926 resultados para Trenbolone Acetate


Relevância:

70.00% 70.00%

Publicador:

Resumo:

A liquid chromatography-thermospray mass spectrometric assay was developed and validated to confirm the presence of illegal residues of the synthetic androgenic growth promoter, trenbolone acetate, in cattle. The assay was specific for 17alpha-trenbolone, the major bovine metabolite of trenbolone acetate. Methods were developed for the determination of 17alpha-trenbolone in both bile and faeces, the most appropriate matrices for the control of trenbolone acetate abuse. The clean-up.procedure developed relied on enzymatic hydrolysis, followed by sequential liquid-liquid and liquid-solid extraction. The extracts were then subjected to immunoaffinity chromatography. 17alpha-Trenbolone was detected by selected ion monitoring at m/z 271 using positive ion thermospray ionisation. The limit of detection was approximately 0.5 ng/g in faeces and 0.5 ng/ml in bile.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

One hundred forty-four crossbred yearling steers with an average weight of 841 pounds were used in a 116- day experiment. Steers received either 1) no implant, 2) Synovex S¨, 3) Revalor S¨, or 4) Synovex Plus¨. All implanted groups consumed more feed and gained faster and more efficiently than non-implanted steers. There were no significant differences in gain, feed intake or feed efficiency among implanted groups, though steers with the estrogen + trenbolone acetate combination implants were numerically superior to those implanted with Synovex S¨. There were no differences in feedlot performance between the two combination implants. Implants increased carcass weight with no significant effects on fat thickness or carcass quality grades. The combination implants containing trenbolone acetate increased ribeye area and increased masculinity of the carcasses. These results indicate Synovex Plus¨ is an effective implant for finishing steers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Four groups of yearling heifers representing different frame sizes—small, medium, and large Angus and medium Simmental—were fed high-grain finishing diets to average Low Choice quality grade. Half the heifers were implanted with estrogen and trenbolone acetate. Backfat and ribeye area were measured by ultrasound four times during the study to assess growth of muscle and fat. Increasing frame size resulted in increased feed intake, greater rates of gain, and a trend towards reduced feed conversion. Greater returns would have been realized from each of the four groups had they been sold in a premium market based on yield grade rather than the conventional grade and yield market. Increasing frame size resulted in greater returns to the value-based market. Implants increased rate of gain and improved feed conversion but did not result in significantly greater returns to the value-based market compared with the grade and yield market. Ribeye area and backfat increased with body weight and time on feed. Increase in ribeye area was linear with time, whereas accumulation of backfat was exponential. Rate of increase in area of ribeye tended to increase and backfat tended to decrease as frame size increased. Implants increased rate of increase in ribeye area but had no effect on rate of deposition of subcutaneous fat. Equations describing growth of ribeye area and backfat for each group predicted average growth for the heifers but did not predict growth of individual heifers. Final carcass yield grade was related to initial thickness of backfat but not to initial ribeye area. These results indicate that the type of cattle selected to be fed for a premium market based on yield grade is important to the success of the program. More work is needed to develop growth equations from ultrasound measurements, but ultrasound will likely be a useful tool in selecting feeder cattle for a value-based market.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A 106-day demonstration utilizing yearling steers to measure feedlot performance and carcass response to implant strategies was conducted at the ISU Allee Demonstration Farm. Treatments were: 100 mg progesterone + 10 mg estradiol benzoate (ComponentÒ EC) on day 0 followed by 120 mg trenbolone acetate + 24 mg estradiol (ComponentÒ TES) implant 57 days later, or 120 mg trenbolone acetate + 24 mg estradiol (ComponentÒ TES) only on day 0. The control group received no implant. The steers were weighed every 28 days and ultrasound data were collected from demonstration initiation until slaughter. The cattle were marketed as one group on d 106 of the demonstration. Implanted cattle had higher average daily gains, heavier carcass weights, larger rib eye areas, and tended to have improved feed efficiency over control steers. Additionally, the reimplanted steers had higher marbling scores than controls, but no differences existed between once and twice-implanted steers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A feedlot demonstration utilizing Encore®, a new longterm implant product, was completed at the Allee Demonstration Farm at Newell, Iowa in 1999. Seventyone steers (697 lbs.) were allotted by weight and hide color and assigned to one of three treatments: 1) Encore® (43.9 mg estradiol = E) on day 0; 2) Encore® plus Component® TS (140 mg trenbolone acetate = ETS0) on day 0; or 3) Encore® on day 0 followed by Component® TS (ETS100) on day 100. Due to wide standard deviation in the weight of steers at the beginning of the demonstration, cattle