998 resultados para Ultrasonic therapy


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: This crossover study compared the efficacy of an ultrasonic toothbrush for the reduction of plaque, gingival inflammation, and levels of Streptococcus mutans, in relation to an electric and a manual toothbrush. Materials and Methods: Twenty-one patients with orthodontic appliances were divided into three groups. All patients were evaluated by a periodontist and samples of saliva were collected for quantification of S mutans. The patients received their first brushes with appropriate instructions. For each crossover leg, patients used each toothbrush for a period of 30 days. At the end of each washout period, participants received a periodontal evaluation and new samples of saliva were collected. After 15 days of using their own toothbrushes, patients received the next toothbrushes in the experimental sequence. Results: The ultrasonic brush group presented significant improvement in the reduction of visible plaque on the buccal surfaces (-6.36%, P = .007). The counts of S mutans decreased in the electric (2.04 × 105 to 1.36 × 105 colony-forming units [CFU]/mL) and ultrasonic (2.98 × 105 to 1.84 × 105 CFU/mL) groups. There were no statistical differences among the three brushes for the clinical and microbiological parameters evaluated. Conclusions: This study did not demonstrate that the ultrasonic toothbrush was better in reducing gingival inflammation in adolescent orthodontic patients, but plaque scores were lowered on buccal surfaces of teeth with orthodontic brackets. In addition, S mutans counts were markedly decreased in the electric and ultrasonic groups, which should be related to a reduced risk of oral disease. © 2006 by The EH Angle Education and Research Foundation, Inc.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: This review of the literature intends to evaluate the effect of brushes with high frequency motion when compared with manual toothbrushes regarding the indices of plaque and gingival bleeding. METHODS: Patients presenting gingivitis and/or chronic periodontitis were evaluated in addition to patients having osseointegrated implants and fixed orthodontic appliances. Pertinent literature was reviewed to select articles according to previously defined inclusion criteria. RESULTS: In the assessed studies results showed significant decreases in plaque and gingival indices by utilization of both types of brushes. However, in the selected studies where sonic brushes were tested in orthodontic and dental implant patients there was a more significant decrease in the indices. Furthermore, there was no indication of gingival recession attributed to product use. CONCLUSION: Future studies with a more homogeneous methodology and better experiment designs will be needed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Several studies have reported the benefits of sonic and/or ultrasonic instrumentation for root debridement, with most of them focusing on changes in periodontal clinical parameters. The present study investigated possible alterations in the tensile bond strength of crowns cemented with zinc phosphate cement to natural teeth after ultrasonic instrumentation. Forty recently extracted intact human third molars were selected, cleaned and stored in physiologic serum at 4°C. They received standard preparations, at a 16° convergence angle, and AgPd alloy crowns. The crowns were cemented with zinc phosphate cement and then divided into four groups of 10 teeth each. Each group was then subdivided into two subgroups, with one of the subgroups being submitted to 5,000 thermal cycles ranging from 55 ± 2 to 5 ± 2°C, while the other was not. Each group was submitted to ultrasonic instrumentation for different periods of time: group 1 - 0 min (control), group 2 - 5 min, group 3 - 10 min, and group 4 - 15 min. Tensile bond strength tests were performed with an Instron testing machine (model 4310). Statistical analysis was performed using ANOVA and Tukey's test at the 5% level of significance. A significant reduction in the tensile bond strength of crowns cemented with zinc phosphate and submitted to thermal cycles was observed at 15 min (196.75 N versus 0 min = 452.01 N, 5 min = 444.23 N and 10 min = 470.85 N). Thermal cycling and ultrasonic instrumentation for 15 min caused a significant reduction in tensile bond strength (p < .05).