927 resultados para WIND GENERATORS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last 15 years, the use of doubly fed induction machines in modern variable-speed wind turbines has increased rapidly. This development has been driven by the cost reduction as well as the low-loss generation of Insulated Gate Bipolar Transistors (IGBT). According to new grid code requirements, wind turbines must remain connected to the grid during grid disturbances. Moreover, they must also contribute to voltage support during and after grid faults. The crowbar system is essential to avoid the disconnection of the doubly fed induction wind generators from the network during faults. The insertion of the crowbar in the rotor circuits for a short period of time enables a more efficient terminal voltage control. As a general rule, the activation and the deactivation of the crowbar system is based only on the DC-link voltage level of the back-to-back converters. In this context, the authors discuss the critical rotor speed to analyze the instability of doubly fed induction generators during grid faults.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among all the different types of electric wind generators, those that are based on doubly fed induction generators, or DFIG technology, are the most vulnerable to grid faults such as voltage sags. This paper proposes a new control strategy for this type of wind generator, that allows these devices to withstand the effects of a voltage sag while following the new requirements imposed by grid operators. This new control strategy makes the use of complementary devices such as crowbars unnecessary, as it greatly reduces the value of currents originated by the fault. This ensures less costly designs for the rotor systems as well as a more economic sizing of the necessary power electronics. The strategy described here uses an electric generator model based on space-phasor theory that provides a direct control over the position of the rotor magnetic flux. Controlling the rotor magnetic flux has a direct influence on the rest of the electrical variables enabling the machine to evolve to a desired work point during the transient imposed by the grid disturbance. Simulation studies have been carried out, as well as test bench trials, in order to prove the viability and functionality of the proposed control strategy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Harmonic distortion on voltages and currents increases with the increased penetration of Plug-in Electric Vehicle (PEV) loads in distribution systems. Wind Generators (WGs), which are source of harmonic currents, have some common harmonic profiles with PEVs. Thus, WGs can be utilized in careful ways to subside the effect of PEVs on harmonic distortion. This work studies the impact of PEVs on harmonic distortions and integration of WGs to reduce it. A decoupled harmonic three-phase unbalanced distribution system model is developed in OpenDSS, where PEVs and WGs are represented by harmonic current loads and sources respectively. The developed model is first used to solve harmonic power flow on IEEE 34-bus distribution system with low, moderate, and high penetration of PEVs, and its impact on current/voltage Total Harmonic Distortions (THDs) is studied. This study shows that the voltage and current THDs could be increased upto 9.5% and 50% respectively, in case of distribution systems with high PEV penetration and these THD values are significantly larger than the limits prescribed by the IEEE standards. Next, carefully sized WGs are selected at different locations in the 34-bus distribution system to demonstrate reduction in the current/voltage THDs. In this work, a framework is also developed to find optimal size of WGs to reduce THDs below prescribed operational limits in distribution circuits with PEV loads. The optimization framework is implemented in MATLAB using Genetic Algorithm, which is interfaced with the harmonic power flow model developed in OpenDSS. The developed framework is used to find optimal size of WGs on the 34-bus distribution system with low, moderate, and high penetration of PEVs, with an objective to reduce voltage/current THD deviations throughout the distribution circuits. With the optimal size of WGs in distribution systems with PEV loads, the current and voltage THDs are reduced below 5% and 7% respectively, which are within the limits prescribed by IEEE.