971 resultados para Tunneled central catheter


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Catheter-related bacteremia (CRB) is one of the various complications related to hemodialysis (HD). As a result of this high rate of infection, the antibiotic lock technique (ALT) has been recommended to prevent CRB. However, adverse effects of ALT such as increased emergence of strains resistant to antibiotics and increased mechanical dysfunction catheter were poorly evaluated. We prospectively evaluated the efficacy of catheter-restricted filling using an antibiotic lock solution in preventing CRB. A total of 233 HD patients requiring 325 new tunneled catheters while waiting for placement and maturation of an arteriovenous fistula or graft were enrolled in this study. Patients with a tunneled catheter were assigned to receive either an antibiotic-heparin lock solution (antibiotic group: cefazolin 10 mg/ml, gentamicin 5 mg/ml, heparin 1,000 U/ml) or a heparin lock solution (no-antibiotic group: heparin 1,000 U/ml) as a catheter lock solution during the interdialytic period. The present study aimed to assess the efficacy of ALT using cefazolin and gentamicin in reducing CRB in patients undergoing HD with tunneled central catheter and to identify its adverse effects. CRB developed in 32.4 % of patients in the no-antibiotic group and in 13.1 % of patients in the antibiotic group. CRB rates per 1,000 catheter-days were 0.57 in the antibiotic group versus 1.74 in the no-antibiotic group (p < 0.0001). Kaplan-Meier analysis also showed that mean CRB-free catheter survival was significantly higher in the antibiotic group than in the no-antibiotic group (log-rank statistic 17.62, p < 0.0001). There was statistically significant difference between the two groups in causative organisms of CRB, with predominance of negative culture in both groups, but this prevalence was higher in ALT group (57.9 vs 90.1 %, p < 0.0001), and the two groups also were different in prevalence of gram-positive bacteria as causing organisms (ALT group 21.05 vs = 0 % in control group, p < 0.0001). There was no statistically significant difference between the two groups in drug-resistant germs. There were statistically significant differences between the two groups in the catheter removal causes, with higher rate of infectious cause in control group (12.32 vs 2.22 %, p < 0.0001) and mechanical cause in ALT group (28.26 vs 37.78 %, p < 0.0001). The results suggest that ALT may be a beneficial means of reducing the CRB rate in HD patients with tunneled catheter, without association between ALT and emergence of strains resistant. However, mechanical complications were more prevalent in antibiotic group. Further studies are required to determine the optimal drug regimen, concentrations for ALT, and its adverse effects. © 2012 Springer Science+Business Media Dordrecht.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite their propensity for significant infectious and mechanical complications, tunneled central venous catheters (CVCs) have become a common means of vascular access in the world for patients requiring chronic hemodialysis for end-stage renal disease. The objective of this study was to explore if cryopreserved solutions of the thrombolytic agent alteplase could be used as an effective, safe, and economically reasonable alternative in hemodialysis patients with occluded tunneled CVC. Patients requiring chronic hemodialysis and presenting with occluded tunneled CVC received a sufficient volume of the alteplase solution to fill the occluded catheter. To make alteplase economically feasible, it was diluted to 1-mg/mL aliquots and they were stored at -20 degrees C until use. Eighty-one patients accounting for 179 attempted clearances were assessable for efficacy. One hundred forty-seven (82.1%) of the 179 catheter clearance attempts resulted in successful catheter clearance after one dose. Twenty-seven (15.1%) of all occluded CVCs were successful after two doses whereas five (2.8%) were not. No adverse events were reported. Cryopreserved 1-mg/mL aliquots of alteplase are safe and effective in the clearance of occluded CVC for hemodialysis patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Vascular access is the major risk factor for bacteremia, hospitalization, and mortality among hemodialysis (HD) patients. The type of vascular access most associated with bloodstream infection is central venous catheter (CVC). The incidence of catheter-related bacteremia ranges between 0.6 and 6.5 episodes per 1000 catheter days and increases linearly with the duration of catheter use. Given the high prevalence of CVC use and its direct association with catheter-related bacteremia, which adversely impacts morbidity and mortality rates and costs among HD patients, several prevention measures aimed at reducing the