996 resultados para Valves (mechanical)


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Friction loss coefficients for laminar flow of xantan gum solutions (concentrations in the range of 0.1-0.5% by weight) through valves and fittings were experimentally determined. The rheological behavior, studied by means of a concentric cylinder rheometer, was pseudoplastic, being well described by the Ostwald-De Waele model with non-linear correlation coefficients (r) between 0.998 and 0.999. In the pressure drop measurements the following fittings were employed: completely open and half way open ball valve, completely open and half way open angle valve, tee used like coupling, tee used like a 90° elbow, short radius 90° elbow and coupling. The results showed that the friction loss coefficients increased with decreasing generalized Reynolds number. The friction loss coefficients could be well adjusted by a potential model, suggested by Kittredge & Rowley (1957) for Newtonian fluids, K f = A(Re g) -B, with correlation coefficients between 0.837 and 0.999.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this work is to characterize a metallic slurry (Al-4.5%Cu) flow during thixoforming of an automotive valve. The necessary globular structure was obtained by first inoculating the alloy with TIBAL (5%Ti, 1%B, Al - rest) at 750.0°C, and then reheating to a state between liquidus and solidus prior to thixoforming. Two metallic slurries, with a solid phase of approximately 86.1 and 78.2 percent, were used to generate different experimental flow patterns during the thixoforming process. The flow of the material into the die was observed for total, and partial displacement (2.7, 5.4, 7.5mm) of the punch. The first displacement shows formation of the valve rod. The patterns at each step of displacement of the punch were preserved by quenching in water, thus revealing the profile of the die fill and microstructural evolution. Degeneration of the globular phase was observed along the piece thixoextruded. Thixoextrusion forces versus time curves were generated for partial and full displacement of the punch. Porosity was visible along the billet prior to thixoforming. However, some areas show that the porosity gradually decreased to zero as the thixoextrusion pressure increased. Turbulent, transient and laminar flow are analyzed in this work.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work describes a fabrication and test sequence of microvalves installed on micronozzles. The technique used to fabricate the micronozzles was powder blasting. The microvalves are actuators made from PVDF (polivinylidene fluoride), that is a piezoelectric polymer. The micronozzles have convergent-divergent shape with external diameter of 1mm and throat around 230μm. The polymer have low piezoelectric coefficient, for this reason a bimorph structure with dimensions of 2mm width and 4mm of length was build (two piezoelectric sheets were glued together with opposite polarization). Both sheets are recovered with a conductor thin film used as electrodes. Applying a voltage between the electrodes one sheet expands while the other contracts and this generate a vertical movement to the entire actuator. Appling +300V DC between the electrodes the volume flux rate, for a pressure ratio of 0.5, was 0.36 sccm. Applying -200V DC between the electrodes (that means it closed) the volume flux rate was 0.32 sccm, defining a possible range of flow between 0.32 and 0.36 sccm. The third measurement was performed using AC voltage (200V AC with frequency of 1Hz), where the actuator was oscillating. For pressure ratio of 0.5, the flow rate was 0.62 sccm. © 2008 IOP Publishing Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aortic valve replacement using a tissue valve is controversial for patients younger than 60 years old. The long-term survival in this age group, the expected event rates during long-term follow-up, and valve-related complications are not clearly determined.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE OF REVIEW There is controversy regarding the optimal choice of prosthetic valves in patients less than 65 years of age requiring mitral valve replacement (MVR). Recently, trends for valve replacement are moving towards biological prosthesis also in younger patients, which is justified by the fact that a later valve-in-valve procedure is feasible in the case of degeneration of the tissue valve. This strategy is increasingly recommended in aortic valve surgery but is questionable for MVR. The purpose of this review is to evaluate current guidelines and analyse evidence for biological MVR in patients under 65 years. RECENT FINDINGS There are differences between guidelines of the American Heart Association and those of the European Society of Cardiology concerning the choice of prostheses in patients undergoing MVR. Although the European Society of Cardiology recommends a mechanical mitral valve in patients under 65 years of age, the American Heart Association