978 resultados para Total Lung Capacity
Resumo:
Background Asbestosis is associated with lung cellular and immunological abnormalities. Induced sputum cytology and local and systemic markers of inflammation may be helpful to characterize disease status and progression in these patients. Methods Thirty-nine ex-workers with asbestosis on high-resolution CT (HRCT) and 21 non-exposed controls were evaluated. Sputum cytology and IL-8 in serum and sputum were related to lung function impairment. Results Subjects with asbestosis had reduced sputum cellularity but higher macrophagel neutrophil ratio and % macrophage as compared with controls. Sputum and serum IL-8 were also higher in patients with asbestosis (P < 0.05). In addition, evidence of lung architectural distorption on HRCT was associated with increased levels of serum IL-8. Interestingly, absolute macrophage number was negatively correlated with total lung capacity (r = -0.40; P = 0.04) and serum IL-8 to lung diffiusing capacity (r = -0.45; P = 0.01). Conclusions Occupationally exposed subjects with asbestosis on HRCT have cytologic abnormalities in induced sputum and increased local and systemic pro-inflammatory status which are correlated to functional impairment.
Resumo:
Background Airway bypass is a bronchoscopic lung-volume reduction procedure for emphysema whereby transbronchial passages into the lung are created to release trapped air, supported with paclitaxel-coated stents to ease the mechanics of breathing. The aim of the EASE (Exhale airway stents for emphysema) trial was to evaluate safety and efficacy of airway bypass in people with severe homogeneous emphysema. Methods We undertook a randomised, double-blind, sham-controlled study in 38 specialist respiratory centres worldwide. We recruited 315 patients who had severe hyperinflation (ratio of residual volume [RV] to total lung capacity of >= 0.65). By computer using a random number generator, we randomly allocated participants (in a 2:1 ratio) to either airway bypass (n=208) or sham control (107). We divided investigators into team A (masked), who completed pre-procedure and post-procedure assessments, and team B (unmasked), who only did bronchoscopies without further interaction with patients. Participants were followed up for 12 months. The 6-month co-primary efficacy endpoint required 12% or greater improvement in forced vital capacity (FVC) and 1 point or greater decrease in the modified Medical Research Council dyspnoea score from baseline. The composite primary safety endpoint incorporated five severe adverse events. We did Bayesian analysis to show the posterior probability that airway bypass was superior to sham control (success threshold, 0.965). Analysis was by intention to treat. This study is registered with ClinicalTrials.gov, number NCT00391612. Findings All recruited patients were included in the analysis. At 6 months, no difference between treatment arms was noted with respect to the co-primary efficacy endpoint (30 of 208 for airway bypass vs 12 of 107 for sham control; posterior probability 0.749, below the Bayesian success threshold of 0.965). The 6-month composite primary safety endpoint was 14.4% (30 of 208) for airway bypass versus 11.2% (12 of 107) for sham control (judged non-inferior, with a posterior probability of 1.00 [Bayesian success threshold >0.95]). Interpretation Although our findings showed safety and transient improvements, no sustainable benefit was recorded with airway bypass in patients with severe homogeneous emphysema.
Resumo:
In this paper, it was evaluated the total antioxidant capacity (TAC) of beverages using an electrochemical biosensor. The biosensor consisted on the purine base (guanine or adenine) electro-immobilization on a glassy carbon electrode surface (GCE). Purine base damage was induced by the hydroxyl radical generated by Fenton-type reaction. Five antioxidants were applied to counteract the deleterious effects of the hydroxyl radical. The antioxidants used were ascorbic acid, gallic acid, caffeic acid, coumaric acid and resveratrol. These antioxidants have the ability to scavenger the hydroxyl radical and protect the guanine and adenine immobilized on the GCE surface. The interaction carried out between the purinebase immobilized and the free radical in the absence and presence of antioxidants was evaluated by means of changes in the guanine and adenine anodic peak obtained by square wave voltammetry (SWV). The results demonstrated that the purine-biosensors are suitable for rapid assessment of TAC in beverages.
