952 resultados para ULTRASOUND VELOCITY
Resumo:
Objective: An experimental in vitro study was carried out to evaluate the influence of cortical bone thickness on ultrasound propagation velocity. Methods: Sixty bone plates were used, made from bovine femurs, with thickness ranging from 1 to 6 mm (10 of each). The ultrasound velocity measurements were performed using a device specially designed for this purpose, in an underwater acoustic tank and with direct contact using contact gel. The transducers were positioned in two ways: on opposite sides, with the bone between them, for the transverse measurement; and parallel to each other, on the same side of the bone plates, for the axial measurements. Results: In the axial transmission mode, the ultrasound velocity speed increased with cortical bone thickness, regardless of the distance between the transducers, up to a thickness of 5 mm, then remained constant thereafter. There were no changes in velocity when the transverse measures were made. Conclusion: Ultrasound velocity increased with cortical bone thickness in the axial transmission mode, until the thickness surpasses the wavelength, after which point it remained constant. Level of Evidence: Experimental Study.
Resumo:
Measurement of loading patterns of the patellar tendon during activity is important in understanding tendon injury. We used transmission-mode ultrasonography to investigate patellar tendon loading during squatting in adults with and without tendinopathy. It was hypothesized that axial ultrasonic velocity, a surrogate measure of the elastic modulus of tendon, would be lower in tendinopathy. Ultrasound velocity was measured in both patellar tendons of adults with unilateral patellar tendinopathy (n=9) and in healthy controls (n=16) during a bilateral squat manoeuvre. Sagittal knee movement was measured simultaneously with an electrogoniometer. Statistical comparisons between healthy and injured tendons were made using 2–way mixed–design ANOVAs. Axial ultrasound velocity in both symptomatic and asymptomatic patellar tendons in tendinopathy was approximately 15% higher than in healthy tendons at the commencement (F1,23=5.2, P<.05) and completion (F1,23=4.5, P<.05) of the squat. While peak velocity was ≈5% higher during both flexion (F1,23=5.4, P<.05) and extension (F1,23=5.3, P<.05) phases, there was no significant between–group difference at the mid–point of the movement. There were no significant differences in the rate and magnitude of knee movement between groups. Although further research is required, these findings suggest enhanced baseline muscle activity in patellar tendinopathy and highlight fresh avenues for its clinical management.
A Comparative Analysis between Ultrasonometry and Computer-Aided Tomography to Evaluate Bone Healing
Resumo:
An ultrasonometric and computed-tomographic study of bone healing was undertaken using a model of a transverse mid-shaft osteotomy of sheep tibiae fixed with a semi-flexible external fixator. Fourteen sheep were operated and divided into two groups of seven according to osteotomy type, either regular or by segmental resection. The animals were killed on the 90th postoperative day and the tibiae resected for the in vitro direct contact transverse and axial measurement of ultrasound propagation velocity (UV) followed by quantitative computer-aided tomography (callus density and volume) through the osteotomy site. The intact left tibiae were used for control, being examined in a symmetrical diaphyseal segment. Regular osteotomies healed with a smaller and more mature callus than resection osteotomies. Axial UV was consistently and significantly higher (p?=?0.01) than transverse UV and both transverse and axial UV were significantly higher for the regular than for the segmental resection osteotomy. Transverse UV did not differ significantly between the intact and operated tibiae (p?=?0.20 for regular osteotomy; p?=?0.02 for resection osteotomy), but axial UV was significantly higher for the intact tibiae. Tomographic callus density was significantly higher for the regular than for the resection osteotomy and higher than both for the intact tibiae, presenting a strong positive correlation with UV. Callus volume presented an opposite behavior, with a negative correlation with UV. We conclude that UV is at least as precise as quantitative tomography for providing information about the healing state of both regular and resection osteotomy. (C) 2011 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 30:10761082, 2012
Resumo:
OBJETIVO: Avaliar a influência da espessura do osso cortical sobre a velocidade de propagação do ultrassom (in vitro). MÉTODO: Foram utilizadas 60 lâminas ósseas confeccionadas a partir do fêmur de bovinos, com diferentes espessuras, variando de 1 a 6mm (10 de cada). As medidas da velocidade do ultrassom foram realizadas por aparelho projetado para este fim, utilizando técnica subaquática e por contato direto com auxílio de gel de acoplamento. Os transdutores foram posicionados de duas maneiras diferentes; opostos entre si, com o osso entre eles, sendo a medida chamada de transversal; e, paralelos na mesma superfície cortical, sendo a medida chamada de axial. RESULTADOS: Com o modo de transmissão axial, a velocidade de propagação do ultrassom aumenta conforme a espessura do osso cortical aumenta, independente da distância entre os transdutores, até a espessura de 5mm, mantendo-se constante após. Não houve alteração da velocidade quando o modo de transmissão foi transversal. CONCLUSÃO: A velocidade de propagação do ultrassom aumenta com o aumento da espessura da cortical óssea, no modo de transmissão axial, até o momento em que a espessura supera o comprimento da onda, mantendo a velocidade constante a partir de então. Nível de Evidência: Estudo Experimental.
