989 resultados para Tubular Steel Member
Resumo:
Tubular members have become progressively more popular due to excellent structural properties, aesthetic appearance, corrosion and fire protection capability. However, a large number of such structures are found structurally deficient due to reduction of strength when they expose to severe environmental conditions such as marine environment, cold and hot weather. Hence strengthening and retrofitting of structural members are in high demands. In recent times Carbon Fibre Reinforced Polymers (CFRP) composites appears to be an excellent solution to enhance the load carrying capacity and serviceability of steel structures because of its superior physical and mechanical properties. However, the durability of such strengthening system under cold environmental condition has not yet been well documented to guide the engineers. This paper presents the findings of a study conducted to enhance the bond durability of CFRP strengthened steel tubular members by treating steel surface using epoxy based adhesion promoter under cold weather subjected to bending. The experimental program consisted of six number of CFRP strengthened specimens and one bare specimen. The sand blasted surface of the three specimens to be strengthened was pre-treated with MBrace primer and other three were remained untreated and then cured under ambient temperature and cold weather (3oC) for three and six months period of time. The beams were then loaded to failure under four point bending. The structural response of each specimen was predicted in terms of failure mode, failure load and mid-span deflection. The research findings show that the cold weather immersion had an adverse effect on durability of CFRP strengthened structures. Moreover, the epoxy based adhesion promoter was found to enhance the bond durability in elastic range.
Resumo:
The use of circular hollow steel members has attracted a great deal of attention during past few years because of having excellent structural properties, aesthetic appearance, corrosion and fire protection capability. However, no one can deny the structural deficiency of such structures due to reduction of strength when they are exposed to severe environmental conditions such as marine environment, cold and hot weather. Hence strengthening and retrofitting of structural steel members is now very imperative. This paper presents the findings of a research program that was conducted to study the bond durability of carbon fibre-reinforced polymer (CFRP) strengthened steel tubular members under cold weather and tested under four-point bending. Six number of CFRP-strengthened specimens and one unstrengthened specimen were considered in this program. The three specimens having sand blasted surface to be strengthened was pre-treated with MBrace primer and other three were remained untreated and then cured under ambient temperature at least four weeks and cold weather (3 C) for three and six months period of time. Quasi-static tests were then performed on beams to failure under four-point bending. The structural response of each specimen was predicted in terms of failure load, mid-span deflection, composite beam behaviour and failure mode. The research outcomes show that the cold weather immersion had an adverse effect on durability of CFRP-strengthened steel structures. Moreover, the epoxy based adhesion promoter was found to enhance the bond durability in plastic range. The analytical models presented in this study were found to be in good agreement in terms of predicting ultimate load and deflection. Finally, design factors are proposed to address the short-terms durability performance under cold weather.
Resumo:
In strengthening systems, the CFRP (Carbon Fibre Reinforced Polymer) materials typically have excellent resistance against environmental conditions; however, the performance of adhesives between CFRP and steel is generally affected by various environmental conditions such as marine environment, cold and hot weather. This paper presents the comparative durability study of CFRP strengthened tubular steel structures by using two different adhesives such as MBrace saturant and Araldite K630 under four-point bending. The program consisted of testing twelve CFRP strengthened specimens having treated with epoxy based adhesion promoter, untreated surface and one unstrengthened specimen and conditioned under cold weather for 3 and 6 months to determine the environmental durability. The beams were then loaded to failure in quasi-static manner under four-point bending. The structural responses of CFRP strengthened tubular steel beams were compared in terms of failure load, stiffness and modes of failure. The research findings show that the cold weather immersion had adversely affected the durability of CFRP strengthened steel members. Design factor is also proposed to address the short-terms durability performance under cold weather.
Resumo:
This paper reveals the effects of layer orientation on structural behaviour of three layers configured (LHL, HHL, LLH) CFRP strengthened circular hollow section (CHS) members subjected to bending. The beams were loaded to failure under four-point bending. The structural behaviour of the CFRP strengthened tubular steel beams with various layer orientations were presented in terms of failure load, stiffness, composite beam action and modes of failure. The LHL and LLH layers oriented strengthened beams perform slightly better than HHL layers oriented strengthened beams. The LHL and LLH layers oriented treated beams showed very similar structural behaviour.
Resumo:
Cold-formed tubular sections are widely used in many modern steel structures. Two innovative cold-formed sections have been introduced to the Australian building industry. They are the 'in-line' galvanized rectangular hollow section (RHS) tubes and the hollow flange beams (HFB). They offer significant advantages but at the same time provide challenges to designers because of their special characteristics. The application, manufacturing, advantages and characteristics of these two sections are described.