Resumo:
In this paper, a biosensor based on a glassy carbon electrode (GCE) was used for the evaluation of the total antioxidant capacity (TAC) of flavours and flavoured waters. This biosensor was constructed by immobilising purine bases, guanine and adenine, on a GCE. Square wave voltammetry (SWV) was selected for the development of this methodology. Damage caused by the reactive oxygen species (ROS), superoxide radical (O2·−), generated by the xanthine/xanthine oxidase (XOD) system on the DNA-biosensor was evaluated. DNA-biosensor encountered with oxidative lesion when it was in contact with the O2·−. There was less oxidative damage when reactive antioxidants were added. The antioxidants used in this work were ascorbic acid, gallic acid, caffeic acid, coumaric acid and resveratrol. These antioxidants are capable of scavenging the superoxide radical and therefore protect the purine bases immobilized on the GCE surface. The results demonstrated that the DNA-based biosensor is suitable for the rapid assess of TAC in beverages.
Resumo:
In this study, a method for the electrochemical quantification of the total antioxidant capacity (TAC) in beverages was developed. The method is based on the oxidative damage to the purine bases, adenine or guanine, that are immobilized on a glassy carbon electrode (GCE) surface. The oxidative lesions on the DNA bases were promoted by the sulfate radical generated by the persulfate/iron(II) system. The presence of antioxidants on the reactive system promoted the protection of the DNA bases immobilized on the GCE by scavenging the sulfate radical. Square-wave voltammetry (SWV) was the electrochemical technique used to perform this study. The efficiencies of five antioxidants (ascorbic acid, gallic acid, caffeic acid, coumaric acid and resveratrol) in scavenging the sulfate radical and, therefore, their ability to protect the purine bases immobilized on the GCE were investigated. These results demonstrated that the purine-based biosensor is suitable for the rapid assessment of the TAC in flavors and flavored water.
Resumo:
This work measures and tries to compare the Antioxidant Capacity (AC) of 50 commercial beverages of different kinds: 6 wines, 12 beers, 18 soft drinks and 14 flavoured waters. Because there is no reference procedure established for this purpose, three different optical methods were used to analyse these samples: Total Radical trapping Antioxidant Parameter (TRAP), Trolox Equivalent Antioxidant Capacity (TEAC) and Ferric ion Reducing Antioxidant Parameter (FRAP). These methods differ on the chemical background and nature of redox system. The TRAP method involves the transfer of hydrogen atoms while TEAC and FRAP involves electron transfer reactions. The AC was also assessed against three antioxidants of reference, Ascorbic acid (AA), Gallic acid (GA) and 6-hydroxy-2,5,7,8-tetramethyl- 2-carboxylic acid (Trolox). The results obtained were analyzed statistically. Anova one-way tests were applied to all results and suggested that methods and standards exhibited significant statistical differences. The possible effect of sample features in the AC, such as gas, flavours, food colouring, sweeteners, acidity regulators, preservatives, stabilizers, vitamins, juice percentage, alcohol percentage, antioxidants and the colour was also investigated. The AC levels seemed to change with brand, kind of antioxidants added, and kind of flavour, depending on the sample. In general, higher ACs were obtained for FRAP as method, and beer for kind of sample, and the standard expressing the smaller AC values was GA.
Resumo:
The total antioxidant capacity (TAC) of 28 flavoured water samples was assessed by ferric reducing antioxidant potential (FRAP), oxygen radical absorbance capacity (ORAC), trolox equivalent antioxidant capacity (TEAC) and total reactive antioxidant potential (TRAP) methods. It was observed that flavoured waters had higher antioxidant activity than the corresponding natural ones. The observed differences were attributed to flavours, juice and vitamins. Generally, higher TAC contents were obtained on lemon waters and lower values on guava and raspberry flavoured waters. Lower and higher TACs were obtained by TRAP and ORAC method, respectively. Statistical analysis suggested that vitamins and flavours increased the antioxidant content of the commercial waters.
Resumo:
INTRODUCTION: The capacity to overcome the oxidative stress imposed by phagocytes seems to be critical for Candida species to cause invasive candidiasis. METHODS: To better characterize the oxidative stress response (OSR) of 8 clinically relevant Candida sp., glutathione, a vital component of the intracellular redox balance, was measured using the 5,5'-dithiobis-(2-nitrobenzoic acid (DTNB)-glutathione disulfide (GSSG) reductase reconversion method; the total antioxidant capacity (TAC) was measured using a modified method based on the decolorization of the 2,2'-azinobis-(3-ethylbenzothiazoline-6-sulfonic) acid radical cation (ABTS*+). Both methods were used with cellular Candida sp. extracts treated or not with hydrogen peroxide (0.5 mM). RESULTS: Oxidative stress induced by hydrogen peroxide clearly reduced intracellular glutathione levels. This depletion was stronger in Candida albicans and the levels of glutathione in untreated cells were also higher in this species. The TAC demonstrated intra-specific variation. CONCLUSIONS: Glutathione levels did not correlate with the measured TAC values, despite this being the most important non-enzymatic intracellular antioxidant molecule. The results indicate that the isolated measurement of TAC does not give a clear picture of the ability of a given Candida sp. to respond to oxidative stress.
