925 resultados para Ultrasound biomicroscopy


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To determine the agreement between observers in estimating the configuration of the human anterior chamber angle (ACA) using ultrasound biomicroscopy (UBM). Methods. Two masked clinicians used UBM images to estimate, in 41 eyes, the configuration of the ACA, especially (1) the position of contact between the peripheral iris and the inside of the eye wall, (2) the angularity of the approach to the ACA, and (3) the curvature of the peripheral iris. Agreement between observers was evaluated by the kappa statistic. Results. Inter-observer agreement in assessing the iris insertion (kappa = 0.79), angular width (Kappa = 0.95), and the peripheral iris curvature (kappa = 0.84) was high. Conclusions. The agreement between observers in evaluating the anterior chamber angle configuration by UBM was excellent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: A peripheral iridotomy (PI) is the treatment of choice for pupillary block. In this study we investigated the effect of enlarging the size of a small PI on the anterior chamber angle in patients with angle closure using ultrasound biomicroscopy (UBM). Patients and Methods: Patients who had been treated with laser peripheral iridotomy for angle closure and were identified to have a small patent PI (<100 µm) with still appositionally closed anterior chamber angle were selected prospectively. The anterior chamber angle was assessed using UBM. The angle opening distance 500 µm from the scleral spur (AOD500) as well as the anterior and posterior chamber depth (ACD and PCD) 1000 µm from the scleral spur was measured. In addition, the ACD/PCD ratio was calculated. Afterwards, the PI was enlarged using an Nd: YAG laser and the UBM measurements were repeated as described above. Results: Six eyes of six patients were examined. After the enlargement of the PI the average AOD500 increased from 109 µm (±36) to 147 µm (±40) (p

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To evaluate agreement between clinical examination (slit lamp examination and gonioscopy) and ultrasound biomicroscopy (UBM) in characterizing various features of the anterior chamber angle and adjacent structures. Methods. Twenty-eight patients (51 eyes) with open angle glaucoma (14), closed angle glaucoma (4), narrow angle and/or plateau iris (10), who had undergone UBM between March 94 and September 95 were studied. Evaluated parameters included angle width, iris configuration and presence of angle closure. The UBMs were reviewed in a masked fashion. Results. In 87.8% of cases there was agreement (within 10 degrees) between gonioscopic and UBM estimates of angle width. In all cases with greater than 10 degrees difference (12.2%) the angle size estimated by UBM was less than that estimated clinically. Iris configuration was graded identically in 51% of cases; the majority of disagreements (76.1%) occurred in cases graded as "regular" by gonioscopy and as "steep" by UBM. Angle closure was judged to be present more frequently by UBM. Conclusions. UBM and gonioscopy do not necessarily yield identical values for angle width, iris configuration, and presence of angle closure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate by ultrasound biomicroscopy (UBM) the anatomical characteristics and the intraocular pressure (IOP) lowering mechanisms of deep sclerectomy after long-term follow-up. Methods: In all, 22 eyes of 21 consecutive patients who had deep sclerectomy were examined by UBM. Several UBM variables were prospectively evaluated, including the presence and maximum length and height of the intrascleral space, the minimum thickness of residual trabeculo-Descemet membrane (TDM), the presence and type of subconjunctival filtering bleb, and the presence of other possible drainage sites, for example suprachoroidal. Surgical success was considered to be achieved when the IOP was

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Glaucoma in infants has many causes. Evaluation of the anatomy of the anterior segment of eyes with infantile glaucoma may help to determine the pathogenesis of an infant's disease and influence therapeutic decisions. Methods: Eleven eyes of six infants with glaucoma were evaluated with ultrasound biomicroscopy (UBM) to evaluate the anatomic characteristics and relationships of the anterior segment structures. Results: The anterior chamber angle, iris, lens, ciliary body, and posterior chamber angle could be imaged in detail. Elongated and anteriorly placed ciliary processes were noted in all eight eyes with trabeculodysgenesis. There were no apparent anomalies in the trabecular meshwork, or anterior chamber. In three eyes with dense corneal opacities, ultrasound biomicroscopy showed severe anterior segment disorganization and thin central corneas with posterior corneal excavation. Conclusions: Ultrasound biomicroscopy is a useful non-invasive method for evaluating infants with glaucoma in cases with corneal opacities. This information can help in surgical planning for glaucoma management.