982 resultados para Uv Spectroscopy
Resumo:
Homeopathic preparations are used in homeopathy and anthroposophic medicine. Although there is evidence of effectiveness in several clinical studies, including double-blinded randomized controlled trials, their nature and mode of action could not be explained with current scientific approaches yet. Several physical methods have already been applied to investigate homeopathic preparations but it is yet unclear which methods are best suited to identify characteristic physicochemical properties of homeopathic preparations. The aim of this study was to investigate homeopathic preparations with UV-spectroscopy. In a blinded, randomized, controlled experiment homeopathic preparations of copper sulfate (CuSO(4); 11c-30c), quartz (SiO(2); 10c-30c, i.e., centesimal dilution steps) and sulfur (S; 11×-30×, i.e., decimal dilution steps) and controls (one-time succussed diluent) were investigated using UV-spectroscopy and tested for contamination by inductively coupled plasma mass spectrometry (ICP-MS). The UV transmission for homeopathic preparations of CuSO(4) preparations was significantly lower than in controls. The transmission seemed to be also lower for both SiO(2) and S, but not significant. The mean effect size (95% confidence interval) was similar for the homeopathic preparations: CuSO(4) (pooled data) 0.0544% (0.0260-0.0827%), SiO(2) 0.0323% (-0.0064% to 0.0710%) and S 0.0281% (-0.0520% to 0.1082%). UV transmission values of homeopathic preparations had a significantly higher variability compared to controls. In none of the samples the concentration of any element analyzed by ICP-MS exceeded 100 ppb. Lower transmission of UV light may indicate that homeopathic preparations are less structured or more dynamic than their succussed pure solvent.
Resumo:
Purpose: Homeopathic preparations are used in homeopathy and anthroposophically extended medicine. Previous studies described differences in UV transmission between homeopathic preparations of CuSO4 and controls. The aim of the present study was to investigate whether statistically significant differences can be found between homeopathic verum and placebo globules by UV spectroscopy. Methods: Verum (aconitum 30c, calcium carbonate/quercus e cortice) and placebo globules used in two previous clinical trials were dissolved in distilled water at 10mg/ml 20-23h prior to the measurements. Absorbance was measured at 190 – 340nm with a Shimadzu UV-1800 double beam spectrophotometer. Duplicates of each sample were measured in a randomized order 4 times on each of the 5 measurement days. To correct for differences between measurement days, average absorbance of all samples on one day was deduced from absorbance of the individual samples. The Kruskal-Wallis test was used to determine group differences between the samples, and finally the coding of the samples was revealed. Results: First analysis showed significant differences (p≤0.05) in average UV absorbance at 200 – 290nm between the samples and a tendency of a correlation (p≤0.1) between absorbance and globule weight. More results will be presented at the conference. Conclusion: Since the absorbance of the samples at the wavelengths between 200 and 290nm was small, a number of aspects had to be considered and should be corrected for if they are present when performing UV spectroscopy on homeopathic globules: 1. Exact weighing of the globules. 2. Measurement error of the spectrophotometer at small absorbances. 3. Drift of the spectrophotometer during a measurement day. 4. Differences between measurement days. The question remains what caused the differences in absorbance found in these experiments: the use of the original material for the production of the verum globules, differences in the production of verum and placebo globules, or other context factors.
Resumo:
This paper details methodologies that have been explored for the fast proofing of on-chip architectures for Circular Dichroism techniques. Flow-cell devices fabricated from UV transparent Quartz are used for these experiments. The complexity of flow-cell production typically results in lead times of six months from order to delivery. Only at that point can the on-chip architecture be tested empirically and any required modifications determined ready for the next six month iteration phase. By using the proposed 3D printing and PDMS moulding techniques for fast proofing on-chip architectures the optimum design can be determined within a matter of hours prior to commitment to quartz chip production.
Resumo:
Electrodegradation of atrazine in water was performed using homemade (PA and PB) and purchased (PC) boron-doped diamond anodes. The degradation was monitored off-line by analyzing total organic carbon and high performance liquid chromatography with diode array detector (HPLC-DAD) and at-line by UV spectroscopy. The spectra were recorded every 2 min. The rank deficiency problem was resolved by assembling an augmented column-wise matrix. HPLC was employed to separate the original and byproducts degradation components. Aiming the same goal, multivariate curve resolution - alternating least squares (MCR-ALS) was applied to resolve the UV spectroscopic data. Comparison between HPLC and MCR-ALS separations is presented. By using MCR-ALS the spectra of atrazine and two byproducts were successfully resolved and the resulted concentration profiles properly represented the system studied. The ALS explained variance (R2) for PA, PB and PC was equal to 99.99% for all of them and the lack of fit for PA, PB and PC were 0.39, 0.34 and 0.54 respectively. The correlation (R) between the recovered and pure spectra were calculate for each electrodegradation, validating the MCR-ALS results. The average R was equal to 0.997. The spectral and concentration profiles described with this new approach are in agreement with HPLC-DAD results. The proposed method is an alternative to classical analyses for monitoring of the degradation process, mainly due to the simplicity, fast results and economy.
