915 resultados para Total hip arthroplasty revision surgery · tabular reconstruction · Bone loss · Ceramics


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Management of bone loss in revision total hip replacement remains a challenge. To eliminate any immunological or infectious problem and so to try to improve the long-term results obtained with allografts, the authors used synthetic ceramics as bone substitutes since 1995. We reviewed 13 of the patients of our study, we previously reported in 2005 (Schwartz and Bordei in Eur J Orthop Surg Traumatol 15: 191 2005), which was a pro- spective cohort of thirty-two cases of acetabular revision reconstruction, with a mean follow-up of 14.4 years yet (from 9 to 16 years). Clinical results were assessed according to Oxford scale and Postel and Merle d'Aubigne (PMA) scale. Since 2005, no specific complications were noted. The average PMA functional hip score was 14.9 (vs. 9.2 before revision) at follow-up over 9 years. Nine patients still alive in 2013 were seen again by a surgeon, which was not the operator, with a mean follow-up of 15.3 years: Their Oxford average score was 40.3. Radio- logical assessment affirmed a good integration of the sub- stitutes in bone without any edging in all cases. A progressive invasion of the ceramics by bone can be seen on the X-ray. We conclude that about 15 years of average delay, which is a significant follow-up in orthopedic sur- gery, the outcomes without specific complications are satisfactory and allow one to go with these materials in total hip revision surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are many different opinions in the literature regarding the best procedure for revision of infected hip arthroplasty and hence in achieving long-term stabilization of a new implant. Thirty-two patients with 32 loose and infected total hip arthroplasties underwent revision with a bone graft in a 1-stage procedure. The bone graft was used in the acetabulum and femure in 25 patients, in the acetabulum alone in 4 patients and in the femur alone in 3 patients. A metal mesh was necessary in 15 patients to contain the morselized bone graft. At the time of surgical revision, 9 patients had a draining sinus, 6 had a closed sinus, and 17 had never had sinuses in the surgical wound. Antibiotic therapy was administered intravenously and orally for 6 months. Mean follow-up was 103 months (range, 63-183 months), and infection recurred in 2 (6.2%) cases. Further studies are necessary, and continuation of this method is justified.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pelvic discontinuity is a complex problem in revision total hip arthroplasty. Although rare, the incidence is likely to increase due to the ageing population and the increasing number of total hip arthroplasties being performed. The various surgical options available to solve this problem include plating, massive allografts, reconstruction rings, custom triflanged components and tantalum implants. However, the optimal solution remains controversial. None of the known methods completely solves the major obstacles associated with this problem, such as restoration of massive bone loss, implant failure in the short- and long-term and high complication rates. This review discusses the diagnosis, decision making, and treatment options of pelvic discontinuity in revision total hip arthroplasty.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reconstruction of important parameters such as femoral offset and torsion is inaccurate, when templating is based on plain x-rays. We evaluate intraoperative reproducibility of pre-operative CT-based 3D-templating in a consecutive series of 50 patients undergoing primary cementless THA through an anterior approach. Pre-operative planning was compared to a postoperative CT scan by image fusion. The implant size was correctly predicted in 100% of the stems, 94% of the cups and 88% of the heads (length). The difference between the planned and the postoperative leg length was 0.3 + 2.3 mm. Values for overall offset, femoral anteversion, cup inclination and anteversion were 1.4 mm ± 3.1, 0.6° ± 3.3°, -0.4° ± 5° and 6.9° ± 11.4°, respectively. This planning allows accurate implant size prediction. Stem position and cup inclination are accurately reproducible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hip resurfacing arthroplasty (HRA) and large head metal-on-metal total arthroplasty (LDH MoM THA) gained popularity during the last decade. Adverse reaction to metal debris (ARMD) is a unique complication of metal bearings. ARMD is a complex reaction caused by metal debris from metal-on- metal bearing surfaces and from trunnion corrosion of modular junctions. We analyzed survivorship of 8059 LDH MoM THAs based on data of the Finnish Arthroplasty Register. We found relatively high short-term survivorship for some LDH MoM THAs, but there were remarkable differences between the devices studied. After some alarming reports of failing MoM THAs, we studied the first 80 patients who had received a ReCap-M2a-Magnum implant at our institution and evaluated the prevalence of ARMD. We found a high prevalence of pseudotumors, and, because of this, we