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The non-eruption of teeth due to highly keratinized gingival mucosa is a frequent event in the pediatric dentistry, which harms the oral aesthetics and function. A surgical excision of the involved area is indicated, exposing the non-erupted tooth. This procedure involves anesthesia and cutting instruments that may increase the fear and anxiety in young patients. The use of new technologies has avoided these instruments and has promoted more comfort to the patients. This study presents clinical cases in which gingivectomy was performed using the innovative method with an ultrasound-activated CVD tip. It was concluded that this method presented effectiveness, promoted more comfort, and less fear to the patients, making its use a viable alternative to pediatric surgery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: The conventional treatment protocol in high-intensity focused ultrasound (HIFU) therapy utilizes a dense-scan strategy to produce closely packed thermal lesions aiming at eradicating as much tumor mass as possible. However, this strategy is not most effective in terms of inducing a systemic anti-tumor immunity so that it cannot provide efficient micro-metastatic control and long-term tumor resistance. We have previously provided evidence that HIFU may enhance systemic anti-tumor immunity by in situ activation of dendritic cells (DCs) inside HIFU-treated tumor tissue. The present study was conducted to test the feasibility of a sparse-scan strategy to boost HIFU-induced anti-tumor immune response by more effectively promoting DC maturation. METHODS: An experimental HIFU system was set up to perform tumor ablation experiments in subcutaneous implanted MC-38 and B16 tumor with dense- or sparse-scan strategy to produce closely-packed or separated thermal lesions. DCs infiltration into HIFU-treated tumor tissues was detected by immunohistochemistry and flow cytometry. DCs maturation was evaluated by IL-12/IL-10 production and CD80/CD86 expression after co-culture with tumor cells treated with different HIFU. HIFU-induced anti-tumor immune response was evaluated by detecting growth-retarding effects on distant re-challenged tumor and tumor-specific IFN-gamma-secreting cells in HIFU-treated mice. RESULTS: HIFU exposure raised temperature up to 80 degrees centigrade at beam focus within 4 s in experimental tumors and led to formation of a well-defined thermal lesion. The infiltrated DCs were recruited to the periphery of lesion, where the peak temperature was only 55 degrees centigrade during HIFU exposure. Tumor cells heated to 55 degrees centigrade in 4-s HIFU exposure were more effective to stimulate co-cultured DCs to mature. Sparse-scan HIFU, which can reserve 55 degrees-heated tumor cells surrounding the separated lesions, elicited an enhanced anti-tumor immune response than dense-scan HIFU, while their suppressive effects on the treated primary tumor were maintained at the same level. Flow cytometry analysis showed that sparse-scan HIFU was more effective than dense-scan HIFU in enhancing DC infiltration into tumor tissues and promoting their maturation in situ. CONCLUSION: Optimizing scan strategy is a feasible way to boost HIFU-induced anti-tumor immunity by more effectively promoting DC maturation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este estudo visou verificar o efeito da sonoforese com Arnica montana sobre a fase inflamatória aguda de uma lesão muscular. Para isso, 40 ratos Wistar machos, lesados cirurgicamente, foram divididos em 4 grupos: controle (C), 10 ratos lesados e não tratados; grupo ultra-som (US), 10 lesados, tratados com US; grupo ultra-som com arnica (US+A), 10 ratos lesados, tratados com sonoforese de gel de arnica; grupo arnica (A), 10 ratos lesados, tratados com massagem de gel de arnica. O tratamento dos três grupos foi iniciado 24h após a lesão, sendo aplicado uma vez ao dia durante 3 minutos, por três dias. Quatro dias após a lesão, os animais foram sacrificados e o terço médio do músculo tibial anterior lesado foi removido e tratado histologicamente. Os resultados da análise qualitativa mostram que, no grupo C, formou-se um intenso infiltrado de células inflamatórias no espaço intersticial e um processo de regeneração apenas iniciado. Nos grupos US e US+A foi detectado um avançado processo inflamatório, com tecido conjuntivo mais organizado e consistente. No grupo A foi detectada diminuição no número de células inflamatórias e uma desorganização em sua disposição, o que poderia levar a um atraso no processo de regeneração. Conclui-se que os grupos que receberam a aplicação do ultra-som e ultra-som com arnica apresentaram semelhante aceleração do processo inflamatório agudo, sugerindo ineficácia da sonoforese quando comparada à aplicação de apenas ultra-som.