rates of CVC-related infections have been proposed and implemented. As a result, a large number of clinical trials, systematic reviews, and meta-analyses have been conducted in order to assess the effectiveness, clinical applicability, and long-term adverse effects of such measures. In the following article, prophylactic measures against CVC-related infections in HD patients and their possible advantages and limitations will be discussed, and the more recent literature on clinical experience with prophylactic antimicrobial lock therapy in HD CVCs will be reviewed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thrombosis of tunneled central venous catheters (CVC) in hemodialysis (HD) patients is common and it can lead to the elimination of vascular sites. This study aimed to evaluate the incidence of thrombotic obstruction of tunneled CVC in HD patients and the efficacy of occlusion treatment with alteplase use, and identify factors associated with thrombotic occlusion. It was a prospective cohort study performed in two centers which evaluated the diagnosis and treatment of thrombotic occlusion of CVC in HD patients for 24 consecutive months. The catheter occlusion was defined as the difficulty infusing or withdrawing fluid from their paths. Alteplase dose was infused to fill the lumen of the occluded catheter and remained for 50 min. As there was no obstruction of the catheter, the procedure was repeated. Three hundred and thirty-nine CVC in 247 patients were evaluated and followed, totalling 67 244 CVC-days. One hundred fifty-seven patients had only one CVC, 88 patients had two CVC during the study, and two patients had three CVC. The median age was 58 (47–66) years, patients were predominantly men (54%), with diabetic nephropathy as the main cause of chronic kidney disease (44%), the internal jugular vein as the main site of implantation (82%), and duration of dialysis before CVC implantation of 119 (41.5 to 585.5) days. Eight hundred and fifteen occlusion episodes were diagnosed (12 episodes/1000 CVC-days), with primary success with alteplase in 596 episodes (77%) and secondary in 81 cases (10%). In 99 episodes (13%), success was not achieved after the second dose of alteplase. Two hundred and thirty CVC were removed during the study and the removal causes were arteriovenous fistula use in 88 patients (38.3%), infectious and mechanical complications in 89 (38.7%) and 21 (9.1%), respectively, and others (transplantation, transfer, or death) in 32 patients (13.9%). Adverse effects were also not observed. In the multivariate analysis, we identified the greatest number of days with CVC (OR = 1.02, CI = 1.01–1.04, P = 0.004), the presence of diabetes (OR = 1.560, CI = 1.351–1.894, P = 0.015), and exit site infection (ESI) (OR = 1.567 CI = 1347–1926, P = 0.023) as factors associated with obstruction. Thrombotic occlusion showed frequent mechanical complication in CVC of HD patients. We observed 12 episodes of obstruction per 1000 CVC-days, with a high success rate after alteplase use (87%). In the multivariate analysis, the time with CVC, the presence of diabetes, and ESI were identified as variables associated with thrombotic obstruction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A pilot study was conducted to compare gauze with silicone foam that may be left in place for as long as seven days. Adult patients who were receiving treatment via peripherally inserted central catheters were recruited and alternately assigned to either the gauze or silicone foam group. Patient-reported itch and discomfort, nurse-reported ease of removal, and skin status were recorded for four weeks at each weekly dressing change.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: to compare the performance of undergraduate students concerning semi-implanted central venous catheter dressing in a simulator, with the assistance of a tutor or of a self-learning tutorial. Method: Randomized controlled trial. The sample consisted of 35 undergraduate nursing students, who were divided into two groups after attending an open dialogue presentation class and watching a video. One group undertook the procedure practice with a tutor and the other with the assistance of a self-learning tutorial. Results: in relation to cognitive knowledge, the two groups had lower performance in the pre-test than in the post-test. The group that received assistance from a tutor performed better in the practical assessment. Conclusion: the simulation undertaken with the assistance of a tutor showed to be the most effective learning strategy when compared to the simulation using a self-learning tutorial. Advances in nursing simulation technology are of upmost importance and the role of the tutor in the learning process should be highlighted, taking into consideration the role this professional plays in knowledge acquisition and in the development of critical-reflexive thoughts and attitudes. (ClinicalTrials.gov Identifier: NCT 01614314).