973 resultados para Urine Patches


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper reports a study in the wet tropics of Queensland on the fate of urea applied to a dairy pasture in the absence of grazing animals. A nitrogen balance was conducted in cylindrical plots with N-15-labelled urea, and ammonia volatilisation was determined using a mass balance micrometeorological method. The pasture plants took up 42% of the applied nitrogen in the 98 days between fertiliser application and harvest. At harvest 18% of the applied nitrogen was found in the soil, and 40% was lost from the plant-soil system. The micrometeorological study showed that 20% of the unrecovered nitrogen was lost by ammonia volatilisation. As there was no evidence for leaching or runoff losses it was concluded that the remaining 20% of the applied nitrogen was lost by denitrification. It is evident from these results that fertiliser nitrogen is not being used efficiently on dairy pastures, and that practices need to be changed to conserve fertiliser nitrogen and reduce contamination of the environment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The most common methods of bladder augmentation are gastrocystoplasty and enterocystoplasty. Gastrocystoplasty is advantageous due to minimal mucous secretion and a well developed muscular wall as well as good urodynamic properties of the patch. However, the permanent contact of urine with the gastric mucosa is not free of complications. We report the urodynamic, macroscopic and histological outcomes of a pedicled de-epithelialized gastric patch incorporated in the bladder. We compared the results to those of our previous study, which sought to analyze these techniques of patch coverage using sigmoid patches. MATERIALS AND METHODS: We performed 20 augmentation cystoplasties in the mini-pig model using a pedicled de-epithelialized gastric patch and 5 techniques of patch coverage. RESULTS: Three months after surgery all bladders had an increase in volume except those in which the auto-augmentation technique was used. However, all gastric patches were smaller compared to preoperative size. Many had irregular fibrosed inner surfaces and histological evaluation revealed a fibrosed newly formed submucosal layer with a complete urothelial coverage in every patch. No gastric mucosal remnant was found. CONCLUSIONS: De-epithelialized gastrocystoplasty is an attractive procedure that can increase bladder capacity as well as provide a complete urothelial lining without mucosal remnants. However, the success of this procedure seems to be limited by increased morbidity and fibrotic changes, and decreased surface of the patch.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Enterocystoplasty and gastrocystoplasty have been developed to restore adequate bladder capacity but they still result in the undesired harmful contact of urine with the intestinal mucosa. In an attempt to prevent this nonphysiological interface we performed several modified enterocystoplasties in the mini-pig model using a pedicled, detubularized, de-epithelialized sigmoid patch. Five techniques of patch coverage were used to evaluate urothelial growth or survival on the sigmoid patch. All but 1 patch had intestinal mucosa remnants with mucocele formation. When no coverage was applied or a biodegradable polyglactin mesh was temporarily covering the pedicled, detubularized, de-epithelialized sigmoid patch, severe shrinkage occurred. Partial cover with autologous urothelium islets seemed to decrease shrinkage. Adequate urothelium survival and satisfactory elastic properties of the patch were observed when total cover of the sigmoid patch was achieved with a sheet of homologous urothelium recovering autologous urothelial islets or when the patch was applied to protruding urothelium obtained following sagittal posterior detrusor myotomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Compare parents' reports of youth problems (PRYP) with adolescent problems self-reports (APSR) pre/post behavioral treatment of nocturnal enuresis (NE) based on the use of a urine alarm. MATERIALS AND METHODS: Adolescents (N = 19) with mono-symptomatic (primary or secondary) nocturnal enuresis group treatment for 40 weeks. Discharge criterion was established as 8 weeks with consecutive dry nights. PRYP and APSR were scored by the Child Behavior Checklist (CBCL) and Youth Self-Report (YSR). RESULTS: Pre-treatment