902 resultados para VENTILATORY THRESHOLDS
Resumo:
This study investigated if there were acute interference effects of strength exercises on subsequent continuous and intermittent 5Km aerobic exercises. Eleven physically active males (23.1 +/- 3.1 yrs, 1.75 +/- 0.07 m, 70.5 +/- 8.8 kg, and 58.2 +/- 8.3 VO(2)max) performed the following experimental sessions: A) 5 sets of 5 RM on the leg press followed by a 5km run performed continuously (average velocity of the first and second ventilatory thresholds, nu Delta 50), B) 5 sets of 5 RM on the leg press followed by a 5km run performed intermittently (1 min run at the nu VO(2)max : 1 min of rest); C) 2 sets of 15 RM on the leg press followed by a 5km continuous run; and D) 2 sets of 15 RM on the leg press followed by a 5km intermittent run. Heart rate, blood lactate concentration, rate of perceived exertion, and VO(2) at the first and the fifth km were considered for statistical purposes. There were no significant effects of both strength bouts on any of the variables associated with endurance performance (p > 0.05). It seems that both maximum and strength endurance bouts do not acutely impair aerobic performance.
Resumo:
Exercise intensity is a key parameter for exercise prescription but the optimal range for individuals with high cardiorespiratory fitness is unknown. The aims of this study were (1) to determine optimal heart rate ranges for men with high cardiorespiratory fitness based on percentages of maximal oxygen consumption (%VO(2max)) and reserve oxygen consumption (%VO(2reserve)) corresponding to the ventilatory threshold and respiratory compensation point, and ( 2) to verify the effect of advancing age on the exercise intensities. Maximal cardiorespiratory testing was performed on 210 trained men. Linear regression equations were calculated using paired data points between percentage of maximal heart rate (%HR(max)) and %VO(2max) and between percentage of heart rate reserve (%HRR) and %VO(2reserve) attained at each minute during the test. Values of %VO(2max) and %VO(2reserve) at the ventilatory threshold and respiratory compensation point were used to calculate the corresponding values of %HRmax and %HRR, respectively. The ranges of exercise intensity in relation to the ventilatory threshold and respiratory compensation point were achieved at 78-93% of HR(max) and 70-93% of HRR, respectively. Although absolute heart rate decreased with advancing age, there were no age-related differences in %HR(max) and %HRR at the ventilatory thresholds. Thus, in men with high cardiorespiratory fitness, the ranges of exercise intensity based on %HR(max) and %HRR regarding ventilatory threshold were 78-93% and 70-93% respectively, and were not influenced by advancing age.
Resumo:
The aim of this study was to examine the effects of low carbohydrate (CHO) availability on heart rate variability (HRV) responses during moderate and severe exercise intensities until exhaustion. Six healthy males (age, 26.5 +/- 6.7 years; body mass, 78.4 +/- 7.7 kg; body fat %, 11.3 +/- 4.5%; (V) over dotO(2max), 39.5 +/- 6.6 mL kg(-1) min(-1)) volunteered for this study. All tests were performed in the morning, after 8-12 h overnight fasting, at a moderate intensity corresponding to 50% of the difference between the first (LT(1)) and second (LT(2)) lactate breakpoints and at a severe intensity corresponding to 25% of the difference between the maximal power output and LT(2). Forty-eight hours before each experimental session, the subjects performed a 90-min cycling exercise followed by 5-min rest periods and subsequent 1-min cycling bouts at 125% (V) over dotO(2max) (with 1-min rest periods) until exhaustion, in order to deplete muscle glycogen. A diet providing 10% (CHO(low)) or 65% (CHO(control)) of energy as carbohydrates was consumed for the following 2 days until the experimental test. The Poicare plots (standard deviations 1 and 2: SD1 and SD2, respectively) and spectral autoregressive model (low frequency LF, and high frequency HF) were applied to obtain HRV parameters. The CHO availability had no effect on the HRV parameters or ventilation during moderate-intensity exercise. However, the SD1 and SD2 parameters were significantly higher in CHO(low) than in CHO(control), as taken at exhaustion during the severe-intensity exercise (P < 0.05). The HF and LF frequencies (ms(2)) were also significantly higher in CHO(low) than in CHO(control) (P < 0.05). In addition, ventilation measured at the 5 and 10-min was higher in CHO(low) (62.5 +/- 4.4 and 74.8 +/- 6.5 L min(-1), respectively, P < 0.05) than in CHO(control) (70.0 +/- 3.6 and 79.6 +/- 5.1 L min(-1), respectively; P < 0.05) during the severe-intensity exercise. These results suggest that the CHO availability alters the HRV parameters during severe-, but not moderate-, intensity exercise, and this was associated with an increase in ventilation volume.