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Choosing an appropriately sized vein reduces the risk of venous thromboembolism associated with peripherally inserted central catheters. This observational study described the diameters of the brachial, basilic, and cephalic veins and determined the effect of patient factors on vein size. Ultrasound was used to measure the veins of 176 participants. Vein diameter was similar in both arms regardless of hand dominance and side. Patient factors-including greater age, height, and weight, as well as male gender-were associated with increased vein diameter. The basilic vein tended to have the largest diameter statistically. However, this was the case in only 55% of patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Peripherally inserted central catheters (PICCs) are a common vascular access device used in clinical practice. Their use may be complicated by adverse events such as venous thromboembolism (VTE). The size of the vein used for PICC insertion and thus the catheter to vein ratio is thought to be a controllable factor in the reduction of VTE rates in patients who have a PICC. However, an optimal catheter to vein ratio for PICC insertion has not previously been investigated to inform clinical practice. OBJECTIVES: To determine the effect of the catheter to vein ratio (proportion of the vein measured at the insertion point taken up by the catheter) on rates of symptomatic VTE in patients with a PICC and identify the optimal ratio cut-off point to reduce rates of this adverse event. METHOD: Adult patients waiting for PICC insertion at a large metropolitan teaching hospital were recruited between May and December 2013. Vein diameter at the PICC insertion site was measured using ultrasound with in-built callipers. Participants were followed up at eight weeks to determine if they developed symptomatic VTE. RESULTS: Data were available for 136 patients (50% cancer; 44% infection; 6% other indication for PICC). Mean age was 57 years with 54% males. There were four cases of confirmed symptomatic VTE (two involving the deep veins, one peripheral vein and one pulmonary embolism). Receiver operator characteristic (ROC) analysis determined that a 45% catheter to vein ratio was the ideal cut off point to maximise sensitivity and specificity (AUC 0.761; 95% CI 0.681-0.830). When a ratio of 46% or above was compared to one that was less than or equal to 45% using a log binomial generalised linear model it was found that participants with a catheter to vein ratio >45% were 13 times more likely to suffer VTE (relative risk 13, p=0.022; CI 1.445-122.788). CONCLUSION: It was found that a 45% catheter to vein ratio was the optimal cut off with high sensitivity and specificity to reduce the risk of VTE. However, further research is needed to confirm these results as although adequately powered; the number of cases of VTE was comparatively small, resulting in wide confidence intervals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

UNLABELLED: Abstract Aim: To investigate the patient experience of Peripherally Inserted Central Catheter (PICC) insertion, the significance of arm choice and the impact of the device on activities of daily living. BACKGROUND: Arm choice for PICC insertion is often determined by PICC nurses with little input from consumers. There are few studies that have investigated the patient experience of living with a PICC and none that have examined the impact of arm choice from the consumer's perspective. METHOD: Participants were recruited in a hospital whilst they waited for PICC insertion. A purposeful sampling approach was used to select participants based on diagnosis types. Semi-structured telephone interviews were conducted November 2012-August 2013. Transcripts of the interviews were analysed using thematic analysis. FINDINGS: Ten participants were interviewed. Four themes were identified: (i) apprehension/adaptation/acceptance, (ii) impact of treatment, (iii) asking questions (trusting doctors) and (iv) freedom. Although initially apprehensive, participants adapted to the PICC and came to accept that the device allowed convenient access for treatment. This allowed them the freedom to receive treatment at home. The use of the dominant or non-dominant arm for PICC insertion had marginal impact on activities of daily living for participants. Auxiliary factors such as the infusion pump had a significant impact for those who received outpatient treatment. For those participants who did not understand the procedure, many did not seek clarification and trusted medical and nursing staff to make decisions for them. CONCLUSION: Nurses should involve consumers in clinical decision-making