974 resultados para Treatment time


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intensity Modulated Radiotherapy (IMRT) is a well established technique for delivering highly conformal radiation dose distributions. The complexity of the delivery techniques and high dose gradients around the target volume make verification of the patient treatment crucial to the success of the treatment. Conventional treatment protocols involve imaging the patient prior to treatment, comparing the patient set-up to the planned set-up and then making any necessary shifts in the patient position to ensure target volume coverage. This paper presents a method for calibrating electronic portal imaging device (EPID) images acquired during IMRT delivery so that they can be used for verifying the patient set-up.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article reports on a series of experiments with polyethylene terepthalate (PET) treated in a radio frequency plasma reactor using argon and oxygen as a gas fuel, for treatment times equal to 5 s, 20 s, 30 s, and 100 s. The mechanical strength modification of PET fibers, evaluated by tensile tests on monofilaments, showed that oxygen and argon plasma treatment resulted in a decrease in the average tensile strength compared with the untreated fibers. This reduction in tensile strength is more significant for argon plasma and is very sensitive to the treatment time for oxygen plasma. Scanning electron microscopy (SEM) used to analyze the effects of cold plasma treatment on fiber surfaces indicates differences in roughness profiles depending on the type of treatments, which were associated with variations in mechanical strength. Differences in the roughness profile, surveyed through an image analysis method, provided the distance of roughness interval, D-ri. This parameter represents the number of peaks contained in a unit length and was introduced to correlate fiber surface condition, before and after cold plasma treatments, and average tensile strength. Statistical analysis of experimental data, using Weibull cumulative distribution and linear representation, was performed to explain influences of treatment time and environmental effects on mechanical properties. The shape parameter, alpha, and density parameter, beta, from the Weibull distribution function were used to indicate the experimental data range and to confirm the mechanical performance obtained experimentally.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUÇÃO: o tratamento ortodôntico de pacientes adultos apresenta grande variabilidade no tempo necessário para sua realização. OBJETIVO: o objetivo desse trabalho foi investigar a influência de diversas variáveis sobre o tempo de tratamento. MÉTODOS: foram examinados 70 casos clínicos, de pacientes adultos, com bom resultado final, coletados em clínicas de três ortodontistas experientes, cujo acervo total inicial era de 4.723 prontuários. A influência das variáveis idade, sexo, padrão facial, severidade inicial da má oclusão (medida por meio do índice PAR), relação sagital de caninos, tipo de braquetes (estético ou metálico), exodontias, faltas às consultas e "quebras" de aparelho, sobre o tempo de tratamento (variável dependente), foram avaliadas por meio da análise de regressão linear múltipla, seguida do método Stepwise, com p < 0,05. RESULTADOS: a quantidade de faltas (R2 = 14,04%, p < 0,0001) e o número de "quebras" do aparelho (R2 = 29,71%, p = 0,0037) tiveram influência significativa na variação do tempo de tratamento, sendo essas duas variáveis juntas capazes de prever 43,75% (R2 total) da variação no tempo de tratamento. Outros fatores, como a relação de caninos ao início do tratamento, o tipo de braquete usado (metálico ou cerâmico), exodontias, a idade ao início do tratamento, a severidade inicial da má oclusão, o sexo do paciente e o padrão facial não tiveram influência significativa sobre o tempo de tratamento. CONCLUSÃO: a duração do tratamento ortodôntico em adultos, quando realizado por ortodontistas experientes, sofre influência, principalmente, de fatores associados à colaboração do próprio paciente. Entretanto, diversos fatores não incluídos nesse estudo podem contribuir para a variação na duração do tratamento ortodôntico.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To analyze the cost and time requirement per achieved pregnancy in optimized modified natural cycle in vitro fertilization (mNC-IVF) based on a treatment protocol with very few consultations and to compare those with conventional gonadotropin-stimulated aVF (clVF) cycles. STUDY DESIGN Mono centric prospective trial. Eighty infertile patients each received 1 modified mNC-IVF cycle using low doses of the clomiphene citrate. Based on the number of consultations and the clinical pregnancy rate per cycle, the total costs and required time to achieve a pregnancy were analyzed and compared with cIVF. Calculations for cIVF were based on standard therapy protocols and outcomes of European registries. RESULTS Patients (21-42 years old, 35.4 +/- 4.7 years) undergoing mNC-IVF required on average 1.2 consultations before follicle aspiration. Pregnancy rate per transfer and per initiated cycle were 25% and 13.6%, respectively. Multiple pregnancies did not occur. According to the calculations, total costs per pregnancy rate were around 15% lower with mNC-IVF as compared to cIVF. In contrast, time to achieve an equal pregnancy rate was calculated to take around 30% longer with mNC-IVF as compared to cIVF. CONCLUSION mNC-IVF using very low dosages of clomiphene citrate avoids multiple pregnancies and is less expensive but more time consuming per achieved pregnancy when compared to clVF.