does not provide detailed advice for these patients. Mitral valve replacement with biological valves in patients under 65 years is associated with higher rates of reoperation due to structural valve deterioration. In addition, several studies showed a decreased survival after biological MVR. SUMMARY Evidence for biological MVR in patients less than 65 years without comorbidities or contraindication for oral anticoagulation does not exist. Recommendations for patients less than 65 years of age should not be blurred by current 'en-vogue' methods for promising but not yet proven valve-in-valve strategies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Past work has clearly demonstrated that numerous commonly used metallic materials will support burning in oxygen, especially at higher pressures. An approach to rectify this significant safety problem has been successfully developed and implemented by applying the concept of Situational Non-Flammability. This approach essentially removes or breaks one leg of the conceptual fire triangle, a tool commonly used to define the three things that are required to support burning; a fuel, an ignition source and an oxidizer. Since an oxidiser is always present in an oxygen system as are ignition sources, the concept of Situational Non-Flammability essentially removes the fuel leg of the fire triangle by only utilising materials that will not burn at the maximum pressure, for example, that the control valve is to be used in. The utilisation of this approach has lead to the development of a range of oxygen components that are practically unable to burn while in service at their design pressure thus providing an unparalleled level of first safety while not compromising on the performance or endurance required in the function of these components. This paper describes the concept of Situational Non-Flammability, how it was used to theoretically evaluate designs of components for oxygen service and the outcomes of the actual development, fabrication and finally utilisation of these components in real oxygen systems in a range of flow control devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and aim of the study: The quantification of incidentally found aortic valve calcification on computed tomography (CT) is not performed routinely, as data relating to the accuracy of aortic valve calcium for estimating the severity of aortic stenosis (AS) is neither consistent nor validated. As aortic valve calcium quantification by CT is confounded by wall and coronary ostial calcification, as well as motion artifact, the ex-vivo micro-computed tomography (micro-CT) of stenotic aortic valves allows a precise measurement of the amounts of calcium present. The study aim, using excised aortic valves from patients with confirmed AS, was to determine if the amount of calcium on micro-CT correlated with the severity of AS. Methods: Each of 35 aortic valves that had been excised from patients during surgical valve replacement were examined using micro-CT imaging. The amount of calcium present was determined by absolute and proportional values of calcium volume in the specimen. Subsequently, the correlation between calcium volume and preoperative mean aortic valve gradient (MAVG), peak transaortic velocity (V-max), and aortic valve area (AVA) on echocardiography, was evaluated. Results: The mean calcium volume across all valves was 603.2 +/- 398.5 mm(3), and the mean ratio of calcium volume to total valve volume was 0.36 +/- 0.16. The mean aortic valve gradient correlated positively with both calcium volume and ratio (r = 0.72, p <0.001). V-max also correlated positively with the calcium volume and ratio (r = 0.69 and 0.76 respectively; p <0.001). A logarithmic curvilinear model proved to be the best fit to the correlation. A calcium volume of 480 mm(3) showed sensitivity and specificity of 0.76 and 0.83, respectively, for a diagnosis of severe AS, while a calcium ratio of 0.37 yielded sensitivity and specificity of 0.82 and 0.94, respectively. Conclusion: A radiological estimation of calcium amount by volume, and its proportion to the total valve volume, were shown to serve as good predictive parameters for severe AS. An estimation of the calcium volume may serve as a complementary measure for determining the severity of AS when aortic valve calcification is identified on CT imaging. The Journal of Heart Valve Disease 2012;21:320-327

