892 resultados para Tooth Preparation, Prosthodontic
Resumo:
Preclinical and clinical tooth important and significant aspect of preparation is an a dental student's education. The associated procedures rely heavily on the development of particular psychomotor skills. The most common format of instruction and evaluation in tooth preparation at many Dental Faculties, emphasizes the product (tooth preparation) and associates performance with characteristics of this product. This integrated study examines which skills should be developed and how a course of instruction can best be structured to develop the necessary skills. The skills which are identified are those necessary for tooth preparation are selected from a psychomotor taxonomy. The purpose of evaluating these skills is identified. Behavioral objectives are set for student performance and the advisability of establishing standards of performance is examined. After reviewing studies related to learning strategy for dental psychomotor the most suitable tasks as well as articles on instructor effectiveness a model is proposed. A pilot project at the University of Toronto, based on this proposed model is described. The paper concludes wi th a discussion of the implications of this proposed model.
Resumo:
The design of the ParalAB device facilitates transfer of the path of insertion from the diagnostic cast to the mouth quickly and efficiently.
Resumo:
Objective: To investigate the influence of the convergence angle of tooth preparation on the fracture load of Y-TZP-based ceramic (YZ-Vita YZ) substructure (SB) veneered with a feldspathic porcelain (VM9-Vita VM9). Methods: Finite element stress analysis (FEA) was performed to examine the stress distribution of the system. Eighty YZ SB were fabricated using a CAD-CAM system and divided into four groups (n = 20), according to the total occlusal convergence (TOC) angle: G6-6° TOC; G12-12° TOC; G20-20° TOC; and G20MOD-20° TOC with modified SB. All SB were veneered with VM9, cemented in a fiber reinforced epoxy resin die, and loaded to failure. Half of the specimens from each group (n = 10) were cyclic fatigued (106 cycles) before testing. Failure analysis was performed to determine the fracture origin. Data were statistically analyzed using Anova and Tukey's tests (α = 0.05). Results: The greatest mean load to fracture value was found for the G20MOD, which was predicted by the FEA. Cyclic fatigue did not significantly affect the load of fracture. Catastrophic failure originating from the internal occlusal surface of the SB was the predominant failure mode, except for G20MOD. Significance: The YZ-VM9 restorations resisted greater compression load than the usual physiological occlusal load, regardless of the TOC angle of preparations. Yet, the G20MOD design produced the best performance among the experimental conditions evaluated. © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Standardization of measurements for marginal fit of castings is critical. This study describes the fabrication of a device that allowed fixation of specimens on a Toolmakers microscope with identical conditions according to tri-dimensional positioning of specimens, measuring location, and seating force. The device also allows mapping of the marginal discrepancies on the entire marginal perimeter of the tooth preparation.
Resumo:
Utilization of contemporary post and core systems has facilitated the aesthetic restoration of endodontically treated teeth. Light transmission and biocompatibility have been enhanced by the introduction of metal-free post systems. The periodontal and endodontic status, root length, and histological structure of the devitalized teeth must be considered in order to achieve successful restoration following endodontic treatment. This article presents various restorative criteria for the aesthetic placement and buildup of post and core materials, as well as the preservation of maximum coronal and root structure.
Resumo:
The dual path of insertion concept for removable partial denture (RPD) design may be used in esthetically demanding situations. When compared to conventional RPDs, the main advantage of this design is the minimal use of clasps. This clinical report describes the treatment of a patient with an anterior maxillary edentulous area using a dual path RPD. The diagnostic cast was surveyed to ensure the adequacy of the undercuts on the mesial surfaces of the anterior abutments, where rigid minor connectors were placed. Inverted V-shaped canine cingulum rest seats were prepared to provide resistance to tooth movement during function. The dual path RPD concept allows excellent esthetic results, minimizes tooth preparation, and reduces the tendency toward plaque accumulation in a Kennedy class IV partially edentulous arch. © 2008 by The American College of Prosthodontists.
