997 resultados para Virtual Experiment
Resumo:
Conferência: 2nd Experiment at International Conference (Exp at)- Univ Coimbra, Coimbra, Portugal - Sep 18-20, 2013
Resumo:
This paper presents an investigation into some practical issues that may be present in a real experiment, when trying to validate the theoretical frequency response curve of a two degree-of-freedom nonlinear system consisting of coupled linear and nonlinear oscillators. Some specific features, such as detached resonance curves, have been theoretically predicted in multi degree-of-freedom nonlinear oscillators, when subject to harmonic excitation, and the system parameters have been shown to be fundamental in achieving such features. When based on a simplified model, approximate analytical expression for the frequency response curves may be derived, which may be validated by the numerical solutions. In a real experiment, however, the practical achievability of such features was previously shown to be greatly affected by small disturbances induced by gravity and inertia, which led to some solutions becoming unstable which had been predicted to be stable. In this work a practical system configuration is proposed where such effects are reduced so that the previous limitations are overcome. A virtual experiment is carried out where a detailed multi-body model of the oscillator is assembled and the effects on the system response are investigated.
Resumo:
One of the most common problems of rotating machinery is the rotor unbalance. The effects of rotor unbalance can vary from the malfunction of certain equipment to diseases related to the exposure to high vibration levels. However, the balancing procedure is known, it is mandatory to have qualified technicians to perform it. In this sense, the use of virtual balancing experiments is of great interest. The present demo is dedicated to present two different balancing simulators, which can be explored in conjunction, as they have complementary outputs. © 2014 IEEE.
Resumo:
Virtual Experiment of the Diode Lab for ECS students
Resumo:
Liquid crystals (LCs) are an interesting class of soft condensed matter systems characterized by an unusual combination of fluidity and long-range order, mainly known for their applications in displays (LCDs). However, the interest in LC continues to grow pushed by their application in new technologies in medicine, optical imaging, micro and nano technologies etc. In LCDs uniaxial alignment of LCs is mainly achieved by a rubbing process. During this treatment, the surfaces of polymer coated display substrates are rubbed in one direction by a rotating cylinder covered with a rubbing cloth. Basically, LC alignment involves two possible aligning directions: uniaxial planar (homogeneous) and vertical (homeotropic) to the display substrate. An interesting unresolved question concerning LCs regards the origin of their alignment on rubbed surfaces, and in particular on the polymeric ones used in the display industry. Most studies have shown that LCs on the surface of the rubbed polymer film layer are lying parallel to the rubbing direction. In these systems, micrometric grooves are generated on the film surface along the rubbing direction and also the polymer chains are stretched in this direction. Both the parallel aligned microgrooves and the polymer chains at the film surface may play a role in the LC alignment and it is not easy to quantify the effect of each contribution. The work described in this thesis is an attempt to find new microscopic evidences on the origin of LC alignment on polymeric surfaces through molecular dynamics (MD) simulations, which allow the investigation of the phenomenon with atomic detail. The importance of the arrangement of the polymeric chains in LCs alignment was studied by performing MD simulations of a thin film of a typical nematic LC, 4-cyano-4’-pentylbiphenyl (5CB), in contact with two different polymers: poly(methyl methacrylate)(PMMA) and polystyrene (PS). At least four factors are believed to influence the LC alignment: 1. the interactions of LCs with the backbone vinyl chains; 2. the interactions of LCs with the oriented side groups; 3. the anisotropic interactions of LCs with nanometric grooves; 4. the presence of static surface charges. Here we exclude the effect of microgrooves and of static surface charges from our virtual experiment, by using flat and neutral polymer surfaces, with the aim of isolating the chemical driving factors influencing the alignment of LC phases on polymeric surfaces.
Resumo:
Los métodos de máxima verosimilitud (MMV) ofrecen un marco alternativo a la estadística frecuentista convencional, alejándose del uso del p-valor para el rechazo de una única hipótesis nula y optando por el uso de las verosimilitudes para evaluar el grado de apoyo en los datos a un conjunto de hipótesis alternativas (o modelos) de interés para el investigador. Estos métodos han sido ampliamente aplicados en ecología en el marco de los modelos de vecindad. Dichos modelos usan una aproximación espacialmente explícita para describir procesos demográficos de plantas o procesos ecosistémicos en función de los atributos de los individuos vecinos. Se trata por tanto de modelos fenomenológicos cuya principal utilidad radica en funcionar como herramientas de síntesis de los múltiples mecanismos por los que las especies pueden interactuar e influenciar su entorno, proporcionando una medida del efecto per cápita de individuos de distintas características (ej. tamaño, especie, rasgos fisiológicos) sobre los procesos de interés. La gran ventaja de aplicar los MMV en el marco de los modelos de vecindad es que permite ajustar y comparar múltiples modelos que usen distintos atributos de los vecinos y/o formas funcionales para seleccionar aquel con mayor soporte empírico. De esta manera, cada modelo funcionará como un “experimento virtual” para responder preguntas relacionadas con la magnitud y extensión espacial de los efectos de distintas especies coexistentes, y extraer conclusiones sobre posibles implicaciones para el funcionamiento de comunidades y ecosistemas. Este trabajo sintetiza las técnicas de implementación de los MMV y los modelos de vecindad en ecología terrestre, resumiendo su uso hasta la fecha y destacando nuevas líneas de aplicación.
