56 resultados para Viscometer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the frequent use of stepping motors in robotics, automation, and a variety of precision instruments, they can hardly be found in rotational viscometers. This paper proposes the use of a stepping motor to drive a conventional constant-shear-rate laboratory rotational viscometer to avoid the use of velocity sensor and gearbox and, thus, simplify the instrument design. To investigate this driving technique, a commercial rotating viscometer has been adapted to be driven by a bipolar stepping motor, which is controlled via a personal computer. Special circuitry has been added to microstep the stepping motor at selectable step sizes and to condition the torque signal. Tests have been carried out using the prototype to produce flow curves for two standard Newtonian fluids (920 and 12 560 mPa (.) s, both at 25 degrees C). The flow curves have been obtained by employing several distinct microstep sizes within the shear rate range of 50-500 s(-1). The results indicate the feasibility of the proposed driving technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the frequent use of stepping motors in robotics, automation, and a variety of precision instruments, they can hardly be found in rotational viscometers. This paper proposes the use of a stepping motor to drive a conventional constant-shear-rate laboratory rotational viscometer to avoid the use of velocity sensor and gearbox and, thus, simplify the instrument design. To investigate this driving technique, a commercial rotating viscometer has been adapted to be driven by a bipolar stepping motor, which is controlled via a personal computer. Special circuitry has been added to microstep the stepping motor at selectable step sizes and to condition the torque signal. Tests have been carried out using the prototype to produce flow curves for two standard Newtonian fluids (920 and 12 560 mPa (.) s, both at 25 degrees C). The flow curves have been obtained by employing several distinct microstep sizes within the shear rate range of 50-500 s(-1). The results indicate the feasibility of the proposed driving technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a technique to measure the viscosity of microscopic volumes of liquid using rotating optical tweezers. The technique can be used when only microlitre (or less) sample volumes are available, for example biological or medical samples, or to make local measurements in complicated micro-structures such as cells. The rotation of the optical tweezers is achieved using the polarisation of the trapping light to rotate a trapped birefringent spherical crystal, called vaterite. Transfer of angular momentum from a circularly polarised beam to the particle causes the rotation. The transmitted light can then be analysed to determine the applied torque to the particle and its rotation rate. The applied torque is determined from the change in the circular polarisation of the beam caused by the vaterite and the rotation rate is used to find the viscous drag on the rotating spherical particle. The viscosity of the surrounding liquid can then be determined. Using this technique we measured the viscosity of liquids at room temperature, which agree well with tabulated values. We also study the local heating effects due to absorption of the trapping laser beam. We report heating of 50-70 K/W in the region of liquid surrounding the particle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Real-time viscosity measurement remains a necessity for highly automated industry. To resolve this problem, many studies have been carried out using an ultrasonic shear wave reflectance method. This method is based on the determination of the complex reflection coefficient`s magnitude and phase at the solid-liquid interface. Although magnitude is a stable quantity and its measurement is relatively simple and precise, phase measurement is a difficult task because of strong temperature dependence. A simplified method that uses only the magnitude of the reflection coefficient and that is valid under the Newtonian regimen has been proposed by some authors, but the obtained viscosity values do not match conventional viscometry measurements. In this work, a mode conversion measurement cell was used to measure glycerin viscosity as a function of temperature (15 to 