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper presents a robust voltage control scheme for fixed-speed wind generators using a static synchronous compensator (STATCOM) controller. To enable a linear and robust control framework with structured uncertainty, the overall system is represented by a linear part plus a nonlinear part that covers an operating range of interest required to ensure stability during severe low voltages. The proposed methodology is flexible and readily applicable to larger wind farms of different configurations. The performance of the control strategy is demonstrated on a two area test system. Large disturbance simulations demonstrate that the proposed controller enhances voltage stability as well as transient stability of induction generators during low voltage ride through (LVRT) transients and thus enhances the LVRT capability. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The main aims of this work are the development and the validation of one generic algorithm to provide the optimal control of small power wind generators. That means up to 40 kW and blades with fixed pitch angle. This algorithm allows the development of controllers to fetch the wind generators at the desired operational point in variable operating conditions. The problems posed by the variable wind intensity are solved using the proposed algorithm. This is done with no explicit measure of the wind velocity, and so no special equipment or anemometer is required to compute or measure the wind velocity.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The complexity of power systems has increased in recent years due to the operation of existing transmission lines closer to their limits, using flexible AC transmission system (FACTS) devices, and also due to the increased penetration of new types of generators that have more intermittent characteristics and lower inertial response, such as wind generators. This changing nature of a power system has considerable effect on its dynamic behaviors resulting in power swings, dynamic interactions between different power system devices, and less synchronized coupling. This paper presents some analyses of this changing nature of power systems and their dynamic behaviors to identify critical issues that limit the large-scale integration of wind generators and FACTS devices. In addition, this paper addresses some general concerns toward high compensations in different grid topologies. The studies in this paper are conducted on the New England and New York power system model under both small and large disturbances. From the analyses, it can be concluded that high compensation can reduce the security limits under certain operating conditions, and the modes related to operating slip and shaft stiffness are critical as they may limit the large-scale integration of wind generation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of this paper is to suggest a simple methodology to be used by renewable power generators to bid in Spanish markets in order to minimize the cost of their imbalances. As it is known, the optimal bid depends on the probability distribution function of the energy to produce, of the probability distribution function of the future system imbalance and of its expected cost. We assume simple methods for estimating any of these parameters and, using actual data of 2014, we test the potential economic benefit for a wind generator from using our optimal bid instead of just the expected power generation. We find evidence that Spanish wind generators savings would be from 7% to 26%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Permanent magnet synchronous machines with fractional-slot non-overlapping windings (FSPMSM), also known as tooth-coil winding permanent magnet synchronous machines (TCW PMSM), have been under intensive research during the latest decade. There are many optimization routines explained and implemented in the literature in order to improve the characteristics of this machine type. This paper introduces a new technique for torque ripple minimization in TCW PMSM. The source of torque harmonics is also described. The low order torque harmonics can be harmful for a variety of applications, such as direct drive wind generators, direct drive light vehicle electrical motors, and for some high precision servo applications. The reduction of the torque ripple harmonics with the lowest orders (6th and 12th) is realized by machine geometry optimization technique using finite element analysis (FEA). The presented optimization technique includes the stator geometry adjustment in TCW PMSMs with rotor surface permanent magnets and with rotor embedded permanent magnets. Influence of the permanent magnet skewing on the torque ripple reduction and cogging torque elimination was also investigated. It was implemented separately and together with the stator optimization technique. As a result, the reduction of some torque ripple harmonics was attained.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

