995 resultados para Water line
Resumo:
Water from dental equipment presents risks for surgeon-dentists as well as for patients because it might work as a means of dissemination/ transmission of microoganisms. The objective of this study was to verify the quality of the water used in dental equipment by means of microbiological analysis, accomplishing the count of Staphylococcus spp.There have been collected, 160 samples of water from reserviors, taps used for hand washing, air-water syringes, and high-speed handpieces, in 40 dental offices in the city of Barretos, São Paulo. The rules concerning bacteriotogicaI analysis in cfu/mL from Standard Methods for the Examination of Water and Wastewater have been followed. The analysis of the results has made it possible to verify that out of the total of samples, 28% did not meet the standards of potability established by the American Dental Association: Regarding the origin of analyzed S. aureus., the most contaminated sites were high-speed handpicces in private offices (761%) and in, ental care plan offices (71%), followed by air-water syringe in dental care plan offices (64%). For S. epidermitis samples, the most contaminated sites were high-speed handpieces in SUS (Brazilian Government Health System) dental offices (22%) and in dental care plan offices (14%) The most contaminated sites were dental offices that saw Patients under dental care plans, Concerning tested antibiotics, the ones that presented better results as to sensibility to strain S. epidermidis were vancomycin and ciprofloxacin (100%) and, as to sensibility to strain S. aureus, it was ciprofloxacin (97%).
Resumo:
Cloud samples for the isotopic analysis were collected in the framework of the Hill Cap Cloud Thuringia 2010 (HCCT-2010) campaign on Schmücke (50° 39'N/ 10° 46'E, 937 m a.s.l.; Germany) in September and October 2010 with a three-stage Caltech Active Strand Cloudwater Collector (CASCC) during 13 different cloud events with a temporal resolution of 1 to 3 hours. In a first step, we ensured that no additional fractionation occurred during sampling with the CASCC. The d values of the three sizes classes of the CASCC (4 µm to 16 µm, 16 µm to 22 µm and >22 µm) did not differ significantly, revealing that the cloud droplets of different sizes quickly equilibrate their delta value with the one of the surrounding vapor. delta values in the cloud droplets varied from -77 per mil to -15 per mil in d2H and from -12.1 per mil to -3.9 per mil in d18O and were fitted by d2H =7.8*d18O +13*10**-3. delta values decreased with temperature as well as towards the end of the campaign, representing a seasonal trend which is known from d values in precipitation. The deuterium excess of the cloud samples was generally higher than the Local Meteoric Water Line of the closest GNIP (Global Network of Isotopes in Precipitation) station. Rain decreases its deuterium excess during falling through an unsaturated air column, while the cloud droplets conserve the deuterium excess of the initial evaporation and thus have been found to be a good indicator for the airmass source region: higher deuterium excess was measured for polar air masses and lower deuterium excess for Mediterranean air masses. Changes in d values during one cloud event were up to 3.6 per mil (d2H) and 0.23 per mil (d18O), except for frontal passages, which were associated with increases of ~6 per mil per hour (d2H) and ~0.6 per mil per hour (d18O). Using a box model, we showed that the influence of condensation only was able to explain the variation in the isotope signal of two cloud passages. Consequently, we deduced that the water vapor "feeding" the cloud advected the measured changes. A trajectory analysis and moisture source diagnostic revealed that it is very likely that the variations were either related to rain out along the trajectories or to meteorological changes in the moisture source region. This was the first study using stable water isotopologues in cloud water manifesting their potential in the context of atmospheric water vapor circulation.
Resumo:
A novel shear plate was used to make direct bed shear stress measurements in laboratory dam break and swash flows on smooth, fixed, impermeable beds. The pressure gradient due to the slope of the fluid free-surface across the plate was measured using pressure transducers. Surface elevation was measured at five locations using acoustic displacement sensors. Flow velocity was measured using an Acoustic-Doppler Velocimeter and calculated using the ANUGA inundation model. The measured bed shear stress at the dam break fluid tip for an initially dry, horizontal bed was close to twice that estimated using steady flow theory. The temporal variation of swash bed shear stress showed a large peak in landward directed stress at the uprush tip, followed by a rapid decay throughout the uprush flow interior. The peak seaward directed stress during the backwash phase was less than half that measured in the uprush. Close to the still water line, in the region of bore collapse and at the time of initial uprush, favourable pressure gradients were measured. In the lower swash region predominately weak adverse pressure gradients were measured.