Resumo:
This study compared measurements of upper body aerobic fitness in elite (EC; n = 7) and intermediate rock climbers (IC; n = 7), and a control group (C; n = 7). Subjects underwent an upper limb incremental test on hand cycle ergometer, with increments of 23 W.min(-1), until exhaustion. Ventilation (VE) data were smoothed to 10 s averages and plotted against time for the visual determination of the first (VT1) and second (VT2) ventilatory thresholds. Peak power output was not different among groups [EC = 130.9 (+/- 11.8) W; IC = 122.1 (+/- 28.4) W; C = 115.4 (+/- 15.1) W], but time to exhaustion was significantly higher in EC than IC and C. VO(2PEAK) was significantly higher in EC [36.8 (+/- 5.7) mL.kg(-1).min(-1)] and IC [35.5 (+/- 5.2) mL.kg(-1).min(-1)] than C [28.8 (+/- 5.0) mL.kg(-1).min(-1)], but there was no difference between EC and IC. VT1 was significantly higher in EC than C [EC = 69.0 (+/- 9.4) W; IC = 62.4 (+/- 13.0) W; C = 52.1 (+/- 11.8) W], but no significant difference was observed in VT2 [EC = 103.5 (+/- 18.8) W; IC = 92.0 (+/- 22.0) W; C = 85.6 (+/- 19.7) W]. These results show that elite indoor rock climbers elicit higher aerobic fitness profile than control subjects when measured with an upper body test.
Resumo:
Pinto, ALS, Oliveira, NC, Gualano, B, Christmann, RB, Painelli, VS, Artioli, GG, Prado, DML, and Lima, FR. Efficacy and safety of concurrent training in systemic sclerosis. J Strength Cond Res 25(5): 1423-1428, 2011-The optimal training model for patients with systemic sclerosis (SSc) is unknown. In this study, we aimed to investigate the effects of a 12-week combined resistance and aerobic training program (concurrent training) in SSc patients. Eleven patients with no evidence of pulmonary involvement were recruited for the exercise program. Lower and upper limb dynamic strengths (assessed by 1 repetition maximum [1RM] of a leg press and bench press, respectively), isometric strength (assessed by back pull and handgrip tests), balance and mobility (assessed by the timed up-and-go test), muscle function (assessed by the timed-stands test), Rodnan score, digital ulcers, Rayland`s phenomenon, and blood markers of muscle inflammation (creatine kinase and aldolase) were assessed at baseline and after the 12-week program. Exercise training significantly enhanced the 1RM leg press (41%) and 1RM bench press (13%) values and back pull (24%) and handgrip strength (11%). Muscle function was also improved (15%), but balance and mobility were not significantly changed. The time-to-exhaustion was increased (46.5%, p = 0.0004), the heart rate at rest condition was significantly reduced, and the workload and time of exercise at ventilatory thresholds and peak of exercise were increased. However, maximal and submaximal (V)over dotO(2) were unaltered (p > 0.05). The Rodnan score was unchanged, and muscle enzymes remained within normal levels. No change was observed in digital ulcers and Raynaud`s phenomenon. This is the first study to demonstrate that a 12-week concurrent training program is safe and substantially improves muscle strength, function, and aerobic capacity in SSc patients.
Resumo:
This study examined the effects of four high-intensity interval-training (HIT) sessions performed over 2 weeks on peak volume of oxygen uptake (VO2peak), the first and second ventilatory thresholds (UT VT2) and peak power output (PPO) in highly trained cyclists. Fourteen highly trained male cyclists (VO2peak = 67.5 +/- 3.7 ml . kg(-1) . min(-1)) performed a ramped cycle test to determine VO2peak VT1 VT2, and PPO. Subjects were divided equally into a HIT group and a control group. The HIT group performed four HIT sessions (20 x 60 s at PPO, 120 s recovery); the V-02peak test was repeated <I wk after the HIT program. Control subjects maintained their regular training program and were reassessed under the same timeline. There was no change in V0(2peak) for either group; however, the HIT group showed a significantly greater increase in VT1, (+22% vs. -3%), VT2 (+15% vs. -1%), and PPO (+4.3 vs. -.4%) compared to controls (all P <.05). This study has demonstrated that HIT can improve VT1, VT2,, and PPO, following only four HIT sessions in already highly trained cyclists.
