998 resultados para Urine Color


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FMVZ

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Visual inspection of a patient's urine has long been used by physicians, with colour recognised as having important clinical implications. In this review the authors will revisit this ancient pastime with relevance to contemporary medical practice.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Context: Accurately determining hydration status is a preventative measure for exertional heat illnesses (EHI). Objective: To determine the validity of various field measures of urine specific gravity (Usg) compared to laboratory instruments. Design: Observational research design to compare measures of hydration status: urine reagent strips (URS) and a urine color (Ucol) chart to a refractometer. Setting: We utilized the athletic training room of a Division I-A collegiate American football team. Participants: Trial 1 involved urine samples of 69 veteran football players (age=20.1+1.2yr; body mass=229.7+44.4lb; height=72.2+2.1in). Trial 2 involved samples from 5 football players (age=20.4+0.5yr; body mass=261.4+39.2lb; height=72.3+2.3in). Interventions: We administered the Heat Illness Index Score (HIIS) Risk Assessment, to identify athletes at-risk for EHI (Trial 1). For individuals “at-risk” (Trial 2), we collected urine samples before and after 15 days of pre-season “two-a-day” practices in a hot, humid environment(mean on-field WBGT=28.84+2.36oC). Main Outcome Measures: Urine samples were immediately analyzed for Usg using a refractometer, Diascreen 7® (URS1), Multistix® (URS2), and Chemstrip10® (URS3). Ucol was measured using Ucol chart. We calculated descriptive statistics for all main measures; Pearson correlations to assess relationships between the refractometer, each URS, and Ucol, and transformed Ucol data to Z-scores for comparison to the refractometer. Results: In Trial 1, we found a moderate relationship (r=0.491, p<.01) between URS1 (1.020+0.006μg) and the refractometer (1.026+0.010μg). In Trial 2, we found marked relationships for Ucol (5.6+1.6shades, r=0.619, p<0.01), URS2 (1.019+0.008μg, r=0.712, p<0.01), and URS3 (1.022+0.007μg, r=0.689, p<0.01) compared to the refractometer (1.028+0.008μg). Conclusions: Our findings suggest that URS were inconsistent between manufacturers, suggesting practitioners use the clinical refractometer to accurately determine Usg and monitor hydration status.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Quantitative Ureaplasma urealyticum culture was performed on clean first-void and midstream urine to evaluate the presence of these mollicutes in the urinary tract. The results, expressed as color changing units (CCU), showed that 14 (63%) of the 22 Ureaplasma urealyticum positive patients yielded counts equal to or higher that 10(7) CCU/mL for both the initial and the middle urine specimens. No abnormal chemical or microscopic findings (protein content, leukocyte numbers) were observed. The occurrence of U. urealyticum in midstream urine samples, even when numbers are considered, may be no more than a guide to the presence of ureaplasmas in the urinary tract.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A kinetic spectrophotometric method with aid of chemometrics is proposed for the simultaneous determination of norfloxacin and rifampicin in mixtures. The proposed method was applied for the simultaneous determination of these two compounds in pharmaceutical formulation and human urine samples, and the results obtained are similar to those obtained by high performance liquid chromatography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine (a) the effect of different sunglass tint colorations on traffic signal detection and recognition for color normal and color deficient observers, and (b) the adequacy of coloration requirements in current sunglass standards. Methods: Twenty color-normals and 49 color-deficient males performed a tracking task while wearing sunglasses of different colorations (clear, gray, green, yellow-green, yellow-brown, red-brown). At random intervals, simulated traffic light signals were presented against a white background at 5° to the right or left and observers were instructed to identify signal color (red/yellow/green) by pressing a response button as quickly as possible; response times and response errors were recorded. Results: Signal color and sunglass tint had significant effects on response times and error rates (p < 0.05), with significant between-color group differences and interaction effects. Response times for color deficient people were considerably slower than color normals for both red and yellow signals for all sunglass tints, but for green signals they were only noticeably slower with the green and yellow-green lenses. For most of the color deficient groups, there were recognition errors for yellow signals combined with the yellow-green and green tints. In addition, deuteranopes had problems for red signals combined with red-brown and yellow-brown tints, and protanopes had problems for green signals combined with the green tint and for red signals combined with the red-brown tint. Conclusions: Many sunglass tints currently permitted for drivers and riders cause a measurable decrement in the ability of color deficient observers to detect and recognize traffic signals. In general, combinations of signals and sunglasses of similar colors are of particular concern. This is prima facie evidence of a risk in the use of these tints for driving and cautions against the relaxation of coloration limits in sunglasses beyond those represented in the study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated influences of optics and surround area on color appearance of defocused, small narrow band photopic lights (1’ arc diameter, λmax 510 - 628 nm) centered within a black annulus and surrounded by a white field. Participants included seven normal trichromats with L- or M-cone biased ratios. We controlled chromatic aberration with elements of a Powell achromatizing lens and corrected higher-order aberrations with an adaptive-optics system. Longitudinal chromatic aberrations, but not monochromatic aberrations, are involved in changing appearance of small lights with defocus. Surround field structure is important because color changes were not observed when lights were presented on a uniform white surround.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A good object representation or object descriptor is one of the key issues in object based image analysis. To effectively fuse color and texture as a unified descriptor at object level, this paper presents a novel method for feature fusion. Color histogram and the uniform local binary patterns are extracted from arbitrary-shaped image-objects, and kernel principal component analysis (kernel PCA) is employed to find nonlinear relationships of the extracted color and texture features. The maximum likelihood approach is used to estimate the intrinsic dimensionality, which is then used as a criterion for automatic selection of optimal feature set from the fused feature. The proposed method is evaluated using SVM as the benchmark classifier and is applied to object-based vegetation species classification using high spatial resolution aerial imagery. Experimental results demonstrate that great improvement can be achieved by using proposed feature fusion method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biomarker analysis has been implemented in sports research in an attempt to monitor the effects of exertion and fatigue in athletes. This study proposed that while such biomarkers may be useful for monitoring injury risk in workers, proteomic approaches might also be utilised to identify novel exertion or injury markers. We found that urinary urea and cortisol levels were significantly elevated in mining workers following a 12 hour overnight shift. These levels failed to return to baseline over 24h in the more active maintenance crew compared to truck drivers (operators) suggesting a lack of recovery between shifts. Use of a SELDI-TOF MS approach to detect novel exertion or injury markers revealed a spectral feature which was associated with workers in both work categories who were engaged in higher levels of physical activity. This feature was identified as the LG3 peptide, a C-terminal fragment of the anti-angiogenic / anti-tumourigenic protein endorepellin. This finding suggests that urinary LG3 peptide may be a biomarker of physical activity. It is also possible that the activity mediated release of LG3 / endorepellin into the circulation may represent a biological mechanism for the known inverse association between physical activity and cancer risk / survival.