Resumo:
The stable isotope composition of waters (delta H-2, delta O-18) can be used as a natural tracer of hydrologic processes in systems affected by acid mine drainage. We investigated the delta H-2 and delta O-18 values of pore waters from four oxidizing sulfidic mine tailings impoundments in different climatic regions of Chile (Piuquenes at La Andina with Alpine climate, Cauquenes and Caren at El Teniente with Mediterranean climate, and Talabre at the Chuquicamata deposit with hyperarid climate). No clear relationship was found between altitude and isotopic composition. The observed displacement of the tailings pore waters from the local meteoric water line toward higher delta O-18 values (by similar to +2% delta O-18 relative to delta H-2) is partly due to water-rock interaction processes, including hydration and O-isotope exchange with sulfates and Fe(III) oxyhydroxides produced by pyrite oxidation. In most tailings, from the saturated zone toward the surface, isotopically different zones can be distinguished. Zone I is characterized by an upward depletion of H-2 and O-18 in the pore waters from the saturated zone and the lowermost vadose zone, due to ascending diffused isotopically light water triggered by the constant loss of water vapor by evaporation at the surface. In zone II, the capillary flow of a mix of vapor and liquid water causes an evaporative isotopic enrichment in H-2 and O-18. At the top of the tailings in dry climate a zone III between the capillary zone and the surface contains isotopically light diffused and atmospheric water vapor. In temperate climates, the upper part of the profile is affected by recent rainfall and zone III may not differ isotopically from zone II.
Resumo:
The wreck U Pezzo, excavated within the Saint Florent Gulf in northern Corsica was identified as the pink, Saint Etienne, a merchant ship which sank on January 31, 1769. In order to determine the composition of organic materials used to coat the hull or to waterproof different parts of the pink, a study of several samples, using molecular biomarker and carbon isotopic analysis, was initiated. The results revealed that the remarkable yellow coat, covering the outside planks of the ship's bottom under the water line, is composed of sulfur, tallow (of ox and not of cetacean origin) and black pitch which corresponds to a mixture called ``couroi'' or ``stuff'. Onboard ropes had been submitted to a tarring treatment with pitch. Hairs mixed with pitch were identified in samples collected between the two layers of the hull or under the sheathing planking. The study also provides a key model for weathering of pitch, as different degrees of degradation were found between the surface and the heart of several samples. Accordingly, molecular parameters for alteration were proposed. Furthermore novel mixed esters between terpenic and diterpenic alcohols and the free major fatty acids (C(14:0), C(16:0), C(18:0)) were detected in the yellow coat. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
La present tesi proposa una metodologia de disseny conceptual d'estacions depuradores d'aigües residuals (EDAR) mitjançant la combinació del procés de decisió jeràrquic i l'anàlisi de decisions multicriteri. El document s'inicia amb una breu introducció als principals camps abordats pel treball: el disseny dels processos químics en general, el disseny de les estacions depuradores d'aigües residuals en particular, i l'anàlisi de decisions multicriteri aplicada a la gestió ambiental. Seguidament, es fixen els objectius del treball i es descriuen tant la metodologia com el material de suport informàtic utilitzats. Per validar i contrastar la metodologia de disseny presentada, es desenvolupa un cas d'estudi on es porta a terme el disseny conceptual d'una EDAR que presenta els mateixos requeriments que l'EDAR que opera actualment al municipi de Granollers. Inicialment es presenta la informació de partida i tot seguit es defineixen els objectius de disseny, així com el conjunt de criteris que s'utilitzaran per avaluar en quina mesura es compleixen aquests objectius. Els objectius de disseny són de diferents tipus: ambientals, tècnics, socials i econòmics, i el conjunt de criteris utilitzats, concretament 33, també es classifica segons aquestes quatre categories. Cadascun dels criteris presenta un determinat pes d'importància relativa en la presa de decisions. Finalment, es desenvolupa tot el procés de decisió fins a obtenir el disseny