data: 1) Higher number of clinical cases based on parent report than on self-report for Internalizing Problems (IP) (13/19 vs. 4/19), Externalizing Problems (EP) (7/19 vs. 5/19) and Total Problem (TP) (11/19 vs. 5/19); 2) Mean PRYP scores for IP (60.8) and TP (61) were within the deviant range (T score ≥ 60); while mean PRYP scores for EP (57.4) and mean APSR scores (IP = 52.4, EP = 49.5, TP = 52.4) were within the normal range. Difference between PRYP' and APSR' scores was significant. Post treatment data: 1) Discharge for majority of the participants (16/19); 2) Reduction in the number of clinical cases on parental evaluation: 9/19 adolescents remained within clinical range for IP, 2/19 for EP, and 7/19 for TP. 3) All post-treatment mean scores were within the normal range; the difference between pre and post evaluation scores was significant for PRYP. CONCLUSIONS: The behavioral treatment based on the use of urine alarm is effective for adolescents with mono-symptomatic (primary and secondary) nocturnal enuresis. The study favors the hypothesis that enuresis is a cause, not a consequence, of other behavioral problems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Early diagnosis of dengue virus (DENV) infection is important for patient management and control of dengue outbreaks. The objective of this study was to analyze the usefulness of urine and saliva samples for early diagnosis of DENV infection by real time RT-PCR. Two febrile patients, who have been attended at the General Hospital of the School of Medicine of Ribeirao Preto, Sao Paulo University were included in the study. Serum, urine and saliva samples collected from both patients were subjected to real time RT-PCR for DENV detection and quantification. Dengue RNA was detected in serum, urine and saliva samples of both patients. Patient 1 was infected with DENV-2 and patient 2 with DENV-3. Data presented in this study suggest that urine and saliva could be used as alternative samples for early diagnosis of dengue virus infection when blood samples are difficult to obtain, e.g.,in newborns and patients with hemorrhagic syndromes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of uric acid in urine shows clinical importance, once it can be related to human organism dysfunctions, such as gout. An analytical procedure employing a multicommuted flow system was developed for the determination of uric acid in urine samples. Cu(II) ions are reduced by uric acid to Cu(I) that can be quantified by spectrophotometry in the presence of 2,2`-biquinoline 4,4`-dicarboxylic acid (BCA). The analytical response was linear between 10 and 100 mu mol L(-1) uric acid with a detection limit of 3.0 mu mol L(-1) (99.7% confidence level). Coefficient of variation of 1.2% and sampling rate of 150 determinations per hour were achieved. Per determination, 32 mu g of CuSO(4) and 200 mu g of BCA were consumed, generating 2.0 mL of waste. Recoveries from 91 to 112% were estimated and the results for 7 urine samples agreed with those obtained by the commercially available enzymatic kit for determination of uric acid. The procedure required 100-fold dilution of urine samples, minimizing sample consumption and interfering effects. In order to avoid the manual dilution step, on-line sample dilution was achieved by a simple system reconfiguration attaining a sampling rate of 95 h(-1). (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This survey evaluated the presence of AFM(1) in human urine samples from a specific Brazilian population, as well as corn, peanut, and milk consumption measured by two types of food inquiry. Urine samples from donors who live in the city of Piracicaba, State of Sao Paulo, Brazil were analyzed to detect the presence of aflatoxin M(1) (AFM(1)). an aflatoxin B(1) metabolite, which may be used as aflatoxin B(1) exposure biomarker. The AFM(1) analysis was performed using immunoaffinity clean-up and detection by high-performance-liquid chromatography with fluorescence detector. A total of 69 samples were analyzed and 45 of them (65%) presented contaminations >= 1.8 pg ml(-1), which was the limit of quantification (LOQ). Seventy eight percent (n = 54) of the samples presented detectable concentrations of AFM(1) (>0.6 pg ml(-1)). The AFM(1) concentration among samples above LOQ ranged from 1.8 to 39.9 pg ml(-1). There were differences in food consumption profile among donors, although no association was found between food consumption and AFM(1) concentration in urine. The high frequency of positive samples suggests exposure of the populations studied to aflatoxins. