979 resultados para Unstable shoes
Resumo:
The purpose of this study was to compare kinematics and kinetics during walking for healthy subjects using unstable shoes with different designs. Ten subjects participated in this study, and foot biomechanical data during walking were quantified using motion analysis system and a force plate. Data were collected for unstable shoes condition after accommodation period of one week. With soft material added in the heel region, the peak impact force was effectively reduced when compared among similar shapes. In addition, the soft material added in the rocker bottom showed more to be in dorsiflexed position during the initial stance. The shoe with three rocker curves design reduced the contact area in the heel strike, which may result in increasing human body forward speed. Further studies shall be carried out after adapting to long periods of wearing unstable shoes.
Resumo:
This study explored the effects of unstable shoe design on oxygen consumption. Methods. Oxygen consumption (VO2) and heart rate (HR) were measured in 16 individuals while barefoot, wearing unstable shoes (Masai Barefoot Technology) and wearing conventional sport shoes while standing and walking on a treadmill and for 5 individuals while walking around a 400 m track. Results. When wearing the MBT shoes, a significant (p < 0.01) increase of 9.3 ± 5.2% in VO2 was measured while standing quietly for 6 min. No differences in VO2 and HR were observed between the MBT shoes or weight-adjusted conventional shoes (to match the weight of the MBT shoes) while walking on a treadmill. However, significant increases (p < 0.01) in VO2 (4.4 ± 8.2%) and HR (3.6 ± 7.3%) were observed for the MBT shoes compared with being barefoot. No significant differences in VO2 and HR were recorded while walking around a 400 m track either with MBT shoes, weight-adjusted conventional shoes or barefoot. Nonetheless, a comparison of the MBT shoes with barefoot revealed a tendency for VO2 to be higher when wearing the MBT shoes (7.1 ± 6.5%, p < 0.1) although HR was not significantly affected. Conclusions. The unstable shoe design predominantly effects oxygen consumption while standing, most likely due to increased muscle activity of the lower extremities.
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Unstable shoes have been designed to promote "natural instability" and during walking they should simulate barefoot gait, enhancing muscle activity and, thus, attributing an advantage over regular tennis shoes. Recent studies showed that, after special training on the appropriate walking pattern, the use of the Masai Barefoot Technology (MBT) shoe increases muscle activation during walking. Our study presents a comparison of muscle activity as well as horizontal and vertical forces during gait with the MBT, a standard tennis shoe and barefoot walking of healthy individuals without previous training. These variables were compared in 25 female subjects and gait conditions were compared using ANOVA repeated measures (effect size:0.25). Walking with the MBT shoe in this non-instructed condition produced higher vertical forces (first vertical peak and weight acceptance rate) than walking with a standard shoe or walking barefoot, which suggests an increase in the loads received by the musculoskeletal system, especially at heel strike. Walking with the MBT shoe did not increase muscle activity when compared to walking with the standard shoe. The barefoot condition was more effective than the MBT shoe at enhancing muscle activation. Therefore, in healthy individuals, no advantage was found in using the MBT over a standard tennis shoe without a special training period. Further studies using the MBT without any instruction over a longer period are needed to evaluate if the higher loads observed in the present study would return to their baseline values after a period of adaptation, and if the muscle activity would increase over time. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Calcium oxalate (CaOX) is the most intractable scale component to remove in sugar mill evaporators by either mechanical or chemical means. The operating conditions of sugar mill evaporators should preferentially favour the formation of the thermodynamically stable calcium oxalate monohydrate (COM), yet analysis of scale deposit from different sugar factories have shown that calcium oxalate dihydrate (COD) is usually the predominant phase, and in some cases is the only hydrate formed. The effects of trans-aconitic, succinic and acetic acids, all of which are present in sugarcane juice, and ethylenediamine tetraacetic acid disodium salt (EDTA) on the growth of CaOX crystals have been examined by scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray powder diffraction (XRD) and thermogravimetric analysis (TGA). trans-Aconitic acid, which constitutes two-thirds of the organic acid component in sugarcane juice, in the presence of sugar resulted in the formation of COD and COM in a 3:1 ratio. EDTA was the most effective acid to promote the formation of COD followed by trans-aconitic acid, then acetic acid and lastly succinic acid.
Resumo:
Metrics such as passengers per square metre have been developed to define optimum or crowded rail passenger density. Whilst such metrics are important to operational procedures, service evaluation and reporting, they fail to fully capture and convey the ways in which passengers experience crowded situations. This paper reports findings from a two year study of rail passenger crowding in five Australian capital cities which involved a novel mixed-methodology including ethnography, focus groups and an online stated preference choice experiment. The resulting data address the following four fundamental research questions: 1) to what extent are Australian rail passengers concerned by crowding, 2) what conditions exacerbate feelings of crowdedness, 3) what conditions mitigate feelings of crowdedness, and 4) how can we usefully understand passengers’ experiences of crowdedness? It concludes with some observations on the significance and implications of these findings for customer service provision. The findings outlined in this paper demonstrate that the experience of crowdedness (including its tolerance) cannot be understood in isolation from other customer services issues such as interior design, quality of environment, safety and public health concerns. It is hypothesised that tolerance of crowding will increase alongside improvements to overall customer service. This was the first comprehensive study of crowding in the Australian rail industry.