complet de l'EDAR. El procés de decisió s'ha dividit en dues parts diferenciades però que alhora s'entrellacen: la línia d'aigua i la línia de fang. El procés de decisió presenta un total de divuit qüestions amb un màxim de quatre alternatives per pregunta (dotze qüestions corresponen a la línia d'aigua, i sis a la línia de fangs). Per solucionar cadascuna d'aquestes qüestions, s'avaluen les alternatives proposades respecte a un conjunt de criteris triats de la llista inicial. Aplicant el procés de decisió multicriteri anomenat SMART (simple multiattribute rating technique), es combinen els resultats de les alternatives respecte a cada criteri, tenint en compte la importància de cada criteri per obtenir un sol valor per alternativa. Per quantificar els criteris referents a l'operació del procés i les de tipus econòmic s'han utilitzat els programes GPS-X i CapdetWorks respectivament. Pel que fa als criteris no quantificats mitjançant aquests programes, s'han resolt de manera qualitativa i mitjançant manuals de disseny i també tenint en compte l'opinió d'experts en aquest camp. L'alternativa que obté un pes més elevat és la recomanada per al procés de decisió. El cas d'estudi finalitza un cop s'obté el disseny complet de l'EDAR. Per integrar tots aquests elements que hem esmentat i donar suport al desenvolupament del procés de decisió s'ha utilitzat el programa DRAMA (Design Rationale Management). A continuació, es fa una anàlisi comparativa entre l'EDAR que hi ha actualment al municipi de Granollers i l'EDAR resultat del cas d'estudi. Es descriu el diagrama de flux que conforma l'EDAR de Granollers i el diagrama de flux de l'EDAR resultat de l'estudi, se'n fa una anàlisi comparativa justificant cadascuna de les decisions preses en el cas d'estudi i, finalment, es fa una discussió de resultats on es reflecteixen els avantatges associats d'aplicar la metodologia de disseny conceptual proposada. Finalment, es presenten les conclusions de la tesi. Els principals resultats de la tesi es van publicar el 2002 a la revista internacional Industrial and Engineering Chemistry Research (N. Vidal, R. Bañares-Alcántara, I. Rodríguez-Roda i M. Poch: "Design of wastewater treatment plants using a conceptual design methodology", Industrial and Engineering Chemistry Research, 41 (20), pàg. 4993-5005) i la continuació de la línia de recerca al Laboratori d'Enginyeria Química i Ambiental de la UdG ha comportat la presentació del treball de recerca de Xavi Flores "Procés de decisió jeràrquic combinat amb anàlisi multicriteri per al suport al disseny conceptual de sistemes de fangs actius d'una estació depuradora d'aigües residuals" i la presentació dels resultats parcials al congrés internacional de la 9th IWA Conference on Design, Operation and Economics of Large Wastewater Treatment, que va tenir lloc el setembre passat a Praga ("Combining hierarchical decision process with multi-criteria analysis for conceptual design of WWTP", X. Flores, N. Vidal, A. Bonmatí, J. B. Copp i I. Rodríguez-Roda).
Resumo:
Seasonal variations in the stable isotopic composition of snow and meltwater were investigated in a sub-arctic, mountainous, but non-glacial, catchment at Okstindan in northern Norway based on analyses of delta(18)O and deltaD. Samples were collected during four field periods (August 1998; April 1999; June 1999 and August 1999) at three sites lying on an altitudinal transect (740-970 m a.s.l.). Snowpack data display an increase in the mean values of delta(18)O (increasing from a mean value of - 13.51 to - 11.49% between April and August), as well as a decrease in variability through the melt period. Comparison with a regional meteoric water line indicates that the slope of the delta(18)O - deltaD line for the snowpacks decreases over the same period, dropping from 7.49 to approximately 6.2. This change points to the role of evaporation in snowpack ablation and is confirmed by the vertical profile of deuterium excess. Snowpack seepage data, although limited, also suggest reduced values of deltaD, as might be associated with local evaporation during meltwater generation. In general, meltwaters were depleted in delta(18)O relative to the source snowpack at the peak of the melt (June), but later in the year (August) the difference between the two was not statistically significant. The diurnal pattern of isotopic composition indicates that the most depleted meltwaters coincide with the peak in temperature and, hence, meltwater production.