25 degrees C) and corn syrup-water mixtures as a function of concentration (70 to 100 wt% of corn syrup). Tests were carried out at 1 MHz. A novel signal processing technique that calculates the reflection coefficient magnitude in a frequency band, instead of a single frequency, was studied. The effects of the bandwidth on magnitude and viscosity were analyzed and the results were compared with the values predicted by the Newtonian liquid model. The frequency band technique improved the magnitude results. The obtained viscosity values came close to those measured by the rotational viscometer with percentage errors up to 14%, whereas errors up to 96% were found for the single frequency method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents the implementation of the ultrasonic shear reflectance method for viscosity measurement of Newtonian liquids using wave mode conversion from longitudinal to shear waves and vice versa. The method is based on the measurement of the complex reflection coefficient (magnitude and phase) at a solid-liquid interface. The implemented measurement cell is composed of an ultrasonic transducer, a water buffer, an aluminum prism, a PMMA buffer rod, and a sample chamber. Viscosity measurements were made in the range from 1 to 3.5 MHz for olive oil and for automotive oils (SAE 40, 90, and 250) at 15 and 22.5 degrees C, respectively. Moreover, olive oil and corn oil measurements were conducted in the range from 15 to 30 degrees C at 3.5 and 2.25 MHz, respectively. The ultrasonic measurements, in the case of the less viscous liquids, agree with the results provided by a rotational viscometer, showing Newtonian behavior. In the case of the more viscous liquids, a significant difference was obtained, showing a clear non-Newtonian behavior that cannot be described by the Kelvin-Voigt model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The intra-buccal polymeric bioadhesive systems that can stay adhered to the oral soft tissues for drug programmed release, with the preventive and/or therapeutic purpose has been employed for large clinical situations. A system based on hydroxypropyl methyl cellulose/Carbopol 934`/magnesium stearate (HPMC/Cp/StMg) was developed having the sodium fluoride as active principle. This kind of system was evaluated according to its resistance to the removal by means of physical test of tensile strength. Swine buccal mucosa extracted immediately after animals` sacrifice was employed as substrate for the physical trials, to obtain 16 test bodies. Artificial saliva with or without mucin was used to involve the substrate/bioadhesive system sets during the trials. Artificial salivas viscosity was determined by means of Brookfield viscometer, showing the artificial saliva with mucin 10.0 cP, and the artificial saliva without mucin 7.5 cP. The tensile strength assays showed the following averages: for the group ""artificial saliva with mucin"" - 12.89 Pa, and for the group ""without mucin"" - 12.35 Pa. Statistical analysis showed no significant difference between the assays for both artificial salivas, and it was possible to conclude that the variable mucin did not interfered with the bioadhesion process for the polymeric devices. The device was able to release fluoride in a safe, efficient and constant way up to 8 hours.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The resin phase of dental composites is mainly composed of combinations of dimethacrylate comonomers, with final polymeric network structure defined by monomer type/reactivity and degree of conversion. This fundamental study evaluates how increasing concentrations of the flexible triethylene glycol dimethacrylate (TEGDMA) influences void formation in bisphenol A diglycidyl dimethacrylate (BisGMA) co-polymerizations and correlates this aspect of network structure with reaction kinetic parameters and macroscopic volumetric shrinkage. Photopolymerization kinetics was followed in real-time by a near-infrared (NIR) spectroscopic technique, viscosity was assessed with a viscometer, volumetric shrinkage was followed with a linometer, free volume formation was determined by positron annihilation lifetime spectroscopy (PALS) and the sol-gel composition was determined by extraction with dichloromethane followed by (1)H NMR analysis. Results show that, as expected, volumetric shrinkage increases