At present, the electricity generation through wind energy has an importance growing in the world, with the existence of very large plans for future wind power installation worldwide. Thus, the increasing the electricity generation through wind power requires, more and more, analysis of studies of interaction between wind parks and electric power systems. This paper has as purposes to implement equivalent models for synchronous wind generators to represent a wind park in ATP program and to check behavior of the models through simulations. Simulations with applications of faults were achieved to evaluate the behavior of voltages of system for each equivalent model, through comparisons between the results of models proposed, to verify if the differences obtained allows the adoption of the simplest model

Relevância:

60.00% 60.00%

Publicador:

Resumo:

No presente trabalho é avaliada uma metodologia de injeção de potência reativa em redes elétricas durante afundamentos de tensão provocados por curto-circuito, em parques eólicos interligados, adotada em alguns países com maturidade tecnológica na produção de energia eólica. Nos estudos desenvolvidos, foi utilizado o aerogerador síncrono a imã permanente com conversor pleno em função da grande controlabilidade do conversor interligado à rede e por possuir elevada capacidade de fornecimento de potência reativa, comparada a outras tecnologias de aerogeradores. No Brasil, os requisitos de interligação de parques eólicos as redes elétricas, definido pelo Operador Nacional do Sistema, ainda não estipula a necessidade de adoção de tal metodologia durante defeitos na rede elétrica, apenas especifica a curva de capacidade de afundamentos de tensão que os aerogeradores devem seguir para evitar o desligamento frente a afundamentos de tensão. Os critérios de proteção do aerogerador síncrono são avaliados a partir de simulações de curto-circuito em uma rede de teste adotando-se os requisitos do Brasil, sem injeção de potência reativa, sendo comparados com o de outros países que adotam curvas de injeção de potência reativa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este trabajo tiene por objetivo el estudio de ahorro energético en una explotación ganadera. Para ello, se contempla la posibilidad de sustituir los sistemas actuales por otros alimentados de energía solar, geotérmica o eólica. La energía obtenida a partir de la producción de metano a través de la utilización de los purines no se contempla, debido a que son utilizados como abono en las parcelas colindantes. PUNTOS TRATADOS Se parte de que, en la explotación, la calefacción es de gas natural y la electricidad es generada por un grupo electrógeno. Estudio de la irradiancia de la zona y de la cantidad de paneles solares y baterías necesarios para hacer la explotación ganadera autosuficiente. Estudio del potencial eólico de la zona y de la cantidad de aerogeneradores y baterías necesarios para hacer la explotación ganadera autosuficiente. Estudio del potencial calorífico de la zona y de la cantidad de tubos, bombas de calor y baterías necesarios para hacer la explotación ganadera autosuficiente. Cálculo de los costes de la instalación solar, eólica y geotérmica. Comparación de los resultados obtenidos anteriormente y breve discusión sobre el sistema elegido. ABSTRACT OBJETIVES This job has got like objective the energetic saving study in a cattle exploitation. For it, it is contemplated the possibility of replacing the current systems with others fed on solar, wind and geothermal power. Energy obtained across production of methane across animal organic wastes it is not contemplated, because they are used as fertilizer on adjacent smallholdings. TREATED POINTS It is parted of that, in the exploitation, heating is propane and electricity is generated by an electrical generator. Study about irradiance on the place and quantity of solar panels and batteries to doing self-sufficient the cattle exploitation. Study about wind potential on the place and quantity of wind generators and batteries to doing self-sufficient the cattle exploitation. Study about calorific potential into ground and quantity of pipes, heat pumps and batteries to doing self-sufficient the cattle exploitation. Calculation about solar, wind and geothermal installation costs. Comparison about results have been obtained and brief discussion about chosen system

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Advancements in power electronic semiconductor switching devices have lead to significantly faster switching times. In motor and generator applications, the fast switching times of pulse width modulated (PWM) inverters lead to overvoltages caused by voltage reflections with shorter and shorter cables. These excessive overvoltages may lead to a failure of the electrical machine in a matter of months. In this thesis, the causes behind the overvoltage phenomenon as well as its different mitigation techniques are studied. The most suitable techniques for mitigating the overvoltage phenomenon in wind power generator applications are chosen based on both simulations and actual measurements performed on a prototype. An RC filter at the terminals of the electrical machine and an inverter output filter designed to reduce the rise and fall times of voltage pulses are presented as a solution to the overvoltage problem. The performance and losses of both filter types are analysed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Na sequência da integração da energia eólica em larga escala foram estabelecidos códigos de rede pelos vários operadores de sistema, exigindo que os parques eólicos permaneçam em serviço durante e após a ocorrência de defeitos na rede a montante. Nos parques eólicos equipados com sistemas de velocidade constante este requisito pode ser assegurado pela instalação, no ponto de interligação à rede, de equipamento de compensação dinâmica de potência reactiva, controlado como fonte de tensão, sendo as funções de controlo baseadas em medidas efectuadas no ponto de interligação relativamente às componentes directas da tensão e da corrente. Como a adopção deste tipo de soluções externas é adequada ao funcionamento do sistema em regime equilibrado, este artigo foca a avaliação do desempenho da solução no caso da ocorrência de defeitos assimétricos. Os resultados obtidos através das simulações dinâmicas evidenciam o aparecimento de sobre tensões nas fases não afectadas pelo defeito que poderão colocar o parque eólico fora de serviço.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The increasing penetration of wind energy into power systems has pushed grid operators to set new requirements for this kind of generating plants in order to keep acceptable and reliable operation of the system. In addition to the low voltage ride through capability, wind farms are required to participate in voltage support, stability enhancement and power quality improvement. This paper presents a solution for wind farms with fixed-speed generators based on the use of STATCOM with braking resistor and additional series impedances, with an adequate control strategy. The focus is put on guaranteeing the grid code compliance when the wind farm faces an extensive series of grid disturbances.