Resumo:
Clinical trials have reported statistically significant and clinically relevant effects of homeopathic preparations. We applied ultraviolet (UV) spectroscopy to investigate the physical properties of homeopathic preparations and to contribute to an understanding of the not-yet-identified mode of action. In previous investigations, homeopathic preparations had significantly lower UV light transmissions than controls. The aim of this study was to explore the possible effects of external factors (UV light and temperature) on the homeopathic preparations. Homeopathic centesimal (c) dilutions, 1c to 30c, of copper sulfate (CuSO(4)), decimal dilutions of sulfur (S(8)), 1x to 30x, and controls (succussed potentization medium) were prepared, randomized, and blinded. UV transmission was measured at six different time points after preparation (from 4 to 256 days). In addition, one series of samples was exposed to UV light of a sterilization lamp for 12 h, one was incubated at 37 degrees Celsius for 24 h, and one was heated to 90 degrees Celsius for 15 min. UV light transmission values from 190 or 220 nm to 340 nm were measured several times and averaged. After each exposure, UV transmission of the homeopathic preparations of CuSO(4) was significantly reduced compared to the controls, particularly after heating to 37 degrees Celsius. Overall, the nonexposed CuSO(4) preparations did not show significantly lower UV transmission compared to controls; however, the pooled subgroup of measurements at days 26, 33, and 110 yielded significant differences. UV light transmission for S(8) preparations did not show any differences compared to controls. Our conclusion is that exposure to external factors, incubation at 37 degrees Celsius in particular, increases the difference in light transmission of homeopathic CuSO(4) preparations compared to controls.
Resumo:
Background: High and ultra-high dilutions of various starting materials, e.g. copper sulfate, Hypericum perforatum and sulfur, showed significant differences in ultraviolet light (UV) transmission from controls and amongst different dilution levels [1,2]. Verum and placebo globules of Aconitum napellus 30c or calcium carbonate/quercus e cortice 6x from the same packs as used in previous clinical trials and dissolved in water could be distinguished by UV spectroscopy [3]. However, it was unclear whether the differences in UV absorbance originated from specific characteristics of the starting materials, from differences in the production of verum and placebo globules, and/or other unknown interference factors. Aims: The aim of this study was to investigate whether globules produced with high and ultra-high dilutions (6x, 12x, 30c, 200c, 200CF (centesimal discontinuous fluxion), 10,000CF) of various starting materials (Aconitum napellus, Atropa belladonna, phosphorus, sulfur, Apis mellifica, quartz) could be distinguished by UV spectroscopy. Methodology: The globules were specially produced for this study by Spagyros AG (Gümligen, Switzerland) and differed only in the starting materials of the dilutions (but not in the batch of globules or ethanol used). Globules were dissolved in water at 10 mg/ml, in quadruplicates, approximately 22 h prior to the measurements. Absorbance of the samples in the UV range (from 190 to 340 nm) was measured in a randomized order with a Shimadzu double beam UV-1800 spectrophotometer equipped with an auto sampler. Samples of each starting material were prepared and measured on 5 independent days. The daily variations of the spectrophotometer as well as the drift during the measurements were corrected for. The average absorbance from 200 to 340 nm was compared among various starting materials within equal dilution levels using a Kruskal-Wallis test. Results: Statistically significant differences were found among 30c (Figure 1), 200c and 200CF dilutions of the various starting materials. No differences were found among 6x, 12x and 10,000CF dilutions. Conclusions: Globules prepared from high dilutions of various starting materials may show significantly different UV absorbance when dissolved in water. References [1] Wolf U, Wolf M, Heusser P, Thurneysen A, Baumgartner S. Homeopathic preparations of quartz, sulfur and copper sulfate assessed by UV-spectroscopy. Evid Based Complement Alternat Med. 2011;2011:692798. [2] Klein SD, Sandig A, Baumgartner S, Wolf U. Differences in median ultraviolet light transmissions of serial homeopathic dilutions of copper sulfate, Hypericum perforatum, and sulfur. Evid Based Complement Alternat Med. 2013;2013:370609. [3] Klein SD, Wolf U. Investigating homeopathic verum and placebo globules with ultraviolet spectroscopy. Forsch Komplementmed. 2013, accepted.