were harvested in two groups. Approximately half of each treatment group was sorted by visual appraisal as to market readiness. Statistical interactions existed within treatment group between first and second harvest dates, therefore data were split and analyzed accordingly. In the first harvest group, ETS0 steers had higher marbling scores than ETS100 steers, and lower average daily gain than E steers and ETS100 steers. In the second harvest group, ETS0 steers had more fat at the 12th/13 rib than ETS100 steers, but did not differ from E steers. Marbling scores were also higher for ETS0 steers than either ETS100 or E steers in the second harvest group. Pooled data reveal that ETS0 steers had higher marbling scores than ETS100 steers and tended to have higher marbling scores than E steers. First harvest E and ETS100 steers had greater average daily gain than ETS0 steers. In the second harvest group, ETS0 steers had heavier final ending weights than E steers but did not differ from ETS100 steers. Final ending weights, rib eye area, fat thickness at the 12th/13th rib, KPH fat, and calculated yield grades did not differ among treatment groups in the pooled data.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Six steers (3/4 Charolaisx1/4 Brahman) (mean body weight 314 +/- 27 kg) and six spayed heifers (3/5 Shorthornx2/5 Red Angus) (mean body weight 478 +/- 30 kg) were used to determine the effects of climatic conditions and hormone growth promotants (HGP) on respiration rate (RR; breaths/min), pulse rate (beats/min), rectal temperature (RT; degrees C), and heat production (HP; kJ). Cattle were exposed to the following climatic conditions prior to implantation with a HGP and then again 12 days after implantation: 2 days of thermoneutral conditions (TNL) [21.9 +/- 0.9 degrees C ambient temperature (T-A) and 61.7 +/- 22.1% relative humidity (RH)] then 2 days of hot conditions [HOT; 29.2 +/- 4 degrees C (T-A) and 78.3 +/- 13.2% (RH)], then TNL for 3 days and then 2 days of cold conditions [COLD; 17.6 +/- 0.9 degrees C (T-A) and 63.4 +/- 1.8% (RH); cattle were wet during this treatment]. The HGP implants used were: estrogenic implant (E), trenbolone acetate implant (TBA), or both (ET). Both prior to and following administration of HGP, RRs were lower (P < 0.05) on cold days and greater (P < 0.05) on hot days compared to TNL. On hot days, RTs, were 0.62 degrees C higher after compared to before implanting. Across all conditions, RTs were > 0.5 degrees C greater (P < 0.05) for E cattle than for TBA or ET cattle. On cold days, RTs of steers were > 0.8 degrees C higher than for the heifers, while under TNL and HOT, RTs of steers were 0.2-0.35 degrees C higher than those of heifers. Prior to implantation, HP per hour and per unit of metabolic body weight was higher (P < 0.05) for cattle exposed to hot conditions, when compared to HP on cold days. After implantation, HP was greater (P < 0.05) on hot days than on cold days. Under TNL, ET cattle had the lowest HP and greatest feed intake. On hot days, E cattle had the lowest HP, and the highest RT; therefore, if the potential exists for cattle death from heat episodes, the use of either TBA or ET may be preferred. Under cold conditions HP was similar among implant groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural changes in intercalated kaolinite after wet ball-milling were examined by scanning electron microscopy (SEM), X-ray diffraction (XRD), specific surface area (SSA) and Fourier Transform Infrared spectroscopy (FTIR). The X-ray diffraction pattern at room temperature indicated that the intercalation of potassium acetate into kaolinite causes an increase of the basal spacing from 0.718 to 1.42 nm, and with the particle size reduction, the surface area increased sharply with the intercalation and delamination by ball-milling. The wet ball-milling kaolinite after intercalation did not change the structural order, and the particulates have high aspect ratio according SEM images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thermal decomposition of halloysite-potassium acetate intercalation compound was investigated by thermogravimetric analysis and infrared emission spectroscopy. The X-ray diffraction patterns indicated that intercalation of potassium acetate into halloysite caused an increase of the basal spacing from 1.00 to 1.41 nm. The thermogravimetry results show that the mass losses of intercalation the compound occur in main three main steps, which correspond to (a) the loss of adsorbed water (b) the loss of coordination water and (c) the loss of potassium acetate and dehydroxylation. The temperature of dehydroxylation and dehydration of halloysite is decreased about 100 °C. The infrared emission spectra clearly show the decomposition and dehydroxylation of the halloysite intercalation compound when the temperature is raised. The dehydration of the intercalation compound is followed by the loss of intensity of the stretching vibration bands at region 3600-3200 cm-1. Dehydroxylation is followed by the decrease in intensity in the bands between 3695 and 3620 cm-1. Dehydration was completed by 300 °C and partial dehydroxylation by 350 °C. The inner hydroxyl group remained until around 500 °C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the structure of the title compound, C6H13N2O+ C2H3O2- . H2O, the amide H atoms of the cations form centrosymetric cyclic hydrogen-bonding associations incorporating two water molecules [graph set R^2^~4~(8)], which are conjoint with cyclic