Resumo:
En la presente tesis doctoral se revisan las principales hipótesis que intentan aclarar los procesos constructivos llevados a cabo para edificar las pirámides egipcias de las Dinastías III y IV, organizándose dichas teorías desde el punto de vista de los posibles materiales constituyentes. La investigación se ha centrado en la hipótesis heterodoxa que propone, como medio para ejecutar estas construcciones, la manufactura completa de la pirámide con piedra caliza conglomerada. Con este fin, se profundiza en artículos que tienen por objeto el análisis de muestras de material de estos monumentos, de piedras calizas naturales y de piedras calizas geopoliméricas, con objeto de determinar si la hipótesis constructiva mencionada es viable. Tomando como referencia la hipótesis constructiva estudiada, se adicionan morteros de cal aérea con carbonato de sodio (natrón) y metacaolín, analizando posteriormente las nuevas características de estos conglomerantes. El cementante descrito en la teoría constructiva se enmarca dentro de la química y tecnología de los polímeros sintéticos inorgánicos activados alcalinamente, también denominados geopolímeros. Se desarrolla una primera mezcla basada en los datos extraídos de la investigación precedente. Posteriormente, se realizan varios grupos de mezclas, en las que se parte de unas proporciones iniciales correspondientes al geopolímero teórico de la hipótesis constructiva. Sobre dichas proporciones se realizan incrementos en la cantidad de cal, y los productos obtenidos son ensayados, tomando datos de: dureza Shore C, velocidad de ultrasonidos, densidades, resistencia a compresión y a flexión, difracción de rayos X, análisis térmicos y microscopía electrónica de barrido. Los resultados derivados de introducir las adiciones, en las proporciones estudiadas, mejoran notablemente algunas características de los morteros de cal convencionales. ABSTRACT In the present PhD thesis the main hypotheses about the construction processes to build the Egyptian pyramids of Dynasties III and IV are reviewed. These theories are addressed from the point of view of their possible constituent materials. The research focuses on the heterodox hypothesis that proposes, as a means to perform these constructions, the complete manufacturing of the pyramid with limestone conglomerate. In this regard, a state of the art is set on the analysis of samples of material of these monuments, natural limestone and limestone geopolymeric, to determine if the constructive hypothesis is viable. Using this constructive hypothesis as a reference, aerial lime mortars are added with sodium carbonate (natron) and metakaolin, and the new characteristics of these resulting binders are then analyzed. The cementing described in the constructive theory belongs to the chemistry and the technology of synthetic inorganic alkali-activated polymers, also called geopolymer. Based on data obtained from previous research, a first mix is prepared. Subsequently, several groups of mixes are made, starting from theoretical initial ratios corresponding to the geopolymer that was presumably used in the constructive hypothesis. Increments in the amount of lime are made upon such proportion, and the resulting products are tested for data collection about: Shore C hardness, ultrasound velocity, densities, compressive and flexural strength, X-ray diffraction, thermal analysis and scanning electron microscopy. The results allow to conclude that, if in the studied proportions, additions improve significantly some of the characteristics of conventional lime mortars.