discontinued the use of MoM bearings and followed up all patients with a MoM THA. Bone loss due infection, osteolysis or fracture poses a great challenge for reconstructive and fracture surgery. Onlay allografting for both revision and fracture surgery provides mechanical stability and increases bone stock. Bone loss and implant stability must be assessed preoperatively and adequately classified; this provides guidelines for the operative treatment of periprosthetic fractures and revision THA. In our studies on structural allografts union rates were high, although the rates of infections and dislocations were marked. In summary, early results of the use of LDH MoM devices were encouraging. However, the survival of the LDH MoMs varied. The prevalence of adverse reaction to metal debris was high after application of the ReCap-Magnum THA. New implants should be introduced carefully and under close surveillance by University clinics and arthroplasty registers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Total hip arthroplasty (THA) still carries a higher failure rate in patients with avascular necrosis of the femoral head (AVN) than in a similar patient population with THA for other reasons. This is particularly true for the acetabular component. One of the major factors accounting for this is the compromised acetabular bone quality with structural defects subsequent to collapsing of the femoral head in high-grade AVN. In this study we implanted an acetabular reinforcement ring with hook (ARRH), which had been used successfully for other indications with acetabular bone stock deficiency, in 32 consecutive THA's in 29 patients with AVN. Five patients died during the observation period of causes unrelated to the surgery, one patient was lost to follow-up and one patient could not be followed up due to chronic illness, leaving 25 hips (23 patients) with a minimum follow-up of ten years (mean: 11.8; range: 10-15). The mean Merle d'Aubigne score increased significantly from 7.7 preoperatively to 16.6 postoperatively (p < 0.001). One revision was performed for aseptic stem loosening. Of the unrevised hips, one acetabular component was classified as definitively loose. The cumulative 12-year survivorship for THA with ARRH in AVN was 95.2% (confidence interval: 86.1-100%) for both components, 100% for the cup and 95.2% for the stem (86.1-100%).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The published data on pain and physical function before and after revision of total hip arthroplasty (THA) is scarce. The study reports the course and interrelationships of radiographic loosening, pain and physical function 5 year before and after a first revision THA. Methods: The study was based on the IDES-THA database. All patients with their first THA revision for aseptic loosening and a documented index surgery on the same side and at least one pre-revision and one post-revision follow-up were selected. Only patients with an intact contralateral hip joint (Charnley class-A) were included. Follow-ups within ±5.5 years around the revision time point were analyzed. Annual prevalences of radiographic component loosening and the non-desired outcomes (moderate/severe/intolerable pain, walking <30 minutes, hip flexion range <90°) were calculated. Results: Signs of radiographic component loosening started to increase about 4 years before revision surgery. Two years later, a sharp increase of painful hips from 15% to 80% in the revision year was observed. In the year after revision surgery, this rate dropped back to below 10%. Walking capacity started to noticeably deteriorate 3 years before revision and in the revision year about 65% of patients could not walk longer than 30 minutes. As opposed to pain, walking capacity did not recover to pre-revision levels and the best outcome was only reached two years post-revision. Hip flexion range had the slowest and least extent of deterioration (≈45% flexed <70° in the revision year) but with the best outcomes at only three years after revision surgery it took the longest to recover. Conclusion: Prevalence of radiological loosening signs and/or pain intensity follow an almost parallel course around the first revision of a THA for aseptic component loosening. This process begins about 4 years (radiographic loosening) before the actual revision surgery and intensifies about 2 years later (pain). It also involves walking capacity and hip range of motion. While pain levels go back to levels similar to those after primary surgery, range of motion and even more walking capacity remain moderately compromised.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is the first report of surface-active phospholipid as the boundary lubricant in total hip arthroplasty. Aspirate and rinsings from the bearing surfaces of 25 revision operations and one primary surgery were analyzed from 3 weeks to 26 years postoperatively. All samples contained substantial amounts of surface-active phospholipids ranging from 14 to 4186 μg. These findings indicate that synoviocytes continue producing the lubricant in significant quantities after arthroplasty surgery independent of the type of joint replacement and its fixation. Surface-active phospholipid was found on all bearing surfaces analyzed including polyethylene, stainless steel, chrome cobalt, alumina, zirconia, and titanium.