Resumo:
The aim of this study was to compare the cycling performance of cyclists and triathletes. Each week for 3 weeks, and on different days, 25 highly trained male cyclists and 18 highly trained male triathletes performed: (1) an incremental exercise test on a cycle ergometer for the determination of peak oxygen consumption ((V) over dot O-2peak), peak power output and the first and second ventilatory thresholds, followed 15 min later by a sprint to volitional fatigue at 150% of peak power output; (2) a cycle to exhaustion test at the (V) over dot O-2peak power output; and (3) a 40-km cycle time-trial. There were no differences in (V) over dot O-2peak, peak power output, time to volitional fatigue at 150% of peak power output or time to exhaustion at (V) over dot O-2peak power output between the two groups. However, the cyclists had a significantly faster time to complete the 40-km time-trial (56:18 +/- 2:31 min:s; mean +/- s) than the triathletes (58:57 +/- 3:06 min:s; P < 0.01), which could be partially explained (r = 0.34-0.51; P < 0.05) by a significantly higher first (3.32 +/- 0.36 vs 3.08 +/- 0.36 l . min(-1)) and second ventilatory threshold (4.05 +/- 0.36 vs 3.81 +/- 0.29 l . min(-1); both P < 0.05) in the cyclists compared with the triathletes. In conclusion, cyclists may be able to perform better than triathletes in cycling time-trial events because they have higher first and second ventilatory thresholds.
Resumo:
Introduction. Respiratory difficulties in athletes are common, especially in adolescents, even in the absence of exercise-induced bronchoconstriction. Immaturity of the respiratory muscles coupling at high respiratory rates could be a potential mechanism. Whether respiratory muscle training (RMT) can positively influence it is yet unknown. Goal. We investigate the effects of RMT on ventilation and performance parameters in adolescent athletes and hypothesize that RMT will enhance respiratory capacity. Methods. 12 healthy subjects (8 male, 4 female, 17±0.5 years) from a sports/study high school class, competitively involved in various sports (minimum of 10 hours per week) underwent respiratory function testing, maximal minute ventilation (MMV) measurements and a maximal treadmill incremental test with VO2max and ventilatory thresholds (VT1 and VT2) determination. They then underwent one month of RMT (4 times/week) using a eucapnic hyperventilation device, with an incremental training program. The same tests were repeated after RMT. Results. Subjects completed 14.8 sessions of RMT, with an increase in total ventilation per session of 211±29% during training. Borg scale evaluation of the RMT session was unchanged or reduced in all subjects, despite an increase in total respiratory work. No changes (p>0.05) were observed pre/post RMT in VO2max (53.4±7.5 vs 51.6±7.7 ml/kg/min), VT2 (14.4±1.4 vs 14.0±1.1 km/h) or Speed max at end of test (16.1±1.7 vs 15.8±1.7 km/h). MVV increased by 9.2% (176.7±36.9 vs 192.9±32.6 l/min, p<0.001) and FVC by 3.3% (6.70±0.75 vs 4.85±0.76 litres, p<0.05). Subjective evaluation of respiratory sensations during exercise and daily living were also improved. Conclusions. RMT improves MMV and FVC in adolescent athletes, along with important subjective respiratory benefits, although no changes are seen in treadmill maximal performance tests and VO2max measurements. RMT can be easily performed in adolescent without side effects, with a potential for improvement in training capacity and overall well-being.
