859 resultados para Tromboembolismo arterial


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Clinical manifestations of arterial thromboembolism in cats depends on the location of embolization, the severity and duration of occlusion, the functionality of the collateral circulation and the development of complications. In case of location in the terminal abdominal aorta usually presents animal paresis/paralysis, pulses are weak or nonpalpable, pain, cold limbs. Gastrocnemius and tibialis muscles generally have become bulbous, swollen and sore because of ischemic neuromyopathy. The nail beds become pale or very dark (purple to black), and do not bleed when cut. Due to the small number of researches in the area it’s until not possible to determine which medication, dosage and frequency of administration are more suitable for the treatment of arterial thromboembolism in cats. Among the options currently available the cheapest, easiest to administer and which requires no periodic monitoring is the low-dose aspirin

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este relatório foi elaborado no âmbito do estágio curricular do Mestrado Integrado em Medicina Veterinária. Encontra-se dividido em duas partes. Na primeira parte é feita uma análise da casuística seguida durante o estágio. A segunda parte é constituída por uma monografia de revisão bibliográfica sobre o tema ”Tromboembolismo Arterial Felino”(TAF), bem como a descrição e discussão de dois casos clínicos acompanhados durante o estágio. O TAF é caracterizado pela embolização de um trombo numa artéria da circulação sistémica, sendo a localização mais frequente a trifurcação ilíaca da artéria aorta. Na maioria dos casos, o trombo tem origem no átrio esquerdo, como resultado de cardiomiopatia. Apesar do diagnóstico ser facilmente obtido através de sinais clínicos, o tratamento e a prevenção desta afeção representam um desafio para o médico veterinário, já que a taxa de reincidência de tromboembolismo e mortalidade são elevadas, projectando um prognóstico reservado; Clinic and Surgery of Small Animals Abstract: This report was done within the scope of the internship integrated master’s degree in Veterinay Medicine. It is divided in two parts. In the first part, an analisys of the casuistic followed during the internship is done. The second part is composed by a literature review about the theme ”Feline Arterial Thromboembolism”(FAT), as well as the description and discussion of two clinical cases followed during the internship. FAT is characterized by the embolization of a thrombus in a artery of systemic circulation, being its location more frequently in iliac trifurcation of aorta artery. On most of the cases the thrombus has its origins on the left atrium, as a result of cardiomyopathy. Besides the diagnosis being easily obtained through clinical signs, the treatment and prevention of this disease represents a challenge to the veterinarian clinician, due to the FAT recurrance rate and high mortality, projecting a pour/reserved prognosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ticagrelor is an orally active ADP P2Y12 receptor antagonist in development by AstraZeneca plc for the reduction of recurrent ischemic events in patients with acute coronary syndromes (ACS). Prior to the development of ticagrelor, thienopyridine compounds, such as clopidogrel, were the focus of research into therapies for ACS. Although the thienopyridines are effective platelet aggregation inhibitors, they are prodrugs and, consequently, exert a slow onset of action. In addition, the variability in inter-individual metabolism of thienopyridine prodrugs has been associated with reduced efficacy in some patients. Ticagrelor is not a prodrug and exhibits a more rapid onset of action than the thienopyridine prodrugs. In clinical trials conducted to date, ticagrelor was a potent inhibitor of ADP-induced platelet aggregation and demonstrated effects that were comparable to clopidogrel. In a phase II, short-term trial, the bleeding profile of participants treated with ticagrelor was similar to that obtained with clopidogrel; however, an increased incidence of dyspnea was observed - an effect that has not been reported with the thienopyridines. Considering the occurrence of dyspnea, and the apparent non-superiority of ticagrelor to clopidogrel, it is difficult to justify a clear benefit to the continued development of ticagrelor. Outcomes from an ongoing phase III trial comparing ticagrelor with clopidogrel in 18,000 patients with ACS are likely to impact on the future development of ticagrelor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate whether venous occlusion plethysmography (VOP) may be used to measure high rates of arterial inflow associated with exercise, venous occlusions were performed at rest, and following dynamic handgrip exercise at 15, 30, 45, and 60 % of maximum voluntary contraction (MVC) in seven healthy males. The effect of including more than one cardiac cycle in the calculation of blood flow was assessed by comparing the cumulative blood flow over one, two, three, or four cardiac cycles. The inclusion of more than one cardiac cycle at 30 and 60 % MVC, and more than two cardiac cycles at 15 and 45 % MVC resulted in a lower blood flow compared to using only the first cardiac cycle (P < 0.05). Despite the small time interval over which arterial inflow was measured (~1 second), this did not affect the reproducibility of the technique. Reproducibility (coefficient of variation for arterial inflow over three trials) tended to be poorer at the higher workloads, although this was not significant (12.7 ± 6.6 %, 16.2 ± 7.3 %, and 22.9 ± 9.9 % for the 15, 30, and 45 % MVC workloads; P=0.102). There was also a tendency for greater reproducibility with the inclusion of more cardiac cycles at the highest workload, but this did not reach significance (P=0.070). In conclusion, when calculated over the first cardiac cycle only during venous occlusion, high rates of FBF can be measured using VOP, and this can be achieved without a significant decrease in the reproducibility of the measurement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to assess the potential use of Bluetooth data for traffic monitoring of arterial road networks. Bluetooth data provides the direct measurement of travel time between pairs of scanners, and intensive research has been reported on this topic. Bluetooth data includes “Duration” data, which represents the time spent by Bluetooth devices to pass through the detection range of Bluetooth scanners. If the scanners are located at signalised intersections, this Duration can be related to intersection performance, and hence represents valuable information for traffic monitoring. However the use of Duration has been ignored in previous analyses. In this study, the Duration data as well as travel time data is analysed to capture the traffic condition of a main arterial route in Brisbane. The data consists of one week of Bluetooth data provided by Brisbane City Council. As well, micro simulation analysis is conducted to further investigate the properties of Duration. The results reveal characteristics of Duration, and address future research needs to utilise this valuable data source.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Travel time is an important network performance measure and it quantifies congestion in a manner easily understood by all transport users. In urban networks, travel time estimation is challenging due to number of reasons such as, fluctuations in traffic flow due to traffic signals, significant flow to/from mid link sinks/sources, etc. The classical analytical procedure utilizes cumulative plots at upstream and downstream locations for estimating travel time between the two locations. In this paper, we discuss about the issues and challenges with classical analytical procedure such as its vulnerability to non conservation of flow between the two locations. The complexity with respect to exit movement specific travel time is discussed. Recently, we have developed a methodology utilising classical procedure to estimate average travel time and its statistic on urban links (Bhaskar, Chung et al. 2010). Where, detector, signal and probe vehicle data is fused. In this paper we extend the methodology for route travel time estimation and test its performance using simulation. The originality is defining cumulative plots for each exit turning movement utilising historical database which is self updated after each estimation. The performance is also compared with a method solely based on probe (Probe-only). The performance of the proposed methodology has been found insensitive to different route flow, with average accuracy of more than 94% given a probe per estimation interval which is more than 5% increment in accuracy with respect to Probe-only method.