with TEGDMA concentration and monomer conversion. Extraction/(1)H NMR studies show increasing participation of the more flexible TEGDMA towards the limiting stages of conversion/crosslinking development. As the conversion progresses, either based on longer irradiation times or greater TEGDMA concentrations, the network becomes more dense, which is evidenced by the decrease in free volume and weight loss after extraction in these situations. For the same composition (BisGMA/TEGDMA 60-40 mol%) light-cured for increasing periods of time (from 10 to 600 s), free volume decreased and volumetric shrinkage increased, in a linear relationship with conversion. However, the correlation between free volume and macroscopic volumetric shrinkage was shown to be rather complex for variable compositions exposed for the same time (600 s). The addition of TEGDMA decreases free-volume up to 40 mol% (due to increased conversion), but above that concentration, in spite of the increase in conversion/crosslinking, free volume pore size increases due to the high concentration of the more flexible monomer. In those cases, the increase in volumetric shrinkage was due to higher functional group concentration, in spite of the greater free volume. Therefore, through the application of the PALS model, this study elucidates the network formation in dimethacrylates commonly used in dental materials. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. Stress development at the tooth/restoration interface is one of the most important reasons for failure of adhesive restorations. The aim of this study was to evaluate the influence of BisGMA/TEGDMA (B/T) and UDMA/TEGDMA (U/T) ratios on polymerization stress (PS) and on the variables related to its development: degree of conversion (DC), polymerization maximum rate (Rp(max)), volumetric shrinkage (VS), elastic modulus (E), stress relaxation (SR) and viscosity of experimental composites. Method. Composites were formulated containing B/T or U/T in mol% ratios of 2: 8, 3: 7, 4: 6, 5: 5, 6: 4, 7: 3 and 8: 2, and 15 wt% of fumed silica. PS was determined with a universal testing machine. VS was measured with a linometer. E and SR were obtained in three-point bending. DC and Rp(max) were determined by real time NIR spectroscopy and viscosity was measured in viscometer. Data were submitted to one-way ANOVA, Tukey test (alpha = 0.05%) and regression analyses. Results. PS, VS, E and DC decreased and viscosity and Rp(max) increased with base monomer content in both series. PS showed strong correlation with VS, DC and viscosity. PS, VS and DC were higher and viscosity was lower for UDMA-based materials. Significance. Reduced viscosity, kinetics parameters and molecular characteristics led UDMA-based composites to elevated conversion and relatively lower PS at lower TEGDMA contents, compared to B/T composites. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Different monomer structures lead to different physical and mechanical properties for both the monomers and the polymers. The objective of this study was to determine the influence of the bisphenylglycidyl dimethacrylate (BisGMA) concentration (33, 50 or 66 mol%) and the co-monomer content [triethylene glycol dimethacrylate (TEGDMA), ethoxylated bisphenol-A dimethacrylate (BisEMA), or both in equal parts] on viscosity (eta), degree of conversion (DC), and flexural strength (FS). eta was measured using a viscometer, DC was obtained by Fourier transfer Raman (FT-Raman) spectroscopy, and FS was determined by three-point bending. At 50 and 66% BisGMA, increases in eta were observed following the partial and total substitution of TEGDMA by BisEMA. For 33% BisGMA, eta increased significantly only when no TEGDMA was present. The DC was influenced by BisGMA content and co-monomer type. Mixtures containing 66% BisGMA showed a lower DC compared with mixtures containing other concentrations of BisGMA. The BisEMA mixtures had a lower DC compared with the TEGDMA mixtures. The FS was influenced by co-monomer content only. BisEMA mixtures presented a statistically lower FS, followed by TEGDMA + BisEMA mixtures, and then by TEGDMA mixtures. Partial or total replacement of TEGDMA by BisEMA increased eta, which was associated with the observed decreases in DC and FS. Although the BisGMA content influenced the DC, it did not affect the FS