851 resultados para Visual performance
Resumo:
Purpose To design and manufacture lenses to correct peripheral refraction along the horizontal meridian and to determine whether these resulted in noticeable improvements in visual performance. Method Subjective refraction of a low myope was determined on the basis of best peripheral detection acuity along the horizontal visual field out to ±30° for both horizontal and vertical gratings. Subjective refraction was compared to objective refractions using a COAS-HD aberrometer. Special lenses were made to correct peripheral refraction, based on designs optimized with and without smoothing across a 3 mm diameter square aperture. Grating detection was retested with these lenses. Contrast thresholds of 1.25’ spots were determined across the field for the conditions of best correction, on-axis correction, and the special lenses. Results The participant had high relative peripheral hyperopia, particularly in the temporal visual field (maximum 2.9 D). There were differences > 0.5D between subjective and objective refractions at a few field angles. On-axis correction reduced peripheral detection acuity and increased peripheral contrast threshold in the peripheral visual field, relative to the best correction, by up to 0.4 and 0.5 log units, respectively. The special lenses restored most of the peripheral vision, although not all at angles to ±10°, and with the lens optimized with aperture-smoothing possibly giving better vision than the lens optimized without aperture-smoothing at some angles. Conclusion It is possible to design and manufacture lenses to give near optimum peripheral visual performance to at least ±30° along one visual field meridian. The benefit of such lenses is likely to be manifest only if a subject has a considerable relative peripheral refraction, for example of the order of 2 D.
Resumo:
We studied the effect of rod–cone interactions on mesopic visual reaction time (RT). Rod and cone photoreceptor excitations were independently controlled using a four-primary photostimulator. It was observed that (1) lateral rod–cone interactions increase the cone-mediated RTs; (2) the rod–cone interactions are strongest when rod sensitivity is maximal in a dark surround, but weaker with increased rod activity in a light surround; and (3) the presence of a dark surround nonselectively increased the mean and variability of chromatic (+L-M, S-cone) and luminance (L+M+S) RTs independent of the level of rod activity. The results demonstrate that lateral rod–cone interactions must be considered when deriving mesopic luminous efficiency using RT.
Resumo:
Uncorrected refractive error, including astigmatism, is a leading cause of reversible visual impairment. While the ability to perform vision-related daily activities is reduced when people are not optimally corrected, only limited research has investigated the impact of uncorrected astigmatism. Given the capacity to perform vision-related daily activities involves integration of a range of visual and cognitive cues, this research examined the impact of simulated astigmatism on visual tasks that also involved cognitive input. The research also examined whether the higher levels of complexity inherent in Chinese characters makes them more susceptible to the effects of astigmatism. The effects of different powers of astigmatism, as well as astigmatism at different axes were investigated in order to determine the minimum level of astigmatism that resulted in a decrement in visual performance.
Resumo:
The third edition of the Australian Standard AS1742 Manual of Uniform Traffic Control Devices Part 7 provides a method of calculating the sighting distance required to safely proceed at passive level crossings based on the physics of moving vehicles. This required distance becomes greater with higher line speeds and slower, heavier vehicles so that it may return quite a long sighting distance. However, at such distances, there are also concerns around whether drivers would be able to reliably identify a train in order to make an informed decision regarding whether it would be safe to proceed across the level crossing. In order to determine whether drivers are able to make reliable judgements to proceed in these circumstances, this study assessed the distance at which a train first becomes identifiable to a driver as well as their, ability to detect the movement of the train. A site was selected in Victoria, and 36 participants with good visual acuity observed 4 trains in the 100-140 km/h range. While most participants could detect the train from a very long distance (2.2 km on average), they could only detect that the train was moving at much shorter distances (1.3 km on average). Large variability was observed between participants, with 4 participants consistently detecting trains later than other participants. Participants tended to improve in their capacity to detect the presence of the train with practice, but a similar trend was not observed for detection of the movement of the train. Participants were consistently poor at accurately judging the approach speed of trains, with large underestimations at all investigated distances.