Resumo:
Aim: There is little information considering the framework association between cast clasps and attachments. The aim of this study was to evaluate the retention strength of frameworks match circumferential clasps and extra resilient attachment cast in three different alloys (cobalt-chromium, nickel-chromium titanium and commercially pure titanium), using two undercut (0.25 and 0.75 mm) and considering different period of time (0, 1/2, 1, 2, 3, 4 and 5 years). Methods: Using two metallic matrices, representing a partially edentulous mandibular right hemiarch with the first molar crown, canine root and without premolars, 60 frameworks were fabricated. Three groups (n = 20) of each metal were cast and each group was divided into two subgroups (n = 10), corresponding the molar undercut of 0.25 mm and 0.75 mm. The nylon male was positioned at the matrix and attached to the acrylic resin of the prosthetic base. The samples were subjected to an insertion and removal test under artificial saliva environment. Results: The data were analyzed and compared with ANOVAs and Tukey's test at 95% of probability. The groups cast in cobaltchromium and nickel-chromium-titanium had the highest mean retention strength (5.58 N and 6.36 N respectively) without significant difference between them, but statistically different from the group cast in commercially pure titanium, which had the lowest mean retention strength in all the periods (3.46 N). The association frameworks using nickel-chromium-titanium and cobalt-chromium could be used with 0.25 mm and 0.75 mm of undercut, but the titanium samples seems to decrease the retention strength, mainly in the 0.75 mm undercut. The circumferential clasps cast in commercially pure titanium used in 0.75 mm undercuts have a potential risk of fractures, especially after the 2nd year of use. Conclusion: This in vitro study showed that the framework association between cast clasp and an extra resilient attachment are suitable to the three metals evaluated, but strongly suggest extra care with commercially pure titanium in undercut of 0.75 mm. Clinical significance: Frameworks fabricated in Cp Ti tend to decrease in retentive strength over time and have a potential risk of fracture in less than 0.75 mm of undercut.
Resumo:
Statement of problem. Cavity and tooth preparations generate heat because the use of rotary cutting instruments on dental tissues creates friction. Dental pulps cannot survive temperature increases greater than 5.5degreesC.Purpose. This study evaluated the efficiency of 3 different water flows for 2 different tooth preparation techniques to determine which are safe for use.Material and methods. Thermocouples were placed in the pulpal chambers of 30 bovine teeth, and 1 of 2 tooth preparation techniques was used: a low-load intermittent tooth preparation technique or a high-load tooth preparation technique without intervals. Water flows of 0, 30, and 45 mL/min were associated with each technique, for a total of 6 different groups. The results were analyzed with a 2-factor analysis of variance (P<.05).Results. Temperature increases with the high-load technique were 16.40&DEG;C without cooling (group 1), 11.68&DEG;C with 30 mL/min air-water spray cooling (group III), and 9.96&DEG;C with 45 mL/min cooling (group V). With the low-load tooth preparation technique, a 9.54&DEG;C increase resulted with no cooling (group II), a 1.56&DEG;C increase with 30 mL/min air-water spray cooling (group TV), and a 0.04&DEG;C decrease with 45 mL/min cooling (group VI). The low-load technique was associated with more ideal temperature changes.Conclusion. The results of this study confirm the necessity of using a low-load technique and water coolants during cavity and tooth preparation procedures.
Resumo:
The success rate of resin-bonded fixed partial dentures is directly related to the adhesive system and the tooth preparation design for good retention. These resin-bonded bridges represent a prosthodontic alternative, based on their costeffectiveness, conservative techniques, and ease of laboratory manufacturing. Through a thorough review of the literature, this study aimed to report on cavity designs, types of materials used, and the advantages and disadvantages of the resin-bonded fixed partial denture. One of significant advantages of the resin-bonded fixed partial dentures is the conservation of the tooth structure, whereas its main disadvantage includes aesthetic limitations, given that the alloy may in fact be visible. Preparation design, cement type, and casting alloy type, as well as surface treatment, are among the factors that influence the longevity of resin-bonded fixed partial dentures. Treatments with resin-bonded fixed partial dentures present a bright outlook regarding the conservation of tooth structures, as well as a high level of success.
Resumo:
The treatment of amelogenesis imperfecta (AI) with an anterior open bite (AOB) is a challenge for the clinician and often requires a multidisciplinary team of specialists. Most often, patients suffering from these conditions are young and a good functional and esthetic long-term result must be aspired. This clinical report illustrates the orthodontic, maxillofacial, restorative, and prosthodontic rehabilitation of a 20-year-old woman with a hypoplastic form of AI and an AOB malocclusion, having received treatment for the last 6 years. It included adhesive resin composite restorations, orthodontical and maxillofacial surgery with a one-piece Le Fort I osteotomy, and a genioplasty. Subsequent prosthodontic therapy consisted of 28 all-ceramic crowns whereby a solid interdigitation, a canine guidance, and consistent and regular contacts between tooth crowns could be achieved to assure a good functional and esthetic oral situation. The tooth preparation techniques guaranteed minimally invasive treatment. The patient was affected very positively. CLINICAL SIGNIFICANCE: This article describes an interdisciplinary approach to the successful treatment of a patient with a hypoplastic form of amelogenesis imperfecta over a period of 6 years. It starts with a discussion of the conservative steps taken during adolescence and concludes with the final prosthetic rehabilitation with all-ceramic crowns after reaching adulthood.
