984 resultados para Voltage quality


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Single phase distributed energy resources (DERs) can cause voltage rise along distribution feeder and power imbalance among the phases. Usually transformer tap setting are used to mitigate voltage drop along feeders. However this can aggravate the voltage rise problem when DERs are connected. Moreover if the power generation in a phase is more than its load demand, the excess power in that phase will be fed back to the transmission network. In this paper, a unified power quality compensator (UPQC) has been utilized to alleviate the voltage quality excess power circulation problems. Through analysis and simulation results, the mode of operation of UPQC is highlighted. The proposals are validated through extensive digital computer simulation studies using PSCAD and MATLAB.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A probabilistic method is proposed to evaluate voltage quality of grid-connected photovoltaic (PV) power systems. The random behavior of solar irradiation is described in statistical terms and the resulting voltage fluctuation probability distribution is then derived. Reactive power capabilities of the PV generators are then analyzed and their operation under constant power factor mode is examined. By utilizing the reactive power capability of the PV-generators to the full, it is shown that network voltage quality can be greatly enhanced.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The research activity carried out during the PhD course in Electrical Engineering belongs to the branch of electric and electronic measurements. The main subject of the present thesis is a distributed measurement system to be installed in Medium Voltage power networks, as well as the method developed to analyze data acquired by the measurement system itself and to monitor power quality. In chapter 2 the increasing interest towards power quality in electrical systems is illustrated, by reporting the international research activity inherent to the problem and the relevant standards and guidelines emitted. The aspect of the quality of voltage provided by utilities and influenced by customers in the various points of a network came out only in recent years, in particular as a consequence of the energy market liberalization. Usually, the concept of quality of the delivered energy has been associated mostly to its continuity. Hence the reliability was the main characteristic to be ensured for power systems. Nowadays, the number and duration of interruptions are the “quality indicators” commonly perceived by most customers; for this reason, a short section is dedicated also to network reliability and its regulation. In this contest it should be noted that although the measurement system developed during the research activity belongs to the field of power quality evaluation systems, the information registered in real time by its remote stations can be used to improve the system reliability too. Given the vast scenario of power quality degrading phenomena that usually can occur in distribution networks, the study has been focused on electromagnetic transients affecting line voltages. The outcome of such a study has been the design and realization of a distributed measurement system which continuously monitor the phase signals in different points of a network, detect the occurrence of transients superposed to the fundamental steady state component and register the time of occurrence of such events. The data set is finally used to locate the source of the transient disturbance propagating along the network lines. Most of the oscillatory transients affecting line voltages are due to faults occurring in any point of the distribution system and have to be seen before protection equipment intervention. An important conclusion is that the method can improve the monitored network reliability, since the knowledge of the location of a fault allows the energy manager to reduce as much as possible both the area of the network to be disconnected for protection purposes and the time spent by technical staff to recover the abnormal condition and/or the damage. The part of the thesis presenting the results of such a study and activity is structured as follows: chapter 3 deals with the propagation of electromagnetic transients in power systems by defining characteristics and causes of the phenomena and briefly reporting the theory and approaches used to study transients propagation. Then the state of the art concerning methods to detect and locate faults in distribution networks is presented. Finally the attention is paid on the particular technique adopted for the same purpose during the thesis, and the methods developed on the basis of such approach. Chapter 4 reports the configuration of the distribution networks on which the fault location method has been applied by means of simulations as well as the results obtained case by case. In this way the performance featured by the location procedure firstly in ideal then in realistic operating conditions are tested. In chapter 5 the measurement system designed to implement the transients detection and fault location method is presented. The hardware belonging to the measurement chain of every acquisition channel in remote stations is described. Then, the global measurement system is characterized by considering the non ideal aspects of each device that can concur to the final combined uncertainty on the estimated position of the fault in the network under test. Finally, such parameter is computed according to the Guide to the Expression of Uncertainty in Measurements, by means of a numeric procedure. In the last chapter a device is described that has been designed and realized during the PhD activity aiming at substituting the commercial capacitive voltage divider belonging to the conditioning block of the measurement chain. Such a study has been carried out aiming at providing an alternative to the used transducer that could feature equivalent performance and lower cost. In this way, the economical impact of the investment associated to the whole measurement system would be significantly reduced, making the method application much more feasible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Four-leg dc-ac power converters are widely used for the power grids to manage grid voltage unbalance caused by the interconnection of single-phase or three-phase unbalanced loads. These converters can further be connected in parallel to increase the overall power rating. The control of these converters poses a particular challenge if they are placed far apart with no links between them (e.g., in islanded microgrids). This challenge is studied in this paper with each four-leg converter designed to have improved common current sharing and selective voltage-quality enhancement. The common current sharing, including zero sequence component, is necessary since loads are spread over the microgrid and they are hence the common responsibility of all converters. The voltage-quality enhancement consideration should however be more selective since different loads have different sensitivity levels towards voltage disturbances. Converters connected to the more sensitive load buses should therefore be selectively triggered for compensation when voltage unbalances at their protected buses exceed the predefined thresholds. The proposed scheme is therefore different from conventional centralized schemes protecting only a common bus. Simulation and experimental results obtained have verified the effectiveness of the proposed scheme when applied to a four-wire islanded microgrid.