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mg alloys are attractive materials for medical devices. The main limitation is that they are prone to corrosion. A low toxicity surface coating that enables uniform, controlled corrosion at a desired rate (this usually means it must offer barrier functions for a limited time period) is desirable. Phosphate-based ionic liquids (ILs) are known to induce a coating that can reduce the corrosion rate of Mg alloys, Furthermore, some ILs are known to be biocompatible and therefore, controlling the corrosion behaviour of an Mg alloy and its surface biocompatibility can be achieved through adding an appropriate low toxic IL surface layer to the substrate. In this study, we have evaluated the cytotoxicity of three phosphate-based ILs to primary human coronary artery endothelial cells. Among them, tributyl(methyl)-phosphonium diphenylphosphate (P1,4,4,4dpp) shows the lowest cytotoxicity. Therefore, further work was aimed at developing an appropriate treatment method to produce a homogeneous and passive surface coating based on P1,4,4,4dpp IL, with the focus on investigating the effect of treatment time. The results showed that that the formation of IL coating on AZ31 has proceeded progressively, and treatment time plays an important role. An IL treatment at 100 °C with an extended treatment time of 5 h significantly enhanced corrosion resistance of the AZ31 alloy in simulated body fluid. Additionally, the corrosion morphology was uniform and there was no evidence of "localized pitting corrosion" observed. Such a performance makes this ionic liquid coating as a potential surface coating biodegradable Mg-based implants.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

White nectarines (Prunus persica var. nucipersica) were fumigated with methyl bromide (MB) at a nominal treatment dose of 18 g m-3 at 18°C for 5 h and 30 min as a quarantine disinfestation treatment against Bactrocera tryoni, the Queensland fruit fly. Three large scale trials were conducted against each of the four immature lifestages, eggs and first, second and third instars. There were no survivors from the estimated 43,614 eggs, 41,873 first instars, 41,345 second instars and 33,549 third instars treated, thereby resulting in an efficacy of GROTERDAN99.99% mortality at the 95% confidence level for each lifestage. Of the 12 trials reported herein, the highest concentration of MB, sampled from the chamber headspace analysed by gas chromatography, was 18.7 g m-3. The maximum chamber temperature from 5 min readings was 19.7°C and the maximum fruit core temperature was 19.5°C. The treatment time for all trials was exactly 5.5 h. Thus the recommended treatment dose to disinfest nectarines from B. tryoni is 19.0 g m-3 MB at 20.0°C for 5.5 h. Fruit quality trials were conducted on white nectarines at three combinations of treatment parameters: 15 g m-3 MB at 19°C for 5.25 h; 18 g m-3 MB at 19°C for 5.5 h and 21 g m-3 MB at 19°C for 5.5 h. The fruit were stored at 0, 4 and 8 days at 4°C and 8 days at 4°C followed by 4 d at 22°C. They were then were assessed for skin colour, flesh colour, skin defects, flesh defects, fruit weight loss, flesh firmness, total soluble solids, titratable acidity and rots. There was no significant difference between untreated control and MB treated fruits in any of the parameters measured. Thus the treatments did not have adverse effects on fruit quality.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this study, a detailed investigation on the effect of heat treatment on the microstructural characteristics, texture evolution and mechanical properties of Mg-(5.6Ti+2.5B(4)C)(BM) hybrid nanocomposite is presented. Optimised heat treatment parameters, namely, heat treatment temperature and heat treatment time, were first identified through grain size and microhardness measurements. Initially, heat treatment of composites was conducted at temperature range between 100 and 300 degrees C for 1 h. Based on optical microscopic analysis and microhardness measurements, it was evident that significant grain growth and reduction in microhardness occurred for temperatures > 200 degrees C. The cutoff temperature that caused significant grain growth/matrix softening was thus identified. Second, at