995 resultados para Ultrasonic propagation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Measurement of tendon loading patterns during gait is important for understanding the pathogenesis of tendon "overuse" injury. Given that the speed of propagation of ultrasound in tendon is proportional to the applied load, this study used a noninvasive ultrasonic transmission technique to measure axial ultrasonic velocity in the right Achilles tendon of 27 healthy adults (11 females and 16 males; age, 26 ± 9 years; height, 1.73 ± 0.07 m; weight, 70.6 ± 21.2 kg), walking at self-selected speed (1.1 ± 0.1 m/s), and running at fixed slow speed (2 m/s) on a treadmill. Synchronous measures of ankle kinematics, spatiotemporal gait parameters, and vertical ground reaction forces were simultaneously measured. Slow running was associated with significantly higher cadence, shorter step length, but greater range of ankle movement, higher magnitude and rate of vertical ground reaction force, and higher ultrasonic velocity in the tendon than walking (P < 0.05). Ultrasonic velocity in the Achilles tendon was highly reproducible during walking and slow running (mean within-subject coefficient of variation < 2%). Ultrasonic maxima (P1, P2) and minima (M1, M2) were significantly higher and occurred earlier in the gait cycle (P1, M1, and M2) during running than walking (P < 0.05). Slow running was associated with higher and earlier peaks in loading of the Achilles tendon than walking.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ultrasonic absorption has been studied by the pulse technique in the binary mixtures of acetic acid in water, methyl and ethyl alcohols and covers a range of 2 to 26 Mc/s. The mixtures are studied from 0 to 100% by weight of the acid. In all the three mixtures, two relaxation processes are observed, the first occurring below the frequency range of the study. The second one occurs near 20 Mc/s in the acid-water mixtures and at much higher frequencies in the other cases. It is qualitatively explained that the monomer-dimer reaction of the acetic acid giving a relaxation near 1 Mc/s has shifted to a higher frequency when mixed in a solvent thus giving rise to a second relaxation in the mixtures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using the pulse method in the range of 2 to 26Mc's the ultrasonic absorption, velocity and the adiabatic compressibility have been studied in eleven aqueous acetate solutions up to a concentration of 1 mole/litre. The substances studied are the acetates of lithium, sodium, potassium, ammonium, magnesium, calcium, strontium, barium, zinc, cadmium and lead. Absorption in mercuric acetate has been studied only at 2 and 6 Mc/s. Two regions of relaxation are noticed, one below 10 Mc/s and the other between 10 and 26 Mc/s. The first relaxation is ascribed to the dissociation reaction of the salt and the second one to the monomerdimer reaction of the acetic acid formed by the hydrolysis of the salt in water.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Measurements of ultrasonic attenuation and velocity in milk and low concentration water-in-oil (W/O) emulsion were conducted, using a measurement cell with a double-element transducer that eliminates diffraction losses. The milk is characterized by the attenuation coefficient, while in the case of water-in-oil emulsions, the characterization is best represented by the propagation velocity.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Los métodos de detección rápida de microorganismos se están convirtiendo en una herramienta esencial para el control de calidad en el área de la biotecnología, como es el caso de las industrias de alimentos y productos farmacéuticos y bioquímicos. En este escenario, el objetivo de esta tesis doctoral es desarrollar una técnica de inspección rápida de microoganismos basada en ultrasonidos. La hipótesis propuesta es que la combinación de un dispositivo ultrasónico de medida y un medio líquido diseñado específicamente para producir y atrapar burbujas, pueden constituir la base de un método sensible y rápido de detección de contaminaciones microbianas. La técnica presentada es efectiva para bacterias catalasa-positivas y se basa en la hidrólisis del peróxido de hidrógeno inducida por la catalasa. El resultado de esta reacción es un medio con una creciente concentración de burbujas. Tal medio ha sido estudiado y modelado desde el punto de vista de la propagación ultrasónica. Las propiedades deducidas a partir del análisis cinemático de la enzima se han utilizado para evaluar el método como técnica de inspección microbiana. En esta tesis, se han investigado aspectos teóricos y experimentales de la hidrólisis del peróxido de hidrógeno. Ello ha permitido describir cuantitativamente y comprender el fenómeno de la detección de microorganismos catalasa-positivos mediante la medida de parámetros ultrasónicos. Más concretamente, los experimentos realizados muestran cómo el oxígeno que aparece en forma de burbujas queda atrapado mediante el uso de un gel sobre base de agar. Este gel fue diseñado y preparado especialmente para esta aplicación. A lo largo del proceso de hidrólisis del peróxido de hidrógeno, se midió la atenuación de la onda y el “backscattering” producidos por las burbujas, utilizando una técnica de pulso-eco. Ha sido posible detectar una actividad de la catalasa de hasta 0.001 unidades/ml. Por otra parte, este estudio muestra que por medio del método propuesto, se puede lograr una detección microbiana para