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe the use of cable fixation and acute total hip replacement for acetabular fracture in the elderly. 12 patients with acetabular fractures, having a mean age of 79 (65-93) years, were treated with cable fixation and acute total hip arthroplasty. 8 were T-shaped fractures and 4 associated fractures of the posterior column and posterior wall. 1 patient died 5 months after surgery and the remaining 11 were followed for 2 years. All patients had a good clinical outcome. Radiographic assessment showed healing of the fracture and a satisfactory alignment of the cup without loosening. This surgical technique provides good primary fixation, stabilizes complex acetabular fractures in elderly patients with osteoporotic bone and permits early postoperative mobilization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Medialization of the cup with a respective increase in femoral offset has been proposed in THA to increase abductor moment arms. Insofar as there are potential disadvantages to cup medialization, it is important to ascertain whether the purported biomechanical benefits of cup medialization are large enough to warrant the downsides; to date, studies regarding this question have disagreed. QUESTIONS/PURPOSES: The purpose of this study was to quantify the effect of cup medialization with a compensatory increase in femoral offset compared with anatomic reconstruction for patients undergoing THA. We tested the hypothesis that there is a (linear) correlation between preoperative anatomic parameters and muscle moment arm increase caused by cup medialization. METHODS: Fifteen patients undergoing THA were selected, covering a typical range of preoperative femoral offsets. For each patient, a finite element model was built based on a preoperative CT scan. The model included the pelvis, femur, gluteus minimus, medius, and maximus. Two reconstructions were compared: (1) anatomic position of the acetabular center of rotation, and (2) cup medialization compensated by an increase in the femoral offset. Passive abduction-adduction and flexion-extension were simulated in the range of normal gait. Muscle moment arms were evaluated and correlated to preoperative femoral offset, acetabular offset, height of the greater trochanter (relative to femoral center of rotation), and femoral antetorsion angle. RESULTS: The increase of muscle moment arms caused by cup medialization varied among patients. Muscle moment arms increase by 10% to 85% of the amount of cup medialization for abduction-adduction and from -35% (decrease) to 50% for flexion-extension. The change in moment arm was inversely correlated (R(2) = 0.588, p = 0.001) to femoral antetorsion (anteversion), such that patients with less femoral antetorsion gained more in terms of hip muscle moments. No linear correlation was observed between changes in moment arm and other preoperative parameters in this series. CONCLUSIONS: The benefit of cup medialization is variable and depends on the individual anatomy. CLINICAL RELEVANCE: Cup medialization with compensatory increase of the femoral offset may be particularly effective in patients with less femoral antetorsion. However, cup medialization must be balanced against its tradeoffs, including the additional loss of medial acetabular bone stock, and eventual proprioceptive implications of the nonanatomic center of rotation and perhaps joint reaction forces. Clinical studies should better determine the relevance of small changes of moment arms on function and joint reaction forces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Potilaiden käsitys terveyteen liittyvästä elämänlaadusta lonkan tekonivelleikkauksen jälkeisenä toipumisaikana – kuuden kuukauden seurantatutkimus Tässä kaksivaiheisessa seurantatutkimuksessa tarkasteltiin potilaiden käsitystä terveyteen liittyvästä elämänlaadusta lonkan tekonivelleikkauksen jälkeisenä toipumisaikana. Tutkimuksen ensimmäisessä vaiheessa tarkoituksena oli sekä kuvailla potilaiden kokemuksia potilaana olosta, saamastaan hoidosta ja terveyspalveluorganisaatiosta että analysoida aikaisempien tutkimusten perusteella leikkauksen tuloksia potilaan kannalta. Toisessa vaiheessa tarkoituksena oli arvioida potilaiden kokemaa elämänlaatua leikkauksen jälkeen, ja sitä vaikuttivatko primaaritulokset (fyysinen toimintakyky, kipu, ahdistus) tai taloudelliset seuraukset (potilaiden itsensämaksamat kustannukset, palvelujen käyttö) terveyteen liittyvään elämänlaatuun. Tutkimuksen tavoitteena oli löytää mahdolliset kriittiset ajankohdat tai tekijät, jotka saattavat hidastaa toipumista ja siten huonontaa potilaiden elämänlaatua. Tätä tietoa voidaan käyttää hoitotyössä kun suunnitellaan sopivaa hoitoa ja tukea toipumisajalle. Tutkimuksen ensimmäisessä vaiheessa primaarileikkaukseen tulevat potilaat (n = 17) kuvailivat teemahaastatteluissa kokemuksiaan kahdesti leikkauksen jälkeen. Haastatteluaineisto analysoitiin induktiivisella sisällönanalyysilla. Lisäksi 17 tutkimusartikkelista analysoitiin deduktiivisella sisällönanalyysilla