17 resultados para Thermogram


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The scanning thermogram of a block sample of a double-base propellant shows a shoulder around 200°C which is not observed in a powder sample of the sample propellant. The heat of decomposition was also found to be different In the two cases. Product analysis and activation energy calculations show that nitroglycerine un dergoes decomposition in the block sample, whereas it vaporizes in the powder sample.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lithium rubidium sulphate, LiRbSO4 (LRS), undergoes a sequence of four phase transitions at 166, 185, 202 and 204°C. The phase between 202 and 204°C is incommensurate. Polarized phonon Raman spectra in the frequency region of 50-1200 cm-1 are presented to identify the external and internal vibrational modes at room temperature. The internal mode frequencies of the sulphate ions are presented in the temperature region from -150 to 230°C covering all the phase transitions. The total integrated areas of the 1, 2 and 4 modes show an anomalous increase across the phase transitions. The frequencies of the symmetric stretching (1) and symmetric bending (2) modes do not show any changes at the phase transitions, but the width of the 2 mode shows changes across the phase transitions. A small increase in the linewidth of the 2 mode observed in the incommensurate phase is attributed to the influence of the incommensurate modulation wave. A DSC thermogram showed endothermic peaks during heating at all the phase transitions. The IR spectrum recorded at room temperature showed the expected Au and Bu internal modes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fenvalerate is a commonly used pyrethroid insecticide, used to control a wide range of pests. We have studied its interaction with the membrane using fluorescence polarization and differential scanning calorimetry (DSC) techniques. Fenvalerate was found to decrease the DPH fluorescence polarization value of synaptosomal and microsomal membrane, implicating that it makes the membrane more fluid. At different concentrations of fenvalerate, the activation energy of the probe molecule in the membrane also changes revealed from the change in slope of the Arrhenius plot. At higher concentrations the insecticide slowly saturates the membrane. The effects of fenvalerate on model membrane were also studied with liposomes reconstituted with dipalmitoylphosphatidylcholine (DPPC). Fenvalerate decreased the phase transition temperature (Tm) of DPPC by 1.5 °C at 40 μM concentration, but there was no effect on the cooperativity of the transition as interpreted from the DSC thermogram. From the change in the thermogram profile with fenvalerate it has been interpreted that it localizes in the acyl chain region of the lipid, possibly between C10 and C16 region and weakens the acyl chain packing. Fenvalerate was also found to interact with DPPC liposomes containing cholesterol to fluidize it.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The melting behavior of semicrystalline poly(ether ether ketone ketone) (PEEKK) has been studied by differential scanning calorimetry (DSC). When PEEKK is annealed from the amorphous state, it usually shows two melting peaks. The upper melting peaks arise first, and the lower melting peaks are developed later. The upper melting peaks shown in the DSC thermogram are the combination (addition) of three parts: initial crystal formed before scanning; reorganization; and melting-recrystallization of lower melting peaks in the DSC scanning period. In the study of isothermal crystallization kinetics, the Avrami equation was used to analyze the primary process of the isothermal crystallization; the Avrami constant, n, is about 2 for PEEKK from the melt and 1.5 for PEEKK from the glass state. According to the Lauritzen-Hoffman equation, the kinetic parameter of PEEKK from the melt is 851.5 K; the crystallization kinetic parameter of PEEKK is higher than that of PEEK, and suggests the crystallizability of PEEKK is less than that of PEEK. The study of crystallization on PEEKK under nonisothermal conditions is also reported for cooling rates from 2.5 degrees C/min to 40 degrees C/min, and the nonisothermal condition was studied by Mandelkern analysis. The results show the nonisothermal crystallization is different from the isothermal crystallization. (C) 1996 John Wiley & Sons, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As galactomananas das infusões de café apresentam atividade