877 resultados para Wastewater quality variables


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Four (4) wastewater quality variables: chemical oxygen demand (COD), total solid (TS), total dissolved solid (TDS), and total suspended solid (TSS) were determined. Analysed samples comprises of raw influent and effluents entering and leaving the stabilisation ponds. Significant reduction in variables were obtained, maximum and minimum values obtained for COD were 917mg/l (anaerobic pond), and 13mg/l (maturation pond). For TS, TDS and TSS, maximum and minimum values obtained were 14,420mg/l, 9,180mg/l, 5,240mg/l and 3,398mg/l, 3,120mg/l, 278mg/l respectively. Removal efficiencies recorded for parameters in final effluent (maturation pond) were 98.55% (COD), 76.44% (TS), 66.01% (TDS), and 94.69% (TSS) respectively.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Despite its potential multiple contributions to sustainable policy objectives, urban transit is generally not widely used by the public in terms of its market share compared to that of automobiles, particularly in affluent societies with low-density urban forms like Australia. Transit service providers need to attract more people to transit by improving transit quality of service. The key to cost-effective transit service improvements lies in accurate evaluation of policy proposals by taking into account their impacts on transit users. If transit providers knew what is more or less important to their customers, they could focus their efforts on optimising customer-oriented service. Policy interventions could also be specified to influence transit users’ travel decisions, with targets of customer satisfaction and broader community welfare. This significance motivates the research into the relationship between urban transit quality of service and its user perception as well as behaviour. This research focused on two dimensions of transit user’s travel behaviour: route choice and access arrival time choice. The study area chosen was a busy urban transit corridor linking Brisbane central business district (CBD) and the St. Lucia campus of The University of Queensland (UQ). This multi-system corridor provided a ‘natural experiment’ for transit users between the CBD and UQ, as they can choose between busway 109 (with grade-separate exclusive right-of-way), ordinary on-street bus 412, and linear fast ferry CityCat on the Brisbane River. The population of interest was set as the attendees to UQ, who travelled from the CBD or from a suburb via the CBD. Two waves of internet-based self-completion questionnaire surveys were conducted to collect data on sampled passengers’ perception of transit service quality and behaviour of using public transit in the study area. The first wave survey is to collect behaviour and attitude data on respondents’ daily transit usage and their direct rating of importance on factors of route-level transit quality of service. A series of statistical analyses is conducted to examine the relationships between transit users’ travel and personal characteristics and their transit usage characteristics. A factor-cluster segmentation procedure is applied to respodents’ importance ratings on service quality variables regarding transit route preference to explore users’ various perspectives to transit quality of service. Based on the perceptions of service quality collected from the second wave survey, a series of quality criteria of the transit routes under study was quantitatively measured, particularly, the travel time reliability in terms of schedule adherence. It was proved that mixed traffic conditions and peak-period effects can affect transit service reliability. Multinomial logit models of transit user’s route choice were estimated using route-level service quality perceptions collected in the second wave survey. Relative importance of service quality factors were derived from choice model’s significant parameter estimates, such as access and egress times, seat availability, and busway system. Interpretations of the parameter estimates were conducted, particularly the equivalent in-vehicle time of access and egress times, and busway in-vehicle time. Market segmentation by trip origin was applied to investigate the difference in magnitude between the parameter estimates of access and egress times. The significant costs of transfer in transit trips were highlighted. These importance ratios were applied back to quality perceptions collected as RP data to compare the satisfaction levels between the service attributes and to generate an action relevance matrix to prioritise attributes for quality improvement. An empirical study on the relationship between average passenger waiting time and transit service characteristics was performed using the service quality perceived. Passenger arrivals for services with long headways (over 15 minutes) were found to be obviously coordinated with scheduled departure times of transit vehicles in order to reduce waiting time. This drove further investigations and modelling innovations in passenger’ access arrival time choice and its relationships with transit service characteristics and average passenger waiting