concentraciones de 105 células/ml en un periodo de tiempo corto, del orden de unos pocos minutos. Estos resultados suponen una mejora significativa de tres órdenes de magnitud en comparación con otros métodos de detección por ultrasonidos. Además, la sensibilidad es competitiva con modernos y rápidos métodos microbiológicos como la detección de ATP por bioluminiscencia. Pero sobre todo, este trabajo muestra una metodología para el desarrollo de nuevas técnicas de detección rápida de bacterias basadas en ultrasonidos. ABSTRACT In an industrial scenario where rapid microbiological methods are becoming essential tools for quality control in the biotechnological area such as food, pharmaceutical and biochemical; the objective of the work presented in this doctoral thesis is to develop a rapid microorganism inspection technique based on ultrasounds. It is proposed that the combination of an ultrasonic measuring device with a specially designed liquid medium, able to produce and trap bubbles could constitute the basis of a sensitive and rapid detection method for microbial contaminations. The proposed technique is effective on catalase positive microorganisms. Well-known catalase induced hydrogen peroxide hydrolysis is the fundamental of the developed method. The physical consequence of the catalase induced hydrogen peroxide hydrolysis is an increasingly bubbly liquid medium. Such medium has been studied and modeled from the point of view of ultrasonic propagation. Properties deduced from enzyme kinematics analysis have been extrapolated to investigate the method as a microbial inspection technique. In this thesis, theoretical and experimental aspects of the hydrogen peroxide hydrolysis were analyzed in order to quantitatively describe and understand the catalase positive microorganism detection by means of ultrasonic measurements. More concretely, experiments performed show how the produced oxygen in form of bubbles is trapped using the new gel medium based on agar, which was specially designed for this application. Ultrasonic attenuation and backscattering is measured in this medium using a pulse-echo technique along the hydrogen peroxide hydrolysis process. Catalase enzymatic activity was detected down to 0.001 units/ml. Moreover, this study shows that by means of the proposed method, microbial detection can be achieved down to 105 cells/ml in a short time period of the order of few minutes. These results suppose a significant improvement of three orders of magnitude compared to other ultrasonic detection methods for microorganisms. In addition, the sensitivity reached is competitive with modern rapid microbiological methods such as ATP detection by bioluminescence. But above all, this work points out a way to proceed for developing new rapid microbial detection techniques based on ultrasound.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El proyecto de rehabilitación de una de las naves del complejo fabril de la industria química ?CROS? en Valencia se llevó a cabo con el criterio de mantener, en la medida de lo posible, los elementos estructurales presentes en la nave. Con este objetivo se realizaron una serie de ensayos no destructivos (END) in situ. Estos ensayos permitieron evaluar la calidad de la madera, determinar qué elementos estructurales debían ser sustituidos y comprobar la aptitud de los que iban a ser reutilizados. Los END empleados en este estudio fueron los siguientes: (1) Identificación de la especie por técnicas anatómicas, (2) Clasificación resistente por método visual, (3) Estimación de humedad por la técnica de resistencia eléctrica; (4) Obtención de velocidades de propagación ultrasónicas (5) Resistógrafía y (6) Alteración de la propagación de ondas electromagnéticas por medio de Georradar. Para la calibración de estos END se tomó una muestra de piezas y se hicieron ensayos destructivos bajo condiciones controladas en laboratorio. En el trabajo que aquí se presenta se muestra la metodología empleada durante el proceso de toma de datos, de análisis de resultados y de cruce de la información obtenida a partir de cada uno de los ensayos hasta llegar a un diagnóstico para los elementos analizados. The assessment of structural timber was requested in the rehabilitation project of the Naves of the chemical industry "CROS". The criterion was to maintain as much as possible timber of the structure and to make only partial replacements. In order not to damage the existing structure and to assess the quality of the existing timber, a series of non-destructive testing (NDT) in the entire structure were performed: (1) Identification of the species by anatomical techniques, (2) Strength grading by visual method, (3) Estimation of moisture content by the technique of electrical resistance, (4) Acquisition of ultrasonic propagation velocities (5) Resistography and (6) Record of the propagation of electromagnetic waves by means of Ground-penetrating radar. Following, a sample group was chose to carry out destructive testing in the lab and compare the NDT results with those obtained with the standard UNE-EN408 (modules of strength, stiffness and density). In the present work, the results provided by each of the NDT techniques are detailed and above all, what is more important, the validity of these after they have been contrasted with the destructive standard tests.