imunoestimuladora in vitro, sendo esta atividade semelhante à das mananas acetiladas extraídas de Aloe vera. As galactomananas presentes no resíduo de café também possuem atividade imunoestimuladora in vitro quando são parcialmente acetiladas. Como as galactomananas são o componente maioritário do resíduo de café e como o café é um produto de largo consumo a nível mundial, o reaproveitamento deste resíduo como fonte de galactomananas com atividade imunoestimuladora deve ser considerado. Esta dissertação procura dar resposta a duas questões: 1. Quais são as estruturas das galactomananas responsáveis pela atividade imunoestimuladora destes polissacarídeos; e 2. Como é que as galactomananas podem ser extraídas quantitativamente do resíduo de café de modo a serem solúveis em água à temperatura ambiente e, assim, poderem ser utilizadas como ingredientes alimentares com atividade imunoestimuladora. A questão 1 foi respondida pela caracterização estrutural de quatro galactomananas, de três origens: a) as galactomananas das infusões de café e do resíduo que apresentaram atividade imunoestimuladora; b) a galactomanana da goma de alfarroba (LBG), que não apresentou atividade imunoestimuladora; e c) a manana acetilada de Aloe vera, que apresentou atividade imunoestimuladora. Estes polissacarídeos foram submetidos à análise de açúcares e de ligações glicosídicas e a hidrólise por endo-β-D- (1→4)-mananase. Os fragmentos de oligossacarídeos mais pequenos foram ainda analisados por espetrometria de massa por ionização de electrospray e espetrometria de massa tandem. As galactomananas das infusões de café, do resíduo de café e do Aloe vera apresentaram grau de ramificação e peso molecular semelhantes, enquanto as galactomananas da LBG apresentaram grau de ramificação e de polimerização maiores. Todas as galactomananas apresentaram resíduos de arabinose como ramificação. O grau de acetilação das galactomananas da LBG foi vestigial enquanto as galactomananas do Aloe vera apresentaram um grau de acetilação de 2,08; para as galactomananas do resíduo de café o grau de acetilação foi de 0,98 e para as infusões foi de 0,08. A localização dos grupos acetilo foi irregular em todos os polímeros. Os resultados obtidos permitem inferir que baixos níveis de ramificação, cadeias pequenas e alguma acetilação parecem promover a atividade imunoestimuladora atribuída às galactomananas. Para responder à questão 2, foi testada uma metodologia que envolveu a torra do resíduo de café a 160 ºC e a 220 ºC e a sua extração com água quente e com soluções de 4 M NaOH à temperatura de 20, 60 e 120 ºC. A torra do resíduo a 160 ºC e a extração sequencial permitiu extrair 56% das galactomananas presentes no resíduo de café e, simultaneamente, 54% das arabinogalactanas. As galactomananas mantiveram a sua estrutura caraterística de polissacarídeo acetilado composto por uma cadeira principal de resíduos de manose em ligação β-(1→4) e resíduos de Gal e Ara nas cadeias laterais. A 220 ºC, as galactomananas foram parcialmente degradadas e o rendimento de extração foi muito menor do que a 160 ºC. No entanto, mesmo a esta temperatura as galactomananas apresentaram resíduos acetilados e a presença de pentoses nas cadeias laterais, o que permite inferir a elevada resistência destes polissacarídeos à temperatura e aos reagentes alcalinos. De forma a melhor compreender a estabilidade térmica das galactomananas do resíduo de café e a influência que a presença de arabinogalactanas pode ter na sua estabilidade, foi feita uma análise termogravimétrica aos polissacarídeos extraídos do resíduo de café assim como a polissacarídeos relacionados estruturalmente com estes, como a celulose, a galactomanana de LBG e a goma arábica, uma arabinogalactana. As galactomananas são termicamente estáveis durante 3 h a 200 ºC, enquanto as arabinogalactanas são estáveis a 180 ºC. De acordo com os perfis dos termogramas obtidos, e pelo cálculo das energias de ativação da degradação térmica, o resíduo de café apresenta uma estabilidade térmica menor do que a galactomanana, possivelmente devido à presença de arabinogalactanas. Apesar de não se ter verificado alterações no termograma da galactomanana do café submetida a um tratamento térmico de 200 ºC durante 3 h, verificam-se alterações estruturais que envolvem a formação de novas ligações glicosídicas, nomeadamente, a formação de resíduos de manose ligados em O-2 e em O-6, reações de transglicosilação, despolimerização, formação de resíduos de anidro-hexoses no terminal redutor e isomerização manose-glucose. Estas alterações promovem a solubilização das galactomananas. Os resultados obtidos permitem propor que o resíduo de café possa ser submetido a uma torra seguida de extração com reagentes alcalinos a quente para obtenção das galactomananas com rendimentos elevados. Estes polissacarídeos podem tornar-se solúveis em água após tratamento térmico a 200 ºC, permitindo assim a sua utilização em formulações alimentares, nomeadamente, por preparação de compostos acetilados com baixos níveis de ramificação e cadeias pequenas de modo a promover a sua atividade imunoestimuladora.