time. Specifically, original contributions were made in formulation of expected waiting time, analysis of the risk-aversion attitude to missing desired service run in the passengers’ access time arrivals’ choice, and extensions of the utility function specification for modelling passenger access arrival distribution, by using complicated expected utility forms and non-linear probability weighting to explicitly accommodate the risk of missing an intended service and passenger’s risk-aversion attitude. Discussions on this research’s contributions to knowledge, its limitations, and recommendations for future research are provided at the concluding section of this thesis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The properties and toxicity of untreatedwastewater at Davis Station, East Antarctica,were investigated to inform decisions regarding the appropriate level of treatment for local discharge purposes and more generally, to better understand the risk associated with dispersal and impact of wastewaters in Antarctica. Suspended solids, nutrients (nitrogen, phosphorus), biological oxygen demand (BOD), metals, organic contaminants, surfactants and microbiological load were measured at various locations throughout the wastewater discharge system. Wastewater quality and properties varied greatly between buildings on station, each ofwhich has separate holding tanks. Nutrients, BOD and settleable solid levelswere higher than standard municipal wastewaters. Microbiological loads were typical of untreated wastewater. Contaminants detected in the wastewater included metals and persistent organic compounds, mainly polybrominated diphenyl ethers (PBDEs). The toxicity of wastewater was also investigated in laboratory bioassays using two local Antarctic marine invertebrates, the amphipod Paramoera walkeri and the microgastropod Skenella paludionoides. Animals were exposed to a range of wastewater concentrations from3% to 68% (test 1) or 63% (test 2) over 21 days with survival monitored daily. Significant mortality occurred in all concentrations of wastewater after 14 to 21 days, and at higher concentrations (50–68% wastewater) mortality occurred after only one day. Results indicate that the local receiving marine environment at Davis Station is at risk from existing wastewater discharges, and that advanced treatment is required both to remove contaminants shown to cause toxicity to biota, as well as to reduce the environmental risks associated with non-native micro-organisms in wastewater.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Mixed rearing of tilapia (Genetically Improved Farmed Tilapia, GIFT) with shrimp (Penaeus monodon) in brackishwater rice-shrimp system was assessed for its impact on dry season's shrimp production. The experiment was conducted in pre-selected farmer's field located at Paikgacha Upazila of Khulna district and designed with three different densities (treatment) of GIFT, viz, 0.3, 0.4 and 0.5/m² with a constant stocking density of shrimp at 3/m². Each treatment had three replications. There had a set of control treatment where GIFT was not stocked. Results of the experiment revealed that tilapia did not exert any significant effect (p>0.05) on the water quality variables, even on survival rate of shrimp (p>0.05) under farm level condition in rice-shrimp rotational system, but a density dependent negative effect (P<0.05) on the growth of shrimp led apparently lower production rate of shrimp. Though tilapia provided the major augment of total production (p<0.05) in the respective treatments than in monoculture of shrimp, but not that of the economic return. However, economic loss due to sudden shrimp crop failure might be partially minimized by the tilapia crop.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A self-organizing map (SOM) was used to cluster the water quality data of Xiangxi River in the Three Gorges Reservoir region. The results showed that 81 sampling sites could be divided into several groups representing different land use types. The forest dominated region had low concentrations of most nutrient variables except COD, whereas the agricultural region had high concentrations of NO3N, TN, Alkalinity, and Hardness. The sites downstream of an urban area were high in NH3N, NO2N, PO4P and TP. Redundancy analysis was used to identify the individual effects of topography and land use on river water quality. The results revealed that the watershed factors accounted for 61.7% variations of water quality in the Xiangxi River. Specifically, topographical characteristics explained 26.0% variations of water quality, land use explained 10.2%, and topography and land use together explained 25.5%. More than 50% of the variation in most water quality variables was explained by watershed characteristics. However, water quality variables which are strongly influenced by urban and industrial point source pollution (NH3N, NO2N, PO4P and TP) were not as well correlated with watershed characteristics.