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To determine the intra- and interobserver agreement in assessing the configuration of the human anterior chamber angle using ultrasound biomicroscopy (UBM). Methods: Two masked clinicians used ubm images to estimate, in 41 eyes, (a) the position of contact between the peripheral iris and the inside of the eye wall, (b) the angular size of the anterior chamber angle (ACA), and (c) the curvature of the peripheral iris. Both observers, masked to the previous results, examined the same images in a second session. Agreement was evaluated using the unweighted ? statistic. Results: Intraobserver agreement in assessing the iris insertion, angular width, and the iris curvature was high (range of ? values, 0.83-0.92). Interobserver agreement in evaluating the level of iris insertion (? = 0.79), the angular width (? = 0.95), and the iris curvature (? = 0.84) was also high. Conclusion: The agreement within the same observer and between observers in evaluating the ACA configuration by UBM was excellent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With the advent of high frequency transducers, the use of ocular ultrasound has become widely used because it provides definitions of major ocular structures. This diagnostic tool is useful in the evaluation of ophthalmic injuries, and also used for qualitative and quantitative evaluation of intraocular and orbital lesions. It is a noninvasive, safe and fast, easy to use and can be performed in an awake animal. The ocular ultrasonography is indicated in cases of ocular opacity, when the ophthalmic examination cannot be done, and in eyes with ocular trauma or suspected orbital disease. Ultrasound biomicroscopy (UBM) is a diagnostic tool with high cost and sedation or general anesthesia is necessary, but has the advantage of evaluating structures poorly defined or visualized in the anterior segment of the eye. Therefore, this paper aims to show the importance of ocular ultrasonography and UBM to veterinary practitioners, and to demonstrate its advantages and indications in ophthalmic routine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To describe plateau iris syndrome associated with multiple neuroepithelial cysts of the pars plicata. Methods: Case reports of 3 patients with plateau iris syndrome who were found to have multiple bilateral ciliary body cysts on ultrasound biomicroscopic examination. Results: Ultrasound biomicroscopy revealed classic features of plateau iris syndrome in each patient but also showed multiple neuroepithelial cysts of the ciliary body in each eye. Conclusion: Plateau iris syndrome may be associated with multiple ciliary body cysts.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Imaging of the crystalline lens and intraocular lens is becoming increasingly more important to optimize the refractive outcome of cataract surgery, to detect and manage complications and to ascertain advanced intraocular lens performance. This review examines recent advances in anterior segment imaging. RECENT FINDINGS: The main techniques used for imaging the anterior segment are slit-lamp biomicroscopy, ultrasound biomicroscopy, scheimpflug imaging, phakometry, optical coherence tomography and magnetic resonance imaging. They have principally been applied to the assessment of intraocular lens centration, tilt, position relative to the iris and movement with ciliary body contraction. SUMMARY: Despite the advances in anterior chamber imaging technology, there is still the need for a clinical, high-resolution, true anatomical, noninvasive technique to image behind the peripheral iris. © 2007 Lippincott Williams & Wilkins, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non Alcoholic Fatty Liver Disease (NAFLD) is a condition that is frequently seen but seldom investigated. Until recently, NAFLD was considered benign, self-limiting and unworthy of further investigation. This opinion is based on retrospective studies with relatively small numbers and scant follow-up of histology data. (1) The prevalence for adults, in the USA is, 30%, and NAFLD is recognized as a common and increasing form of liver disease in the paediatric population (1). Australian data, from New South Wales, suggests the prevalence of NAFLD in “healthy” 15 year olds as being 10%.