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A civilização contemporânea, pelas suas características, é muito exigente em tudo o que diz respeito ao conforto dos edifícios, para trabalho ou habitação, e à necessidade de economizar e racionalizar o uso de energia. A térmica dos edifícios assume, por isso, uma importância acrescida na atividade profissional e no ensino. Para se conduzir ao aperfeiçoamento de soluções na envolvente dos edifícios a este nível, o trabalho aqui realizado centrou-se no estudo do funcionamento da termografia de infravermelhos e da importância da sua utilização na inspeção térmica de edifícios. Descoberta no início do século XIX e desenvolvendo os primeiros sistemas operativos desde a 1ª Guerra Mundial, a fim de determinar heterogeneidades de temperatura superficial, esta técnica não destrutiva permite identificar anomalias que não são visualizadas a olho nu. Com a análise dessas variações de temperatura é possível conhecer os problemas e a localização de irregularidades. Este trabalho baseia-se substancialmente no estudo de edifícios. A análise realizada teve como finalidade executar inspeções termográficas – visuais, com duas abordagens. Por um lado, avaliar salas pertencentes a estabelecimentos de ensino secundário, reabilitadas e não reabilitadas, todas construídas entre as décadas de 60 e 90, com o intuito de diagnosticar patologias construtivas, recorrendo à termografia. Por outro, a análise de edifícios de habitação, com a intenção de avaliar a necessidade de um equipamento complementar às inspeções termográficas – o sistema de porta ventiladora. As inspeções foram regidas pelas diretrizes da norma europeia EN 13187. A termografia é uma técnica importante na realização de ensaios in situ que requerem rapidez de execução, aliada à vantagem de disponibilizar resultados em tempo real, permitindo assim uma primeira análise das leituras no local. A inspeção termográfica complementada com o sistema de porta ventiladora permitiu, também, revelar a importância da necessidade de meios auxiliares em certos casos. A conjugação destas diferentes técnicas permite reduzir a subjetividade da análise in situ e aumentar a fiabilidade do diagnóstico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Automatic face recognition is an area with immense practical potential which includes a wide range of commercial and law enforcement applications. Hence it is unsurprising that it continues to be one of the most active research areas of computer vision. Even after over three decades of intense research, the state-of-the-art in face recognition continues to improve, benefitting from advances in a range of different research fields such as image processing, pattern recognition, computer graphics, and physiology. Systems based on visible spectrum images, the most researched face recognition modality, have reached a significant level of maturity with some practical success. However, they continue to face challenges in the presence of illumination, pose and expression changes, as well as facial disguises, all of which can significantly decrease recognition accuracy. Amongst various approaches which have been proposed in an attempt to overcome these limitations, the use of infrared (IR) imaging has emerged as a particularly promising research direction. This paper presents a comprehensive and timely review of the literature on this subject. Our key contributions are (i) a summary of the inherent properties of infrared imaging which makes this modality promising in the context of face recognition; (ii) a systematic review of the most influential approaches, with a focus on emerging common trends as well as key differences between alternative methodologies; (iii) a description of the main databases of infrared facial images available to the researcher; and lastly (iv) a discussion of the most promising avenues for future research. © 2014 Elsevier Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have