Resumo:
This paper presents an accurate and robust geometric and material nonlinear formulation to predict structural behaviour of unprotected steel members at elevated temperatures. A fire analysis including large displacement effects for frame structures is presented. This finite element formulation of beam-column elements is based on the plastic hinge approach to model the elasto-plastic strain-hardening material behaviour. The Newton-Raphson method allowing for the thermal-time dependent effect was employed for the solution of the non-linear governing equations for large deflection in thermal history. A combined incremental and total formulation for determining member resistance is employed in this nonlinear solution procedure for the efficient modeling of nonlinear effects. Degradation of material strength with increasing temperature is simulated by a set of temperature-stress-strain curves according to both ECCS and BS5950 Part 8, which implicitly allows for creep deformation. The effects of uniform or non-uniform temperature distribution over the section of the structural steel member are also considered. Several numerical and experimental verifications are presented.
Resumo:
A numerical procedure based on the plastic hinge concept for study of the structural behaviour of steel framed structures exposed to fire is described. Most previous research on fire analysis considered the structural performance due to rising temperature. When strain reversal occurs during the cooling phase, the stress–strain curve is different. The plastic deformation is incorporated into the stress–strain curve to model the strain reversal effect in which unloading under elastic behaviour is allowed. This unloading response is traced by the incremental–iterative Newton–Raphson method. The mechanical properties of the steel member in the present fire analysis follows both Eurocode 3 Part 1.2 and BS5950 Part 8, which implicitly allow for thermal creep deformation. This paper presents an efficient fire analysis procedure for predicting thermal and cooling effects on an isolated element and a multi-storey frame. Several numerical and experimental examples related to structural behaviour in cooling phase are studied and compared with results obtained by other researchers. The proposed method is effective in the fire safety design and analysis of a building in a real fire scenario. The scope of investigation is of great significance since a large number of rescuers would normally enter a fire site as soon as the fire is extinguished and during the cooling phase, so a structural collapse can be catastrophic.
Resumo:
Tapered tubular steel masts are commonly used to support floodlights in a range of applications. The design of these slender tapered masts requires a rational elastic flexural buckling analysis as the thickness also varies with height. Therefore a series of finite element analyses of tapered masts with varying geometry parameters was conducted to develop an elastic flexural buckling load formula. This paper briefly discusses the design methods, and then presents the details of the finite element analyses and the results. 1–Associate Professor of Civil Engineering, and Director, Physical Infrastructure Centre 2–Former BE (Civil) Student, QUT
Resumo:
Este trabalho de pesquisa apresenta como objetivo principal o desenvolvimento de investigação experimental dinâmica sobre estrutura real de uma passarela tubular mista aço-concreto. O sistema estrutural objeto deste trabalho corresponde a uma passarela composta por três vãos (32,5m, 17,5m e 20,0m, respectivamente) e dois balanços (7,50m e 5,0m, respectivamente), com comprimento total de 82,5m. A passarela com estrutura contínua de aço com as ligações soldadas se apoia em quatro pórticos também de aço. Estruturalmente está constituída por duas treliças planas que se interligam através de contraventamentos horizontais fixados na corda superior e inferior da treliça e lajes de concreto, formando um sistema misto com interação completa. A estrutura está submetida correntemente à travessia de pedestres e ciclistas. Testes experimentais foram realizados sobre o sistema estrutural e confrontados com resultados numéricos. Para a modelagem numérica do sistema são empregadas técnicas usuais de discretização, via método dos elementos finitos (MEF), por meio do programa ANSYS. Os resultados experimentais são analisados de acordo com a metodologia desenvolvida, sendo realizada análise modal experimental para a determinação das propriedades dinâmicas: freqüências, modos e taxa de amortecimento, enquanto que os resultados da estrutura, em termos de aceleração de pico, são comparados com os valores limites propostos por diversos autores, normas e recomendações de projeto, para uma avaliação do desempenho da estrutura em relação a vibração quando solicitada pelo caminhar dos pedestres no que diz respeito a critério para conforto humano.
