51 resultados para Ultrasounds
Resumo:
The World Health Organization (WHO) criteria for the diagnosis of osteoporosis are mainly applicable for dual X-ray absorptiometry (DXA) measurements at the spine and hip levels. There is a growing demand for cheaper devices, free of ionizing radiation such as promising quantitative ultrasound (QUS). In common with many other countries, QUS measurements are increasingly used in Switzerland without adequate clinical guidelines. The T-score approach developed for DXA cannot be applied to QUS, although well-conducted prospective studies have shown that ultrasound could be a valuable predictor of fracture risk. As a consequence, an expert committee named the Swiss Quality Assurance Project (SQAP, for which the main mission is the establishment of quality assurance procedures for DXA and QUS in Switzerland) was mandated by the Swiss Association Against Osteoporosis (ASCO) in 2000 to propose operational clinical recommendations for the use of QUS in the management of osteoporosis for two QUS devices sold in Switzerland. Device-specific weighted "T-score" based on the risk of osteoporotic hip fractures as well as on the prediction of DXA osteoporosis at the hip, according to the WHO definition of osteoporosis, were calculated for the Achilles (Lunar, General Electric, Madison, Wis.) and Sahara (Hologic, Waltham, Mass.) ultrasound devices. Several studies (totaling a few thousand subjects) were used to calculate age-adjusted odd ratios (OR) and area under the receiver operating curve (AUC) for the prediction of osteoporotic fracture (taking into account a weighting score depending on the design of the study involved in the calculation). The ORs were 2.4 (1.9-3.2) and AUC 0.72 (0.66-0.77), respectively, for the Achilles, and 2.3 (1.7-3.1) and 0.75 (0.68-0.82), respectively, for the Sahara device. To translate risk estimates into thresholds for clinical application, 90% sensitivity was used to define low fracture and low osteoporosis risk, and a specificity of 80% was used to define subjects as being at high risk of fracture or having osteoporosis at the hip. From the combination of the fracture model with the hip DXA osteoporotic model, we found a T-score threshold of -1.2 and -2.5 for the stiffness (Achilles) determining, respectively, the low- and high-risk subjects. Similarly, we found a T-score at -1.0 and -2.2 for the QUI index (Sahara). Then a screening strategy combining QUS, DXA, and clinical factors for the identification of women needing treatment was proposed. The application of this approach will help to minimize the inappropriate use of QUS from which the whole field currently suffers.
Resumo:
Bone ultrasound measures (QUSs) can assess fracture risk in the elderly. We compared three QUSs and their association with nonvertebral fracture history in 7562 Swiss women 70-80 years of age. The association between nonvertebral fracture was higher for heel than phalangeal QUS. INTRODUCTION: Because of the high morbidity and mortality associated with osteoporotic fractures, it is essential to detect subjects at risk for such fractures with screening methods. Because quantitative bone ultrasound (QUS) discriminated subjects with osteoporotic fractures from controls in several cross-sectional studies and predicted fractures in prospective studies, QUS could be more practical than DXA for screening. MATERIAL AND METHODS: This cross-sectional and retrospective multicenter (10 centers) study was performed to compare three QUSs (two heel ultrasounds: Achilles+ [GE-Lunar] and Sahara [Hologic]; the phalanges: ultrasound DBM sonic 1200 [IGEA]) for determining by logistic regression nonvertebral fracture odds ratio (OR) in a sample of 7562 Swiss women, 75.3 +/- 3.1 years of age. The two heel QUSs measured the broadband ultrasound attenuation (BUA) and the speed of sound (SOS). In addition, Achilles+ calculated the stiffness index (SI) and the Sahara calculated the quantitative ultrasound index (QUI) from BUA and SOS. The DBM sonic 1200 measured the amplitude-dependent SOS (AD-SOS). RESULTS: Eighty-six women had a history of a traumatic hip fracture after the age of 50, 1594 had a history of forearm fracture, and 2016 had other nonvertebral fractures. No fracture history was reported by 3866 women. Discrimination for hip fracture was higher than for the other nonvertebral fractures. The two heel QUSs had a significantly higher discrimination power than the QUSs of the phalanges, with standardized ORs, adjusted for age and body mass index, ranging from 2.1 to 2.7 (95% CI = 1.6, 3.5) compared with 1.4 (95% CI = 1.1, 1.7) for the AD-SOS of DBM sonic 1200. CONCLUSION: This study showed a high association between heel QUS and hip fracture history in elderly Swiss women. This could justify integration of QUS among screening strategies for identifying elderly women at risk for osteoporotic fractures.