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The relationships between wheat protein quality and baking properties of 20 flour samples were studied for two breadmaking processes; a hearth bread test and the Chorleywood Bread Process (CBP). The strain hardening index obtained from dough inflation measurements, the proportion of unextractable polymeric protein, and mixing properties were among the variables found to be good indicators of protein quality and suitable for predicting potential baking quality of wheat flours. By partial least squares regression, flour and dough test variables were able to account for 71-93% of the variation in crumb texture, form ratio and volume of hearth loaves made using optimal mixing and fixed proving times. These protein quality variables were, however, not related to the volume of loaves produced by the CBP using mixing to constant work input and proving to constant height. On the other hand, variation in crumb texture of CBP loaves (54-55%) could be explained by protein quality. The results underline that the choice of baking procedure and loaf characteristics is vital in assessing the protein quality of flours. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Biological nitrogen removal is an important task in the wastewater treatment. However, the actual removal of total nitrogen (TN) in the wastewater treatment plant (WWTP) is often unsatisfactory due to several causes, one of which is the insufficient availability of carbon source. One possible approach to improve the nitrogen removal therefore is addition of external carbon source, while the amount of which is directly related to operation cost of a WWTP. It is obviously necessary to determine the accurate amount of addition of external carbon source according to the demand depending on the influent wastewater quality. This study focused on the real-time control of external carbon source addition based on the on-line monitoring of influent wastewater quality. The relationship between the influent wastewater quality (specifically the concentration of COD and ammonia) and the demand of carbon source was investigated through experiments on a pilot-scale A/O reactor (1m3) at the Nanjing WWTP, China. The minimum doses of carbon source addition at different situations of influent wastewater quality were determined to ensure the effluent wastewater quality meets the discharge standard. The obtained relationship is expected to be applied in the full-scale WWTPs. .

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Citrus sudden death (CSD) has greatly affected sweet orange cultivars grafted on Rangpur lime in São Paulo and Minas Gerais States, Brazil. To characterize and quantify CSD damage, fruit yield and quality were assessed in each combination of sweet orange cultivar (Hamlin, Pera, Natal, and Valencia), age class (3 to 5, 6 to 10, and 11 to 15 years old), and CSD severity class (0 = no symptom, 1 = initial symptoms, and 2 = severe symptoms). For each combination, 10 trees were harvested and 20 fruit were taken for quality analysis. Damage was characterized by reduc_ tion of: (i) total weight of fruit/tree (36 and 67% for severity class 1 and 2, respectively), (ii) number of fruit/tree (27 and 55%), (iii) fruit size (13 and 25% in diameter and height [stem to styler distance]), (iv) fruit weight (32 and 56%), (v) total soluble solids (TSS)/fruit (18 and 42%), and increase of (vi) Brix (14 and 34%), (vii) acidity (16 and 41%), and (viii) TSS/90-1b. box (21 and 33%). There was no alteration on Brix/acidity ratio and percentage of juice on fruit of affected trees. Sweet orange cultivars did not differ in percentage of reduction or increase of all yield and quality variables, with the exception of Pera, which expressed increases of Brix and acidity. For more severe affected trees, the youngest plants showed a higher reduction in fruit number/tree, whereas plants 6 to 10 years old showed a higher increase in fruit acidity and TSS/box. However, no differences in percentage of reduction or increase for other variables were observed among different age classes. The damage to the above probably was associated with reduced water absorption capacity of CSD-affected trees.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study aims to assess the potential for industrial reuse of textile wastewater, after passing through a physical and chemical pretreatment, into denim washing wet processing operations in an industrial textile laundry, with no need for complementary treatments and dilutions. The methodology and evaluation of the proposed tests were based on the production techniques used in the company and upgraded for the experiments tested. The characterization of the treated effluent for 16 selected parameters and the development of a monitoring able to tailor the treated effluent for final disposal in accordance with current legislation was essential for the initiation of testing for reuse. The parameters color, turbidity, SS and pH used were satisfactory as control variables and presents simple determination methods. The denim quality variables considered were: color, odor, appearance and soft handle. The tests were started on a pilot scale following complexity factors attributed to the processes, in denim fabric and jeans, which demonstrated the possibility of reuse, because there was no interference in the processes and at quality of the tested product. Industrial scale tests were initiated by a step control that confirmed the methodology efficiency applied to identify the possibility of reuse by tests that precede each recipe to be processed. 