water-bridged amide-amide associations [R^4^~4~(12)] and larger R4/4(20) associations involving the water molecule and the acetate anions, which bridge through the piperidinium H donors, giving an overall three-dimensional framework structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an immersion method for preparing the kaolinite-potassium acetate intercalation complexes. The effectiveness of intercalation and influencing factors were analysed and evaluated. The results show that the intercalation of kaolinite by potassium acetate is strongly related to crystallinity of kaolinite, concentration of intercalating agent solution, aging time and pH. The well-crystallized kaolinite is conducive to intercalation by potassium acetate. A higher concentration of intercalating agent (≥30%) can complete the intercalation in a short time (<12h), but at lower concentrations intercalation took significantly longer (≥144h). The weak alkaline condition of pH=10 proved to be the most suitable environment for the formation of intercalation complex. A good intercalated complex can be obtained at room temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thermal behavior and decomposition of kaolinite-potassium acetate intercalation complex was investigated through a combination of thermogravimetric analysis and infrared emission spectroscopy. Three main changes were observed at 48, 280, 323 and 460 °C which were attributed to (a) the loss of adsorbed water (b) loss of the water coordinated to acetate ion in the layer of kaolinite (c) loss of potassium acetate in the complex and (d) water through dehydroxylation. It is proposed that the KAc intercalation complex is stability except heating at above 300 °C. The infrared emission spectra clearly show the decomposition and dehydroxylation of the kaolinite intercalation complex when the temperature is raised. The dehydration of the intercalation complex is followed by the loss of intensity of the stretching vibration bands at region 3600-3200 cm-1. Dehydroxylation is followed by the decrease in intensity in the bands between 3695 and 3620 cm-1. Dehydration is completed by 400 °C and partial dehydroxylation by 650 °C. The inner hydroxyl group remained until around 700 °C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mid-infrared (MIR) and near-infrared (NIR) spectroscopy have been used to study the molecular structure of halloysite and potassium acetate intercalated halloysite and to determine the structural changes of halloysite through intercalation. The MIR spectra show all fundamental vibrations including the hydroxyl units, basic aluminosilicate framework and water molecules in the structure of halloysite and its intercalation complex. Comparison between halloysite and halloysite-potassium acetate intercalation complex shows almost all bands observed for halloysite are also observed for halloysite-potassium acetate intercalation complex apart from bands observed in the 1700-1300 cm-1 region, but with differences in band intensity. However, NIR, based on MIR spectra, provide sufficient evidence to analyze the structural changes of halloysite through intercalation. There are obvious differences between halloysite and halloysite-potassium acetate intercalation complex in the all spectral ranges. Therefore, the reproducibility of measurement and richness of qualitative information should be simultaneously considered for proper selection of a spectroscopic method for molecular structural analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of kaolinite-potassium acetate intercalation composite was prepared. The thermal behavior and decomposition of these composites were investigated by simultaneous differential scanning calorimetry-thermogravimetric analysis (DSC-TGA), X-ray diffraction (XRD) and Fourier-transformation infrared (FT-IR). The XRD pattern at room temperature indicated that intercalation of potassium acetate into kaolinite causes an increase of the basal spacing from 0.718 to 1.428nm. The peak intensity of the expanded phase of the composite decreased with heating above 300°C, and the basal spacing reduced to 1.19nm at 350°C and 0.718nm at 400°C. These were supported by DSC-TGA and FT-IR measurements, where the endothermic reactions are observed between 300 and 600°C. These reactions can be divided into two stages: 1) Removal of the intercalated molecules between 300-400°C. 2) Dehydroxylation of kaolinite between 400-600°C. Significant changes were observed in the infrared bands assigned to outer surface hydroxyl, inner surface hydroxyl, inner hydroxyl and hydrogen bands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a scaling method for templating digital radiographs using conventional acetate templates independent of template magnification without the need for a calibration marker. The mean magnification factor for the radiology department was determined (119.8%, range117%-123.4%). This fixed magnification factor was used to scale the radiographs by the method described. 32 femoral heads on postoperative THR radiographs were then measured and compared to the actual size. The mean absolute accuracy was within 0.5% of actual head size (range 0 to 3%) with a mean absolute difference of 0.16mm (range 0-1mm, SD 0.26mm). Intraclass Correlation Coefficient (ICC) showed excellent reliability for both inter and intraobserver measurements with ICC scores of 0.993 (95% CI 0.988-0.996) for interobserver measurements and intraobserver measurements ranging between 0.990-0.993 (95% CI 0.980-0.997).