Resumo:
A combined and sequential use of Monte Carlo simulations and quantum mechanical calculations is made to analyze the spectral shift of the lowest pi-pi* transition of phenol in water. The solute polarization is included using electrostatic embedded calculations at the MP2/aug-cc-pVDZ level giving a dipole moment of 2.25 D, corresponding to an increase of 76% compared to the calculated gas-phase value. Using statistically uncorrelated configurations sampled from the MC simulation,first-principle size-extensive calculations are performed to obtain the solvatochromic shift. Analysis is then made of the origin of the blue shift. Results both at the optimized geometry and in room-temperature liquid water show that hydrogen bonds of water with phenol promote a red shift when phenol is the proton-donor and a blue shift when phenol is the proton-acceptor. In the case of the optimized clusters the calculated shifts are in very good agreement with results obtained from mass-selected free jet expansion experiments. In the liquid case the contribution of the solute-solvent hydrogen bonds partially cancels and the total shift obtained is dominated by the contribution of the outer solvent water molecules. Our best result, including both inner and outer water molecules, is 570 +/- 35 cm(-1), in very good agreement with the small experimental shift of 460 cm(-1) for the absorption maximum.
Resumo:
Organosolv lignins can replace petroleum chemicals such as phenol either partially or totally in various applications. Eight lignins, seven of which corresponded to the ethanol-water fractionation of bagasse and the other to a reference lignin (Alcell (R)) were analyzed with the aim to evaluate their chemical and physicochemical characteristics. The purity of the lignin fractions was determined by high pressure liquid chromatography (HPLC) and by ash content. Fourier Transform-Infrared Spectroscopy (FTIR) techniques and differential UV spectroscopy were applied to identify the chemical groups in the lignin samples. The molecular weight distribution was determined by size exclusion chromatography (HPSEC). Thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC) techniques were used to determine the mass loss due to the high temperature treatment. The lignins studied showed the presence of p-hydroxyphenyl (H unit) and a greater proportion of guaiacyl (G unit) moieties, lower purity, similar or greater amount of phenolic hydroxyl groups, and higher degradation temperatures, than the Alcell (R) lignin.
Resumo:
Ceriporiopsis subvermispora is a white-rot fungus used in biopulping processes and seems to use the fatty acid peroxidation reactions initiated by manganese-peroxidase (MnP) to start lignin degradation. The present work shows that C. subvermispora was able to peroxidize unsaturated fatty acids during wood biotreatment under biopulping conditions. In vitro assays showed that the extent of linoleic acid peroxidation was positively correlated with the level of MnP recovered from the biotreated wood chips. Milled wood was treated in vitro by partially purified MnP and linoleic acid. UV spectroscopy and size exclusion chromatography (SEC) showed that soluble compounds similar to lignin were released from the milled wood. SEC data showed a broad elution profile compatible with low molar mass lignin fractions. MnP-treated milled wood was analyzed by thioacidolysis. The yield of thioacidolysis monomers recovered from guaiacyl and syringyl units decreased by 33% and 20% in MnP-treated milled wood, respectively. This has suggested that lignin depolymerization reactions have occurred during the MnP/linoleic acid treatment. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
A reversed-phase high performance liquid chromatographic (RP-HPLC) method for determination of econazole nitrate, preservatives (methylparaben and propylparaben) and its main impurities (4-chlorobenzl alcohol and alpha-(2,4-dicholorophenyl)-1H-imidazole-1-ethanol) in cream formulations, has been developed and validated. Separation was achieved on a column Bondclone (R) C18 (300 mm x 3.9 mm i.d., 10 mu m) using a gradient method with mobile phase composed of methanol and water. The flow rate was 1.4 mL min(-1), temperature of the column was 25 C and the detection was made at 220 nm. Miconazole nitrate was used as an internal standard. The total run time was less than 15 min, The analytical curves presented coefficient of correlation upper to 0.99 and detection and quantitation limits were calculated for all molecules. Excellent accuracy and precision were obtained for econazole nitrate. Recoveries varied from 97.9 to 102.3% and intra- and inter-day precisions, calculated as relative standard deviation (R.S.D), were lower than 2.2%. Specificity, robustness and assay for econazole nitrate were also determined. The method allowed the quantitative determination of econazole nitrate, its impurities and preservatives and could be applied as a stability-indicating method for econazole nitrate in cream formulations. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