Resumo:
Background: Piezoelectric instrumentation seems to offer 3 important advantages for cutting bone structures. Be more precise because it is produced by micro-vibrations from the cutting insert. Be safer because the ultrasonic frequency used does not affect soft tissue. Thirdly, the less invasive cutting action produces minor tissue damage and consequently probably a better healing Aim of the Study: The aim of this study is to evaluate the effectiveness of piezoelectric device capability in maxillo-facial surgery, in order to take advantage of these favourable capacity. Material and Methods: Considering the several potential application of the piezoelectric technology in Orthognathic, Oncologic and Extractive surgery, we would like to design protocols in order to verify how this new device can modify the surgical technique, the surgical time, the patients healing and its quality of life. Results: Due to the precise Piezosurgery cut, we can manage the Cad-Cam-Custom Made plates protocol in Oncologic Surgery and in Orthognatic Surgery increasing our percentage of comparison between the 3D preoperative plan and the surgical execution. We also found a better quality of life impaction in Patient who underwent and extractive surgery Conclusion: Piezosurgery device seems to be a strong surgical aid were safe and precise cut are needed and its capability to reduce the discomfort Patients need to be study in deep also in major surgery like Orthognatic and Oncologic surgery.
Resumo:
Bone ultrasound measures (QUSs) can assess fracture risk in the elderly. We compared three QUSs and their association with nonvertebral fracture history in 7562 Swiss women 70-80 years of age. The association between nonvertebral fracture was higher for heel than phalangeal QUS.
Resumo:
Because of the important morbidity and mortality associated with osteoporosis, it is essential to detect subjects at risk by screening methods, such as bone quantitative ultrasounds (QUSs). Several studies showed that QUS could predict fractures. None, however, compared prospectively different QUS devices, and few data of quality controls (QCs) have been published. The Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture Risk is a prospective multicenter study that compared three QUSs for the assessment of hip fracture risk in a population of 7609 women age >/=70 yr. Because the inclusion phase lasted 20 mo, and because 10 centers participated in this study, QC became a major issue. We therefore developed a QC procedure to assess the stability and precision of the devices, and for their cross-calibration. Our study focuses on the two heel QUSs. The water bath system (Achilles+) had a higher precision than the dry system (Sahara). The QC results were highly dependent on temperature. QUS stability was acceptable, but Sahara must be calibrated regularly. A sufficient homogeneity among all the Sahara devices could be demonstrated, whereas significant differences were found among the Achilles+ devices. For speed of sound, 52% of the differences among the Achilles+ was explained by the water s temperature. However, for broadband ultrasound attenuation, a maximal difference of 23% persisted after adjustment for temperature. Because such differences could influence measurements in vivo, it is crucial to develop standardized phantoms to be used in prospective multicenter studies.