investigated the effect of mixing spontaneously formed dispersions of the cationic vesicle-forming dioctadecyldimethylammonium chloride and bromide (DODAX, with X being anions Cl- (C) or Br- (B)) with solutions of the micelle-forming nonionic ethylene oxide surfactants penta-, hepta-, and octaethyleneglycol mono-n-dodecyl ether, C12En (n = 5, 7, and 8), and the zwitterionic 3-(N-hexadecyl-N,N-dimethylammonio)propane sulfonate (HPS). We used for this purpose differential scanning calorimetry (DSC), turbidity, and steady-state fluorescence spectroscopy to investigate the vesicle-micelle (V-M) transition yielded by adding C12En and HPS to 1.0 mM vesicle dispersions of DODAC and DODAB. The addition of these surfactants lowers the gel-to-liquid crystalline phase transition temperature (T-m) of DODAC and DODAB, and the transition becomes less cooperative, that is, the thermogram transition peak shifts to lower temperature and broadens to disappear when the V-M transition is complete, the vesicle bilayer becomes less organized, and the T., decreases, in agreement with measurements of the fluorescence quantum yield of trans-diphenylpolyene (t-DPO) fluorescence molecules incorporated in the vesicle bilayer. Turbidity data indicate that the V-M transition comes about in three stages: first surfactants are solubilized into the vesicle bilayer; after saturation, the vesicles are ruptured, and, finally, the vesicles are completely solubilized and only mixed micelles are formed. The critical points of bilayer saturation and vesicle solubilization were obtained from the turbidity and fluorescence curves, and are reported in this communication. The solubility of DODAX is stronger for C12En than it is for HPS, meaning that C12En solubilizes DODAX more efficiently than does HPS. The surfactant solubilization depends slightly on the counterion, and varies according to the sequence C12E5 > C12E7 > C12E8 > HPS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Low density silica sonogels were prepared from acid sonohydrolysis of tetraethoxysilane. Wet gels were studied by small-angle x-ray scattering (SAXS) and differential scanning calorimetry (DSC). The DSC tests were carried out under a heating rate of 2 degrees C/min from -120 degrees C up to 30 degrees C. Aerogels were obtained by CO(2) supercritical extraction and characterized by nitrogen adsorption and SAXS. The DSC thermogram displays two distinct endothermic peaks. The first, a broad peak extending from about -80 degrees C up to practically 0 degrees C, was associated to the melting of ice nanocrystals with a crystal size distribution with pore diameter ranging from 1 or 2 nm up to about 60 nm, as estimated from Thomson's equation. The second, a sharp peak with onset temperature close to 0 degrees C, was attributed to the melting of macroscopic crystals. The DSC incremental nanopore volume distribution is in reasonable agreement with the incremental pore volume distribution of the aerogel as determined from nitrogen adsorption. No macroporosity was detected by nitrogen adsorption, probably because the adsorption method applies stress on the sample during measurement, leading to a underestimation of pore volume, or because often positive curvature of the solid surface is in aerogels, making the nitrogen condensation more difficult. According to the SAXS results, the solid network of the wet gels behaves as a mass fractal structure with mass fractal dimension D=2.20 +/- 0.01 in a characteristic length scale below xi=7.9 +/- 0.1 nm. The mass fractal characteristics of the wet gels have also been probed from DSC data by means of an earlier applied modeling for generation of a mass fractal from the incremental pore volume distribution curves. The results are shown to be in interesting agreement with the results from SAXS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Biofísica Molecular - IBILCE