556 replicates were performed in production scale for 47 different recipes of denim washing. The percentage of water reuse was 100% for all processes and repetitions performed after the initial adjustment testing phase. All the jeans were framed with the highest quality for internal control and marketed, being accepted by contractors. The full-scale use of treated wastewater, supported by monitoring and evaluation and control methodology suggested in this study, proved to be valid in textile production, not given any negative impact to the quality the produced jeans under the presented conditions. It is believed that this methodology can be extrapolated to other laundries to determine the possibility of reuse in denim washing wet processing with the necessary modifications to each company.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Channel catfish ponds are treated with salt (sodium chloride) to increase chloride concentration and prevent nitrite toxicity in fish. A survey indicated that most farmers try to maintain chloride concentration of 50 to 100 mg/L in ponds by annual salt applications. Averages and standard deviations for selected water quality variables in salt-treated ponds were as follows: chloride, 87.2 ± 37.5 mg/L; total dissolved solids (TDS), 336 ± 96 mg/L; specific conductance, 512 ± 164 μmhos/cm. Maximum values were 189 mg/L for chloride, 481 mg/L for TDS, and 825 μmhos/cm for specific conductance. Good correlations between specific conductance values and both chloride and TDS concentrations suggest that specific conductance can be a rapid method for estimating concentrations of these two variables in surface water. The maximum limit for chloride concentration in Alabama streams allowed by the Alabama Department of Environmental Management is 230 mg/L. The usual recommended upper limit of TDS for protection of aquatic life in freshwater streams is 1,000 mg/L. Based on the observed relationship between TDS concentration and specific conductance in Alabama catfish ponds, 1,000 mg/L TDS corresponds to 1,733 μmhos/cm specific conductance. It is unlikely that effluents from salt-treated catfish ponds would violate the in-stream chloride standard of 230 mg/L or harm aquatic life in streams. Nevertheless, chloride concentrations in ponds should be measured before salt application as a safe guard against excessive salt application and chloride concentrations above the in-stream chloride standard.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background The release of quality data from acute care hospitals to the general public is based on the aim to inform the public, to provide transparency and to foster quality-based competition among providers. Due to the expected mechanisms of action and possibly the adverse consequences of public quality comparison, it is a controversial topic. The perspective of physicians and nurses is of particular importance in this context. They are mainly responsible for the collection of quality-control data, and are directly confronted with the results of public comparison. The research focus of this qualitative study was to discover what the views and opinions of the Swiss physicians and nurses were regarding these issues. It was investigated as to how the two professional groups appraised the opportunities as well as the risks of the release of quality data in Switzerland. Methods A qualitative approach was chosen to answer the research question. For data collection, four focus groups were conducted with physicians and nurses who were employed in Swiss acute care hospitals. Qualitative content analysis was applied to the data. Results The results revealed that both occupational groups had a very critical and negative attitude regarding the recent developments. The perceived risks were dominating their view. In summary, their main concerns were: the reduction of complexity, the one-sided focus on measurable quality variables, risk selection, the threat of data manipulation and the abuse of published information by the media. An additional concern was that the impression is given that the complex construct of quality can be reduced to a few key figures, and it that it is constructed from a false message which then influences society and politics. This critical attitude is associated with the different value system and the professional self-concept that both physicians and nurses have, in comparison to the underlying principles of a market-based economy and the economic orientation of health care business. Conclusions The critical and negative attitude of Swiss physicians and nurses must, under all conditions, be heeded to and investigated regarding its impact on work motivation and identification with the profession. At the same time, the two professional groups are obligated to reflect upon their critical attitude and take a proactive role in the development of appropriate quality indicators for the publication of quality data in Switzerland.