Resumo:
Male volunteers entered an immersive virtual reality that depicted a party, where they were approached by a lone virtual woman who initiated a conversation. The goal was to study how socially anxious and socially confident men would react to this event. Interest focused on whether the socially anxious participants would exhibit sustained anxiety during the conversation or whether this would diminish over time, and differ from the responses of the more socially confident men.
Resumo:
The relative contributions of five variables (Stereoscopy, screen size, field of view, level of realism and level of detail) of virtual reality systems on spatial comprehension and presence are evaluated here. Using a variable-centered approach instead of an object-centric view as its theoretical basis, the contributions of these five variables and their two-way interactions are estimated through a 25-1 fractional factorial experiment (screening design) of resolution V with 84 subjects. The experiment design, procedure, measures used, creation of scales and indices, results of statistical analysis, their meaning and agenda for future research are elaborated.
Resumo:
High throughput discovery of ligand scaffolds for target proteins can accelerate development of leads and drug candidates enormously. Here we describe an innovative workflow for the discovery of high affinity ligands for the benzodiazepine-binding site on the so far not crystallized mammalian GABAA receptors. The procedure includes chemical biology techniques that may be generally applied to other proteins. Prerequisites are a ligand that can be chemically modified with cysteine-reactive groups, knowledge of amino acid residues contributing to the drug-binding pocket, and crystal structures either of proteins homologous to the target protein or, better, of the target itself. Part of the protocol is virtual screening that without additional rounds of optimization in many cases results only in low affinity ligands, even when a target protein has been crystallized. Here we show how the integration of functional data into structure-based screening dramatically improves the performance of the virtual screening. Thus, lead compounds with 14 different scaffolds were identified on the basis of an updated structural model of the diazepam-bound state of the GABAA receptor. Some of these compounds show considerable preference for the α3β2γ2 GABAA receptor subtype.
Resumo:
The Global Experiment, Water: A Chemical Solution, was one of the flagship activities of the International Year of Chemistry (IYC). During the virtual colloquium of the spring 2012 online ConfChem conference, the main results of this year-long experiment were presented and discussed online for a week. Some of the main conclusions of the virtual conversations relate to the benefits of creating online communities of people sharing similar interests, the use of online educational platforms to gather massive amounts of data, and specific questions about the development of this IYC initiative. The activities of the global water experiment (GWE) were designed by a team of experts and the protocols are available online on the GWE Web site. The results were shown in one interactive world map that allowed students to learn about data visualization, validation, and interpretation. The feedback obtained from the participants of the GWE and later by the contributors of the virtual colloquium was very positive. Many participants asked specific and technical questions about the development of this experiment, while others excitedly endorsed the convenience of these large open-access activities to promote chemistry worldwide. The estimate is that over 2 million people took part in the GWE during the IYC. This communication summarizes one of the invited papers to the ConfChem online conference: A Virtual Colloquium to Sustain and Celebrate IYC 2011 Initiatives in Global Chemical Education, held from May 18 to June 29, 2012 and hosted by the ACS DivCHED Committee on Computers in Chemical Education and the IUPAC Committee on Chemistry Education.
Resumo:
We conducted two psychophysical experiments to investigate the relationship between processing mechanisms for exocentric distance and direction. In the first experiment, the task was to discriminate exocentric distances. In the second one, the task was to discriminate exocentric directions. The individual effects of distance and direction on each task were dissociated by analyzing their corresponding psychophysical functions. Under stereoscopicviewing conditions, distancejudgments of excentric intervals were not affected by exocentric direction. However, directionjudgments were influenced by the distance between the pair of stimuli. Therefore, the mechanism processing exocentric direction is dependent on exocentric distance, but the mechanism processing exocentric distance does not require exocentric: direction measures. As a result, we suggest that exocentric distance and direction are hierarchically processed, with distance preceding direction. Alternatively, and more probably, a necessary condition for processing the exocentric direction between two stimuli may be to know the location of each of them.
Resumo:
Objectives To evaluate the presence of false flow three-dimensional (3D) power Doppler signals in `flow-free` models. Methods 3D power Doppler datasets were acquired from three different flow-free phantoms (muscle, air and water) with two different transducers and Virtual Organ Computer-aided AnaLysis was used to generate a sphere that was serially applied through the 3D dataset. The vascularization flow index was used to compare artifactual signals at different depths (from 0 to 6 cm) within the different phantoms and at different gain and pulse repetition frequency (PR F) settings. Results Artifactual Doppler signals were seen in all phantoms despite these being flow-free. The pattern was very similar and the degree of artifact appeared to be dependent on the gain and distance from the transducer. False signals were more evident in the far field and increased as the gain was increased, with false signals first appearing with a gain of 1 dB in the air and muscle phantoms. False signals were seen at a lower gain with the water phantom (-15 dB) and these were associated with vertical lines of Doppler artifact that were related to PRF, and disappeared when reflections were attenuated. Conclusions Artifactual Doppler signals are seen in flow-free phantoms and are related to the gain settings and the distance from the transducer. In the in-vivo situation, the lowest gain settings that allow the detection of blood flow and adequate definition of vessel architecture should be used, which invariably means using a setting near or below the middle of the range available. Additionally, observers should be aware of vertical lines when evaluating cystic or liquid-containing structures. Copyright (C) 2010 ISUOC. Published by John Wiley & Sons, Ltd.