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this thesis various schemes using custom power devices for power quality improvement in low voltage distribution network are studied. Customer operated distributed generators makes a typical network non-radial and affect the power quality. A scheme considering different algorithm of DSTATCOM is proposed for power circulation and islanded operation of the system. To compensate reactive power overflow and facilitate unity power factor, a UPQC is introduced. Stochastic analysis is carried out for different scenarios to get a comprehensive idea about a real life distribution network. Combined operation of static compensator and voltage regulator is tested for the optimum quality and stability of the system.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

There is a trade off between a number of output voltage levels and the reliability and efficiency of a multilevel converter. A new configuration of diode-clamped multilevel inverters with a different combination of DC link capacitors voltage has been proposed in this paper. Two different symmetrical and asymmetrical unequal arrangements for a four-level diode-clamped inverter have been compared, in order to find an optimum arrangement with lower switching losses and optimised output voltage quality. The simulation and hardware results for a four-level inverter show that the asymmetrical configuration can obtain more output voltage levels with the same number of components compared with a conventional four-level inverter and this will lead to the reduction of the harmonic content of the output voltage. A new family of multi-output DC-DC converters with a simple control strategy has been utilised as a front-end converter to supply the DC link capacitor voltages for the optimised configuration.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Multilevel converters are used in high power and high voltage applications due to their attractive benefits in generating high quality output voltage. Increasing the number of voltage levels can lead to a reduction in lower order harmonics. Various modulation and control techniques are introduced for multilevel converters like Space Vector Modulation (SVM), Sinusoidal Pulse Width Modulation (SPWM) and Harmonic Elimination (HE) methods. Multilevel converters may have a DC link with equal or unequal DC voltages. In this paper a new modulation technique based on harmonic elimination method is proposed for those multilevel converters that have unequal DC link voltages. This new technique has better effect on output voltage quality and less Total Harmonic Distortion (THD) than other modulation techniques. In order to verify the proposed modulation technique, MATLAB simulations are carried out for a single-phase diode-clamped inverter.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Multilevel converters, because of the benefits they attract in generating high quality output voltage, are used in several applications. Various modulation and control techniques are introduced by several researchers to control the output voltage of the multilevel converters like space vector modulation and harmonic elimination (HE) methods. Multilevel converters may have a DC link with equal or unequal DC voltages. In this study a new HE technique based on the HE method is proposed for multilevel converters with unequal DC link voltage. The DC link voltage levels are considered as additional variables for the HE method and the voltage levels are defined based on the HE results. Increasing the number of voltage levels can reduce lower order harmonic content because of the fact that more variables are created. In comparison to previous methods, this new technique has a positive effect on the output voltage quality by reducing its total harmonic distortion, which must take into consideration for some applications such as uninterruptable power supply, motor drive systems and piezoelectric transducer excitation. In order to verify the proposed modulation technique, MATLAB simulations and experimental tests are carried out for a single-phase four-level diode-clamped converter.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Design of a series-connected photovoltaic generator (SPVG) capable of enhancing power quality is investigated. Analysis of the SPVG operations under disturbance conditions shows explicitly how achievable network voltage quality is affected by the SPVG injected power and its apparent power rating, and that voltage quality can be significantly improved even with a modest level of energy storage capacity incorporated in the SPVG. A control system for the SPVG is also proposed. Both simulation and laboratory tests confirm the efficacy of the distributed generator system.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this paper, a novel 12-sided polygonal space vector structure is proposed for an induction motor drive. The space vector pattern presented in this paper consists of two 12-sided concentric polygons with the outer polygon having a radius double the inner one. As compared to previously reported 12-sided polygonal space vector structures, this paper subdivides the space vector plane into smaller sized triangles. This helps in reducing the switching frequency of the inverters without deteriorating the output voltage quality. It also reduces the device ratings and dv/dt stress on the devices to half. At the same time, other benefits obtained from the existing 12-sided space vector structure, such as increased linear modulation range and complete elimination of 5th and 7th order harmonics in the phase voltage, are also retained in this paper. The space vector structure is realized by feeding an open-end induction motor with two conventional three-level neutral point clamped (NPC) inverters with asymmetric isolated dc link voltage sources. The neutral point voltage fluctuations in the three-level NPC inverters are eliminated by utilizing the switching state multiplicities for a space vector point. The pulsewidth modulation timings are calculated using sampled reference waveform amplitudes and are explained in detail in this paper. Experimental verification on a laboratory prototype shows that this configuration may be considered suitable for high power drives.