935 resultados para Total hip replacement
Resumo:
Objective: Our aim was to evaluate the challenges in obtaining a successful restoration of the rotation center as well as a good positioning of the acetabular component when using the minimally-invasive posterior approach for uncemented total hip replacement. Methods: In a comparative non-random prospective study, 64 adult patients underwent elective total hip arthroplasty using the minimally-invasive posterior approach performed by one single surgeon, All patients included in this study had a superior and lateral migration of the rotation center of the hip in comparison to the normal contralateral hip. Patients were excluded from the study if they presented the following: diagnosis of femoral neck fracture, displasic hip types 2, 3 and 4 (Crowe`s classification), osteoarthritis of the contralateral hip. Of the 64 patients in the study, 39 had a radiographic pre-op acetabular size planning equal or less than 50 mm and 25 patients had a radiographic pre-op acetabular size planning equal or more than 52 mm. We considered a good result the following goals: acetabular bend between 35 and 50 degrees, acetabular size according to the pre-op estimative with full contact in the three zones of DeLee-Charnley, a lower medial and vertical positioning of the rotation center in comparison with the pre-op values and a final limb discrepancy lower than 10 mm. Results: A better restoration of the rotation center, as well as, excellent acetabular positioning was found in patients with smaller acetabular size (equal or less than 50), p=0, 04. We must draw attention to two risks when using the minimally-invasive posterior approach: a vertical acetabular position and a lateral position of the acetabular component increasing the risk of a poor contact in the zone 1 due to an insufficient reaming of the medial acetabular host bone. Conclusion: We propose standard surgical approaches in patients with larger anatomical measurements (acetabular planning size more than 50).
Resumo:
INTRODUCTION: The risk that hip preserving surgery may negatively influence the performance and outcome of subsequent total hip replacement (THR) remains a concern. The aim of this study was to identify any negative impact of previous hip arthroscopy on THR. METHODS: Out of 1271 consecutive patients who underwent primary THR between 2005 and 2009, 18 had previously undergone ipsilateral hip arthroscopy. This study group (STG) was compared with two control groups (CG, same approach, identical implants; MCG, paired group matched for age, BMI and Charnley categories). Operative time, blood loss, evidence of heterotopic bone and implant loosening at follow-up were compared between the STG and the MCG. Follow-up WOMAC were compared between the three groups. RESULTS: Blood loss was not found to be significantly different between the STG and MCG. The operative time was significantly less (p < 0.001) in the STG. There was no significant difference in follow-up WOMAC between the groups. No implant related complications were noted in follow-up radiographs. Two minor complications were documented for the STG and three for the MCG. CONCLUSION: We have found no evidence that previous hip arthroscopy negatively influences the performance or short-term clinical outcome of THR.
Resumo:
Painful total hip replacement remains a challenging problem because of the large amount of possible diagnoses. We report about a 64-year-old female patient who was misdiagnosed during 4 years as psychiatric. She suffered of excruciating left retrotrochanteric pain after the implantation of a cementless total hip replacement and revision because of recurrent hip dislocations. Walking was limited to short distances using two crutches. The work-up at this time included the usual diagnoses and remained unsuccessful. No loosening, infection or malposition of the prosthesis could be found, and she had no neurologic deficits in her operated leg. An MRI was obtained to visualize the retrotrochanteric soft tissues and showed a tight scar surrounding the sciatic nerve, which was also compressed by an adjacent lipoma. Therefore, she was reoperated on to remove the lipoma and the scar tissue around the sciatic nerve. To decrease the risk of recurrent scarring around the sciatic nerve, an adhesion barrier was applied before closure. One year after the operation, the patient has no neurologic deficit, no more pain and is able to walk unlimited distances without crutches. Scar tissue around the sciatic nerve is frequently observed during revision surgery. However, we feel that sciatic nerve entrapment by scar tissue should be a part of the differential diagnosis of painful THR. MRI may be a useful tool to achieve this diagnosis.
Resumo:
PURPOSE: The aim of this study was to determine outcomes of total hip replacement (THR) with the Lemania cemented femoral stem. METHODS: A total of 78 THR patients were followed and compared to 17 "fit", healthy, elderly and 72 "frail" elderly subjects without THR, using clinical outcome measures and a portable, in-field gait analysis device at five and ten years follow-up. RESULTS: Forty-one patients (53%), mean age 83.4 years, available at ten years follow-up, reported very good to excellent satisfaction. Mean Harris Hip and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores were 81.2 and 10.5 points, respectively, with excellent radiological preservation of proximal femur bone stock. Spatial and temporal gait parameters were close to the fit group and better than the frail group. CONCLUSIONS: Lemania THR demonstrated very good, stable clinical and radiological results at ten years in an older patient group, comparable to other cemented systems for primary THR. Gait analysis confirmed good walking performance in a real-life environment.
Resumo:
BACKGROUND: The literature suggests that intraoperative fractures of the greater trochanter and the metaphysis are increased with uncemented stems and the direct anterior approach. This study aims to determine the incidence and assess the functional and radiological outcome after such fractures. METHODS: 484 consecutive total hip replacements (THR) (64 ± 12 years) were analyzed. We treated trochanteric fractures conservatively without any further denuding, and secured metaphyseal fissures with cerclages. Postoperative X-rays and at the latest follow-up were compared to assess secondary fracture displacement and stem subsidence. Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores after 1 year were analyzed. For each patient sustaining a fracture, two patients without fractures were matched in terms of age, body mass index and gender. RESULTS: 13 (2.7 %, 5 male, 68 ± 9 years) patients with intraoperative fractures of the greater trochanter (n = 8) or the metaphysis (n = 5) were analyzed. Consolidation was observed in 7/8 patients sustaining a trochanteric fracture while secondary displacement of the fragment occurred in one case. Stem subsidence was observed in 2/5 cases (5 and 7 mm). Patients who sustained a fracture showed a trend towards poorer WOMAC scores at 1 year postoperatively, compared to patients without fractures. A significantly increased joint stiffness was also observed. CONCLUSION: The intraoperative fracture risk in this series of THR through a direct anterior approach was 2.7 %. Trochanteric fractures do heal without primary fixation. Metaphyseal fractures heal well if immediately stabilized with a cerclage.