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La calidad del hormigón prefabricado se determina mediante ensayos de rotura a compresión en probetas transcurridos los 28 días de curado, según establece la EHE-08. Sin embargo, en la plantas de prefabricados es necesario además saber cuándo el hormigón está listo para ser procesado (destensado, cortado, trasladado), por lo que es necesario hacer ensayos de resistencia a la compresión entre las 48 y 72 horas, este tiempo se determina a partir de la experiencia previa adquirida y depende de las condiciones de cada planta. Si las probetas no han alcanzado el valor establecido, normalmente debido a un cambio en las condiciones climatológicas o en los materiales utilizados como el tipo de cemento o agregados, la solución adoptada suele ser dejar curar el material más horas en la pista para que alcance la resistencia necesaria para ser procesado. Si sigue sin alcanzarla, lo cual sucede muy ocasionalmente, se intenta analizar cuál ha sido el motivo, pudiéndose tirar toda la producción de ese día si se comprueba que ha sido un fallo en la fabricación de la línea, y no un fallo de la probeta. Por tanto, esta metodología de control de calidad, basada en técnicas destructivas, supone dos tipos de problemas, costes y representatividad. Los métodos no destructivos que más se han aplicado para caracterizar el proceso de curado del hormigón son los ultrasónicos y la medida de la temperatura como se recoge en la bibliografía consultada. Hay diferentes modelos que permiten establecer una relación entre la temperatura y el tiempo de curado para estimar la resistencia a compresión del material, y entre la velocidad de propagación ultrasónica y la resistencia. Aunque estas relaciones no son generales, se han obtenido muy buenos resultados, ejemplo de ello es el modelo basado en la temperatura, Maturity Method, que forma parte de la norma de la ASTM C 1074 y en el mercado hay disponibles equipos comerciales (maturity meters) para medir el curado del hormigón. Además, es posible diseñar sistemas de medida de estos dos parámetros económicos y robustos; por lo cual es viable la realización de una metodología para el control de calidad del curado que pueda ser implantado en las plantas de producción de prefabricado. En este trabajo se ha desarrollado una metodología que permite estimar la resistencia a la compresión del hormigón durante el curado, la cual consta de un procedimiento para el control de calidad del prefabricado y un sistema inalámbrico de sensores para la medida de la temperatura y la velocidad ultrasónica. El procedimiento para el control de calidad permite realizar una predicción de la resistencia a compresión a partir de un modelo basado en la temperatura de curado y otros dos basados en la velocidad, método de tiempo equivalente y método lineal. El sistema inalámbrico de sensores desarrollado, WilTempUS, integra en el mismo dispositivo sensores de temperatura, humedad relativa y ultrasonidos. La validación experimental se ha realizado mediante monitorizaciones en probetas y en las líneas de prefabricados. Los resultados obtenidos con los modelos de estimación y el sistema de medida desarrollado muestran que es posible predecir la resistencia en prefabricados de hormigón en planta con errores comparables a los aceptables por norma en los ensayos de resistencia a compresión en probetas. ABSTRACT Precast concrete quality is determined by compression tests breakage on specimens after 28 days of curing, as established EHE-08. However, in the precast plants is also necessary to know when the concrete is ready to be processed (slack, cut, moved), so it is necessary to test the compressive strength between 48 and 72 hours. This time is determined from prior experience and depends on the conditions of each plant. If the samples have not reached the set value, usually due to changes in the weather conditions or in the materials used as for example the type of cement or aggregates, the solution usually adopted is to cure the material on track during more time to reach the required strength for processing. If the material still does not reach this strength, which happens very occasionally, the reason of this behavior is analyzed , being able to throw the entire production of that day if there was a failure in the manufacturing line, not a failure of the specimen. Therefore, this method of quality control, using destructive techniques, involves two kinds of problems, costs and representativeness. The most used non-destructive methods to characterize the curing process of concrete are those based on ultrasonic and temperature measurement as stated in the literature. There are different models to establish a relationship between temperature and the curing time to estimate the compressive strength of the material, and between the ultrasonic propagation velocity and the compressive strength. Although these relationships are not general, they have been very successful, for example the Maturity Method is based on the temperature measurements. This method is part of the standards established in ASTM C 1074 and there are commercial equipments available (maturity meters) in the market to measure the concrete curing. Furthermore, it is possible to design inexpensive and robust systems to measure ultrasounds and temperature. Therefore is feasible to determine a method for quality control of curing to be implanted in the precast production plants. In this work, it has been developed a methodology which allows to estimate the compressive strength of concrete during its curing process. This methodology consists of a procedure for quality control of the precast concrete and a wireless sensor network to measure the temperature and ultrasonic velocity. The procedure for quality control allows to predict the compressive strength using a model based on the curing temperature and two other models based on ultrasonic velocity, the equivalent time method and the lineal one. The wireless sensor network, WilTempUS, integrates is the same device temperature, relative humidity and ultrasonic sensors. The experimental validation has been carried out in cubic specimens and in the production plants. The results obtained with the estimation models and the measurement system developed in this thesis show that it is possible to predict the strength in precast concrete plants with errors within the limits of the standards for testing compressive strength specimens.