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The effects of ultrasound on the wound healing process after teeth extractions were studied histologically. The right upper incisor was extracted in 56 rats. They were divided into 2 groups, one control (I) and one experimental (II). Group II received ultrasound stimulation that was applied with the frequency of repetition of 1,000 Hz and pulse length of 2,000 us continuously, during five minutes daily since the extraction day until 24 hours before the death. The rats were sacrificed at 3, 6, 9, 12, 15, 18, and 21 postoperative days. The results showed a precocious granulation tissue formation, faster remodeling of osseous ridges, and consequently acceleration of the alveolar wound healing process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this study was to investigate the effects of ultrasound treatment and physical exercise on the velocity of bone consolidation and resistance to deformation. We performed osteotomy in the upper third of the right tibia of rats. Physical training consisted of swimming 1 h per day with a load of 5% b.w. for 30 days. Therapy with medium-intensity ultrasound was applied daily on the damaged area. Wistar rats were divided into the following groups: osteotomized sedentary animals with no ultrasound treatment (1.OSnUS), osteotomized trained animals with no ultrasound treatment (2.OTnUS), osteotomized sedentary animals with ultrasound treatment (3.OSwUS). and osteotomized trained animals with ultrasound treatment (4.OTwUS). The animals were sacrificed for the following analyses: muscle glycogen, serum alkaline phosphatase at the 5th, 10th, 20th, and 30th days, test of maximum resistance to flexion, rupture flexion and mean tibial rigidity at the 30th day. Muscle glycogen was increased at the 20th day: alkaline phosphatase was elevated at the 5th and 20th days in groups 3.OSwUS and 4.OTwUS. and decreased at the 10th day. Groups1.OSnUS and 2.OTnUS did not show significant variations. In the mechanical resistance tests, we noted that ultrasound therapy and the association of physical activity used in the present study showed significant differences in bone resistance and bone rigidity after 30 days of treatment. These facts suggest that ultrasound or physical activity, or their combination may accelerate the process of bone tissue repair.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The effects of low-intensity pulsed ultrasound on wound healing were evaluated at the graft-cornea transition in dogs following lamellar keratoplasty using tunica vaginalis preserved in 98% glycerin. Twenty-one dogs were subdivided into three groups of seven animals. The first group (W/US) received daily treatment of low-intensity pulsed ultrasound (20 mW/cm 2) for 15 min for the first 10 days post surgery. The second group (N/US) was submitted to the same procedure but with the ultrasound apparatus turned off. The third group, the control (CO), underwent the surgical procedure only. The animals were clinically evaluated during the initial (1-15 days), intermediate (16-30 days) and late (31-120 days) postoperative period. The corneas were evaluated by light microscopy at 1, 3, 7, 15, 30, 60 and 120 days after surgery. Clinically, there were no differences which would promote an advantage to any of the treatments. Light microscopy, however, revealed more extensive vascularization and more advanced wound healing in the W/US group, as well as a tendency towards early graft incorporation. Based on the present results, low-intensity pulsed ultrasound shows advantages, especially in situations where trophic support is a mandatory condition, facilitating better graft incorporation and rapid recovery of stromal organization.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to determine the cutting ability of chemical vapor deposition (CVD) diamond burs coupled to an ultrasonic dental unit handpiece for minimally invasive cavity preparation. One standard cavity was prepared on the mesial and distal surfaces of 40 extracted human third molars either with cylindrical or with spherical CVD burs. The cutting ability was compared regarding type of substrate (enamel and dentin) and direction of handpiece motion. The morphological characteristics, width and depth of the cavities were analyzed and measured using scanning electron micrographs. Statistical analysis using the Kruskal-Wallis test (p < 0.05) revealed that the width and depth of the cavities were significantly greater when they were prepared on dentin. Wider cavities were prepared when the cylindrical CVD bur was used, and deeper cavities resulted from preparation with the spherical CVD bur. The direction of handpiece motion did not influence the size of the cavities, and the CVD burs produced precise and conservative cutting.