constant temperature (200 degrees C), the effect of variation of heat treatment time was carried out (ranging between 1 and 5 h) so as to identify the range wherein increase in average grain size and reduction in microhardness occurred. Furthering the study, the effect of optimised heat treatment parameters (200 degrees C, 5 h) on the microstructural texture evolution and hence, on the tensile and compressive properties of the Mg-(5.6Ti+2.5B(4)C)(BM) hybrid nanocomposite was carried out. From electron backscattered diffraction (EBSD) analysis, it was identified that the optimised heat treatment resulted in recrystallisation and residual stress relaxation, as evident from the presence of similar to 87% strain free grains, when compared to that observed in the non-heat treated/as extruded condition (i.e. 2.2 times greater than in the as extruded condition). For the heat treated composite, under both tensile and compressive loads, a significant improvement in fracture strain values (similar to 60% increase) was observed when compared to that of the non-heat treated counterpart, with similar to 20% reduction in yield strength. Based on structure-property correlation, the change in mechanical characteristics is identified to be due to: (1) the presence of less stressed matrix/reinforcement interface due to the relief of residual stresses and (2) texture weakening due to matrix recrystallisation effects, both arising due to heat treatment.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

To form low-resistance Ohmic contact to p-type GaN, InGaN/GaN multiple quantum well light emitting diode wafers are treated with boiled aqua regia prior to Ni/Au (5 nm/5 nm) film deposition. The surface morphology of wafers and the current-voltage characteristics of fabricated light emitting diode devices are investigated. It is shown that surface treatment with boiled aqua regia could effectively remove oxide from the surface of the p-GaN layer, and reveal defect-pits whose density is almost the same as the screw dislocation density estimated by x-ray rocking curve measurement. It suggests that the metal atoms of the Ni/Au transparent electrode of light emitting diode devices may diffuse into the p-GaN layer along threading dislocation lines and form additional leakage current channels. Therefore, the surface treatment time with boiled aqua regia should not be too long so as to avoid the increase of threading dislocation-induced leakage current and the degradation of electrical properties of light emitting diodes

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objectives: to assess elderly patients’ dental status and dental habits and compare the survival rates, impact on patients’ quality of life and cost-effectiveness of Atraumatic Restorative Treatment (ART) and a conventional treatment (CT) to restore carious lesions in an elderly population. Methods: In this randomised clinical trial, 99 independently living adults (65-90 yrs) with carious lesions were randomly allocated to receive either ART or CT. Details of restored, missing and carious teeth were recorded and patients answered some questions about their oral hygiene and dental attendance habits. Direct and indirect costs were measured based on treatment time, materials and labour. Effectiveness was measured using restoration survival percentage after one year. The survival of restorations was assessed 6 months and one year after restoration placement by an independent examiner. Oralhealth related quality of life (OHRQoL) was assessed using the OHIP-14 at baseline and 2 months after treatment together with a global transition statement. Results: The patient sample comprised 46 (46.46%) male and 53 (53.54) female participants at baseline, with a mean age of 73.18 (SD=6.76). The mean DMFT of the entire sample was 27.10. Ninety patients and 268 restorations could be assessed after one year, 127 ART (46 patients) and 141 conventional restorations (44 patients). 93.7% and 97.2% of the restorations placed were considered successful in the ART and CT groups, respectively. The OHIP scores did not change dramatically 2 months after treatment, in either group. The global transition scale showed an improvement in overall oral health after treatment for the majority of patients. The ART were more cost-effective compared to the CT restorations. Conclusions: ART presented survival rates similar to CT after 1 year and was a more cost-effective alternative to treat the elderly.