997 resultados para Venous pressure


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of thermodilution and other methods of monitoring in dogs during surgery and critical care was evaluated. Six Greyhounds were anaesthetised and then instrumented by placing a thermodilution catheter into the pulmonary artery via the jugular vein. A catheter in the dorsal pedal artery also permitted direct measurement of arterial pressures. Core body temperature (degreesC) and central venous pressure (mmHg) were measured, while cardiac output (mL/min/kg) and mean arterial pressure (mmHg) were calculated. A mid-line surgical incision was performed and the physiological parameters were monitored for a total of two hours. All physiological parameters generally declined, although significant increases (P<0.05) were noted for cardiac output following surgical incision. Central venous pressure was maintained at approximately 0mmHg by controlling an infusion of sterile saline. Core body temperature decreased from 37.1+/-0.6degreesC (once instrumented) to 36.6+/-0.60degreesC (at the end of the study), despite warming using heating pads. Physiological parameters indicative of patient viability will generally decline during surgery without intervention. This study describes an approach that can be undertaken in veterinary hospitals to accurately monitor vital signs in surgical and critical care patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chronic hepatitis C is a major healthcare problem. The response to antiviral therapy for patients with chronic hepatitis C has previously been defined biochemically and by PCR. However, changes in the hepatic venous pressure gradient (HVPG) may be considered as an adjunctive end point for the therapeutic evaluation of antiviral therapy in chronic hepatitis C. It is a validated technique which is safe, well tolerated, well established, and reproducible. Serial HVPG measurements may be the best way to evaluate response to therapy in chronic hepatitis C.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. Portal pressure is measured invasively as Hepatic Venous Pressure Gradient (HVPG) in the angiography room. Liver stiffness measured by Fibroscan was shown to correlate with HVPG values below 12 mmHg. This is not surprising, since in cirrhosis the increase of portal pressure is not directly linked with liver fibrosis and consequently to liver stiffness. We hypothesized that, given the spleen’s privileged location upstream to the whole portal system, splenic stiffness could provide relevant information about portal pressure. Aim of the study was to assess the relationship between liver and spleen stiffness measured by Virtual Touch™ (ARFI) and HVPG in cirrhotic patients. METHODS. 40 consecutive patients (30 males, mean age 62y, mean BMI=26, mean Child-Pugh A6, mean platelet count=92.000/mmc, 19 HCV+, 7 with ascites) underwent to ARFI stiffness measurement (10 valid measurements in right liver lobe both surface and centre, left lobe and 20 in the spleen) and HPVG, blindly to each other. Median ARFI values of 10 samplings on every liver area and of 20 samplings on spleen were calculated. RESULTS. Stiffness could be easily measured in all patients with ARFI, resulting a mean of 2,61±0,76, 2,5±0,62 and 2,55±0,66 m/sec in the liver areas and 3.3±0,5 m/s in the spleen. Median HPVG was 14 mmHg (range 5-27); 28 patients showed values ≥10 mmHg. A positive significant correlation was found between spleen stiffness and HPVG values (r=0.744, p<0.001). No significant correlation was found between all liver stiffness and HVPG (p>0,05). AUROC was calculated to test spleen stiffness ability in discriminating patients with HVPG ≥10. AUROC = 0.911 was obtained, with sensitivity of 69% and specificity of 91% at a cut-off of 3.26 m/s. CONCLUSION. Spleen stiffness measurement with ARFI correlates with HVPG in patients with cirrhosis, with a potential of identifying patients with clinically significant portal hypertension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To demonstrate that abdominal pressure impacts venous flow and pressure characteristics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Blood loss and blood substitution are associated with higher morbidity after major abdominal surgery. During major liver resection, low local venous pressure, has been shown to reduce blood loss. Ambiguity persists concerning the impact of local venous pressure on blood loss during open radical cystectomy. We aimed to determine the association between intraoperative blood loss and pelvic venous pressure (PVP) and determine factors affecting PVP. MATERIAL AND METHODS In the frame of a single-center, double-blind, randomized trial, PVP was measured in 82 patients from a norepinephrine/low-volume group and in 81 from a control group with