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An ultrasonic thermometer has been developed for high temperature measurement over a wide temperature range. It is particularly suitable for use in measuring nuclear fuel rod centerline temperatures in advanced liquid metal and high flux nuclear reactors. The thermometer which was designed to determine fuel temperature up to the fuel melting point, utilizes the temperature dependence of the ultrasonic propagation velocity (related to the elastic modulus} in a thin rod sensor as the temperature transducing mechanism. A pulse excitation technique has been used, where the mechanical resonator at the remote end of the acoustic·line is madto vibrate. Its natural frequency is proportional to the ultrasonic velocity in the material. This is measured by the electronic instrumentation and enables a frequency­ temperature or period-temperature calibration to be obtained. A completely digital automatic instrument has been designed, constructed and tested to track the resonance frequency of the temperature sensors. It operates smoothly over a frequency range of about 30%, more than the maximum working range of most probe materials. The control uses the basic property of a resonator that the stored energy decays exponentially at the natural frequency of the resonator.The operation of the electronic system is based on a digital multichannel transmitter that is capable of operating with a predefined number of cycles in the burst. this overcomes a basic defect in the previous deslgn where the analogue time-delayed circuits failed to hold synchronization and hence automatic control could be lost. Development of a particular type of temperature probe, that is small enough to fit into a standard 2 mm reactor tube has made the ultrasonic thermometer a practicable device for measuring fuel temperature. The bulkiness of previous probes has been overcome, the new design consists of a tuning fork, integral with a 1mm line, while maintaining a frequency of no more than 100 kHz. A magnetostrictive rod, acoustically matched to the probe is used to launch and receive the acoustic oscillations. This requires a magnetic bias and the previously used bulky magnets have been replaced by a direct current coil. The probe is supported by terminating the launcher with a short heavy isolating rod which can be secured to the reactor structure. This support, the bias and launching coil and the launcher are made up into a single compact unit. On the material side an extensive study of a wide range of refractory materials identified molybdenum, iridium, rhenium and tungsten as satisfactory for a number of applications but mostly exhibiting to some degree a calibration drift with thermal cycling. When attention was directed to ceramic materials, Sapphire (single crystal alumina) was found to have numerous advantages, particularly in respect of stability of calibration which remained with ±2°C after many cycles to 1800oC. Tungsten and thoriated tungsten (W - 2% Tho2) were also found to be quite satisfactory to 1600oC, the specification for a Euratom application.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper studies the effect of longitudinal magnetic field on ultrasonic vibration in single walled carbon nanotubes (CNTs) based on nonlocal continuum medium theory. Governing partial differential equations of CNTs are derived by considering the Lorentz magnetic forces applied on CNTs induced by a longitudinal magnetic field through Maxwell equations. The vibration characteristics of CNTs under a longitudinal magnetic field are obtained by solving the governing equations via wave propagation approach. The effects of longitudinal magnetic field on vibration of CNTs are discussed through numerical experiments. The present analysis show that vibration frequencies of CNTs drops dramatically in the presence of the magnetic field for various circumferential wavenumbers. Such effect is also observed for various boundary conditions of the CNT. New features for the effect of longitudinal magnetic field on ultrasonic vibration of CNTs, presented in this paper are useful in the design of nano-drive device, nano-oscillator and actuators and nano-electron technology, where carbon nanotubes act as basic elements.