leikkauksen tuloksia potilaalle, tuloksiin vaikuttavia tekijöitä ja käytetyt tutkimusmetodit. Toisessa vaiheessa primaari- tai revisioleikkaukseen tulevat potilaat (n = 100) arvioivat leikkauksen tuloksia kuuden kuukauden ajan leikkauksen jälkeen: terveyteen liittyvää elämänlaatua, primaarituloksia ja taloudellisia seurauksia. Aineisto kerättiin erilaisilla mittareilla: Sickness Impact Profile, Finnish Version, Stait-Trait Anxiety Inventory, ja Numeric Rating Scale. Lisäksi käytettiin tätä tutkimusta varten tehtyjä kyselylomakkeita: Fyysinen toimintakyky-mittari, Palvelujen käyttö-mittari ja Kustannusmittari. Tutkimuksen toiseen vaiheen tulokset analysoitiin tilastollisilla menetelmillä. Potilaiden terveyteen liittyvä elämänlaatu parani ja kipu lievittyi leikkauksen jälkeen ja fyysinen toimintakyky lisääntyi toipumisaikana. Positiivisista muutoksista huolimatta potilaat kokivat ahdistusta samassa määrin kuin ennen leikkaustakin. Palvelujen käyttö vaihteli toipumisajan kuluessa ja potilaiden maksamissa kustannuksissa oli suuria vaihteluita. Fyysisen toimintakyvyn lisääntyminen ja kivun lieveneminen paransivat terveyteen liittyvää elämänlaatua. Sen sijaan huonompi elämänlaatu toipumisaikana oli yhteydessä suurempaan palvelujen käyttöön, kun taas kustannuksilla ei ollut yhteyttä elämänlaatuun. Potilaiden ominaispiirteet tulisi ottaa enemmän huomioon suunniteltaessa sopivaa leikkauksenjälkeistä hoitoa ja tukea. Potilaat tarvitsevat yksilöllisiä ohjeita, sillä monet taustatekijät (esim. ikä, sukupuoli, preoperatiivinen kipu, siviilisääty, ja leikkaustyyppi) vaikuttavat toipumiseen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La planification scanographique (3D) a démontré son utilité pour une reconstruction anatomique plus précise de la hanche (longueur du fémur, centre de rotation, offset, antéversion et rétroversion). Des études ont montré que lors de la planification 2D 50% seulement correspondaient à l'implant définitif du fémur alors que dans une autre étude ce taux s'élevait à 94% pour une planification 3D. Les erreurs étaient liées à l'agrandissement des radiographies. L'erreur sur la taille de la tige est liée à l'estimation inadéquate de la morphologie osseuse ainsi qu'à la densité osseuse. L'erreur de l'antéversion, augmentée par l'inclinaison du bassin, a pu être éliminée par la planification 3D et l'offset restauré dans 98%. Cette étude est basée sur une nouvelle technique de planification scanographique en trois dimensions pour une meilleure précision de la reconstruction de la hanche. Le but de cette étude est de comparer l'anatomie post-opératoire à celle préopératoire en comparant les tailles d'implant prévu lors de la planification 3D à celle réellement utilisée lors de l'opération afin de déterminer l'exactitude de la restauration anatomique avec étude des différents paramètres (centre de rotation, densité osseuse, L'offset fémoral, rotations des implants, longueur du membre) à l'aide du Logiciel HIP-PLAN (Symbios) avec évaluation de la reproductibilité de notre planification 3D dans une série prospective de 50 patients subissant une prothèse totale de hanche non cimentée primaire par voie antérieure. La planification pré-opératoire a été comparée à un CTscan postopératoire par fusion d'images. CONCLUSION ET PRESPECTIVE Les résultats obtenus sont les suivants : La taille de l'implant a été prédit correctement dans 100% des tiges, 94% des cupules et 88% des têtes (longueur). La différence entre le prévu et la longueur de la jambe postopératoire était de 0,3+2,3 mm. Les valeurs de décalage global, antéversion fémorale, inclinaison et antéversion de la cupule étaient 1,4 mm ± 3,1, 0,6 ± 3,3 0 -0,4 0 ± 5 et 6,9 ° ± 11,4, respectivement. Cette planification permet de prévoir la taille de l'implant précis. Position de la tige et de l'inclinaison de la cupule sont exactement reproductible. La planification scanographique préopératoire 3D permet une évaluation précise de l'anatomie individuelle des patients subissant une prothèse totale de hanche. La prédiction de la taille de l'implant est fiable et la précision du positionnement de la tige est excellente. Toutefois, aucun avantage n'est observée en termes d'orientation de la cupule par rapport aux études impliquant une planification 2D ou la navigation. De plus amples recherches comparant les différentes techniques de planification pré-opératoire à la navigation sont nécessaire.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eighteen patients with acetabular fractures, with a mean age of 76 years, were treated with cable fixation and acute total hip arthroplasty. Nine were T-shaped fractures, 4 associated transverse and posterior wall, 2 transverse, 2 posterior column and posterior wall, and 1 anterior and posterior hemitransverse fractures. One patient experienced 3 episodes of hip dislocation within 10 months after surgery. All the others had a good outcome at a mean follow-up time of 36 months. Radiographic assessment showed healing of the fracture and a satisfactory alignment of the cup without loosening. This option provides good primary fixation, stabilizes complex acetabular fractures in elderly patients, and permits early postoperative mobilization.