liberal hydration. For this secondary analysis, patients from each arm were stratified into subgroups with PVP <5 mmHg or ≥5 mmHg measured after cystectomy (optimal cut-off value for discrimination of patients with relevant blood loss according to the Youden's index). RESULTS Median blood loss was 800 ml [range: 300-1600] in 55/163 patients (34%) with PVP <5 mmHg and 1200 ml [400-3000] in 108/163 patients (66%) with PVP ≥5 mmHg; (P<0.0001). A PVP <5 mmHg was measured in 42/82 patients (51%) in the norepinephrine/low-volume group and 13/81 (16%) in the control group (P<0.0001). PVP dropped significantly after removal of abdominal packing and abdominal lifting in both groups at all time points (at begin and end of pelvic lymph node dissection, end of cystectomy) (P<0.0001). No correlation between PVP and central venous pressure could be detected. CONCLUSIONS Blood loss was significantly reduced in patients with low PVP. Factors affecting PVP were fluid management and abdominal packing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Liver regeneration is of crucial importance for patients undergoing living liver transplantations or extended liver resections and can be associated with elevated portal venous pressure, impaired hepatic regeneration, and postoperative morbidity. The aim of this study was to assess whether reduction of portal venous pressure by terlipressin improves postoperative liver regeneration in normal and steatotic livers after partial hepatectomy in a rodent model. METHODS Portal venous pressure was assessed after minor (30%), standard (60%), or extended (80%) partial hepatectomy (PH) in mice with and without liver steatosis. Liver regeneration was assessed by BrdU incorporation and Ki-67 immunostaining. RESULTS Portal venous pressure was significantly elevated post-PH in mice with normal and steatotic livers compared to sham-operated mice. Reduction of elevated portal pressure after 80% PH by terlipressin was associated with an increase of hepatocellular proliferation. In steatotic livers, animals treated with terlipressin had an increase in liver regeneration after 30% PH and increased survival after 60% PH. Mechanistically, terlipressin alleviated IL-6 mRNA expression following PH and down-regulated p21 and GADD45 mRNA suggesting a reduction of cell cycle inhibition and cellular stress. CONCLUSIONS Reduction of elevated portal pressure post-PH by the use of terlipressin improves liver regeneration after PH in lean and steatotic mouse livers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The effects of adrenergic stimulation on mean circulatory filling pressure (MCFP), central venous pressure (P-CV) and stroke volume (Vs), as well as the effects of altered MCFP through changes of blood volume were investigated in rattlesnakes (Crotalus durissus). MCFP is an estimate of the upstream pressure driving blood towards the heart and is determined by blood volume and the activity of the smooth muscle cells in the veins (venous tone). MCFP can be determined as the plateau in P-CV during a total occlusion of blood flow from the heart.Vs decreased significantly when MCFP was lowered by reducing blood volume in anaesthetised snakes, whereas increased MCFP through infusion of blood (up to 3 ml kg(-1)) only led to a small rise in Vs. Thus, it seems that end-diastolic volume is not affected by an elevated MCFP in rattlesnakes. To investigate adrenergic regulation on venous tone, adrenaline as well as phenylephrine and isoproterenol (alpha- and beta-adrenergic agonists, respectively) were infused as bolus injections (2 and 10 mu g kg(-1)). Adrenaline and phenylephrine caused large increases in MCFP and P-CV, whereas isoproterenol decreased both parameters. This was also the case in fully recovered snakes. Therefore, adrenaline affects venous tone through both alpha- and beta-adrenergic receptors, but the alpha-adrenergic receptor dominates at the dosages used in the present study. Injection of the nitric oxide donor SNP caused a significant decrease in P-CV and MCFP. Thus, nitric oxide seems to affect venous tone.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In critically ill patients, it is important to predict which patients will have their systemic blood flow increased in response to volume expansion to avoid undesired hypovolemia and fluid overloading. Static parameters such as the central venous pressure, the pulmonary arterial occlusion pressure, and the left ventricular end-diastolic dimension cannot accurately discriminate between responders and nonresponders to a fluid challenge. In this regard, respiratory-induced changes in arterial pulse pressure have been demonstrated to accurately predict preload responsiveness in mechanically ventilated patients. Some experimental and clinical studies confirm the usefulness of arterial pulse pressure as a useful tool to guide fluid therapy in critically ill patients.