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Rapid diagnostics and virtual imaging of damages in complex structures like folded plate can help reduce the inspection time for guided wave based NDE and integrated SHM. Folded plate or box structure is one of the major structural components for increasing the structural strength. Damage in the folded plate, mostly in the form of surface breaking cracks in the inaccessible zone is a usual problem in aerospace structures. One side of the folded plate is attached (either riveted or bonded) to adjacent structure which is not accessible for immediate inspection. The sensor-actuator network in the form of a circular array is placed on the accessible side of the folded plate. In the present work, a circular array is employed for scanning the entire folded plate type structure for damage diagnosis and wave field visualization of entire structural panel. The method employs guided wave with relatively low frequency bandwidth of 100-300 kHz. Change in the response signal with respect to a baseline signal is used to construct a quantitative relationship with damage size parameters. Detecting damage in the folded plate by using this technique has significant potential for off-line and on-line SHM technologies. By employing this technique, surface breaking cracks on inaccessible face of the folded plate are detected without disassembly of structure in a realistic environment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The ultrasonic non-destructive testing of components may encounter considerable difficulties to interpret some inspections results mainly in anisotropic crystalline structures. A numerical method for the simulation of elastic wave propagation in homogeneous elastically anisotropic media, based on the general finite element approach, is used to help this interpretation. The successful modeling of elastic field associated with NDE is based on the generation of a realistic pulsed ultrasonic wave, which is launched from a piezoelectric transducer into the material under inspection. The values of elastic constants are great interest information that provide the application of equations analytical models, until small and medium complexity problems through programs of numerical analysis as finite elements and/or boundary elements. The aim of this work is the comparison between the results of numerical solution of an ultrasonic wave, which is obtained from transient excitation pulse that can be specified by either force or displacement variation across the aperture of the transducer, and the results obtained from a experiment that was realized in an aluminum block in the IEN Ultrasonic Laboratory. The wave propagation can be simulated using all the characteristics of the material used in the experiment evaluation associated to boundary conditions and from these results, the comparison can be made.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Footwear remains a prime candidate for the prevention and rehabilitation of Achilles tendinopathy as it is thought to decrease tension in the tendon through elevation of the heel. However, evidence for this effect is equivocal. Purpose: This study used an acoustic transmission technique to investigate the effect of running shoes on Achilles tendon loading during barefoot and shod walking. Methods: Acoustic velocity was measured in the Achilles tendon of twelve recreationally–active males (age, 31±9 years; height, 1.78±0.06 m; weight, 81.0±16.9 kg) during barefoot and shod walking at matched self–selected speed (3.4±0.7 km/h). Standard running shoes incorporating a 10– mm heel offset were used. Vertical ground reaction force and spatiotemporal parameters were determined with an instrumented treadmill. Axial acoustic velocity in the Achilles tendon was measured using a custom built ultrasonic device. All data were acquired at a rate of 100 Hz during 10s of steady–state walking. Statistical comparisons between barefoot and shod conditions were made using paired t–tests and repeated measure ANOVAs. Results: Acoustic velocity in the Achilles tendon was highly reproducible and was typified by two maxima (P1, P2) and minima (M1, M2) during walking. Footwear resulted in a significant increase in step length, stance duration and peak vertical ground reaction force compared to barefoot walking. Peak acoustic velocity in the Achilles tendon (P1, P2) was significantly higher with running shoes. Conclusions: Peak acoustic velocity in the Achilles tendon was higher with footwear, suggesting that standard running shoes with a 10–mm heel offset increase tensile load in the Achilles tendon. Although further research is required, these findings question the therapeutic role of standard running shoes in Achilles tendinopathy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Modeling and analysis of wave propagation in elastic solids undergoing damage and growth process are reported in this paper. Two types of diagnostic problems, (1) the propagation of waves in the presence of a slow growth process and (2) the propagation of waves in the presence of a fast growth process, are considered. The proposed model employs a slow and a fast time scale and a homogenization technique in the wavelength scale. A detailed analysis of wave dispersion is carried out. A spectral analysis reveals certain low-frequency bands, where the interaction between the wave and the growth process produces acoustic metamaterial-like behavior. Various practical issues in designing an efficient method of acousto-ultrasonic wave based diagnostics of the growth process are discussed. Diagnostics of isotropic damage in a ductile or quasi-brittle solid by using a micro-second pulsating signal is considered for computer simulations, which is to illustrate the practical application of the proposed modeling and analysis. The simulated results explain how an estimate of signal spreading can be effectively employed to detect the presence of a steady-state damage or the saturation of a process.