Resumo:
Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.
Resumo:
La sostituzione totale d’anca è uno degli interventi chirurgici con le più alte percentuali di successo. Esistono due varianti di protesi d’anca che differiscono in base al metodo di ancoraggio all’osso: cementate (fissaggio tramite cemento osseo) e non cementate (fissaggio tramite forzamento). Ad oggi, i chirurghi non hanno indicazioni quantitative di supporto per la scelta fra le due tipologie di impianto, decidendo solo in base alla loro esperienza. Due delle problematiche che interessano le protesi non cementate sono la possibilità di frattura intra-operatoria durante l’inserimento forzato e il riassorbimento osseo nel periodo di tempo successivo all’intervento. A partire da rilevazioni densitometriche effettuate su immagini da TC di pazienti sottoposti a protesi d’anca non cementata, sono stati sviluppati due metodi: 1) per la valutazione del rischio di frattura intra-operatorio tramite analisi agli elementi finiti; 2) per la valutazione della variazione di densità minerale ossea (tridimensionalmente attorno alla protesi) dopo un anno dall’operazione. Un campione di 5 pazienti è stato selezionato per testare le procedure. Ciascuno dei pazienti è stato scansionato tramite TC in tre momenti differenti: una acquisita prima dell’operazione (pre-op), le altre due acquisite 24 ore (post 24h) e 1 anno dopo l’operazione (post 1y). I risultati ottenuti hanno confermato la fattibilità di entrambi i metodi, riuscendo inoltre a distinguere e a quantificare delle differenze fra i vari pazienti. La fattibilità di entrambe le metodologie suggerisce la loro possibilità di impiego in ambito clinico: 1) conoscere la stima del rischio di frattura intra-operatorio può servire come strumento di guida per il chirurgo nella scelta dell’impianto protesico ottimale; 2) conoscere la variazione di densità minerale ossea dopo un anno dall’operazione può essere utilizzato come strumento di monitoraggio post-operatorio del paziente.
Resumo:
The puqjose of this study was to examine the manner in which an inviting approach to a preoperative teaching and learning educational experience influenced the perception and subsequent recovery of clients who were awaiting total hip and total knee replacement surgery. An in-depth review of the internal and external factors that shape client perceptions was undertaken in this study. In addition, this study also explored whether or not the Prehab Program was preparing clients physically, socially, and psychologically for surgery. Data for this qualitative case study research were collected through preoperative interviews with 4 participants awaiting total hip replacement surgery and 1 participant awaiting total knee replacement surgery. Four postoperative interviews were conducted with the participants who had received total hip replacement surgery. The occupational therapist and physical therapist who were the coleaders of the Prehab Program at the time of this study were also interviewed. The results of this study suggest that while individuals may receive similar educational experiences, their perceptions of the manner in which they benefited from these experiences varied. This is illustrated in the research findings, which concluded that while clients benefited physically from the inviting approach used during the practical teaching session, not all clients perceived the psychological benefits of this practice session, especially clients with preexisting high levels of anxiety. In addition to increasing the understanding of the internal as well as external factors that influence the perceptions of clients, this study has also served as an opportunity for reflection on practice for the Prehab therapists and other healthcare educators.
Resumo:
The aim of this investigation was to assess the diagnostic accuracy of intraoperative cultures for the early identification of patients who are at risk of infection after primary total hip arthroplasty. Four or six swabs were obtained immediately before the wound closure in 263 primary total hip replacements. Patients with a maximum of one positive culture were denoted as patients with a normal profile and did not receive any treatment. Patients with two or more positive cultures, with the same organism identified, were denoted as patients with a risk profile and received treatment with a specific antibiotic as determined by the antibiogram for six weeks. The follow-up ranged from a minimum of one year to five years and eleven months, concentrating on the presence or absence of infection, which was defined as discharge of pus through the surgical wound or as a fistula at any time after surgery. The accuracy of this procedure ( number of cases correctly identified in relation to the total number of cases) in the group of 152 arthroplasties in which 4 swabs per patient were collected was 96%. In the group of 111 arthroplasties in which 6 swabs per patient were collected the accuracy was 95.5%. We conclude that the collection of swabs under the conditions described is a method of high accuracy ( above 95%) for the evaluation of risk of infection after primary total hip arthroplasty.
Resumo:
We describe the use of cable fixation and acute total hip replacement for acetabular fracture in the elderly. 12 patients with acetabular fractures, having a mean age of 79 (65-93) years, were treated with cable fixation and acute total hip arthroplasty. 8 were T-shaped fractures and 4 associated fractures of the posterior column and posterior wall. 1 patient died 5 months after surgery and the remaining 11 were followed for 2 years. All patients had a good clinical outcome. Radiographic assessment showed healing of the fracture and a satisfactory alignment of the cup without loosening. This surgical technique provides good primary fixation, stabilizes complex acetabular fractures in elderly patients with osteoporotic bone and permits early postoperative mobilization.