results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ten surveys of the ball milling circuit at the Mt Isa Mines (MIM) Copper Concentrator were conducted aiming to identify any changes in slurry theology caused by the use of chrome balls charge, and the associated effect on grinding performance. Slurry theology was measured using an on-line viscometer. The data were mass balanced and analysed with statistical tools. Comparison of the rheogram demonstrated that slurry density and fines content affected slurry rheology significantly, while the effect of the chrome ball charge being negligible. Statistical analysis showed the effects of mill throughput and cyclone efficiency on the Grinding Index (a term describing the overall breakage). There was no difference in the Grinding Index between using the chrome ball charge and the ordinary steel ball charge. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A literature review has highlighted the need to measure flotation froth rheology in order to fully characterise the role of the froth in the flotation process. The initial investigation using a coaxial cylinder viscometer for froth rheology measurement led to the development of a new device employing a vane measuring head. The modified rheometer was used in industrial scale flotation tests at Mt. Isa Copper Concentrator. The measured froth rheograms show a non-Newtonian nature for the flotation froths (pseudoplastic flow). The evidence of the non-Newtonian flow has questioned the validity of application of the Laplace equation in froth motion modelling as used by a number of researchers, since the assumption of irrotational flow is violated. Correlations between the froth rheology and the froth retention time, water hold-up in the froth and concentrate grades have been found. These correlations are independent of air flow rate (test data at various air flow rates fall on one similar trend line). This implies that froth rheology may be used as a lumped parameter for other operating variables in flotation modelling and scale up. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As estradas têm vindo a sofrer um aumento de importância, sendo necessário aplicar pavimentos com melhores características, assim foram desenvolvidos os mastiques betuminosos. Os mastiques são misturas de betume com filer, este material tem propriedades melhoradas em relação ao betume puro. O betume é um material viscoelástico, o que leva a que a viscosidade seja uma propriedade de vital importância estudar. A junção de fileres ao betume promove um aumento de viscosidade, levando a que esta propriedade reológica tenha ainda mais importância, principalmente porque a trabalhabilidade da mistura betuminosa fica comprometida quando a viscosidade não é a correta. Na realização desta dissertação foram realizados ensaios em mastiques betuminosos, com recurso ao viscosímetro rotativo de Brookfield. Os mastiques ensaiados são compostos com fileres de diferentes origens e com diferentes taxas de incorporação, e assim foram analisadas as diferenças obtidas nos valores da viscosidade dinâmica. Os resultados obtidos mostram que os mastiques, à temperatura de fabrico, têm um comportamento viscoso idêntico ao comportamento viscoso do betume puro. Apesar dos mastiques produzidos terem uma viscosidade maior que a do betume puro, o valor desta propriedade reológica tende a igualar ao valor do betume, este comportamento observa-se nas temperaturas mais elevadas. Quando se examinam os resultados dos mastiques produzidos com menor quantidade de filer, na generalidade, os valores da viscosidade obtidos são idênticos. Para taxas de incorporação maiores, os valores da viscosidade dinâmica dos mastiques produzidos são bastante mais altos e distintos. Levando a concluir que quanto maior a percentagem de filer no mastique, maior o valor da viscosidade e maior dispersão dos resultados obtidos, isto para os fileres e taxas de incorporação testadas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Civil

