958 resultados para User interfaces


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Information visualization is a process of constructing a visual presentation of abstract quantitative data. The characteristics of visual perception enable humans to recognize patterns, trends and anomalies inherent in the data with little effort in a visual display. Such properties of the data are likely to be missed in a purely text-based presentation. Visualizations are therefore widely used in contemporary business decision support systems. Visual user interfaces called dashboards are tools for reporting the status of a company and its business environment to facilitate business intelligence (BI) and performance management activities. In this study, we examine the research on the principles of human visual perception and information visualization as well as the application of visualization in a business decision support system. A review of current BI software products reveals that the visualizations included in them are often quite ineffective in communicating important information. Based on the principles of visual perception and information visualization, we summarize a set of design guidelines for creating effective visual reporting interfaces.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The increasing use of 3D modeling of Human Face in Face Recognition systems, User Interfaces, Graphics, Gaming and the like has made it an area of active study. Majority of the 3D sensors rely on color coded light projection for 3D estimation. Such systems fail to generate any response in regions covered by Facial Hair (like beard, mustache), and hence generate holes in the model which have to be filled manually later on. We propose the use of wavelet transform based analysis to extract the 3D model of Human Faces from a sinusoidal white light fringe projected image. Our method requires only a single image as input. The method is robust to texture variations on the face due to space-frequency localization property of the wavelet transform. It can generate models to pixel level refinement as the phase is estimated for each pixel by a continuous wavelet transform. In cases of sparse Facial Hair, the shape distortions due to hairs can be filtered out, yielding an estimate for the underlying face. We use a low-pass filtering approach to estimate the face texture from the same image. We demonstrate the method on several Human Faces both with and without Facial Hairs. Unseen views of the face are generated by texture mapping on different rotations of the obtained 3D structure. To the best of our knowledge, this is the first attempt to estimate 3D for Human Faces in presence of Facial hair structures like beard and mustache without generating holes in those areas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

2nd International Conference on Education and New Learning Technologies

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Datuen analisi kuantitatiboa egin behar duen edonork, gaur egun, aukera zabala du. Programa ugari daude, komertzialak zein doakoak, edozein analisi mota, sinpleena zein konplexuena, egiteko. Programa komertzialen artean, SPSS, SAS, STATISTICA, Systat, Stata edo GenStat aipa daitezke. Programa horiek merkatu osoaz jabetu dira, eta Europako eta Amerikako unibertsitateetan analisi-tresna moduan erabiltzen dira. Programa horiek joan dira, lehenengo bertsioetatik gaurkoetaraino, interfaze grafikoak hobetuz (GUI Graphical User Interfaces) eta analisi-eredu gero eta konplexuagoak erantsiz. Leihoen kudeaketan oinarrituriko testuinguru-menuen eta goitik beherako menuen garapenari esker, programak erabilerrazagoak dira, eta analisi zein eredu formal konplexuenekin lan egiteko aukera izan du erabiltzaileen komunitateak.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

[EN]Hyperventilation, which is common both in-hospital and out-of-hospital cardiac arrest, decreases coronary and cerebral perfusion contributing to poorer survival rates in both animals and humans. Current resucitation guidelines recommend continuous monitoring of exhaled carbon dioxide (CO2) during cardiopulmonary resucitation (CPR) and emphasize good quality of CPR, including ventilations at 8-10 min1. Most of commercial monitors/de- brilators incorporate methods to compute the respiratory rate based on capnography since it shows uctuations caused by ventilations. Chest compressions may induce artifacts in this signal making the calculation of the respiratory rate di cult. Nevertheless, the accuracy of these methods during CPR has not been documented yet. The aim of this project is to analyze whether the capnogram is reliable to compute ventilation rate during CPR. A total of 91 episodes, 63 out-of-hospital cardiac arrest episodes ( rst database) and 28 in-hospital cardiac arrest episodes (second database) were used to develop an algorithm to detect ventilations in the capnogram, and the nal aim is to provide an accurate ventilation rate for feedback purposes during CPR. Two graphic user interfaces were developed to make the analysis easier and another two were adapted to carry out this project. The use of this interfaces facilitates the managment of the databases and the calculation of the algorithm accuracy. In the rst database, as gold standard every ventilation was marked by visual inspection of both the impedance, which shows uctuations with every ventilation, and the capnography signal. In the second database, volume of the respiratory ow signal was used as gold standard to mark ventilation instants since it is not a ected by chest compressions. The capnogram was preprocessed to remove high frequency noise, and the rst di erence was computed to de ne the onset of inspiration and expiration. Then, morphological features were extracted and a decission algorithm built based on the extracted features to detect ventilation instants. Finally, ventilation rate was calculated using the detected instants of ventilation. According to the results obtained in this project, the capnogram can be reliably used to give feedback ventilation rate, and therefore, on hyperventilation in a resucitation scenario.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

[EN]In this project has been developed a tool which synthesizes realistic waveforms produced by the intra-aortic balloon pump. In addition the following waveforms have also been synthesized: arterial blood pressure (ABP) waveform, the four variations produced due to timing errors of the balloon and the waveform of the helium gas rapidly shuttling in and out of the balloon chamber. All waveforms are synthesized in synchrony with the balloon's inflation/deflation cycles. A database composed of annotated ECG (Electrocardiogram) normal sinus rhythm records has also been created during the project. In order to facilitate the work, two graphical user interfaces were developed. The first interface allows the selection of the ECG records, which were latter annotated using the second interface. Starting from the newly created annotated database, the different waveforms, mentioned above, were synthesized. In this document, in view of the synthesized waveforms, it can be concluded that the obtained results are satisfactory.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This brief note reviews five papers which were presented at the 1993 IFAC World Congress, on the theme 'standards and guidelines for computer-aided control engineering (CACE)'. This session was organized as part of the CACE Software Standardization Initiative, a combined effort of the IFAC and IEEE Control System Society committees on standards. The motivation of this report is to note the substantial progress that was made in this initiative, and to provide the basis for further discussion and work. The papers under review were concerned with integrated design environments, the use of the EXPRESS language for defining standard data structures, database management, user interfaces, and the modeling and simulation of hybrid systems.