Resumo:
A experiência dos engenheiros estruturais e os conhecimentos adquiridos pelo uso de materiais e novas tecnologias, têm ocasionado estruturas de aço e mistas (aço-concreto) de passarelas cada vez mais ousadas. Este fato tem gerado estruturas de passarelas esbeltas, e consequentemente, alterando os seus estados de limite de serviço e último associados ao seu projeto. Uma consequência direta desta tendência de projeto é o aumento considerável das vibrações das estruturas. Portanto, a presente investigação foi realizada com base em um modelo de carregamento mais realista, desenvolvido para incorporar os efeitos dinâmicos induzidos pela caminhada de pessoas. O modelo de carregamento considera a subida e a descida da massa efetiva do corpo em cada passo. A posição da carga dinâmica também foi alterada de acordo com a posição do pedestre sobre a estrutura e a função do tempo gerada, possui uma variação espacial e temporal. O efeito do calcanhar do pedestre também foi incorporado na análise. O modelo estrutural investigado baseia-se em uma passarela tubular (aço-concreto), medindo 82,5m. A estrutura é composta por três vãos (32,5 m, 20,0 m e 17,5 m, respectivamente) e dois balanços (7,5 m e 5,0 m, respectivamente). O sistema estrutural é constituído por perfis de aço tubular e uma laje de concreto, e é atualmente utilizada para travessia de pedestres. Esta investigação é realizada com base em resultados experimentais, relacionando a resposta dinâmica da passarela com as obtidas via modelos de elementos finitos. O modelo computacional proposto adota as técnicas de refinamento de malha, usualmente presente em simulações pelo método de elementos finitos. O modelo de elementos finitos foi desenvolvido e validado com resultados experimentais. Este modelo de passarela tubular permitiu uma avaliação dinâmica completa, investigando especialmente ao conforto humano e seus limites de utilização associados à vibração. A resposta dinâmica do sistema, em termos de acelerações de pico, foi obtida e comparada com os valores limites propostos por diversos autores e padrões de projeto. As acelerações de pico encontradas na presente análise indicou que a passarela tubular investigada apresentou problemas relacionados com o conforto humano. Por isso, foi detectado que este tipo de estrutura pode atingir níveis de vibrações excessivas que podem comprometer o conforto do usuário na passarela e especialmente a sua segurança.
Resumo:
Previous research into the behaviour of piled foundations in laterally-spreading soil deposits has concentrated on pile groups that carry small or negligible axial loads. This paper presents dynamic centrifuge test results for 2 x 2 pile groups with bending and geometric properties similar to real 0.5 m diameter tubular steel and solid circular reinforced-concrete field piles. Axial loads applied represented upper-bounds on typical working loads. The simultaneous scaling of the relevant properties controlling both lateral and axial behaviour allows comparisons to be drawn regarding the particular mechanisms of failure that would dominate for each type of pile. Flexible reinforced-concrete piles which tend to carry lower loads were found to be dominated by lateral effects, while steel piles, which are much stiffer and usually carry greater loads are dominated by settlement considerations. © 2006 Taylor & Francis Group.
Resumo:
Previous research into the behaviour of piled foundations in laterally-spreading soil deposits has concentrated on pile groups that carry small or negligible axial loads. This paper presents dynamic centrifuge test results for 2×2 pile groups with bending and geometric properties similar to real 0.5m diameter tubular steel and solid circular reinforced-concrete field piles. Axial loads applied represented upper-bounds on typical working loads. The simultaneous scaling of the relevant properties controlling both lateral and axial behaviour allows comparisons to be drawn regarding the particular mechanisms of failure that would dominate for each type of pile. Flexible reinforced-concrete piles which tend to carry lower loads were found to be dominated by lateral effects, while steel piles, which are much stiffer and usually carry greater loads are dominated by settlement considerations. © 2006 Taylor & Francis Group, London.
Resumo:
Since Ranzini suggested supplementing the SPT test with measurement of the torque required to turn the split spoon sampler after driving, many Brazilian engineers have been using this in the design of pile foundations. This paper presents a study of the rod length influence in the torque measurement. A theoretical study of material resistance considering torsion and bending in a thin wall tubular steel shaft was performed. It makes possible to conclude that the shearing tension caused by the proper weight represents less than 1% of the shearing tension caused by the turning moment. In addition, an experimental study was done with electric torquemeters fixed in a horizontal rod system. The tests were being carried out to analyze rods of one meter to twenty meters in length and the measurements were collected at the ends of each rod length verifying the efficiency data. As a result, it is possible to verify that the torque difference through rod length is lower than minimum scales of mechanical torquemeters that are used on practical engineering. Also a fact to be considered is a big torque loss for values under 20 N.m of applied torque. This way, the SPT-T is not adequate to low consistency soil. Copyright ASCE 2007.
Resumo:
Lo studio svolto in merito alle tecniche di produzione di componenti strutturali in materiale composito ha permesso il raggiungimento di una precisa consapevolezza dello stato dell’arte del settore, in particolare in riferimento ai processi attualmente utilizzati per l’industrializzazione in media-grande serie. Con l’obiettivo di sintetizzare i principali vantaggi delle tecnologie suddette e permettere la realizzazione di forme più complesse, si è proceduto all’analisi di fattibilità, attraverso uno studio funzionale e una prima progettazione di una tecnologia di produzione per nastratura automatizzata di componenti strutturali in materiale composito. Si è voluto quindi dimostrare la flessibilità e la consistenza del processo disegnando un telaio nastrato in carbonio, intercambiabile al telaio FSAE 2009 in tubolare d’acciaio (stessi punti di attacco motore, punti di attacco telaietto posteriore, attacchi sospensioni anteriori) e che garantisca un sostanziale vantaggio in termini di peso, a pari rigidezza torsionale. La caratterizzazione di tale telaio è stata eseguita mediante l'utilizzo del calcolo strutturale, validato da prove sperimentali.