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a novel STATCOM configuration for voltage quality improvement in wind power generation systems. The proposed STATCOM is formed by cascading two 3-level inverters, `bulk inverter' and `conditioning inverter', through a coupling transformer. Both inverters are powered by dc-link capacitors and they are charged by a small amount of active power drawn from the grid. To minimize switching losses, the high power bulk inverter operates at low frequency while low power high frequency conditioning inverter is used to suppress harmonic content produced by the bulk inverter output. With only 24 switches this topology can synthesize a nine level inverter, if the dc-link voltage ratio is maintained at 3:1. Modulation and control techniques have been developed to meet this requirement. Reactive power of the STATCOM is controlled to mitigate voltage sags or swells caused by sudden wind changes. Simulation and experimental results are presented to verify the efficacy of the proposed modulation and control techniques used in the STATCOM.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This project was a step forward in improving the voltage profile of traditional low voltage distribution networks with high photovoltaic generation or high peak demand. As a practical and economical solution, the developed methods use a Dynamic Voltage Restorer or DVR, which is a series voltage compensator, for continuous and communication-less power quality enhancement. The placement of DVR in the network is optimised in order to minimise its power rating and cost. In addition, new approaches were developed for grid synchronisation and control of DVR which are integrated with the voltage quality improvement algorithm for stable operation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel dodecagonal space vector structure for induction motor drive is presented in this paper. It consists of two dodecagons, with the radius of the outer one twice the inner one. Compared to existing dodecagonal space vector structures, to achieve the same PWM output voltage quality, the proposed topology lowers the switching frequency of the inverters and reduces the device ratings to half. At the same time, other benefits obtained from existing dodecagonal space vector structure are retained here. This includes the extension of the linear modulation range and elimination of all 6+/-1 harmonics (n=odd) from the phase voltage. The proposed structure is realized by feeding an open-end winding induction motor with two conventional three level inverters. A detailed calculation of the PWM timings for switching the space vector points is also presented. Simulation and experimental results indicate the possible application of the proposed idea for high power drives.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes the different types of space vector based bus clamped PWM algorithms for three level inverters. A novel bus clamp PWM algorithm for low modulation indices region is also presented. The principles and switching sequences of all the types of bus clamped algorithms for high switching frequency are presented. Synchronized version of the PWM sequences for high power applications where switching frequency is low is also presented. The implementation details on DSP based digital controller and experimental results are presented. The THD of the output waveforms is studied for the entire operating region and is compared with the conventional space vector PWM technique. The bus clamped techniques can be used to reduce the switching losses or to improve the output voltage quality or both.. Different issues dominate depending on the type of application and power rating of the inverters. The results presented in this paper can be used for judicious use of the PWM techniques, which result in improved system efficiency and performance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A monitorização da qualidade da energia eléctrica tem revelado importância crescente na gestão e caracterização da rede eléctrica. Estudos revelam que os custos directos relacionados com perda de qualidade da energia eléctrica podem representar cerca de 1,5 % do PIB nacional. Para além destes, tem-se adicionalmente os custos indirectos o que se traduz num problema que necessita de minimização. No contexto da minimização dos danos causados pela degradação de energia, são utilizados equipamentos com capacidade de caracterizar a energia eléctrica através da sua monitorização. A utilização destes equipamentos têm subjacente normas de qualidade de energia, que impõem requisitos mínimos de modo a enquadrar e classificar eventos ocorridos na rede eléctrica. Deste modo obtêm-se dados coerentes provenientes de diferentes equipamentos. A monitorização dos parâmetros associados à energia eléctrica é frequentemente realizada através da instalação temporária dos esquipamentos na rede eléctrica, o que resulta numa observação de distúrbios a posteriori da sua ocasião. Esta metodologia não permite detectar o evento eléctrico original mas, quando muito, outros que se espera que sejam semelhantes ao ocorrido. Repare-se, no entanto, que existe um conjunto alargado de eventos que não são repetitivos, constituindo assim uma limitação aquela metodologia. Este trabalho descreve uma alternativa à metodologia de utilização tradicional dos equipamentos. A solução consiste em realizar um analisador de energia que faça parte integrante da instalação e permita a monitorização contínua da rede eléctrica. Este equipamento deve ter um custo suficientemente baixo para que seja justificável nesta utilização alternativa. O analisador de qualidade de energia a desenvolver tem por base o circuito integrado ADE7880, que permite obter um conjunto de parâmetros da qualidade de energia eléctrica de acordo com as normas de energia IEC 61000-4-30 e IEC 61000-4-7. Este analisador permite a recolha contínua de dados específicos da rede eléctrica, e que posteriormente serão armazenados e colocados à disposição do utilizador. Deste modo os dados recolhidos serão apresentados ao utilizador para consulta, de maneira a verificar, de modo continuo a eventual ocorrência das anomalias na rede. Os valores adquiridos podem ainda ser reutilizados vantajosamente para muitas outras finalidades tais como efectuar estudos sobre a optimização energética. O trabalho presentemente desenvolvido decorre de uma utilização alternativa do dispositivo WeSense Energy1 desenvolvido pela equipa da Evoleo Technologies. A presente vertente permite obter parâmetros determinados pelo ADE7880 tais como por exemplo harmónicos, eventos transitórios de tensão e corrente e o desfasamento entre fases, realizando assim uma nova versão do dispositivo, o WeSense Energy2. Adicionalmente este trabalho inclui a visualização remota dos através de uma página web.