Resumo:
Värmedrivna vitvaror eller HWC-maskiner som de kallas av tillverkaren värms med varmt vatten från en cirkulerande krets via en värmeväxlare inbyggd i maskinen, till skillnad från konventionella maskiner som värms med el. Denna teknik skall inte förväxlas med maskiner som är anslutna till varmvattenledningen och fylls på med varmt vatten och som därmed begränsas till disk- och tvätt. Syftet med fjärrvärmedrivna vitvaror är alltså att använda fjärrvärme, som har lägre kvalitet och pris än elenergi för uppvärmning och torkning och på så sätt spara el och utöka fjärrvärmeunderlaget. En jämförelse av koldioxidutsläpp och primärenergianvändning mellan konventionella vitvaror och fjärrvärmedrivna vitvaror visar att både koldioxidutsläpp och primärenergianvändning blir lägre för fjärrvärmedrivna vitvaror om biobränsle anses koldioxidneutralt och den el som ersätts är producerad i kolkraftverk eller gaskombikraftverk. Denna rapport beskriver utveckling och kommersialisering av värmedrivna vitvaror (disk- och tvättmaskiner samt torktumlare och torkskåp) och hur de kan anslutas mot fjärrvärmesystem i olika systemlösningar. Dessutom har de energimässiga och ekonomiska förutsättningarna för tekniken undersökts. Erfarenheterna från fältprovning är dock mycket begränsade, eftersom de byggen där fälttesterna skulle ske försenades. Under 2013 färdigställs ett flerbostadshus med värmedrivna vitvaror i 160 lägenheter i Västerås. De utvecklade maskinernas värmeanvändning som andel av total energianvändning vid 60 graders framledningstemperatur har uppmätts till ca 50 % för diskmaskinen, 67 % för tvättmaskinen, 80 % för torktumlaren och 93 % för torkskåpet. I det studerade flerbostadshuset av passivhusstandard uppgår lasten från värmedrivna vitvaror komfortgolvvärme och handdukstorkar till upp mot 30 % av husets totala värmeanvändning. För småhus är motsvarande siffra upp mot 20 %. Att använda fjärrvärme istället för elvärme till dessa installationer som normalt är elvärmda kan allts minska elbehovet betydligt i lågenergibebyggelse vilket också minskar både koldioxidutsläppen och primärenergianvändningen. Ekonomiska analyser har genomförts för två olika systemkoncept (separat vitvarukrets och Västeråsmodellen) för nybyggda småhusområden och flerfamiljshus där fjärrvärme inte bara används till vitvaror utan också till handdukstorkar och komfortgolvvärme. De ekonomiska analyserna visar att Västeråsmodellen är den mest ekonomiskt intressanta systemlösningen med värmedrivna vitvaror, handdukstork och komfortgolvvärme. I flerfamiljshus kan den vara konkurrenskraftig mot de elvärmda alternativen (konventionellt system med eldrivna vitvaror, komfortgolvvärme och handdukstorkar) om prisskillnaden mellan el och fjärrvärme är större än 0,7 kr/kWh. En parameterstudie visar att kapitalkostnaden blir ganska hög jämfört med energikostnaden, vilket betyder att lång livslängd och många cykler är viktigt för att förbättra de ekonomiska förutsättningarna för värmedrivna vitvaror. För passiva småhus blir kostnaden för Västeråsmodellen med värmedrivna vitvaror, handdukstork och komfortgolvvärme likvärdig med de elvärmda alternativen vid energiprisskillnader på 0,7 kr/kWh inklusive moms, medan det krävs prisskillnader på 0,9 kr/kWh inklusive moms för normalisolerade småhusområden. Sammanfattningsvis kan sägas att i kommuner med ett konkurrenskraftigt fjärrvärmepris finns det viss lönsamhet för hela konceptet enligt Västeråsmodellen med värmedrivna vitvaror, komfortgolvvärme, och handdukstorkar. Om man däremot ser på konkurrensen för enskilda vitvaror är det främst