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: Assess the benefit of temporary caval stenting for remote venous drainage during cardiopulmonary bypass (CPB). METHODS: Temporary caval stenting was realized in bovine experiments (65+/-6 kg) by the means of self-expanding (18F for insertion, 36F in situ) venous cannulas (Smartcanula LLC, Lausanne, Switzerland) with various lengths: 43 cm, 53 cm, 63 cm vs. a standard 28F wire armed cannula in trans-jugular fashion. Maximal blood flows were assessed for 20, 25 and 30 mmHg of driving pressure with a motorized table height adjustment system. In addition, the inferior caval diameters (just above its bifurcation) were measured in real time with intra-vascular ultrasound (IVUS). RESULTS: Venous drainage (flow in l/min) at 20 mmHg, 25 mmHg, and 30 mmHg drainage load was 3.5+/-0.5, 3.7+/-0.7 and 4.0+/-0.6 for the 28F standard vs. 4.1+/-0.7, 4.0+/-1.3 and 3.9+/-1.1 for the 36F smart 43 cm, vs. 5.0+/-0.7, 5.3+/-1.3 and 5.4+/-1.4 for the 36F smart 53 cm, vs. 5.2+/-0.5*, 5.6+/-1.1* and 5.8+/-1.0* for the 36F smart 63 cm. The inferior vena caval diameters at 30 mmHg were 13.5+/-4.8 mm for 28F standard, 11.1+/-3.6 for 36F smart 43 cm, 11.3+/-3.2 for 36F 53 cm, and 17.0+/-0.1* for 36F 63 cm (*P<0.05 for 28F standard vs. 36F smart 63 cm long) CONCLUSIONS: The 43 cm self-expanding 36F smartcanula outperforms the 28F standard wire armed cannula at low drainage pressures and without augmentation. Temporary caval stenting with long self-expanding venous cannulas provides even better drainage (+51%).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: Transthoracic echocardiography (TTE) has been used clinically to disobstruct venous drainage cannula and to optimise placement of venous cannulae in the vena cava but it has never been used to evaluate performance capabilities. Also, little progress has been made in venous cannula design in order to optimise venous return to the heart lung machine. We designed a self-expandable Smartcanula (SC) and analysed its performance capability using echocardiography. METHODS: An epicardial echocardiography probe was placed over the SC or control cannula (CTRL) and a Doppler image was obtained. Mean (V(m)) and maximum (V(max)) velocities, flow and diameter were obtained. Also, pressure drop (DeltaP(CPB)) was obtained between the central venous pressure and inlet to venous reservoir. LDH and Free Hb were also compared in 30 patients. Comparison was made between the two groups using the student's t-test with statistical significance established when p<0.05. RESULTS: Age for the SC and CC groups were 61.6+/-17.6 years and 64.6+/-13.1 years, respectively. Weight was 70.3+/-11.6 kg and 72.8+/-14.4 kg, respectively. BSA was 1.80+/-0.2 m(2) and 1.82+/-0.2 m(2), respectively. CPB times were 114+/-53 min and 108+/-44 min, respectively. Cross-clamp time was 59+/-15 min and 76+/-29 min, respectively (p=NS). Free-Hb was 568+/-142 U/l versus 549+/-271 U/l post-CPB for the SC and CC, respectively (p=NS). LDH was 335+/-73 mg/l versus 354+/-116 mg/l for the SC and CC, respectively (p=NS). V(m) was 89+/-10 cm/s (SC) versus 63+/-3 cm/s (CC), V(max) was 139+/-23 cm/s (SC) versus 93+/-11 cm/s (CC) (both p<0.01). DeltaP(CPB) was 30+/-10 mmHg (SC) versus 43+/-13 mmHg (CC) (p<0.05). A Bland-Altman test showed good agreement between the two devices used concerning flow rate calculations between CPB and TTE (bias 300 ml+/-700 ml standard deviation). CONCLUSIONS: This novel Smartcanula design, due to its self-expanding principle, provides superior flow characteristics compared to classic two stage venous cannula used for adult CPB surgery. No detrimental effects were observed concerning blood damage. Echocardiography was effective in analysing venous cannula performance and velocity patterns.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: To investigate the hemodynamic effects of L-canavanine (an inhibitor of inducible, but not of constitutive, nitric oxide synthase) in endotoxic shock. DESIGN: Controlled, randomized, experimental study. SETTING: Animal laboratory. SUBJECTS: Wistar rats. INTERVENTIONS: Rats were anesthetized with pentobarbital, and hemodynamically monitored. One hour after an intravenous challenge with 5 mg/kg of Escherichia coli endotoxin, the rats were randomized to receive a continuous infusion of either L-canavanine (20 mg/kg/hr; n = 8) or vehicle only (isotonic saline, n = 11). In all animals, the infusion was given over 5 hrs at a rate of 2 mL/kg/hr. These experiments were repeated in additional rats challenged with isotonic saline instead of endotoxin (sham experiments). MEASUREMENTS AND MAIN RESULTS: Arterial blood pressure, heart rate, thermodilution cardiac