcomes: lower birthweight (P < 0.001), lower Apgar scores in the first (P = 0.001) and fifth minute (P = 0.001), a higher frequency of orotracheal intubation (P = 0.001) and pH at birth less than 7.20 (P < 0.001), pulmonary hemorrhage (P = 0.03), thrombocytopenia (P = 0.02), hypoglycemia (P = 0.01), intracranial hemorrhage (P = 0.02), and postnatal death (P = 0.007). Conclusion: The study of ductus venosus flow may provide additional information regarding the best time for interruption of pregnancies with ARED flow in the umbilical arteries characterized by extreme prematurity. (C) 2008 Elsevier Ireland Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective To determine normal blood flow velocities across the fetal tricuspid valve (TV) at 11-13 weeks and 6 days of gestation and to examine the reproducibility of these measurements. Methods A prospective study involving 166 normal singleton pregnancies examined at 11-13 weeks and 6 days was carried out. Descriptive analysis of E- and A-waves` maximum velocities, E/A ratio, duration of the cardiac cycle (C) and diastole (D) and D/C ratio were calculated. Intraobserver and interobserver agreement analysis was performed in a subgroup of 12 cases. Results Average (+/- SD) flow velocities were: E-wave, 25.0 (+/- 4.6) cm/s; A-wave. 42.9 (+/- 5.9) cm/s; E/A, 0.58 (+/- 0.07); cardiac cycle, 390 (+/- 21.1) ms; diastole, 147 (+/- 18) ms and D/C, 0.38 (+/- 0.04). Significant correlation was observed between all parameters (except A-wave) and gestational age but not with nuchal translucency (NT). Intraclass correlation coefficients (interobserver, intraobsever examiner I and intraobserver examiner 2) were: E-wave, 0.53, 0.53 and 0.64; A-wave, 0.45, 0.46 and 0.49; cardiac cycle, 0.70, 0.79 and 0.84 and diastole, 0.63, 0.85 and 0.82, respectively. Conclusions The present study establishes normal Doppler parameters for blood flow across the TV at 11 - 13 weeks and 6 days and demonstrates that these parameters do not correlate with NT measurement and have good/moderate reproducibility. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of the present study was to evaluate fetal biometry, Doppler values, and perinatal outcomes in pregnant women with antiphospholipid syndrome treated with acetylsalicylic acid and heparin. Twenty-five pregnant women with antiphospholipid syndrome using 100 mg/day acetylsalicylic acid and 5,000 IU heparin every 12 h were evaluated in this prospective observational study. Ultrasonography was performed between 24 and 38 weeks of gestational age to assess estimated fetal weight, placental thickness, amniotic fluid index, fetal biophysical profile and Doppler evaluation of maternal uterine arteries, and fetal middle cerebral and umbilical arteries. Data regarding Apgar score, gender, delivery mode, and birth weight and length were recorded after birth. The observed values for ultrasonographic assessment and perinatal outcomes were not very different from the expected values for normal pregnancies. The birth weight was 2863.3 +/- A 737.7 g (mean +/- A SD) and length was 46.8 +/- A 4.2 cm. Only one newborn (4%) had the 1-min Apgar score < 7 and all had the 5-min Apgar score > 7. Gestational and perinatal evaluation of pregnant women with antiphospholipid syndrome using both acetylsalicylic acid and heparin was reassuring.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this study was to describe multiple Doppler ultrasound parameters of ductus venosus and inferior vena cava in fetuses at gestational ages ranging from 22 to 38 weeks. In this prospective observational study, Doppler ultrasound exams were performed in 45 healthy fetuses at 22, 26, 34, and 38 weeks. Maximum venous velocity, minimum venous velocity, venous pulsatility index, and venous acceleration time (VAT) (defined as the time between minimum and maximum venous velocity) were evaluated at those gestational periods. Increase in the velocities and decrease in the pulsatility index were observed in these vessels throughout gestational age. The VAT increased with gestational age. The VAT, a Doppler parameter still not described elsewhere, increased during pregnancy could be related to a longer period of time needed to fill the atrium in bigger hearts. In this study, we provide reference values for VAT in healthy fetuses.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O diagnóstico de máquinas elétricas pela análise de vibração é utilizado num plano de manutenção, onde é dado a conhecer a “real condição do equipamento”, e surgiu da necessidade de detetar vibrações indesejáveis nas máquinas elétricas, de uma forma simples e com custos acessíveis. Numa fase inicial é obtido um sinal correspondente á vibração da máquina, recorrendo a um acelerômetro, que dependendo da aceleração da máquina, constrói uma forma de onda correspondente. A forma de onda fica guardada em formato de áudio *.wav. Posteriormente, em software Matlab o ficheiro *.wav irá ser carregado, e comparado com o ficheiro *.wav original da máquina. Ao comparar os ficheiros o software analisa o espectro original da máquina através da transformada de Fourier, com o espectro atual. Se este espectro sair do intervalo de segurança, o software deteta nesse espectro a origem da vibração, pois cada vibração tem uma frequência associada. Percorridos os passos descritos, o software disponibiliza ao utilizador as respetivas formas de onda e todo o restante diagnóstico de forma a uma possível intervenção antecipada da avaria.