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paraquat is a broad-spectrum contact herbicide that has been encountered worldwide in several cases of accidental, homicidal, and suicidal poisonings. The pulmonary toxicity of this compound is related to the depletion of NADPH in the pneumocytes, which is continuously consumed by the reduction/oxidation of paraquat and reductase enzyme systems in the presence of O(2) (redox cycling). Based on this mechanism, an enzymatic-spectrophotometric method was developed for the determination of paraquat in urine samples. The velocity of NADPH consumption was monitored at 340 nm, every 10 s during 15 min. The velocity of NADPH oxidation correlated with the paraquat levels found in samples. The enzymatic-spectrophotometric method showed to be sensitive, making possible the detection of paraquat in urine samples at concentrations as low as 0.05 mg/L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel microemulsion electrokinetic capillary chromatography (MEEKC) method has been developed which separates a range of nine steroids. A microemulsion containing ethyl acetate, butan-1-ol, sodium dodecyl sulfate, 15% (v/v) acetonitrile and 12 mmol L(-1) sodium tetraborate aqueous buffer at pH 9.2 was used with direct UV detection at 200 nm. The method was validated for the determination of 17 beta-estradiol content, a hormone steroid, in transdermal patches. Adequate sensitivity (DL = 0.88 mu g mL(-1); QL = 2.65 mu g mL(-1)) without interference from sample excipients was obtained. 17 beta-Estradiol migrates in approximately 5.4 min. Estrone was used as internal standard and acceptable precision (< 1.2% RSD), linearity (r = 0.9996; range from 40.0 to 60.0 mu g mL(-1)), and recovery (100.4 +/- A 0.9% at three concentration levels) were obtained. The principal advantage of the method is that it is rapid and avoids the need of time consuming and expensive sample pre-treatment steps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A selective and reproducible off-line solid-phase microextraction procedure was developed for the simultaneous enantioselective determination of mirtazapine (MRT), demethylmirtazapine and 8-hydroxymirtazapine in human urine. CE was used for optimization of the extraction procedure whereas LC-MS was used for method validation and application. The influence of important factors in the solid-phase microextraction efficiency is discussed, such as the fiber coatings, extraction time, pH, ionic strength, temperature and desorption time. Before extraction, human urine samples were submitted to enzymatic hydrolysis at 37 degrees C for 16 h. Then, the enzyme was precipitated with trichloroacetic acid and the pH was adjusted to 8 with 1 mol/L pH 11 phosphate buffer solution. In the extraction, the analytes were transferred from the aqueous solution to the polydimethylsiloxane-divinylbenzene fiber coating and then desorbed in methanol. The mean recoveries were 5.4, 1.7 and 1.0% for MRT, demethylmirtazapine and 8-hydroxymirtazapine enantiomers, respectively. The method was linear over the concentration range of 62-1250 ng/mL. The within-day and between-day assay precision and accuracy were lower than 15%. The method was successfully employed in a preliminary cumulative urinary excretion study after administration of racemic MRT to a healthy volunteer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An enantioselective high-performance liquid chromatographic method for the analysis of carvedilol in plasma and urine was developed and validated using (-)-menthyl chloroformate (MCF) as a derivatizing reagent. Chloroform was used for extraction, and analysis was performed by HPLC on a C18 column with a fluorescence detector. The quantitation limit was 0.25 ng/ml for S(-)-carvedilol in plasma and 0.5 ng/ml for R(+)-carvedilol in plasma and for both enantiomers in urine. The method was applied to the study of enantioselectivity in the pharmacokinetics of carvedilol administered in a multiple dose regimen (25mg/12h) to a hypertensive elderly female patient. The data obtained demonstrated highest plasma levels for the R(+)-carvedilol(AUCSS 75.64 vs 37.29ng/ml). The enantiomeric ratio R(+)/S(-) was 2.03 for plasma and 1.49 0 - 12 for urine (Aeo-12 17.4 vs 11.7 