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective. To compare clinical response to initial empiric treatment with oxacillin plus ceftriaxone and amoxicillin plus clavulanic acid in hospitalized children diagnosed with very severe community-acquired pneumonia (CAP).Methods. A prospective randomized clinical study was conducted among children 2 months to 5 years old with a diagnosis of very severe CAP in the pediatric ward of São Paulo State University Hospital in Botucatu, São Paulo, Brazil, from April 2007 to May 2008. Patients were randomly divided into two groups by type of treatment: an oxacillin/ceftriaxone group (OCG, n = 48) and an amoxicillin/clavulanic acid group (ACG, n = 56). Analyzed outcomes were: time to clinical improvement (fever and tachypnea), time on oxygen therapy, length of stay in hospital, need to widen antimicrobial spectrum, and complications (including pleural effusion).Results. The two groups did not differ statistically for age, sex, symptom duration before admission, or previous antibiotic treatment. Time to improve tachypnea was less among ACG patients than OCG patients (4.8 +/- 2.2 versus 5.8 +/- 2.4 days respectively; P = 0.028), as was length of hospital stay (11.0 +/- 6.2 versus 14.4 +/- 4.5 days respectively; P = 0.002). There were no statistically significant differences between the two groups for fever improvement time, time on oxygen therapy, need to widen antimicrobial spectrum, or frequency of pleural effusion.Conclusions. Both treatment plans are effective in treating very severe CAP in 2-monthto 5-year-old hospitalized children. The only analyzed outcome that favored amoxicillin/clavulanic acid treatment was time required to improve tachypnea.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this work, BSTSn powders prepared by the polymeric precursor method were heat treated in a domestic microwave oven (MW) using a SiC susceptor to absorb the microwave energy and transfer the heat to the powder. The main advantage of MW is to reduce the thermal treatment time for phase crystallization. The powders were heat treated at 300 degrees C for 20 h in conventional oven, 300 degrees C for 10 min, 20 min, and 30 min in MW and at 500 degrees C for 1 min in MW. After thermal treatment, the photoluminescent properties of powders at room temperature were analyzed. (c) 2007 Published by Elsevier B.V.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Nitrogen implantation into Ti alloys at higher temperatures improves their mechanical and corrosion resistance properties by forming a thicker nitride layer. In this paper, two different sets of Ti-6Al-4V samples were plasma immersion ion implantation (PIII)-treated using nitrogen plasma, varying the treatment time from 30 to 150 min (800 degrees C) and the process temperature from 400 degrees C to 800 degrees C (t = 60 min). Nanoindentation measurements of the PIII-treated samples at 800 C during 150 min showed the highest hardness value, 24 GPa, which is about four times bigger than untreated sample hardness. The N penetration at these conditions reached approximately 150 nm as analyzed by Auger spectroscopy. on the other hand, the lowest passive current density (3 x 10(-7) A. cm(-2)) was obtained for a PIII-treated sample during 30 min at higher temperature (800 degrees C). The corrosion resistance of this sample is almost the same as for the untreated specimen. Corrosion behavior evidenced that in strong oxidizing media, all PIII-treated samples are more corrosion resistant than the untreated one. PIII processing at higher temperatures promotes smoothing of the sample surface as observed by scanning electron microscopy (SEM). Grazing incidence X-ray diffraction analyses of the untreated samples identified the two typical Ti phases, Ti alpha and Ti beta. After the implantation, Ti2N and TiO2 phases were also detected.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: This article reports preliminary clinical results of the Speed Master system, a method for immediate loading of implants for the treatment of mandibular edentulism. Materials and Methods: Fifteen patients with edentulous mandibles were consecutively included in the study. Each received 4 implants between the mental foramina placed using the system's surgical guides. Permanent fixed prostheses fabricated over premanufactured titanium bars were attached to the implants on the day of implant placement. The patients were followed for 15 to 27 months (mean, 19 months). Peri-implant tissues were periodically evaluated. Marginal bone loss was monitored with periapical radiographs using a computerized technique. Satisfaction was assessed by means of a questionnaire. Results: The overall implant and prosthetic survival rates were 100%. At the time of the final follow-up visit, mean marginal bone loss was 1.11 mm, and bleeding on probing was not observed. Only 6.7% of the patients reported any discomfort during treatment, and all patients would recommend the procedure to others. Discussion: The immediate loading of implants placed in the edentulous mandible with the Speed Master surgical and prosthetic protocol reduces treatment time and number of surgical procedures in comparison to classic delayed loading protocols. Conclusion: The rehabilitation of the mandible with an immediately delivered occlusally loaded hybrid prosthesis supported by 4 implants does not appear to jeopardize the success of the osseointegration and represents a viable treatment option.