Resumo:
The gelation profile of yoghurts from conventionally treated (85 degrees C/30 min) and UHT treated (143 degrees C/6s) milks at 16, 18, and 20% total solids was analyzed during fermentation for 4 hrs using the invasive Rapid Visco Analyzer (RVA) and the non-invasive ultrasonic spectroscope. The viscosity measured by the RVA and the ultrasonic velocity measured by the ultrasonic spectroscope exhibited similar sigmoid trends with respect to fermentation time. The ultrasonic spectroscope detected the onset of gelation of yoghurt milk earlier (by an average of 52 min) than did the RVA, indicating a higher sensitivity of ultrasonic spectroscopy. The delay of gelation time of UHT-treated yoghurt milk as compared to conventionally treated yoghurt milk was detected by both techniques. A non-significant ( P > 0.05) effect of solids content in the yoghurt milks on their gelation time was also observed by both instruments.
Resumo:
Systematic low-temperature measurements of the thermal conductivity, specific heat, dielectric constant, and temperature-dependent ultrasound velocity have been made on a single piece of vitreous silica. These measurements were repeated after fast neutron irradiation of the material. It was found that the irradiation produced changes of the same relative magnitude in the low-temperature excess specific heat C , the thermal conductivity K, ex and the anomalous temperature dependence of the ultrasound velocity Deltav/v. A corresponding change in the temperature dependent dielectric constant was not observed. It is therefore likely that K and Deltav/v are determined by the same localized excitations responsible for C , but the temperature dependence of the dielectric constant may have a different, though possibly related, origin. Furthermore, a consistent account for the measured C , K, ex and Deltav/v of unirradiated silica is given by the tunneling-state model with a single, energy-dependent density of states. Changes in these three properties due to irradiation can be explained by altering only the density of tunneling states incorporated in the model.
Resumo:
Wavelet entropy assesses the degree of order or disorder in signals and presents this complex information in a simple metric. Relative wavelet entropy assesses the similarity between the spectral distributions of two signals, again in a simple metric. Wavelet entropy is therefore potentially a very attractive tool for waveform analysis. The ability of this method to track the effects of pharmacologic modulation of vascular function on Doppler blood velocity waveforms was assessed. Waveforms were captured from ophthalmic arteries of 10 healthy subjects at baseline, after the administration of glyceryl trinitrate (GTN) and after two doses of N(G)-nitro-L-arginine-methyl ester (L-NAME) to produce vasodilation and vasoconstriction, respectively. Wavelet entropy had a tendency to decrease from baseline in response to GTN, but significantly increased after the administration of L-NAME (mean: 1.60 ± 0.07 after 0.25 mg/kg and 1.72 ± 0.13 after 0.5 mg/kg vs. 1.50 ± 0.10 at baseline, p < 0.05). Relative wavelet entropy had a spectral distribution from increasing doses of L-NAME comparable to baseline, 0.07 ± 0.04 and 0.08 ± 0.03, respectively, whereas GTN had the most dissimilar spectral distribution compared with baseline (0.17 ± 0.08, p = 0.002). Wavelet entropy can detect subtle changes in Doppler blood velocity waveform structure in response to nitric-oxide-mediated changes in arteriolar smooth muscle tone.
Resumo:
Ultrasound wave velocity was measured in 30 pieces of Spanish Scots pine (Pinus sylvestris L.), 90 x 140 mm in cross-section and 4 m long. Five different sensor placement arrangements were used: end to end (V0), face to opposite face, edge to opposite edge, face to same face and edge to same edge. The pieces were successively shortened to 3, 2 and 1 m, in order to obtain these velocities and their ratios to reference value V0 for different lengths and angles with respect to the piece axis for the crossed measurements. The velocity obtained in crossed measurements is lower than V0. A correction coefficient for crossed velocities is proposed, depending on the angle, to adjust them to the V0 benchmark. The velocities measured on a surface, are also lower than V0, and their ratio with respect to V0 is close to 0.97 for distances equal to or greater than 18 times the depth of the beam.
Resumo:
This research developed and scientifically validated a new ultrasound transmission computed tomography system with the aim of quantitative assessment of a polymer gel dosimeter including dose response verification of ultrasonic parameters of attenuation, velocity and broadband ultrasound attenuation (BUA). This work was the first to investigate and report ultrasound frequency dependent attenuation in a gel dosimeter, demonstrating a dose dependence.