torktumlaren som är konkurrenskraftig i bostäder. Målpriset på 1000 kr extra för värmedrift har inte kunnat uppnås inom projektet för diskmaskiner och tvättmaskiner. Det krävs lägre priser och låga anslutningskostnader för att räkna hem diskmaskinen och tvättmaskinen som enskilda komponenter. Värmedrivna tvättmaskiner och torktumlare är konkurrenskraftiga i flerfamiljstvättstugor. Speciellt i de fall där beläggningen är god och flera maskiner delar på anslutningskostnaden till fjärrvärmecentralen kan värmedrift bli riktigt lönsam. Torkskåpens konkurrenskraft har inte kunnat utvärderas, då priset ännu inte fastställts. Att använda VVC-systemet för värmedistribution till värmedrivna vitvaror kan vara mycket intressant, men det kräver att legionellaproblematiken kan lösas. I nuläget finns ingen lösning som uppfyller formuleringarna i boverkets byggregler. Ett annat distributionssätt som kan vara intressant, men som inte undersökts i studien är att använda VVC för varmvattendistribution och en gemensam radiator- och vitvarukrets med konstant framledningstemperatur. Den aktör som förväntas ha störst ekonomiskt intresse av att tekniken implementeras är sannolikt fjärrvärmebolagen som får sälja mer värme och det ligger därmed främst på deras ansvar att marknadsföra tekniken i mötet med sina kunder.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A saturação de água é a principal propriedade petrofísica para a avaliação de reservatórios de hidrocarbonetos, pois através da análise dos seus valores é definida a destinação final do poço recém perfurado, como produtor ou poço seco. O cálculo da saturação de água para as formações limpas é, comumente, realizado a partir da equação de Archie, que envolve a determinação da resistividade da zona virgem, obtida a partir de um perfil de resistividade profunda e o cálculo de porosidade da rocha, obtida a partir dos perfis de porosidade. A equação de Archie envolve ainda, a determinação da resistividade da água de formação, que normalmente necessita de definição local e correção para a profundidade da formação e da adoção de valores convenientes para os coeficientes de Archie. Um dos métodos mais tradicionais da geofísica de poço para o cálculo da saturação de água é o método de Hingle, particularmente útil nas situações de desconhecimento da resistividade da água de formação. O método de Hingle estabelece uma forma linear para a equação de Archie, a partir dos perfis de resistividade e porosidade e a representa na forma gráfica, como a reta da água ou dos pontos, no gráfico de Hingle, com saturação de água unitária e o valor da resistividade da água de formação é obtido a partir da inclinação da reta da água. Independente do desenvolvimento tecnológico das ferramentas de perfilagem e dos computadores digitais, o geofísico, ainda hoje, se vê obrigado a realizar a interpretação de ábacos ou gráficos, sujeito a ocorrência de erros derivados da sua acuidade visual. Com o objetivo de mitigar a ocorrência deste tipo de erro e produzir uma primeira aproximação para a saturação de água em tempo real de perfilagem do poço, insere-se o trabalho apresentado nesta dissertação, com a utilização de uma conveniente arquitetura de rede neural artificial, a rede competitiva angular, capaz de identificar a localização da reta da água, a partir da identificação de padrões angulares presentes nos dados dos perfis de porosidade e resistividade representados no gráfico de Hingle. A avaliação desta metodologia é realizada sobre dados sintéticos, que satisfazem integralmente a equação de Archie, e sobre dados reais.