output, central venous pressure, mean systemic filling pressure, urine output, arterial blood gases, blood lactate concentration, and hematocrit were measured. In sham experiments, hemodynamic stability was maintained throughout and L-canavanine had no detectable effect. Animals challenged with endotoxin and not treated with L-canavanine developed progressive hypotension and low cardiac output. After 6 hrs of endotoxemia, both central venous pressure and mean systemic filling pressure were significantly below their baseline values, indicating relative hypovolemia as the main determinant of reduced cardiac output. In endotoxemic animals treated with L-canavanine, hypotension was less marked, while cardiac output, central venous pressure, and mean systemic filling pressure were maintained throughout the experiment. L-canavanine had no effect on the time-course of hematocrit. L-canavanine significantly increased urine output and reduced the severity of lactic acidosis. CONCLUSIONS: Six hours after an endotoxin challenge in rats, low cardiac output develops, which appears to be primarily related to relative hypovolemia. L-canavanine, a selective inhibitor of the inducible nitric oxide synthase, increases the mean systemic filling pressure, thereby improving venous return, under these conditions.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: In cirrhosis, repeated flares of portal pressure and collateral blood flow provoked by postprandial hyperaemia may contribute to variceal dilation and rupture. Aim: To examine the effect of the extent of the collateral circulation on the postprandial increase in portal pressure observed in cirrhosis. Patients and methods: The hepatic venous pressure gradient (HVPG), hepatic blood flow and azygos blood flow were measured in 64 patients with cirrhosis before and after a standard liquid meal. Results: Peak increases in HVPG (median+14.9%), hepatic blood flow (median+25.4%), and azygos blood flow (median+32.2%) occurred at 30 min after the meal. Compared with patients with marked postprandial increase in HVPG (above the median, n¿=¿32), those showing mild (<15%, n¿=¿32) increase in HVPG had a higher baseline azygos flow (p<0.01) and underwent a greater postprandial increase in azygos flow (p<0.02). Hepatic blood flow increased similarly in both groups. Postprandial increases in HVPG were inversely correlated (p<0.001) with both baseline azygos flow (r¿=¿¿0.69) and its postprandial increase (r¿=¿¿0.72). Food intake increased nitric oxide products in the azygos (p<0.01), but not in the hepatic vein. Large varices (p<0.01) and previous variceal bleeding (p<0.001) were more frequent in patients with mild increase in HVPG. Conclusions: Postprandial hyperaemia simultaneously increases HVPG and collateral flow. The extent of the collateral circulation determines the HVPG response to food intake. Patients with extensive collateralisation show less pronounced postprandial increases in HVPG, but associated with marked flares in collateral flow. Collateral vessels preserve their ability to dilate in response to increased blood flow.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The objective of this study was to determine intraocular pressure (IOP) and cardiac changes in normocapnic dogs maintained under controlled ventilation and anesthetized using sevoflurane or desflurane. Sixteen healthy adult mixed-breed dogs, seven males and nine females, weighing 10-15 kg were used. The dogs were randomly assigned to one of two groups composed of eight animals anesthetized with sevoflurane (SEVO) or desflurane (DESF). In both groups, anesthesia was induced with propofol (10 mg/kg), and neuromuscular blockade was achieved with rocuronium (0.6 mg/kg/h IV). No premedication was given. Ventilation was adjusted to maintain end-tidal carbon dioxide partial pressure at 35 mmHg. Anesthesia was maintained with 1.5 minimum alveolar concentration (MAC) of sevoflurane or desflurane. In both groups IOP was measured by applanation tonometry (Tono-Pen) before induction of anesthesia. IOP, mean arterial pressure (MAP), heart rate (HR), cardiac index (CI) and central venous pressure (CVP) were also measured 45 min after the beginning of inhalant anesthesia and then every 20 min for 60 min. A one-way repeated measures ANOVA was used to compare data within the same group and Student's t-test was used to assess differences between groups. P < 0.05 was considered statistically significant. Measurements showed normal IOP values in both groups, even though IOP increased significantly from baseline during the use of desflurane. IOP did not differ between groups. CI in the desflurane group was significantly greater than in the sevoflurane group. Sevoflurane and desflurane have no clinically significant effects on IOP, MAP, HR, CI or VCP in the dog.