(2) Non-alcoholic fatty liver disease is a condition where fat progressively invades the liver parenchyma. The degree of infiltration ranges from simple steatosis (fat only) to steatohepatitis (fat and inflammation) steatohepatitis plus fibrosis (fat, inflammation and fibrosis) to cirrhosis (replacement of liver texture by scarred, fibrotic and non functioning tissue).Non-alcoholic fatty liver is diagnosed by exclusion rather than inclusion. None of the currently available diagnostic techniques -liver biopsy, liver function tests (LFT) or Imaging; ultrasound, Computerised tomography (CT) or Magnetic Resonance Imaging (MRI) are specific for non-alcoholic fatty liver. An association exists between NAFLD, Non Alcoholic Steatosis Hepatitis (NASH) and irreversible liver damage, cirrhosis and hepatoma. However, a more pervasive aspect of NAFLD is the association with Metabolic Syndrome. This Syndrome is categorised by increased insulin resistance (IR) and NAFLD is thought to be the hepatic representation. Those with NAFLD have an increased risk of death (3) and it is an independent predictor of atherosclerosis and cardiovascular disease (1). Liver biopsy is considered the gold standard for diagnosis, (4), and grading and staging, of non-alcoholic fatty liver disease. Fatty-liver is diagnosed when there is macrovesicular steatosis with displacement of the nucleus to the edge of the cell and at least 5% of the hepatocytes are seen to contain fat (4).Steatosis represents fat accumulation in liver tissue without inflammation. However, it is only called non-alcoholic fatty liver disease when alcohol - >20gms-30gms per day (5), has been excluded from the diet. Both non-alcoholic and alcoholic fatty liver are identical on histology. (4).LFT’s are indicative, not diagnostic. They indicate that a condition may be present but they are unable to diagnosis what the condition is. When a patient presents with raised fasting blood glucose, low HDL (high density lipoprotein), and elevated fasting triacylglycerols they are likely to have NAFLD. (6) Of the imaging techniques MRI is the least variable and the most reproducible. With CT scanning liver fat content can be semi quantitatively estimated. With increasing hepatic steatosis, liver attenuation values decrease by 1.6 Hounsfield units for every milligram of triglyceride deposited per gram of liver tissue (7). Ultrasound permits early detection of fatty liver, often in the preclinical stages before symptoms are present and serum alterations occur. Earlier, accurate reporting of this condition will allow appropriate intervention resulting in better patient health outcomes. References 1. Chalasami N. Does fat alone cause significant liver disease: It remains unclear whether simple steatosis is truly benign. American Gastroenterological Association Perspectives, February/March 2008 www.gastro.org/wmspage.cfm?parm1=5097 Viewed 20th October, 2008 2. Booth, M. George, J.Denney-Wilson, E: The population prevalence of adverse concentrations with adiposity of liver tests among Australian adolescents. Journal of Paediatrics and Child Health.2008 November 3. Catalano, D, Trovato, GM, Martines, GF, Randazzo, M, Tonzuso, A. Bright liver, body composition and insulin resistance changes with nutritional intervention: a follow-up study .Liver Int.2008; February 1280-9 4. Choudhury, J, Sanysl, A. Clinical aspects of Fatty Liver Disease. Semin in Liver Dis. 2004:24 (4):349-62 5. Dionysus Study Group. Drinking factors as cofactors of risk for alcohol induced liver change. Gut. 1997; 41 845-50 6. Preiss, D, Sattar, N. Non-alcoholic fatty liver disease: an overview of prevalence, diagnosis, pathogenesis and treatment considerations. Clin Sci.2008; 115 141-50 7. American Gastroenterological Association. Technical review on nonalcoholic fatty liver disease. Gastroenterology.2002; 123: 1705-25

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Preterm infants have an increased risk of low bone mass and subsequent fracture due to limited bone mass accretion in utero and a greater need for bone nutrients. The diagnosis of ostepeonia of prematurity remains difficult as there is no sctreening test which is both sensitive and specific.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two different methods to measure binocular longitudinal corneal apex movements were synchronously applied. High-speed videokeratoscopy at a sampling frequency of 15 Hz and a customdesigned ultrasound distance sensor at 100 Hz were used for the left and the right eye, respectively. Four healthy subjects participated in the study. Simultaneously, cardiac electric cycle (ECG) was registered for each subject at 100 Hz. Each measurement took 20 s. Subjects were asked to suppress blinking during the measurements. A rigid headrest and a bite-bar were used to minimize undesirable head movements. Time, frequency and time-frequency representations of the acquired signals were obtained to establish their temporal and spectral contents. Coherence analysis was used to estimate the correlation between the measured signals. The results showed close correlation between both corneal apex movements and the cardiopulmonary system. Unraveling these relationships could lead to better understanding of interactions between ocular biomechanics and vision. The advantages and disadvantages of the two methods in the context of measuring longitudinal movements of the corneal apex are outlined.