Resumo:
Central é um depósito aurífero do campo mineralizado do Cuiú-Cuiú, Província Aurífera do Tapajós, Cráton Amazônico. A zona mineralizada está hospedada em falha e compreende 800m de comprimento na direção NW-SE, seguindo o trend regional da província Tapajós, com largura entre 50 e 70m e profundidade vertical de pelo menos 450m. A mineralização está hospedada em monzogranito datado em 1984±3 Ma e atribuído à Suíte Intrusiva Parauari. Os recursos auríferos preliminarmente definidos são de 18,6t de ouro. A alteração hidrotermal é predominantemente fissural. Sericitização, cloritização, silicificação, carbonatação e sulfetação foram os tipos de alteração identificados. Pirita é o sulfeto principal e os demais sulfetos (calcopirita, esfalerita e galena) estão em fraturas ou nas bordas da pirita. O ouro preenche fraturas da pirita e análises semi-quantitativas detectaram Ag associada ao ouro. Foram identificados três tipos de inclusões fluidas hospedados em veios e vênulas de quartzo. O tipo 1 é o menos abundante e consiste em inclusões fluidas compostas por uma (CO2vapor) ou duas fases (CO2liq-CO2vapor), o tipo 2 tem abundância intermediária e é formado por inclusões fluidas compostas por duas (H2Oliq-CO2liq) ou três fases (H2Oliq-CO2liq-CO2vapor) e o tipo 3 é o mais abundante e consiste em inclusões fluidas compostas por duas fases (H2Oliq- H2Ovapor). O CO2 representa o volátil nas inclusões com CO2 e essas (tipo 1 e 2) foram geradas pelo processo de separação de fases oriundo de um fluido aquo-carbônico. A densidade global (0,33 - 0,80 g/cm³) e a salinidade (11,15 - 2,42 % em peso equivalente de NaCl) desse fluido são baixas a moderadas e a temperatura de homogeneização mostra um máximo em 340ºC. Quanto ao tipo 3, o NaCl é o principal sal, a densidade global está no intervalo de 0,65 a 1,11 g/cm³, a salinidade compreendida entre 1,16 e 13,3 % em peso equivalente de NaCl e a temperatura de homogeneização é bimodal, com picos em 120-140ºC e 180ºC. A composição isotópica das inclusões fluidas presentes no quartzo e do quartzo, calcita e clorita mostram valores de δ18O e δD de +7,8 a +13,6 ‰ e -15 a -35 ‰, respectivamente. Os valores de δ34S na pirita são de +0,5 a +4,0 ‰ e δ13C na calcita e CO2 de inclusões fluidas de -18 a -3,7 ‰. Os valores de δ18OH2O e de δDH2O no quartzo e inclusões fluidas, respectivamente, plotam no campo das águas metamórficas, com um desvio em direção à linha da água meteórica. Considerando a inexistência de evento metamórfico na região do Tapajós à época da mineralização, o sistema hidrotermal responsável pela mineralização no Central, inicialmente, deu-se a partir de fluidos aquo-carbônicos magmático-hidrotermais, exsolvidos por magma félsico relacionado com a fase mais tardia de evolução da Suíte Intrusiva Parauari. As inclusões aquo-carbônicas e carbônicas formaram-se nessa etapa, predominantemente em torno de 340°C. A contínua exsolução de fluido pelo magma levou ao empobrecimento em CO2 nas fases mais tardias e, com o resfriamento do fluido, as inclusões aquosas passaram a predominar. A partir daí o sistema pode ter interagido com água meteórica, responsável pelo aprisionamento da maior parte das inclusões aquosas de mais baixa temperatura. É possível que parte das inclusões aquosas (as de maior temperatura) represente a mistura local dos fluidos de origens distintas. Essas observações e interpretações permitem classificar Central como um depósito de ouro magmático-hidrotermal relacionado à fase final da formação da Suíte Intrusiva Parauari.
Resumo:
Introduction and Objective: Microorganisms are responsible for multiple infections and pathologies; this is why it is important to control microbes that can be found in the triple syringe used for irrigation in different dental procedures. The aim of this study was to identify cultivable species of microbes (fungus and bacteria) found in some dental units water lines of a private dental clinic from Medellín, Colombia. Materials and Methods: Random samples were taken from 11 chairs from a total of 89; a sample of water of 500ml was collected from the triple syringe of each selected chair. The study aim to search for the presence of total coliforms, filamentous fungi and leavened Results: the average presence of microorganisms was between 40CFU and more of 200 CFU. Microorganisms such as Aeromona salmonicida, Actinobacilus sp and Pseudomona maltophil were isolated. No total coliforms neither fecal coliforms were found. Conclusions: the high levels of contamination suggest that there is a mature biofilm in somewhere of the dental unit water line, but the absence of total and fecalis coliforms suggest that the water had been treated.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Geociências e Meio Ambiente - IGCE