Resumo:
Reduction of the antioxidant capacity of plasma has been linked with the impairment of an effective immune response and so we hypothesized that the carriage rate of Neisseria meningitidis in asymptomatic subjects might correlate with the levels of antioxidants in plasma. To this end we took pharyngeal swabs from 339 children in Marquesado Basic Health Zone, Granada, Spain and in addition determined the total antioxidant capacity (TAC) in plasma samples from these subjects. The overall prevalence of N. meningitidis carriage was 5.9% (mean age 7.1 years) with rates of 10.3% in children aged 3 < or =years, 3.9% between 4 and 7 years and 2.4% in older subjects. Plasma TAC for the < or =3-year-olds was 0.13 for carriers and 1.10 for non-carrier controls (P=0.04), 0.13 for carriers aged 4-7 years (controls 0.63) and 0.28 for carriers aged >7 years (controls 0.52). We analysed the association between TAC in plasma (<0.37 - 2 S.D.) and the carrier state of N. meningitidis. In the carrier state, the odds ratio for this association (TAC in plasma <0.25) was 8.44 (95% CI 1.5-48.9). These findings may suggest a reduced immune response in the host favourable to nasopharyngeal persistence of meningococci.
Resumo:
BACKGROUND The randomized placebo-controlled IFIGENIA-trial demonstrated that therapy with high-dose N-acetylcysteine (NAC) given for one year, added to prednisone and azathioprine, significantly ameliorates (i.e. slows down) disease progression in terms of vital capacity (VC) (+9%) and diffusing capacity (DLco) (+24%) in idiopathic pulmonary fibrosis (IPF). To better understand the clinical implications of these findings we performed additional, explorative analyses of the IFGENIA data set. METHODS We analysed effects of NAC on VC, DLco, a composite physiologic index (CPI), and mortality in the 155 study-patients. RESULTS In trial completers the functional indices did not change significantly with NAC, whereas most indices deteriorated with placebo; in non-completers the majority of indices worsened but decline was generally less pronounced in most indices with NAC than with placebo. Most categorical analyses of VC, DLco and CPI also showed favourable changes with NAC. The effects of NAC on VC, DLco and CPI were significantly better if the baseline CPI was 50 points or lower. CONCLUSION This descriptive analysis confirms and extends the favourable effects of NAC on lung function in IPF and emphasizes the usefulness of VC, DLco, and the CPI for the evaluation of a therapeutic effect. Most importantly, less progressed disease as indicated by a CPI of 50 points or lower at baseline was more responsive to therapy in this study.
Resumo:
This study analyses characteristics of lung injuries produced by alveolar overdistension in three animal species. Mechanical ventilation at normal tidal volume (10 mL/Kg) and high tidal volume (50 mL/Kg) was applied for 30 min in each species. Data were gathered on wet/dry weight ratio, histological score, and area of alveolar collapse. Five out of six rabbits with high tidal volume developed tension pneumothorax, and the rabbit results were therefore not included in the histological analysis. Lungs from the pigs and rats showed minimal histological lesions. Pigs ventilated with high tidal volume had significantly greater oedema, higher neutrophil infiltration, and higher percentage area of alveolar collapse than rats ventilated with high tidal volume. We conclude that rabbits are not an appropriate species for in vivo studies of alveolar overdistension due to their fragility. Although some histological lesions are observed in pigs and rats, the lesions do not appear to be relevant.
Resumo:
Static lung volume (LV) measurements have a number of clinical and research applications; however, no previous studies have provided reference values for such tests using a healthy sample of the adult Brazilian population. With this as our main purpose, we prospectively evaluated 100 non-smoking subjects (50 males and 50 females), 20 to 80 years old, randomly selected from more than 8,000 individuals. Gender-specific linear prediction equations were developed by multiple regression analysis with total lung capacity (TLC), functional residual capacity (FRC), residual volume (RV), RV/TLC ratio and inspiratory capacity (IC) as dependent variables, and with age, height, weight, lean body mass and indexes of physical fitness as independent ones. Simpler demographic and anthropometric variables were as useful as more complex measurements in predicting LV values, independent of gender and age (R2 values ranging from 0.49 to 0.78, P<0.001). Interestingly, prediction equations from North American and European studies overestimated the LV at low volumes and underestimated them at high volumes (P<0.05). Our results, therefore, provide a more appropriate frame of reference to evaluate the normalcy of static lung volume values in Brazilian males and females aged 20 to 80 years.