Resumo:
To describe barefoot, shod and in-shoe kinematics during stance phase of walking gait in a normal arched adult population. An equal sample of males and females (n = 24) was recruited. In order to quantify the effect of footwear independent of technical design features, an ASICS shoe (Onitsuka Tiger-Mexico 66, Japan) was used in this study. Markers were applied to three conditions; barefoot, shod, and in-shoe. The calibration markers were used to define static pose. The order of testing was randomised. Participants completed five trials in each condition. Kinematic data were captured using a 12 camera VICON MX40 motion capture system at 100 Hz and processed in Visual3D. A previously developed model was used to describe joint angles [1]. A univariate two-way ANOVA was used to identify any differences between the pairs of conditions. Post-hoc Sheffé tests were used to further interrogate the data for differences. At peak hallux dorsiflexion (Figure 1), during propulsion, the metatarsophalangeal joint (MPTJ) was significantly more dorsiflexed in the barefoot condition compared to the shod condition (p = 0.004). At the same gait event, the tibiocalcaneal joint (TCJ) was significantly more plantarflexed than both the shod and in-shoe conditions (p < 0.001), and the tarsometatarsal joint (TMTJ) was significantly less dorsiflexed in the barefoot condition compared to the shod and in-shoe conditions (p < 0.001). The findings of the current study demonstrate that footwear has significant effects on sagittal plane MPTJ joint dorsiflexion at peak hallux dorsiflexion, which results in compensations at proximal foot joints.
Resumo:
The aim of this study was to assess the accuracy of placement of pelvic binders and to determine whether circumferential compression at the level of the greater trochanters is the best method of reducing a symphyseal diastasis. Patients were identified by a retrospective review of all pelvic radiographs performed at a military hospital over a period of 30 months. We analysed any pelvic radiograph on which the buckle of the pelvic binder was clearly visible. The patients were divided into groups according to the position of the buckle in relation to the greater trochanters: high, trochanteric or low. Reduction of the symphyseal diastasis was measured in a subgroup of patients with an open-book fracture, which consisted of an injury to the symphysis and disruption of the posterior pelvic arch (AO/OTA 61-B/C). We identified 172 radiographs with a visible pelvic binder. Five cases were excluded due to inadequate radiographs. In 83 (50%) the binder was positioned at the level of the greater trochanters. A high position was the most common site of inaccurate placement, occurring in 65 (39%). Seventeen patients were identified as a subgroup to assess the effect of the position of the binder on reduction of the diastasis. The mean gap was 2.8 times greater (mean difference 22 mm) in the high group compared with the trochanteric group (p < 0.01). Application of a pelvic binder above the level of the greater trochanters is common and is an inadequate method of reducing pelvic fractures and is likely to delay cardiovascular recovery in these seriously injured patients.
Resumo:
Background: Footwear remains a prime candidate for the prevention and rehabilitation of Achilles tendinopathy as it is thought to decrease tension in the tendon through elevation of the heel. However, evidence for this effect is equivocal. Purpose: This study used an acoustic transmission technique to investigate the effect of running shoes on Achilles tendon loading during barefoot and shod walking. Methods: Acoustic velocity was measured in the Achilles tendon of twelve recreationally–active males (age, 31±9 years; height, 1.78±0.06 m; weight, 81.0±16.9 kg) during barefoot and shod walking at matched self–selected speed (3.4±0.7 km/h). Standard running shoes incorporating a 10– mm heel offset were used. Vertical ground reaction force and spatiotemporal parameters were determined with an instrumented treadmill. Axial acoustic velocity in the Achilles tendon was measured using a custom built ultrasonic device. All data were acquired at a rate of 100 Hz during 10s of steady–state walking. Statistical comparisons between barefoot and shod conditions were made using paired t–tests and repeated measure ANOVAs. Results: Acoustic velocity in the Achilles tendon was highly reproducible and was typified by two maxima (P1, P2) and minima (M1, M2) during walking. Footwear resulted in a significant increase in step length, stance duration and peak vertical ground reaction force compared to barefoot walking. Peak acoustic velocity in the Achilles tendon (P1, P2) was significantly higher with running shoes. Conclusions: Peak acoustic velocity in the Achilles tendon was higher with footwear, suggesting that standard running shoes with a 10–mm heel offset increase tensile load in the Achilles tendon. Although further research is required, these findings question the therapeutic role of standard running shoes in Achilles tendinopathy.