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes a novel approach for mapping lightning models using artificial neural networks. The networks acts as identifier of structural features of the lightning models so that output parameters can be estimated and generalized from an input parameter set. Simulation examples are presented to validate the proposed approach. More specifically, the neural networks are used to compute electrical field intensity and critical disruptive voltage taking into account several atmospheric and structural factors, such as pressure, temperature, humidity, distance between phases, height of bus bars, and wave forms. A comparative analysis with other approaches is also provided to illustrate this new methodology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a general modeling approach to investigate and to predict measurement errors in active energy meters both induction and electronic types. The measurement error modeling is based on Generalized Additive Model (GAM), Ridge Regression method and experimental results of meter provided by a measurement system. The measurement system provides a database of 26 pairs of test waveforms captured in a real electrical distribution system, with different load characteristics (industrial, commercial, agricultural, and residential), covering different harmonic distortions, and balanced and unbalanced voltage conditions. In order to illustrate the proposed approach, the measurement error models are discussed and several results, which are derived from experimental tests, are presented in the form of three-dimensional graphs, and generalized as error equations. © 2009 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper investigates the major similarities and discrepancies among three important current decompositions proposed for the interpretation of unbalanced and/or non linear three-phase four-wire power circuits. The considered approaches were the so-called FBD Theory, the pq-Theory and the CPT. Although the methods are based on different concepts, the results obtained under ideal conditions (sinusoidal and balanced signals) are very similar. The main differences appear in the presence of unbalanced and non linear load conditions. It will be demonstrated and discussed how the choice of the voltage referential and the return conductor impedance can influence in the resulting current components, as well as, the way of interpreting a power circuit with return conductor. Under linear unbalanced conditions, both FBD and pq-Theory suggest that the some current components contain a third-order harmonic. Besides, neither pq-Theory nor FBD method are able to provide accurate information for reactive current under unbalanced and distorted conditions, what can be done by means of the CPT. © 2009 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a practical experimentation for comparing reactive/non-active energy measures, considering three-phase four-wire non-sinusoidal and unbalanced circuits, involving five different commercial electronic meters. The experimentation set provides separately voltage and current generation, each one with any waveform involving up to fifty-first harmonic components, identically compared with acquisitions obtained from utility. The experimental accuracy is guaranteed by a class A power analyzer, according to IEC61000-4-30 standard. Some current and voltage combination profiles are presented and confronted with two different references of reactive/non-active calculation methodologies; instantaneous power theory and IEEE 1459-2010. The first methodology considers the instantaneous power theory, present into the advanced mathematical internal algorithm from WT3000 power analyzer, and the second methodology, accomplish with IEEE 1459-2010 standard, uses waveform voltage and current acquisition from WT3000 as input data for a virtual meter developed on Mathlab/Simulink software. © 2012 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: To identify potential associations between fetal surveillance tests and acidosis at birth in pregnancies with abnormal but positive end-diastolic velocity in the umbilical artery. Methods: A prospective case-control study [group 1: pH < 7.2; group 2: pH >= 7.2] including 46 fetuses with abnormal but positive end-diastolic velocity in the umbilical artery was conducted between February 2007 and March 2009. Outcome variables were evaluated by univariate analysis and compared between the two groups. Clinically relevant and statistically significant variables were analyzed by logistic regression. Results: Abnormal nonstress test, presence of deceleration, and absent fetal breathing movements were statistically significant. Logistic regression analysis revealed that fetal heart rate (FHR) deceleration in the nonstress test is the only predictor of fetal acidosis at birth (p = 0.024; OR = 8.2; 95% CI: 1.2-52). Conclusions: In fetuses with positive end-diastolic flow velocity, acute variables of the antenatal surveillance tests are correlated with acidosis at birth and FHR deceleration in the nonstress test is the only predictor of fetal acidosis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We propose a scheme for coupling laser light into graphene plasmons with the help of electrically generated surface acoustic waves. The surface acoustic wave forms a diffraction grating which allows us to excite the long lived phononlike branch of the hybridized graphene plasmon-phonon dispersion with infrared laser light. Our approach avoids patterning the graphene sheet, does not rely on complicated optical near-field techniques, and allows us to electrically switch the coupling between far-field radiation and propagating graphene plasmons.