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Phenolic resins when heat treated in inert atmosphere up to 1000 degreesC become glassy polymeric carbon (GPC), a chemically inert and biocompatible material useful for medical applications, such as in the manufacture of heart valves and prosthetic devices. In earlier work we have shown that ion bombardment can modify the surface of GPC, increasing its roughness. The enhanced roughness, which depends on the species, energy and fluence of the ion beam, can improve the biocompatibility of GPC prosthetic artifacts. In this work, ion bombardment was used to make a layer of implanted ions under the surface to avoid the propagation of microcracks in regions where cardiac valves should have pins for fixation of the leaflets. GPC samples prepared at 700 and 1500 degreesC were bombarded with ions of silicon. carbon, oxygen and gold at energies of 5, 6, 8 and 10 MeV, respectively, and fluences between 1.0 x 10(13) and 1.0 x 10(16) ions/cm(2). Nanoindentation hardness characterization was used to compare bombarded with non-bombarded samples prepared at temperatures up to 2500 degreesC. The results with samples not bombarded showed that the hardness of GPC increases strongly with the heat treatment temperature. Comparison with ion bombarded samples shows that the hardness changes according to the ion used, the energy and fluence. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stainless steels are used to intake and exhaust valves production applied as internal combustion engines. In general valves are requested to support cyclic stresses applied due to opening and closing processes during the operation. The objective of this research is to study the influence on the axial fatigue strength of the resulting microstructure after heat treatment at the martensitic X45CrSi93 steel, combined with different surface treatments as hard chrome-plating, nitride and grinding. It was verified a significant increase on the fatigue strength of the martensitic steel after nitriding, compared with results from the chrome-plating specimens. A slight increase in the tensile strength was also noticed on nitrided parts as a consequence of a resistance increase due to nitrogen and carbon solid solution. (C) 2011 Published by Elsevier Ltd. Selection and peer-review under responsibility of ICM11

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main goal of the present work is to verify the applicability of the Immersed Boundary Method together with the Virtual Physical Model to solve the flow through automatic valves of hermetic compressors. The valve was simplified to a two-dimensional radial diffuser, with diameter ratio of D/d = 1.5, and simulated for a one cycle of opening and closing process with a imposed velocity of 3.0 cm/s for the reed, dimensionless gap between disks in the range of 0.07 < s/d < 0.10, and inlet Reynolds number equal to 1500. The good results obtained showed that the methodology has great potential as project tool for this type of valve systems. © The Authors, 2011.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Calcific aortic valve disease (CAVD) is a chronic disorder characterized by an abnormal mineralization of the leaflets, which is accelerated in bicuspid aortic valve (BAV). It is suspected that mechanical strain may promote/enhance mineralization of the aortic valve. However, the effect of mechanical strain and the involved pathways during mineralization of the aortic valve remains largely unknown. Valve interstitial cells (VICs) were isolated and studied under strain conditions. Human bicuspid aortic valves were examined as a model relevant to increase mechanical strain. Cyclic strain increased mineralization of VICs by several-fold. Scanning electron microscope (SEM) and energy dispersive X-ray (EDX) analyses revealed that mechanical strain promoted the formation of mineralized spheroid microparticles, which coalesced into larger structure at the surface of apoptotic VICs. Apoptosis and mineralization were closely associated with expression of ENPP1. Inhibition of ENPP1 greatly reduced mineralization of VIC cultures. Through several lines of evidence we showed that mechanical strain promoted the export of ENPP1-containing vesicles to the plasma membrane through a RhoA/ROCK pathway. Studies conducted in human BAV revealed the presence of spheroid mineralized structures along with the expression of ENPP1 in areas of high mechanical strain. Mechanical strain promotes the production and accumulation of spheroid mineralized microparticles by VICs, which may represent one important underlying mechanism involved in aortic valve mineralization. RhoA/ROCK-mediated export of ENPP1 to the plasma membrane promotes strain-induced mineralization of VICs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The closing sounds of mechanical heart valves can be disturbing for patients and their closest relatives. Although some investigations into mechanical heart valve sounds have been performed, the particularities of the valve sound when it is attached to a vascular prosthesis to replace the aortic root and the ascending aorta has not been studied to date. The study aim was to compare the closing sounds of three various mechanical composite graft prostheses, and to analyze the impact of such sounds on the patients' quality of life.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

IMPORTANCE Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES Survival, stroke, and New York Heart Association functional class. RESULTS Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.