Resumo:
This study aimed to characterise both the [Formula: see text] kinetics within constant heavy-intensity swimming exercise, and to assess the relationships between [Formula: see text] kinetics and other parameters of aerobic fitness, in well-trained swimmers. On separate days, 21 male swimmers completed: (1) an incremental swimming test to determine their maximal oxygen uptake [Formula: see text], first ventilatory threshold (VT), and the velocity associated with [Formula: see text] [Formula: see text] and (2) two square-wave transitions from rest to heavy-intensity exercise, to determine their [Formula: see text] kinetics. All the tests involved breath-by-breath analysis of freestyle swimming using a swimming snorkel. [Formula: see text] kinetics was modelled with two exponential functions. The mean values for the incremental test were 56.0 ± 6.0 ml min(-1) kg(-1), 1.45 ± 0.08 m s(-1); and 42.1 ± 5.7 ml min(-1) kg(-1) for [Formula: see text], [Formula: see text] and VT, respectively. For the square-wave transition, the time constant of the primary phase (τ(p)) averaged 17.3 ± 5.4 s and the relevant slow component (A'(sc)) averaged 4.8 ± 2.9 ml min(-1) kg(-1) [representing 8.9% of the end-exercise [Formula: see text] (%A'(sc))]. τ(p) was correlated with [Formula: see text] (r = -0.55, P = 0.01), but not with either [Formula: see text] (r = 0.05, ns) or VT (r = 0.14, ns). The %A'(sc) did not correlate with either [Formula: see text] (r = -0.14, ns) or [Formula: see text] (r = 0.06, ns), but was inversely related with VT (r = -0.61, P < 0.01). This study was the first to describe the [Formula: see text] kinetics in heavy-intensity swimming using specific swimming exercise and appropriate methods. As has been demonstrated in cycling, faster [Formula: see text] kinetics allow higher aerobic power outputs to be attained. The slow component seems to be reduced in swimmers with higher ventilatory thresholds.
Resumo:
The aim of this study was to locate the breakpoints of cerebral and muscle oxygenation and muscle electrical activity during a ramp exercise in reference to the first and second ventilatory thresholds. Twenty-five cyclists completed a maximal ramp test on an electromagnetically braked cycle-ergometer with a rate of increment of 25 W/min. Expired gazes (breath-by-breath), prefrontal cortex and vastus lateralis (VL) oxygenation [Near-infrared spectroscopy (NIRS)] together with electromyographic (EMG) Root Mean Square (RMS) activity for the VL, rectus femoris (RF), and biceps femoris (BF) muscles were continuously assessed. There was a non-linear increase in both cerebral deoxyhemoglobin (at 56 ± 13% of the exercise) and oxyhemoglobin (56 ± 8% of exercise) concomitantly to the first ventilatory threshold (57 ± 6% of exercise, p > 0.86, Cohen's d < 0.1). Cerebral deoxyhemoglobin further increased (87 ± 10% of exercise) while oxyhemoglobin reached a plateau/decreased (86 ± 8% of exercise) after the second ventilatory threshold (81 ± 6% of exercise, p < 0.05, d > 0.8). We identified one threshold only for muscle parameters with a non-linear decrease in muscle oxyhemoglobin (78 ± 9% of exercise), attenuation in muscle deoxyhemoglobin (80 ± 8% of exercise), and increase in EMG activity of VL (89 ± 5% of exercise), RF (82 ± 14% of exercise), and BF (85 ± 9% of exercise). The thresholds in BF and VL EMG activity occurred after the second ventilatory threshold (p < 0.05, d > 0.6). Our results suggest that the metabolic and ventilatory events characterizing this latter cardiopulmonary threshold may affect both cerebral and muscle oxygenation levels, and in turn, muscle recruitment responses.