Resumo:
A perda de dentes além de afectar a mastigação e a estética, altera também o equilíbrio do sistema estomatognático, observando-se de imediato alterações na posição dos dentes adjacentes e dos dentes oponentes. Torna-se, portanto, imprescindível para a reposição da saúde oral do paciente a reabilitação com recurso a próteses fixas ou removíveis. No que diz respeito às próteses parciais removíveis (PPR´s) estas visam a substituição dos dentes perdidos, sendo facilmente removidas e inseridas pelo paciente, sem qualquer intervenção do médico dentista e, apoiam-se directamente na mucosa e nos dentes. Enquanto as PPR´s acrílicas são suportadas pela mucosa, mediante uma ampla área de contacto, as próteses esqueléticas são suportadas pelos dentes pilares através da colocação de retentores. No caso específico das PPR´s, é fundamental que o profissional de saúde tenha em consideração a importância do planeamento correcto e adequado da reabilitação oral. Para isso, pode e deve utilizar o paralelómetro, determinando assim correctamente a localização dos planos-guia, dos apoios e retentores necessários. Guiando-se por estes princípios fundamentais, qualquer reabilitação com recurso às PPR´s pode ser bem sucedida quer a nível estético quer a nível funcional.
Resumo:
Objectives To compare the reliability of the disto-facial (DF) and mesio-lingual (ML) cusps of an anatomically correct zirconia (Y-TZP) crown system The research hypotheses tested were (1) fatigue reliability and failure mode are similar for the ML and DF cusps, (2) failure mode of one cusp does not affect the failure of the other Methods The average dimensions of a mandibular first molar crown were imported into CAD software, a tooth preparation was modelled by 1 5 mm marginal high reduction of proximal walls and occlusal surface by 2 0 mm The CAD-based tooth preparation was milled and used as a die to fabricate crowns (n = 14) with porcelain veneer on a 0 5 mm Y-TZP core. Crowns were cemented on composite reproductions of the tooth preparation The crowns were step-stress mouth motion fatigued with sliding (0 7 mm) a tungsten-carbide indenter of 6 25 mm diameter down on the inclines of either the DF or ML cusps Use level probability Weibull curve with use stress of 200 N and the reliability for completion of a mission of 50,000 cycles at 200 N load were calculated Results Reliability for a 200 N at 50,000 cycles mission was not different between tested cusps SEM imaging showed large cohesive failures within the veneer for the ML and smaller for the DF Fractures originated from the contact area regardless of the cusp loaded Conclusion No significant difference on fatigue reliability was observed between the DF compared to the ML cusp Fracture of one cusp did not affect the other (c) 2010 Elsevier Ltd All rights reserved
Resumo:
This study evaluated the stress levels at the core layer and the veneer layer of zirconia crowns (comprising an alternative core design vs. a standard core design) under mechanical/thermal simulation, and subjected simulated models to laboratory mouth-motion fatigue. The dimensions of a mandibular first molar were imported into computer-aided design (CAD) software and a tooth preparation was modeled. A crown was designed using the space between the original tooth and the prepared tooth. The alternative core presented an additional lingual shoulder that lowered the veneer bulk of the cusps. Finite element analyses evaluated the residual maximum principal stresses fields at the core and veneer of both designs under loading and when cooled from 900 degrees C to 25 degrees C. Crowns were fabricated and mouth-motion fatigued, generating master Weibull curves and reliability data. Thermal modeling showed low residual stress fields throughout the bulk of the cusps for both groups. Mechanical simulation depicted a shift in stress levels to the core of the alternative design compared with the standard design. Significantly higher reliability was found for the alternative core. Regardless of the alternative configuration, thermal and mechanical computer simulations showed stress in the alternative core design comparable and higher to that of the standard configuration, respectively. Such a mechanical scenario probably led to the higher reliability of the alternative design under fatigue.
Resumo:
Despite the increasing utilization of all-ceramic crown systems, their mechanical performance relative to that of metal ceramic restorations (MCR) has yet to be determined. This investigation tested the hypothesis that MCR present higher reliability over two Y-TZP all-ceramic crown systems under mouth-motion fatigue conditions. A CAD-based tooth preparation with the average dimensions of a mandibular first molar was used as a master die to fabricate all restorations. One 0.5-mm Pd-Ag and two Y-TZP system cores were veneered with 1.5 mm porcelain. Crowns were cemented onto aged (60 days in water) composite (Z100, 3M/ESPE) reproductions of the die. Mouth-motion fatigue was performed, and use level probability Weibull curves were determined. Failure modes of all systems included chipping or fracture of the porcelain veneer initiating at the indentation site. Fatigue was an acceleration factor for all-ceramic systems, but not for the MCR system. The latter presented significantly higher reliability under mouth-motion cyclic mechanical testing.