Resumo:
Introduction. Breast phyllodes tumors (PT) are uncommon fibroepithelial lesions having potential malignant features. These tumors have characteristic features, like phleomorphism, mitoses and overgrowth of the stroma with possible infiltrative margins. The clinical behaviour could be unpredictable, since the relatively high recurrence rate despite correct surgical strategy. Conventional diagnostic examinations show high sensitivity and specificity, but cannot demonstrate the differences between benign and malignant PT. MRI is not more effective. Patients and methods. Sixteen patients affected by PT have been surgically treated at our Institution. All patients received mammography and ultrasonography (US) as preoperative diagnostic work-up. Results. in 13 patients, US was effective in preoperative diagnosis of PT. Mammography was uneffective in detecting breast lesions in 5 cases, while in 11 cases mammographic findings presented benign features, with a round opacity with moderate tissue density and well-defined wall. Conclusion. US remains the most useful diagnostic test in detecting PT. However, there is no test effective in identifying malignat PT. In case of suspicion, fine needle biopsy should be performed.
Resumo:
A utilização da madeira enquanto material estrutural é um aspeto abordado com algum receio ou até desconhecimento por parte dos elementos intervenientes no processo de construção civil, sendo ainda uma área pouco lecionada e muitas vezes excluída dos planos curriculares em Engenharia Civil. Assim sendo é importante o surgimento de trabalhos relacionados com esta matéria, relembrando ao sector da construção civil e ao ramo de estudo relacionado, que a madeira já teve e possivelmente voltará a ter um papel importante a desempenhar na área da construção. Um dos aspetos evidenciados nos estudos realizados consiste na importância da reabilitação de edifícios e do seu papel cada vez mais determinante na sociedade. Esta metodologia de intervenção apresenta-se muitas vezes como uma vantagem económica assim como contribui para a preservação do património arquitetónico e cultural, cujo valor histórico é incalculável. A importância da reabilitação de edifícios habitacionais nas zonas históricas, bem como de monumentos de grande importância cultural apresenta-se cada vez mais como um desafio devido à falta de conservação dos mesmos ao longo da sua vida útil, e da necessidade de preservar a identidade do local, beneficiando assim a qualidade do tecido urbano. Assim sendo, este trabalho apresenta um levantamento dos danos possíveis de ocorrer em elementos de madeira, dando especial destaque aos agentes patológicos e às consequências da sua atividade na madeira assim como às metodologias de inspeção e diagnóstico que poderão ser aplicadas em estruturas de madeira existentes, favorecendo assim a vertente da reabilitação ao invés da demolição. Estas metodologias recorrem a ensaios não destrutivos, como é exemplo o Pilodyn, o Resistógrafo, o Ultra-sons, etc., referindo também o recurso a ensaios destrutivos, cuja utilização terá de ser uma questão muito bem ponderada devido às consequências que implica. Por fim, apresenta-se um caso real de estudo em que se analisa um pavimento em madeira através da aplicação de metodologias de ensaio não destrutivas e destrutivas a amostras recolhidas. O objetivo será determinar o estado de conservação da madeira e algumas características físicas tais como a sua densidade e os módulos de elasticidade, sendo posteriormente efetuada uma análise estrutural. Os resultados obtidos permitem efetuar uma avaliação qualitativa do estado geral do pavimento sendo as principais conclusões que o pavimento se encontra atacado por parte de insetos xilófagos e apresenta problemas a nível de verificação a estados limite de utilização, deformação e vibração, fator que condiciona a possível utilização do pavimento.