and provide individualised information and support that facilitates adaptation for patients living with a PICC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Peripherally inserted central catheters (PICCs) are increasingly inserted by trained registered nurses, necessitating the development of specialized skills such as the use of ultrasound. The selection of an adequately sized vein is an important factor in reducing adverse events such as deep vein thrombosis. However, PICC nurses may receive minimal training in the use of ultrasound for vein measurement. Objective We aimed to demonstrate the reliability of a vein measurement protocol using ultrasound by a PICC nurse trained in sonography. Methods The diameter of the basilic, brachial, and cephalic veins in the left arms of healthy participants (n = 12) were measured using ultrasound by a PICC nurse and a sonographer. A PICC nurse performed the measurement twice and the sonographer once; the PICC nurse's results were compared for intra-rater reliability and compared with the sonographer for inter-rater reliability. The results were analyzed using intraclass correlation coefficients (ICCs). Results Inter-rater reliability between the PICC nurse and the sonographer was adequate, the ICC for the brachial vein was 0.60 (95% confidence interval [CI], 0.06-0.87), basilic vein ICC was 0.87 (95% CI, 0.58-0.96) and cephalic vein ICC was 0.77 (95% CI, 0.39-0.93). Intra-rater reliability of the PICC nurse was higher; the ICC for the brachial vein was 0.80 (95% CI, 0.44-0.94), basilic vein ICC was 0.92 (95% CI, 0.67-0.98), and cephalic vein ICC was 0.78 (95% CI, 0.40-0.93). Conclusions Using a suitable protocol, a PICC nurse was able to measure vein diameter reliably when compared with a sonographer and consistently replicate these results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La trombosis relacionada al uso del catéter es un problema que cobra cada vez mayor importancia. Se han descrito factores de riesgo para su presentación en la población pediátrica pero aún no se han realizado estudios en nuestro medio. Objetivo: Determinar los factores de riesgo y la prevalencia de la trombosis asociada a catéter venoso central en los pacientes pediátricos de la Fundación Cardioinfantil hospitalizados durante el periodo comprendido entre Julio 2013 a Julio 2015. Metodología: Se realizó un estudio de corte transversal de asociación. Se incluyeron pacientes clasificados en 4 grupos: trombosis y catéter, trombosis sin catéter, catéter sin trombosis y sin trombosis ni catéter. Se estimaron OR como medidas de asociación utilizando el estadístico mantel haenszel. Resultados: En total se incluyeron 221 pacientes. La prevalencia de la trombosis y uso del catéter fue del 22%. La edad inferior a los 36 meses (OR 2,27 IC95% 1,16-4,44,p<0.001), profilaxis antitrombótica (OR 34,4 IC95% 4,18-282,92, p<0.01), hospitalización en la UCI (OR 3,82, IC95% 1,69-8,65, p<0.001) y el tiempo de hospitalización (OR 16,83 IC95% 7,8-36,27, p<0.001) están asociadas con un mayor riesgo de presentación de la trombosis. Conclusión: La edad, hospitalización en UCI, uso de profilaxis antitrombótica y el tiempo de hospitalización son factores de riesgo que estan relacionados con la presentación de la trombosis en pacientes con cateter.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Esta pesquisa teve como objeto de estudo a segurança do recém-nascido no processo de utilização do Cateter Central de Inserção Periférica (PICC) e, como objetivos: conhecer o significado de segurança para o enfermeiro no processo de utilização do PICC em recém-nascidos; descrever os cuidados prestados pelo enfermeiro no uso do PICC em recém-nascidos e analisar os nexos entre segurança e os princípios bioéticos no uso do PICC em recém-nascidos na prática assistencial dos enfermeiros. Trata-se de um estudo descritivo de abordagem qualitativa. O cenário foi a unidade de terapia intensiva neonatal de um Hospital Universitário localizado no município do Rio de Janeiro e os sujeitos, 11 enfermeiros plantonistas capacitados e que realizam a implantação do PICC em recém-nascidos. Para a coleta de dados realizou-se a entrevista semiestruturada, gravada em fita cassete, entre os meses de março e junho de 2012. Posteriormente estas foram transcritas e analisadas por meio da análise de conteúdo de Bardin, na modalidade temática e interpretada à luz dos princípios bioéticos e da segurança do paciente. Como resultados emergiram 04 categorias: Técnicas e Procedimentos, Cuidados com o recém-nascido, Aspectos relacionados à equipe e Aspectos relacionados à família. Para os enfermeiros, segurança no processo de utilização do PICC no recém-nascido, significa saber indicar o uso deste dispositivo de acordo com as peculiaridades de cada criança. Exercer cuidados antes, durante e após o uso