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Effects of polyolefins, neoprene, styrene-butadiene-styrene (SBS) block copolymers, styrene-butadiene rubber (SBR) latex, and hydrated lime on two asphalt cements were evaluated. Physical and chemical tests were performed on a total of 16 binder blends. Asphalt concrete mixes were prepared and tested with these modified binders and two aggregates (crushed limestone and gravel), each at three asphalt content levels. Properties evaluated on the modified binders (original and thin-film oven aged) included: viscosity at 25 deg C, 60 deg C and 135 deg C with capillary tube and cone-plate viscometer, penetration at 5 deg C and 25 deg C, softening point, force ductility, and elastic recovery at 10 deg C, dropping ball test, tensile strength, and toughness and tenacity tests at 25 deg C. From these the penetration index, the viscosity-temperature susceptibility, the penetration-viscosity number, the critical low-temperature, long loading-time stiffness, and the cracking temperature were calculated. In addition, the binders were studied with x-ray diffraction, reflected fluorescence microscopy, and high-performance liquid chromatography techniques. Engineering properties evaluated on the 72 asphalt concrete mixes containing additives included: Marshall stability and flow, Marshall stiffness, voids properties, resilient modulus, indirect tensile strength, permanent deformation (creep), and effects of moisture by vacuum-saturation and Lottman treatments. Pavement sections of varied asphalt concrete thicknesses and containing different additives were compared to control mixes in terms of structural responses and pavement lives for different subgrades. Although all of the additives tested improved at least one aspect of the binder/mixture properties, no additive was found to improve all the relevant binder/mixture properties at the same time. On the basis of overall considerations, the optimum beneficial effects can be expected when the additives are used in conjunction with softer grade asphalts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tämän diplomityön tarkoituksena oli tutkia pintaliimatärkkelysten reologista käyttäytymistä korkeissa kuiva-ainepitoisuuksissa. Tarve työn suorittamiselle syntyi kun tutkittiin pintaliimausta filminsiirtopuristimella tavallista korkeammissa kuiva-ainepitoisuuksissa, sileän sauvan ollessa applikointilaitteena. Koska applikointi sileällä sauvalla tapahtuu hydrodynaamisten periaatteiden mukaisesti, sen käyttö edellyttää pintaliimojen reologisten ominaisuuksien tarkkaa tuntemusta ja hallintaa.Kiinnostuksen kohteena olevat ominaisuudet olivat tärkkelysten kuiva-ainepitoisuuden (8 – 30 %) vaikutus viskositeettiin eri lämpötiloissa (20, 30, 40 ja 50 ºC), leikkausnopeus alueella 1 s-1 - 700 000 s-1. Myös tärkkelysten myötörajat määritettiin tutkimuksessa. Viskositeetti eri leikkausnopeusalueilla mitattiin seuraavilla laitteilla: Bohlin VOR (matalat leikkausnopeudet ja myötöraja) ja Hercules HiShear (keskitason leikkausnopeudet) reometrit sekä Eklund kapillaariviskometri (korkeat leikkausno-peudet). Analysoidut tärkkelykset olivat kaksi anionista matalaviskoottista peruna (tärkkelys A) ja ohra (tärkkelys C) tärkkelystä, sekä yksi kationinen korkeaviskoottinen peruna tärkkelys (tärkkelys B). Tutkittujen tärkkelysten Brookfield viskositeetit (100 rpm) olivat (10 % liuos, 60 °C:ssa) tärkkelys A ja C: 25 ± 5 mPas ja tärkkelys B: 100 ± 20 mPas.Tärkkelysliuosten kuiva-ainepitoisuuden noustessa muuttui virtauskäyttäytyminen Newtoniaalisesta leikkausohenevaksi. Leikkausoheneva käyttäytyminen oli voimakkainta tärkkelys B:n kohdalla. Viskositeetti – lämpötila riippuvuus korkeissa leikkausnopeuksissa (esim. 500 000 s-1) oli vähäisempää, mitä oli oletettavissa Brookfield viskositeettiarvojen perusteella. Kaikki tarkkelykset osoittautuivat tiksotrooppisiksi, myös tiksotrooppisuus lisääntyi kuiva-ainepitoisuuden kasvaessa. Tärkkelysten myötörajat osoittautuivat odottamattoman alhaisiksi, kuitenkin varsinkin tärkkelys B:n myötörajat olivat selvästi riippuvaisia lämpötilasta ja kuiva-ainepitoisuudesta. Tutkittujen tärkkelysten virtauskäyttäytyminen oli kirjallisuudessa esitetyn kaltaista. Tärkkelysmolekyylien ketjun pituus oli tärkein tärkkelyksen reologisia ominaisuuksia määrittävä tekijä; mitä matalampi on tärkkelyksen molekyylimassa, sitä matalammat ovat viskositeetti ja myötöraja. Pintaliimauksessa tärkkelysmolekyylien ketjunpituudella on suuri vaikutus ajettavuuteen ja lopputuotteen ominaisuuksiin. Haasteellista pintaliimatärkkelyksen valinnassa on sellaisen yhdistelmän löytäminen, jossa sopivan reologisen käyttäytymisen omaava tärkkelys ja pintaliimatulle paperille tai kartongille asetetut vaatimukset kohtaavat.