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aimed to study the relationship between scrotal temperature on semen quality by use of infrared thermography in Nelore bulls bred extensively. There were scrotal thermography and semen collection. Climatic data were collected by means of globe thermometer. The thermograms of the scrotum were obtained by digital infrared thermography. We carried out ejaculates through electroejaculation for analysis of quantitative and qualitative characteristics. For the data, we used analysis of variance and subsequently applied the Tukey test at 5%. (p <0.05) between animals for sperm vigor, sperm motility between animals and between crops, sperm concentration, total sperm and total viable sperm between groups, between harvests for the scrotum temperatures and climate data. It was concluded that the surface temperatures of the scrotum and climatic factors influence the quality of semen. Thermography is recommended as a complementary test in the evaluation of reproductive bulls.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In recent years, the use of Reverse Engineering systems has got a considerable interest for a wide number of applications. Therefore, many research activities are focused on accuracy and precision of the acquired data and post processing phase improvements. In this context, this PhD Thesis deals with the definition of two novel methods for data post processing and data fusion between physical and geometrical information. In particular a technique has been defined for error definition in 3D points’ coordinates acquired by an optical triangulation laser scanner, with the aim to identify adequate correction arrays to apply under different acquisition parameters and operative conditions. Systematic error in data acquired is thus compensated, in order to increase accuracy value. Moreover, the definition of a 3D thermogram is examined. Object geometrical information and its thermal properties, coming from a thermographic inspection, are combined in order to have a temperature value for each recognizable point. Data acquired by an optical triangulation laser scanner are also used to normalize temperature values and make thermal data independent from thermal-camera point of view.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La termografía es un método de inspección y diagnóstico basado en la radiación infrarroja que emiten los cuerpos. Permite medir dicha radiación a distancia y sin contacto, obteniendo un termograma o imagen termográfica, objeto de estudio de este proyecto. Todos los cuerpos que se encuentren a una cierta temperatura emiten radiación infrarroja. Sin embargo, para hacer una inspección termográfica hay que tener en cuenta la emisividad de los cuerpos, capacidad que tienen de emitir radiación, ya que ésta no sólo depende de la temperatura del cuerpo, sino también de sus características superficiales. Las herramientas necesarias para conseguir un termograma son principalmente una cámara termográfica y un software que permita su análisis. La cámara percibe la emisión infrarroja de un objeto y lo convierte en una imagen visible, originalmente monocromática. Sin embargo, después es coloreada por la propia cámara o por un software para una interpretación más fácil del termograma. Para obtener estas imágenes termográficas existen varias técnicas, que se diferencian en cómo la energía calorífica se transfiere al cuerpo. Estas técnicas se clasifican en termografía pasiva, activa y vibrotermografía. El método que se utiliza en cada caso depende de las características térmicas del cuerpo, del tipo de defecto a localizar o la resolución espacial de las imágenes, entre otros factores. Para analizar las imágenes y así obtener diagnósticos y detectar defectos, es importante la precisión. Por ello existe un procesado de las imágenes, para minimizar los efectos provocados por causas externas, mejorar la calidad de la imagen y extraer información de las inspecciones realizadas. La termografía es un método de ensayo no destructivo muy flexible y que ofrece muchas ventajas. Por esta razón el campo de aplicación es muy amplio, abarcando desde aplicaciones industriales hasta investigación y desarrollo. Vigilancia y seguridad, ahorro energético, medicina o medio ambiente, son algunos de los campos donde la termografía aportaimportantes beneficios. Este proyecto es un estudio teórico de la termografía, donde se describen detalladamente cada uno de los aspectos mencionados. Concluye con una aplicación práctica, creando una cámara infrarroja a partir de una webcam, y realizando un análisis de las imágenes obtenidas con ella. Con esto se demuestran algunas de las teorías explicadas, así como la posibilidad de reconocer objetos mediante la termografía. Thermography is a method of testing and diagnosis based on the infrared radiation emitted by bodies. It allows to measure this radiation from a distance and with no contact, getting a thermogram or thermal image, object of study of this project. All bodies that are at a certain temperature emit infrared radiation. However, making a thermographic inspection must take into account the emissivity of the body, capability of emitting