Resumo:
The aim of this study is to evaluate lighting conditions and speleologists’ visual performance using optical filters when exposed to the lighting conditions of cave environments. A crosssectional study was conducted. Twenty-three speleologists were submitted to an evaluation of visual function in a clinical lab. An examination of visual acuity, contrast sensitivity, stereoacuity and flashlight illuminance levels was also performed in 16 of the 23 speleologists at two caves deprived of natural lightning. Two organic filters (450 nm and 550 nm) were used to compare visual function with and without filters. The mean age of the speleologists was 40.65 (± 10.93) years. We detected 26.1% participants with visual impairment of which refractive error (17.4%) was the major cause. In the cave environment the majority of the speleologists used a head flashlight with a mean illuminance of 451.0 ± 305.7 lux. Binocular visual acuity (BVA) was -0.05 ± 0.15 LogMAR (20/18). BVA for distance without filter was not statistically different from BVA with 550 nm or 450 nm filters (p = 0.093). Significant improved contrast sensitivity was observed with 450 nm filters for 6 cpd (p = 0.034) and 18 cpd (p = 0.026) spatial frequencies. There were no signs and symptoms of visual pathologies related to cave exposure. Illuminance levels were adequate to the majority of the activities performed. The enhancement in contrast sensitivity with filters could potentially improve tasks related with the activities performed in the cave.
Resumo:
Thermochromic windows are able to modulate their transmittance in both the visible and the near-infrared field as a function of their temperature. As a consequence, they allow to control the solar gains in summer, thus reducing the energy needs for space cooling. However, they may also yield a reduction in the daylight availability, which results in the energy consumption for indoor artificial lighting being increased. This paper investigates, by means of dynamic simulations, the application of thermochromic windows to an existing office building in terms of energy savings on an annual basis, while also focusing on the effects in terms of daylighting and thermal comfort. In particular, due attention is paid to daylight availability, described through illuminance maps and by the calculation of the daylight factor, which in several countries is subject thresholds. The study considers both a commercially available thermochromic pane and a series of theoretical thermochromic glazing. The expected performance is compared to static clear and reflective insulating glass units. The simulations are repeated in different climatic conditions, showing that the overall energy savings compared to clear glazing can range from around 5% for cold climates to around 20% in warm climates, while not compromising daylight availability. Moreover the role played by the transition temperature of the pane is examined, pointing out an optimal transition temperatures that is irrespective of the climatic conditions.
Resumo:
Background: Long-term evolution of congenital toxoplasmosis is not documented. We assessed the outcome of treated congenital toxoplasmosis in a cohort of adult individuals who had undergone ante- and postnatal treatment to provide information for pediatricians and parents on the evolution of the disease. Methods: We conducted a questionnaire study on 126 adults with congenital toxoplasmosis (mean age: 22.2 years; age range: 18–31 years) monitored regularly until the time of inclusion. The main outcome measures were quality of life (Psychological General Well-Being Index) and visual function (VF14 questionnaire), and the outcomes were correlated with disease-specific factors. Results: Of the 102 patients (80.9%) who were finally included in the study, 12 (11.8%) presented neurologic effects and 60 (58.8%) manifested ocular lesions; in the latter category, 13 individuals (12.7%) had reduced visual function. The overall global quality-of-life score (74.7 ± 14.2) was close to the expected normal range for the general population (73.7 ± 15.3). Overall, visual function was only slightly impaired (M = 97.3; 95% confidence interval, 95.8–98.8). Although disease-independent critical life circumstances were associated with a reduced Psychological General Well-Being Index, this index was not influenced by any of the clinical characteristics of congenital toxoplasmosis. Neurologic pathologies, reduced visual acuity, foveal location of the retinal lesion, and squinting contributed to decreased visual function at follow-up. Conclusions: Our data reveal that treated congenital toxoplasmosis has little effect on the quality of life and visual function of the affected individuals. These encouraging findings may help to alleviate the anxiety of affected individuals and their parents.