Resumo:
Buchheit, M, Al Haddad, H, Millet GP, Lepretre, PM, Newton, M, and Ahmaidi, S. Cardiorespiratory and cardiac autonomic responses to 30-15 Intermittent Fitness Test in team sport players. J Strength Cond Res 23(1): xxx-xxx, 2009-The 30-15 Intermittent Fitness Test (30-15IFT) is an attractive alternative to classic continuous incremental field tests for defining a reference velocity for interval training prescription in team sport athletes. The aim of the present study was to compare cardiorespiratory and autonomic responses to 30-15IFT with those observed during a standard continuous test (CT). In 20 team sport players (20.9 +/- 2.2 years), cardiopulmonary parameters were measured during exercise and for 10 minutes after both tests. Final running velocity, peak lactate ([La]peak), and rating of perceived exertion (RPE) were also measured. Parasympathetic function was assessed during the postexercise recovery phase via heart rate (HR) recovery time constant (HRRtau) and HR variability (HRV) vagal-related indices. At exhaustion, no difference was observed in peak oxygen uptake (&OV0312;o2peak), respiratory exchange ratio, HR, or RPE between 30-15IFT and CT. In contrast, 30-15IFT led to significantly higher minute ventilation, [La]peak, and final velocity than CT (p < 0.05 for all parameters). All maximal cardiorespiratory variables observed during both tests were moderately to well correlated (e.g., r = 0.76, p = 0.001 for &OV0312;o2peak). Regarding ventilatory thresholds (VThs), all cardiorespiratory measurements were similar and well correlated between the 2 tests. Parasympathetic function was lower after 30-15IFT than after CT, as indicated by significantly longer HHRtau (81.9 +/- 18.2 vs. 60.5 +/- 19.5 for 30-15IFT and CT, respectively, p < 0.001) and lower HRV vagal-related indices (i.e., the root mean square of successive R-R intervals differences [rMSSD]: 4.1 +/- 2.4 and 7.0 +/- 4.9 milliseconds, p < 0.05). In conclusion, the 30-15IFT is accurate for assessing VThs and &OV0312;o2peak, but it alters postexercise parasympathetic function more than a continuous incremental protocol.
Resumo:
Many investigations have shown that the coincidence between the ventilatory thresholds and those thresholds using the lactate response does not happen all of the time, suggesting that there is no relationship between the cause-effect between these phenomena. Thus, the present study had as main purpose to compare and correlate the Oxygen consumption (V̇O 2), the power (W), and the heart rate (HR) values attained using protocols to determine the Ventilatory Threshold (VT) and the Individual Anaerobic Threshold (IAT). The sampling was constituted by eight State and National level cyclists (age: 27.88 ± 8.77 years; body mass: 65.19 ± 4.40 kg; height: 169.31 ± 5,77 cm). The IAT was determined starting from a three minutes 50 W warm up with progressive increases of 50 W.3min -1 up to achieving the voluntary exhaustion, when the blood was collected in the last 20 seconds of each phase, and during the recovering period. In order to determine the VT, it was used the same protocol used to determine the IAT, but without performing the blood collection. The VT was identified through the changes in the pulmonary ventilation, as well as of the ventilatory equivalent of the O 2 and CO 2. The t-Student test showed no significant statistical difference in any of the attained variables. The associations found were high and significant. The V̇O 2 (ml.kg -1.min. -1), P (W), and HR (bpm) corresponding to the VT and IAT, as well as the associations between variables were respectively: 48.00 ± 3.82 vs. 48.08 ± 3.71 (r = 0.90); 256.25 ± 32.04 vs. 246.88 ± 33.91 (r = 0.84); 173.75 ± 9.18 vs. 171.25 ± 12.02 (r = 0.97). According to the results attained, it can be concluded that the IAT and the VT produce similar V̇O 2, W, and HR values, favoring the adoption of the VT because it is a non-invasive method to determine the anaerobic threshold in cyclists.
Resumo:
Pós-graduação em Fisioterapia - FCT
Resumo:
The aims were both to determine lactate and ventilatory threshold during incremental resistance training and to analyze the acute cardiorespiratory and metabolic responses during constant-load resistance exercise at lactate threshold (LT) intensity. Ten healthy men performed 2 protocols on leg press machine. The incremental test was performed to determine the lactate and ventilatory thresholds through an algorithmic adjustment method. After 48 h, a constant-load exercise at LT intensity was executed. The intensity of LT and ventilatory threshold was 27.1 +/- 3.7 and 30.3 +/- 7.9% of 1RM, respectively (P=0.142). During the constant-load resistance exercise, no significant variation was observed between set 9 and set 15 for blood lactate concentration (3.3 +/- 0.9 and 4.1 +/- 1.4 mmol.L-1, respectively. P=0.166) and BORG scale (11.5 +/- 2.9 and 13.0 +/- 3.5, respectively. P=0.783). No significant variation was observed between set 6 and set 15 for minute ventilation (19.4 +/- 4.9 and 22.4 +/- 5.5L. min(-1), respectively. P=0.091) and between S3 and S15 for VO2 (0.77 +/- 0.18 and 0.83 +/- 0.16L. min(-1), respectively. P=1.0). Constant-load resistance exercise at LT intensity corresponds to a steady state of ventilatory, cardio-metabolic parameters and ratings of perceived exertion.