Resumo:
Advanced composite structural components made up of Carbon Fibre Reinforced Polymers (CFRP) used in aerospace structures such as in Fuselage, Leading & Trailing edges of wing and tail, Flaps, Elevator, Rudder and entire wing structures encounter most critical type of damage induced by low velocity impact (<10 m/s) loads. Tool dropped during maintenance & service,and hailstone impacts on runways are common and unavoidable low-velocity impacts. These lowvelocity impacts induce defects such as delaminations, matrix cracking and debonding in the layered material, which are sub-surface in nature and are barely visible on the surface known as Barely Visible Impact Damage (BVID). These damages may grow under service load, leading to catastrophic failure of the structure. Hence detection, evaluation and characterization of these types of damage is of major concern in aerospace industries as the life of the component depends on the size and shape of the damage.In this paper, details of experimental investigations carried out and results obtained from a low-velocity impact of 30 Joules corresponding to the hailstone impact on the wing surface,simulated on the 6 mm CFRP laminates using instrumented drop-weight impact testing machine are presented. The Ultrasound C-scan and Infrared thermography imaging techniques were utilized extensively to detect, evaluate and characterize impact damage across the thickness of the laminates.
Resumo:
Using coherent light interrogating a turbid object perturbed by a focused ultrasound (US) beam, we demonstrate localized measurement of dynamics in the focal region, termed the region-of-interest (ROI), from the decay of the modulation in intensity autocorrelation of light. When the ROI contains a pipe flow, the decay is shown to be sensitive to the average flow velocity from which the mean-squared displacement (MSD) of the scattering centers in the flow can be estimated. While the MSD estimated is seen to be an order of magnitude higher than that obtainable through the usual diffusing wave spectroscopy (DWS) without the US, it is seen to be more accurate as verified by the volume flow estimated from it. It is further observed that, whereas the MSD from the localized measurement grows with time as tau(alpha) with alpha approximate to 1.65, without using the US, a is seen to be much less. Moreover, with the local measurement, this super-diffusive nature of the pipe flow is seen to persist longer, i.e., over a wider range of initial tau, than with the unassisted DWS. The reason for the super-diffusivity of flow, i.e., alpha < 2, in the ROI is the presence of a fluctuating (thermodynamically nonequilibrium) component in the dynamics induced by the US forcing. Beyond this initial range, both methods measure MSDs that rise linearly with time, indicating that ballistic and near-ballistic photons hardly capture anything beyond the background Brownian motion. (C) 2015 Optical Society of America
Resumo:
Real-time cardiac ultrasound allows monitoring the heart motion during intracardiac beating heart procedures. Our application assists atrial septal defect (ASD) closure techniques using real-time 3D ultrasound guidance. One major image processing challenge is the processing of information at high frame rate. We present an optimized block flow technique, which combines the probability-based velocity computation for an entire block with template matching. We propose adapted similarity constraints both from frame to frame, to conserve energy, and globally, to minimize errors. We show tracking results on eight in-vivo 4D datasets acquired from porcine beating-heart procedures. Computing velocity at the block level with an optimized scheme, our technique tracks ASD motion at 41 frames/s. We analyze the errors of motion estimation and retrieve the cardiac cycle in ungated images. © 2007 IEEE.
Resumo:
Aim: The aim of this study is to assess the murine heart of normal embryos, neonates, and juveniles using high-frequency ultrasound. Methods: Diastolic function was measured with E/A ratio (E wave velocity/A wave velocity) and isovolumetric relaxation time (IRT), systolic function with isovolumetric contraction time (ICT), percentage fractional shortening (FS%), percentage ejection fraction (EF%). Global cardiac performance was quantified using myocardial performance index (MPI). Results: Isovolumetric relaxation time remained stable from E10.5 to 3 weeks. Systolic function (ICT) improved with gestation and remained stable from E18.5 onward. Myocardial performance index showed improvement in embryonic lift (0.82-0.63) and then stabilized from 1 to 3 week (0.60-0.58). Percentage ejection fraction remained high during gestation (77%-69%) and then decreased from the neonate to juvenile (68%-51%). Conclusion: The ultrasound biomicroscope allows for noninvasive in-depth assessment of cardiac function of embryos and pups. Detailed physiological and functional cardiac function readouts can be obtained, which is invaluable for comparison to mouse models of disease.