Resumo:
Over recent years, it has repeatedly been shown that optimal gaze strategies enhance motor control (e.g., Foulsham, 2015). However, little is known, whether, vice versa, visual performance can be improved by optimized motor control. Consequently, in two studies, we investigated visual performance as a function of motor control strategies and task parameters, respectively. In Experiment 1, 72 participants were tested on visual acuity (Landolt) and contrast sensitivity (Grating), while standing in two different postures (upright vs. squat) on a ZEPTOR-platform that vibrated at four different frequencies (0, 4, 8, 12 Hz). After each test, perceived exertion (Borg) was assessed. Significant interactions were revealed for both tests, Landolt: F(3,213)=13.25, p<.01, ηp2=.16, Grating: F(3,213)=4.27, p<.01, ηp2=.06, elucidating a larger loss of acuity/contrast sensitivity with increasing frequencies for the upright compared with the squat posture. For perceived exertion, however, a diametrical interaction for frequency was found for acuity, F(3,213)=7.45, p<.01, ηp2=.09, and contrast sensitivity, F(3,213)=7.08, p < .01, ηp2=.09, substantiating that the impaired visual performance cannot be attributed to exertion. Consequently, the squat posture could permit better head and, hence, gaze stabilization. In Experiment 2, 64 participants performed the same tests while standing in a squat position on a ski-simulator, which vibrated with two different frequencies (2.4, 3.6 Hz) and amplitudes (50, 100 mm) in a predictable or unpredictable manner. Control strategies were identified by tracking segmental motion, which allows to derive damping characteristics. Considerable main effects were found for frequency, all F’s(1,52)>10.31, all p’s<.01, all ηp2’s>.16, as well as, in the acuity test, for predictability, F(1,52)=10.31, p<.01, ηp2=.17, and by tendency for amplitude, F(1,52)=3.53, p=.06, ηp2=.06. A significant correlation between the damping amplitude in the knee joint and the performance drop in visual acuity, r=-.97, p<.001, again points towards the importance of motor control strategies to maintain optimal visual performance.
Resumo:
PURPOSE: To evaluate and compare the visual, refractive, contrast sensitivity, and aberrometric outcomes with a diffractive bifocal and trifocal intraocular lens (IOL) of the same material and haptic design. METHODS: Sixty eyes of 30 patients undergoing bilateral cataract surgery were enrolled and randomly assigned to one of two groups: the bifocal group, including 30 eyes implanted with the bifocal diffractive IOL AT LISA 801 (Carl Zeiss Meditec, Jena, Germany), and the trifocal group, including eyes implanted with the trifocal diffractive IOL AT LISA tri 839 MP (Carl Zeiss Meditec). Analysis of visual and refractive outcomes, contrast sensitivity, ocular aberrations (OPD-Scan III; Nidek, Inc., Gagamori, Japan), and defocus curve were performed during a 3-month follow-up period. RESULTS: No statistically significant differences between groups were found in 3-month postoperative uncorrected and corrected distance visual acuity (P > .21). However, uncorrected, corrected, and distance-corrected near and intermediate visual acuities were significantly better in the trifocal group (P < .01). No significant differences between groups were found in postoperative spherical equivalent (P = .22). In the binocular defocus curve, the visual acuity was significantly better for defocus of -0.50 to -1.50 diopters in the trifocal group (P < .04) and -3.50 to -4.00 diopters in the bifocal group (P < .03). No statistically significant differences were found between groups in most of the postoperative corneal, internal, and ocular aberrations (P > .31), and in contrast sensitivity for most frequencies analyzed (P > .15). CONCLUSIONS: Trifocal diffractive IOLs provide significantly better intermediate vision over bifocal IOLs, with equivalent postoperative levels of visual and ocular optical quality.
Resumo:
Background: The aim was to evaluate the visual performance achieved with a new multifocal hybrid contact lens and to compare it with that obtained with two other currently available multifocal soft contact lenses. Methods: This pilot prospective comparative study comprised a total of 16 presbyopic eyes of eight patients ranging in age from 43 to 58 years. All patients were fitted with three different models of multifocal contact lens: Duette multifocal (SynergEyes), Air Optix AQUA multifocal (Alcon) and Biofinity multifocal (CooperVision). Fittings were performed randomly in each patient according to a random number sequence, with a wash-out period between fittings of seven days. At two weeks post-fitting, visual, photopic contrast sensitivity and ocular aberrometry were evaluated. Results: No statistically significant differences were found in distance and near visual acuity achieved with the three different types of multifocal contact lens (p ≥ 0.05). Likewise, no significant differences between lenses were found in the monocular and binocular defocus curve (p ≥ 0.10). Concerning contrast sensitivity, better monocular contrast sensitivities for 6, 12 and 18 cycles per degree were found with the Duette and Air Optix multifocal compared to Biofinity (p = 0.02). Binocularly, differences between lenses were not significant (p ≥ 0.27). Furthermore, trefoil aberration was significantly higher with Biofinity multifocal (p < 0.01) and Air Optix (p = 0.01) multifocal compared to Duette. Conclusions: The Duette multifocal hybrid contact lens seems to provide similar visual quality outcomes in presbyopic patients with low corneal astigmatism, when compared with other soft multifocal contact lenses. This preliminary result should be confirmed in studies with larger samples.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
"352A."