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the shape of dental cavities made with the CVDentus® system using different ultrasound power levels. One standard cavity was made on the buccal aspect of 15 bovine incisors with a CVDentus® cylindrical bur (82142). The sample was divided into three groups: G1 - ultrasound with power II; G2 - ultrasound with power III; and G3 - ultrasound with power IV. A standardizing device was used to obtain standardized preparations and ultrasound was applied during one minute in each dental preparation. The cavities were sectioned in the middle, allowing observation of the cavity's profile with a magnifying glass, and width and depth measurement using the Leica Qwin program. The Kruskal-Wallis (p < 0.05) and Dunn statistical analyses demonstrated differences between the dental cavity shapes when powers III and IV were used. However, the cavities that were made with power III presented dimensions similar to those of the bur used for preparation. We concluded that the power recommended by the manufacturer (III) is the most adequate for use with the CVDentus® system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a ação precoce do laser terapêutico e do ultrassom no processo de regeneração de uma lesão experimental em ratos. MÉTODO: Utilizou-se 24 ratos. Dezoito foram submetidos ao procedimento cirúrgico de lesão do nervo ciático por compressão, através de uma pinça hemostática acima da fossa poplítea. Os animais foram divididos em três grupos com seis animais em cada. Grupo controle normal. GI: controle lesado sem intervenção terapêutica. GII: intervenção terapêutica do laser ArGaAl. GIII: intervenção terapêutica do ultrassom Pulsado. Iniciamos as intervenções terapêuticas 24 horas após a lesão, com aplicações diárias, por um período de quatorze dias consecutivos. RESULTADOS: Ao avaliar a perimetria dos músculos da coxa direita obteve-se os seguintes valores médios de diminuição (mm), para cada grupo GI: 0,45; GII: 0,42; GIII: 0,40. Quanto ao tempo de deslocamento tanto o GII e GIII apresentaram diferença significativa, quando comparados ao GI. Na avaliação final do IFC o GII sobressaiu ao GIII. Quanto a cicatrização observou-se grande melhora no GII e GIII. CONCLUSÃO: Os resultados evidenciaram que a recuperação nervosa foi maior com a aplicação do laser. Nível de evidência II, Estudos terapêuticos - Investigação dos resultados do tratamento

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar o efeito dos tempos de aplicação 3, 4 e 5 minutos por ERA do ultrassom terapêutico (UST) na organização das fibras de colágeno em lesão do tendão do calcâneo de ratos. Foram utilizados quarenta ratos machos Wistar, dos quais 32 sofreram tenotomia total do tendão do calcâneo e foram divididos em 5 grupos: GC, sem tenotomia e tratamento; GT, com tenotomia e sem tratamento; UST3, UST4 e UST5 submetidos à tenotomia e tratados com UST nos tempos de 3, 4 e 5 minutos por área de radiação efetiva respectivamente. Os animais foram submetidos à primeira aplicação do UST foi 24 horas após a cirurgia de tenotomia. A irradiação ultrassônica foi aplicada com os seguintes parâmetros: 1 MHz, modo pulsado com 20% do ciclo de trabalho (2 ms de emissão / 8 ms de intervalo), frequência de 100 Hz, 0,5 W / cm² de intensidade e ERA de 0,5 cm². A aplicação foi realizada 1x/dia. Os animais foram sacrificados após a 10ª sessão de tratamento, no 12º dia pós-operatório. Os tendões foram retirados cirurgicamente para análise da organização das fibras colágenas através do método de birrefringência (retardo óptico - OR). As fibras colágenas mostraram melhor agregação e organização no grupo UST3, UST4 e UST5 quando comparado ao GT (p<0.05) e o UST5 apresentou melhor resposta na comparação intergrupos. Conclui-se que o UST, aplicado no tempo de 5 minutos por área de radiação efetiva, apresentou a melhor dose-resposta quanto à organização das fibras colágenas no reparo tecidual de tendões de ratos

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To compare the efficiency of an Aeroneb Pro vibrating plate and an Atomisor MegaHertz ultrasonic nebulizer for providing ceftazidime distal lung deposition.Design: In vitro experiments. One gram of cetazidime was nebulized in respiratory circuits and mass median aerodynamic diameter of particles generated by ultrasonic and vibrating plate nebulizers was compared using a laser velocimeter. In vivo experiments. Lung tissue concentrations and extrapulmonary depositions were measured in ten anesthetized ventilated piglets with healthy lungs that received 1 g of ceftazidime by nebulization with either an ultrasonic (n = 5), or a vibrating plate (n = 5) nebulizer.Setting: A two-bed Experimental Intensive Care Unit of a University School of Medicine.Intervention: Following sacrifice, 5 subpleural specimens were sampled in dependent and nondependent lung regions for measuring ceftazidime lung tissue concentrations by high-performance liquid chromatography.Measurements and results: Mass median aerodynamic diameters generated by both nebulizers were similar with more than 95% of the particles between 0.5 and 5 mu m. Lung tissue concentrations were 553 +/- 123 [95% confidence interval: 514-638] mu g g(-1) using ultrasonic nebulizer, and 452 +/- 172 [95% confidence interval: 376-528] mu g g(-1) using vibrating plate nebulizers (NS). Extrapulmonary depositions were, respectively, of 38 +/- 5% (ultrasonic) and 34 +/- 4% (vibrating plate) (NS).Conclusions: Vibrating plate nebulizer is comparable to ultrasonic nebulizers for ceftazidime nebulization. It may represent a new attractive technology for inhaled antibiotic therapy.