radiation. This not only depends on the temperature of the body, but also on its surface characteristics. The tools needed to get a thermogram are mainly a thermal imaging camera and software that allows analysis. The camera sees the infrared emission of an object and converts it into a visible image, originally monochrome. However, after it is colored by the camera or software for easier interpretation of thermogram. To obtain these thermal images it exists various techniques, which differ in how heat energy is transferred to the body. These techniques are classified into passive thermography, active and vibrotermografy. The method used in each case depends on the thermal characteristics of the body, the type of defect to locate or spatial resolution of images, among other factors. To analyze the images and obtain diagnoses and defects, accuracy is important. Thus there is a image processing to minimize the effects caused by external causes, improving image quality and extract information from inspections. Thermography is a non-­‐destructive test method very flexible and offers many advantages. So the scope is very wide, ranging from industrial applications to research and development.Surveillance and security, energy saving, environmental or medicine are some of the areas where thermography provides significant benefits. This project is a theoretical study of thermography, which describes in detail each of these aspects. It concludes with a practical application, creating an infrared camera from a webcam, and making an analysis of the images obtained with it. This will demonstrate some of the theories explained as well as the ability to recognize objects by thermography.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

From the last decades, infrared thermography is quite often associated with things other than clinical medicine. For example, the chemical, automobile, aeronautic industries and civil engineering. However, thermography is where infrared images of the breast are analyzed by board certified thermographers and an abnormal thermogram is reported as the significant risk for the existence of breast tumor (Ng, 2009). Thermography is a painless, noninvasive, no radiation, as well as being cheaper and faster, easier access. The aim of this review was to identify the views of clinicians on the use of thermography for quantifying the risk of breast cancer. We used articles published recently in a reliable database. Thermography has been convicted over the years; it has been labeled by subjective interpretation. Most of the reviewed articles agree that mammography is currently the main examination chosen by doctors for the screening of breast cancer (Acharya et al., 2010; Kennedy et al., 2009). However, several studies have reported promising results for the technique (Wang et al., 2010). Additionally, some authors suggest that thermography is complementary to other diagnostic methods, and that the best strategy for the early detection of breast cancer would be to use them together (Kennedy et al., 2009; Hersh, 2004). The combination of thermal imaging with other tests would increase accuracy, sensitivity and specificity of the evaluation and allow a better quantification of the risk of breast cancer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Les stérosomes, des vésicules artificielles composées d’amphiphiles monoalkylés et d’un grand pourcentage de stérols, sont prometteurs dans plusieurs domaines comme les industries pharmaceutiques et alimentaires. Il existe des stérosomes chargés négativement, positivement et neutres. Dans ce mémoire, nous avons approfondi nos connaissances sur les propriétés physico-chimiques des stérosomes chargés : acide palmitique (PA)/stérol et stéarylamine (SA)/cholestérol (Chol). Premièrement, afin de mesurer la diffusion latérale de PA dans les membranes PA/stérol (30/70 mol/mol) par RMN à gradients pulsés, nous avons tenté de former des bicouches liquide-ordonnées (lo) orientées magnétiquement avec ce mélange. En s'inspirant de l’idée que l’ajout de 1,2-dihexanoyl-sn-glycéro-3-phosphocholine (DHPC), un lipide à courtes chaînes, dans le système 1,2-dimyristoyl-sn-glycéro-3-phosphocholine (DMPC) mène à la formation de bicouches orientées, nous avons étudié la formulation PA perdeutéré/acide hexanoïque (HA)/Chol avec une proportion molaire de 25/18/57 à plusieurs températures; aucune formation de bicouches orientées n’a été observée. Ce résultat pourrait être expliqué par la solubilisation partielle de HA en milieu aqueux. Alors, une