pg). Copyright (c) 2008 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selenium (Se) is an essential element and deficit or excess of dietary Se is associated with health disorders. Relatively elevated Se levels have been reported in the Brazilian Amazon, where there are also important annual variations in the availability of different foods. The present study was conducted among six riparian communities of the Tapajos River to evaluate seasonal variations in blood and sequential hair cm Se concentrations, and to examine the relationships between Se in blood and hair, and blood and urine. Two cross-sectional studies were conducted, at the descending water (DWS, n = 259) and the rising water (RWS, n = 137) seasons, with repeated measures for a subgroup (n = 112). Blood Se (B-Se), hair Se (H-Se) and urine Se (U-Se) were determined. Match-paired analyses were used for seasonal comparisons and the method of best fit was used to describe the relationships between biomarkers. B-Se levels presented a very large range (142-2447 mu g/l) with no overall seasonal variation (median 284 and 292 mu g/l, respectively). Sequential analysis of 13 cm hair strands showed significant variations over time: Se concentrations at the DWS were significantly lower compared with the rising water season (medians: 0.7 and 0.9 mu g/g; ranges: 0.2-4.3 mu g/g and 0.2-5.4 mu g/g, respectively). At both seasons, the relationships between B-Se and H-Se were linear and highly significant (r(2) = 67.9 and 63.6, respectively), while the relationship between B-Se and U-Se was best described by a sigmoid curve. Gender, age, education and smoking did not influence Se status or biomarker relationships. Variations in H-Se suggest that there may be seasonal availability of Se sources in local food. For populations presenting a large range and/or elevated Se exposure, sequential analyses of H-Se may provide a good reflection of variations in Se status.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the properties of calcium-activated chloride channels in inside-out membrane patches from the dendritic knobs of acutely dissociated rat olfactory receptor neurons. Patches typically contained large calcium-activated currents, with total conductances in the range 30-75 nS. The dose response curve for calcium exhibited an EC50 of about 26 mu M. In symmetrical NaCl solutions, the current-voltage relationship reversed at 0 mV and was linear between -80 and +70 mV. When the intracellular NaCl concentration was progressively reduced from 150 to 25 mM, the reversal potential changed in a manner consistent with a chloride-selective conductance. Indeed, modeling these data with the Goldman-Hodgkin-Katz equation revealed a P-Na/P-Cl of 0.034. The halide permeability sequence was P-Cl > P-F > P-I > P-Br indicating that permeation through the channel was dominated by ion binding sites with a high field strength. The channels were also permeable to the large organic anions, SCN-, acetate(-), and gluconate(-), with the permeability sequence P-Cl > P-SCN > gluconaie. Significant permeation to gluconate ions suggested that the channel pore had a minimum diameter of at least 5.8 Angstrom.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A hydride cold-trapping technique was developed and optimised for the measurement of urinary arsenic metabolites. The analytical precision of the method was found to be 6.1, 4.0 and 4.8% (n = 5) for inorganic arsenic (As-i), monomethylarsonate (MMA) and dimethylarsinate (DMA), respectively, with recoveries close to 100%, The detection limits were 1.0, 1.3 and 3 ng for As-i, MMA and DMA, respectively. The method was then used to analyse urine samples obtained from three groups of workers for occupational exposure in three companies where copper chrome arsenate was used for timber treatment. The results were compared with those for a normal control group of laboratory workers. Arsenic and its metabolites were also measured in experimental rats given 5 mg As kg(-1) body mass by oral gavage in the form of sodium arsenite, calcium arsenite or sodium arsenate. Occupational workers showed a significantly higher excretion of As-i, Up to two fold increases of urinary As-i excretion in rats compared with control rats were also observed in animals dosed with various forms of arsenicals. The method is suitable for the measurement of arsenic metabolites in urine of both humans and experimental animals.