Resumo:
A contínua subida dos preços dos combustíveis fósseis tradicionais aliada à crescente pressão por parte de várias instituições mundiais para uma política “verde” no que diz respeito aos combustíveis, levam a um aumento da procura dos biocombustíveis e é neste contexto que surge o biodiesel como um dos principais intervenientes. O biodiesel pode ser definido como um derivado éster monoalquílico de ácidos gordos de cadeia longa proveniente de fontes renováveis como óleos vegetais ou gorduras animais e que apresenta características semelhantes ao diesel de petróleo, podendo ser utilizado sem qualquer problema em motores de ignição por compressão. Este trabalho apresenta como principal objetivo o estudo da aplicação da tecnologia de ultrassons na produção de biodiesel. Foi utilizado neste trabalho como matéria-prima um óleo doméstico usado. Este óleo foi previamente filtrado sendo depois analisado o seu índice de acidez para avaliar o seu teor em ácidos gordos livres. O valor obtido para o índice de acidez do óleo foi de 1,91 mg KOH/g, um valor relativamente baixo permitindo a sua utilização sem ser necessário um tratamento inicial via esterificação para diminuir a acidez do mesmo. Foram realizados três ensaios de reação independentes, o primeiro recorrendo ao método tradicional de produção de biodiesel através de transesterificação e recorrendo a agitação mecânica e aquecimento, o segundo utilizando uma sonda de ultrassons com a potência de 500 W e um terceiro ensaio de reação utilizando uma sonda de ultrassons de 2000 W. Em todas as reações foi utilizada uma proporção de 1:5 de óleo usado e metanol e 0,5 % (em relação á massa de óleo utilizada) de catalisador metilato de sódio. Todas as alíquotas recolhidas durante os ensaios foram analisadas através de cromatografia gasosa de modo a determinar o conteúdo em ésteres presente em cada uma delas. A reação convencional teve uma duração total de 150 minutos e decorreu a uma temperatura de 65ºC e a agitação constante de 500 rpm. Ao longo da reação foram retiradas alíquotas de cerca de 25 ml, que foram tratadas de imediato e posteriormente analisadas de modo a estudar-se o comportamento da reação ao longo do tempo. A percentagem de ésteres metílicos no biodiesel obtida ao fim de 90 minutos foi de 81,3%. Em seguida realizou-se uma reação utilizando uma sonda de ultrassons de 500 W de potência mergulhada num recipiente reacional devidamente isolado com uma rolha de cortiça de modo a minimizar as perdas de metanol por evaporação. O tempo total de reação foi de 90 minutos e foram-se retirando alíquotas de cerca de 25 ml para acompanhar o desenrolar da reação, tendo-se obtido uma percentagem de ésteres metílicos de 85,9% ao fim dos 90 minutos. Foi realizada por fim um terceiro ensaio de reação utilizando uma sonda de 2000 W com uma duração total de 90 minutos, tendo-se obtido resultados pouco satisfatórios (77,7%), provavelmente devido a algum problema operacional relacionado com a sonda de ultrassons utilizada ou devido a uma geometria do reator pouco eficiente. Os produtos resultantes da reação convencional e da reação utilizando a sonda de ultrassons de 500 W, assim como o óleo utilizado como matéria-prima foram caracterizados em termos de índice de acidez, densidade a 15ºC e viscosidade a 40ºC.
Resumo:
Dissertação de mestrado em Química Medicinal
Resumo:
Programa Doutoral em Engenharia Eletrónica e de Computadores
Resumo:
Dissertação de mestrado em Biofísica e Bionanossistemas
Resumo:
Dissertação de mestrado em Bioengenharia
Resumo:
Introduction: A standardized three-dimensional ultrasonographic (3DUS) protocol is described that allows fetal face reconstruction. Ability to identify cleft lip with 3DUS using this protocol was assessed by operators with minimal 3DUS experience. Material and Methods: 260 stored volumes of fetal face were analyzed using a standardized protocol by operators with different levels of competence in 3DUS. The outcomes studied were: (1) the performance of post-processing 3D face volumes for the detection of facial clefts; (2) the ability of a resident with minimal 3DUS experience to reconstruct the acquired facial volumes, and (3) the time needed to reconstruct each plane to allow proper diagnosis of a cleft. Results: The three orthogonal planes of the fetal face (axial, sagittal and coronal) were adequately reconstructed with similar performance when acquired by a maternal-fetal medicine specialist or by residents with minimal experience (72 vs. 76%, p = 0.629). The learning curve for manipulation of 3DUS volumes of the fetal face corresponds to 30 cases and is independent of the operator's level of experience. Discussion: The learning curve for the standardized protocol we describe is short, even for inexperienced sonographers. This technique might decrease the length of anatomy ultrasounds and improve the ability to visualize fetal face anomalies.