Resumo:
Background. The best way to study compensatory lung growth (CLG) is in a transplant without rejection. Since immunosuppressive drugs may influence CLG, it is better to not use them. Therefore we studied CLG in a reimplant of only one lobe after its removal. The objective was to compare lobar transplant CLG with CLG after lobectomy.Methods. Forty eight dogs were distributed in three groups: G1 = control, G2 = left cranial lobectomy, and G3 = left pneumonectomy with reimplantation of the caudal lobe. Five months after surgery the animals underwent lung scintigraphy and were sacrificed for morphometric study.Results. There was no correlation between scintigraphy and lung mass or lung volume. There was both mass and residual volume CLG in the operated groups, both contralateral and ipsilateral to surgery. There was no compensation for total lung capacity or compliance in the remaining caudal lobe (G2) or the reimplanted caudal lobe (G3) at 5 months after surgery. There was more damage in the reimplanted lobe. As previous studies have shown that CLG starts with increased mass and residual volume and compliance is compensated later. This study seemed to document the beginning of CLG, with lung compliance being the limiting factor of CLG at 5 months.Conclusion. There was CLG in both the reimplanted lobe and the contralateral lung, but compliance was still reduced. CLG was similar in both groups, but in the implanted lobe compliance was more prejudiced.
Resumo:
Objectives-The purpose of this study was to predict perinatal outcomes using fetal total lung volumes assessed by 3-dimensional ultrasonography (3DUS) in primary pleural effusion.Methods-Between July 2005 and July 2010, total lung volumes were prospectively estimated in fetuses with primary pleural effusion by 3DUS using virtual organ computer-aided analysis software. The first and last US examinations were considered in the analysis. The observed/expected total lung volumes were calculated. Main outcomes were perinatal death (up to 28 days of life) and respiratory morbidity (orotracheal intubation with mechanical respiratory support >48 hours).Results-Twelve of 19 fetuses (63.2%) survived. Among the survivors, 7 (58.3%) had severe respiratory morbidity. The observed/expected total lung volume at the last US examination before birth was significantly associated with perinatal death (P < .01) and respiratory morbidity (P < .01) as well as fetal hydrops (P < .01) and bilateral effusion (P = .01).Conclusions-Fetal total lung volumes may be useful for the prediction of perinatal outcomes in primary pleural effusion.
Resumo:
OBJETIVO: Avaliar se existe crescimento compensatório pulmonar em transplante lobar e verificar se este crescimento é semelhante ao que ocorre após lobectomia. MÉTODOS: Foram utilizados 48 cães, distribuídos em 3 grupos (G1=controle, G2=lobectomia cranial esquerda e G3=pneumonectomia com reimplante do lobo caudal esquerdo). Após 5 meses da cirurgia, os animais foram submetidos à cintilografia pulmonar e a seguir sacrificados para estudo morfométrico pulmonar. RESULTADOS: Os resultados mostraram que não existe correlação da cintilografia nem com a massa nem com o volume do pulmão. Houve crescimento compensatório em massa e volume residual nos dois grupos operados, tanto no pulmão contralateral como no ipsilateral à cirurgia, não existindo até os 5 meses de estudo compensação em capacidade pulmonar total, nem em complacência pulmonar no lobo caudal remanescente do G2 e no lobo caudal reimplantado do G3, havendo maior prejuízo para o lobo reimplantado. Como estudos prévios mostram que o crescimento compensatório pulmonar se inicia com aumento da massa e do volume residual, e que a complacência é compensada posteriormente, este estudo parece ter documentado o início do crescimento compensatório, sendo a complacência pulmonar o fator limitante do crescimento compensatório após 5 meses de estudo. CONCLUSÃO: Conclui-se que existe crescimento compensatório tanto no lobo reimplantado como no pulmão contralateral, mas a complacência ainda encontra-se reduzida. O crescimento compensatório foi semelhante nos dois grupos, mas a complacência do lobo implantado está mais prejudicada.