do cateter, valorizar os cuidados técnicos relacionados ao procedimento, possuir conhecimento teórico-prático e ter disponibilidade de recursos materiais e humanos para desenvolver um cuidado seguro. Além de atentar para os registros e protocolos da unidade acerca desta prática assistencial. Para preservar a segurança do neonato, compreendem ser necessária a tomada de decisão em conjunto com o médico acerca do momento ideal para se implantar este dispositivo, bem como a escolha do tipo ideal de sedação para o mesmo, dentre outros aspectos. No processo de utilização do PICC, os enfermeiros entendem a manutenção da temperatura corporal, a realização de medidas de conforto perante a dor, a prevenção de infecções e o posicionamento adequado do recém-nascido durante o procedimento, como atitudes essenciais para a promoção de sua segurança. Buscam, também, esclarecer os pais quanto ao procedimento que será realizado com seu filho. Conclui-se que o enfermeiro, no que diz respeito à prática do PICC, atua de acordo com os princípios bioéticos de beneficência e não-maleficência, já que realiza sua assistência visando o bem-estar do neonato, procurando minimizar os desconfortos associados a esse procedimento. Apesar de esclarecerem os pais quanto ao procedimento que será realizado com seu filho, alguns enfermeiros, não os consultam previamente acerca da autorização para implantação deste dispositivo infringindo, assim, o princípio bioético da autonomia.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Access-related bacteremia is an important cause of morbidity in chronic hemodialysis patients. The incidence of bacteremia is higher in patients dialyzing through a tunneled central venous catheter (TCVC) compared with an arteriovenous fistula (AVF). Our aim was to explore if this is explained by patient comorbidity. Two groups of chronic hemodialysis outpatients were compared: all patients who dialyzed through a TCVC at any time during 2003 and were fit enough to subsequently have a functioning AVF or renal transplant even if it was after 2003 (Group 1; n=93); and all patients who dialyzed through a TCVC in 2003 and were not fit enough to have a functioning AVF or renal transplant (Group 2; n=119). Episodes of bacteremia (n=71) were identified and those not related to access were excluded. Patients in Group 1 were younger than Group 2 (57.5 years vs. 64.8 years; P=0.001). The incidences of bacteremia in Groups 1 and 2 were, respectively, 0.31 and 0.44 episodes per 1000 patient days while dialyzing through an AVF (P=0.77), and 2.21 and 2.27 per 1000 days while dialyzing through a TCVC (P=0.91). The 3-year actual survival from January 1, 2003 to January 1, 2006 was significantly higher in Group 1 than in Group 2 (80.6% vs. 26.1%; P<0.0001) confirming the higher comorbidity of the patients in Group 2. Patients dialyzing through a TCVC (compared with an AVF) have a significantly higher risk of access-related bacteremia, irrespective of comorbidity.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nous avons mené une étude prospective randomisée dans le but de comparer l'effet de l'irrigation du cathéter de type PICC avec deux types d'anticoagulants: Héparine standard et Tinzaparine, une héparine de faible poids moléculaire. Notre étude s'adresse aux patients de la clinique externe d'oncologie de l'hôpital Maisonneuve-Rosemont. Entre début Mai 2005 et Mars 2008, nous avons recruté 131 patients dont 70 ont été randomisés. Parmi les 61 patients exclus, 23 n'ont pas rencontré les critères d'inclusion, 30 ont refusé de participer et 8 ne sont pas inclus pour d'autres raisons. Sur les 70, 36 sujets sont randomisés dans le groupe Héparine standard et 34 dans le groupe Tinzaparine. La population en intention de traiter comprend 65 sujets dont 32 dans le groupe Héparine standard et 33 dans le groupe Tinzaparine. Le médicament a été administré pendant un mombre maximal de 30 jours et les sujets ont été suivis pendant 90 jours. La thrombose veineuse associée au cathéter (TVAC) a été objectivée par une phlébographie ou une échographie-Doppler à la fin de la période de 30 jours suivant l'installation du cathéter. L'incidence de la TVAC sur 30 jours est de 14,39 par 1000 cathéter-jours (IC à 95%:[9,0;19,79]/1000 cathéter-jours ou 41,5% (27/65). L'incidence de la thrombose veineuse profonde (TVP) symptômatique du membre supérieur sur la période de suivi de 90 jours est de 0,41 par 1000 cathéter-jours (IC à 95%:[0,08;0,81]/1000 cathéter-jours ou 3% (2/65). Nous n'avons observé aucune différence entre les deux groupes par rapport à la fréquence de la TVAC ni de la TVP. Nous ne pouvons conclure à une différence dans l'efficacité de la Tinzaparine par rapport à l'Héparine standard dans la prévention de la TVAC.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Fisiopatologia em Clínica Médica - FMB