A simple, fast, inexpensive and reliable capillary zone electrophoresis (CZE) method for the determination of econazole nitrate in cream formulations has been developed and validated. Optimum conditions comprised a pH 2.5 phosphate buffer at 20 mmol L(-1) concentration, +30 kV applied voltage in a 31.5 cm x 50 mu m I.D. capillary. Direct UV detection at 200 nm led to an adequate sensitivity without interference from sample excipients. A single extraction step of the cream sample in hydrochloric acid was performed prior to injection. Imidazole (100 mu g mL(-1)) was used as internal standard. Econazole nitrate migrates in approximately 1.2 min. The analytical curve presented a coefficient of correlation of 0.9995. Detection and quantitation limits were 1.85 and 5.62 mu g mL(-1), respectively. Excellent accuracy and precision were obtained. Recoveries varied from 98.1 to 102.5% and intra- and inter-day precisions, calculated as relative standard deviation (RSD), were better than 2.0%. The proposed CZE method presented advantageous performance characteristics and it can be considered suitable for the quality control of econazole nitrate cream formulations. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
A comparative study of the high energy radiation resistance to formation of radicals in two pairs of polymers is reported. In one pair of polymers the phenyl groups containing the imide rings are separated by an ether linkage and in the other pair they are separated by an hexafluoroisopropylidine group. Two of the polymers contained aromatic amine units linked through an ether linkage and the other two polymers contained a trifluoromethyl biphenyl diamine. The polymers were shown to retain a high level of transparency in the visible region following radiolysis to doses as high as 8 Gy. ESR studies of the resistance to radical formation on radiolysis. at 77 K revealed that the polymers containing ether linkages were more stable than their fluorinated analogues, but all were less stable than Kapton (R). (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
INTRODUCTION & OBJECTIVES: Urothelial tumors of upper urinary tract are ranked among the most common types of cancers worldwide. The current standard therapy to prevent recurrence is intravesical Bacillus Calmetteâ Guerin (BCG) immunotherapy, but it presents several disadvantages such as BCG failure and intolerance. Another way is to use chemotherapy, which is generally better tolerated that BCG. In this case, drugs such as epirubicin, doxorubicin, paclitaxel and gemcitabine are used. Nevertheless, intravesical chemotherapy only prevents recurrence in the short-term. These failings can be partially attributed to the short residence time and low bioavailability of the drug within the upper urinary tract and the cancer cells, resulting in a need for frequent drug instillation. To avoid these problems, biodegradable ureteral stents impregnated by supercritical fluid CO2 (SCF) with each of the four anti-cancer drugs were produced. MATERIAL & METHODS: Four formulations with different concentrations of gelatin and alginate and crosslink agent were tested and bismuth was added to confer radiopaque properties to the stent. The preliminary in vivo validation studies in female domestic pigs was conducted at the University of Minho, Braga, after formal approval by the institutionâ s review board and in accordance with its internal ethical protocol for animal experiments. Paclitaxel, epirubicin, doxorubicin and gemcitabine were impregnated in the stents and the release kinetics was measured in artificial urine solution (AUS) for 9 days by UV spectroscopy in a microplate reader. The anti-tumoral effect of the developed stents in transitional cell carcinoma (TCC) and HUVEC primary cells, used as control, was evaluated. RESULTS: The in vivo validation of this second-generation of ureteral stents performed was herein demonstrated. Biodegradable ureteral stents were placed in the ureters of a female pigs, following the normal surgical procedure. The animals remained asymptomatic, with normal urine flow. The in vitro release study in AUS of the stent impregnated showed a higher release in the first 72h for the four anti-cancer drugs impregnated after this time the plateau was achieved and the stent degraded after 9 days. The direct and indirect contact of the anti-cancer biodegradable stents with the TCC and HUVEC cell lines confirm the anti-tumor effect of the stents impregnated with the four anti-cancer drugs, reducing around 75% of the viability of the TCC cell line after 72h and no killing effect in the HUVEC cells. CONCLUSIONS: The use of biodegradable ureteral stent in urology clinical practice not only reduce the stent-related symptoms but also open new treatment therapyâ s, like in urothelial tumors of upper urinary tract. Furthermore, we have demonstrated the clinical validation in vivo pig model. This study has thus shown the killing efficacy of the anti-cancer drug eluting biodegradable stents in vitro for the TCC cell line, with no toxicity observed in the control, non-cancerous cells.The direct and indirect contact of the anti-cancer biodegradable stents with the TCC and HUVEC cell lines confirm the anti-tumor effect of the stents impregnated with the four anti-cancer drugs, reducing around 75% of the viability of the TCC cell line after 72h and no killing effect in the HUVEC cells. This study has thus shown the killing efficacy of the anti-cancer drug eluting biodegradable stents in vitro for the TCC cell line, with no toxicity observed in the control, non-cancerous cells.