quantité insuffisante serait insérée dans la bicouche pour induire son orientation. La formulation PA perdeutéré/DHPC/Chol n’a pas conduit, elle non plus, à des bicouches orientées magnétiquement à des températures et concentrations lipidiques variées. En étudiant le mélange DMPC/DHPC/Chol (67/17/14), nous avons remarqué que la présence de Chol inhibait l'orientation magnétique des bicouches. Tandis que le mélange DMPC/DHPC/stigmastérol (SS) avec les proportions molaires 67/19/14 et 72/21/7 conduisait à des bicouches orientées avec leur normale (n) perpendiculaire au champ magnétique à 40 °C et 50 °C. Ces résultats suggèrent que le mélange PA/SS avec une proportion de lipide à courtes chaînes, HA et DHPC, pourrait mener à des bicouches orientées magnétiquement. Le mélange PA/Chol avec un lipide à courtes chaînes pourrait aussi être étudié en présence des lanthanides. Deuxièmement, nous avons examiné la possibilité de moduler la libération de matériel encapsulé dans des liposomes essentiellement composés de PA et d’un stérol. Il est connu que le mélange PA/Chol (30/70) à pH ≥ 7,5 forme des liposomes très peu perméables. Il est avantageux de pouvoir moduler la perméabilité pour avoir un contrôle sur le temps de libération de leur contenu, qui est un paramètre de grande importance pour les formulations liposomales de médicaments. D’abord, il a été montré que l’acide oléique (OA)/Chol (30/70) est capable de former des vésicules, ce qui n’avait jamais été prouvé auparavant. Par contre, les bicouches OA/Chol (30/70) ne sont pas plus perméables que les bicouches PA/Chol (30/70). L’ajout de 1-palmitoyl-2-oléoyl-sn-glycéro-3-phosphatidylcholine (POPC) dans le mélange PA/Chol n’augmente pas plus la perméabilité. En effet, les cinétiques de relargage de calcéine des vésicules PA/POPC/Chol (15/27.5/57.5), POPC/Chol (40/60) et POPC étaient très semblables à celle de PA/Chol (30/70). Il a été remarqué que les études littéraires se contredisent à propos de la perméabilité à la calcéine des bicouches de phosphatidylcholine (PC). L’explication de ces divergences est inconnue pour le moment. En remplaçant la moitié de la proportion molaire de Chol par le cholate de sodium (SC) dans le mélange PA/Chol (30/70), la membrane n’était pas plus apte à libérer son contenu. Il se pourrait que le SC se retrouvant dans la bicouche n’induit pas une diminution d’empilement. Il est aussi possible que le SC ne s'insère pas dans la membrane à cause de son hydrophilie considérable et il pourrait alors former seul des micelles. En remplaçant complètement le Chol par le sulfate de cholestérol (SChol), un stérol chargé négativement, et en préparant les vésicules à un bas pH, la formulation PA/SChol (30/70) mène à une très grande perméabilité à pH 7.5; le relargage est provoqué par un saut de pH. Nos travaux suggèrent qu'il serait possible de moduler la perméabilité des liposomes en les préparant avec le mélange PA/SChol/Chol en variant les proportions entre 30/63/7 à 30/70/0. Le diagramme pH-composition du mélange PA/SChol/Chol indique que ces proportions conduisent, à pH 7.4, à la coexistence de phases solide et lo en différentes proportions, ce qui pourrait moduler la perméabilité membranaire. Troisièmement, les résultats de perméabilité obtenus avec la calcéine et les difficultés survenues lors de l’extrusion des vésicules encapsulant cette sonde nous ont amené à nous demander si la calcéine interagit avec les bicouches chargées. L’impact de certains anions, dont la calcéine, a été examiné sur les bicouches chargées positivement SA/Chol (50/50). La calorimétrie différentielle à balayage (DSC, de l’anglais differential scanning calorimetry), indique qu’il n’y a aucune transition entre 25 et 90 °C pour les liposomes SA/Chol (50/50) à pH = 7.4. L’ajout de chlorure de sodim (375 mM) n’a pas mené à la formation d’agrégats et aucune transition n’a été observée sur le thermogramme. La formation d’agrégats macroscopiques instantanément après l’ajout d’hydrogénophosphate de sodium (125 mM), de sulfate de sodium (125 mM) et de calcéine (3 mM) a été observée. Une transition a été observée sur les thermogrammes en présence de ces sels. Les agrégats observés pourraient être associés à la transition de phase. L’effet des anions sur la température et l’enthalpie de transition suivent le même ordre que la série d’Hofmeister : sulfate > hydrogénophosphate > chlorure (pas de pic). La calcéine avait l’impact le plus prononcé sur l’agrégation; ceci illustre que la calcéine n’est pas une sonde fluorescente inerte avec le mélange SA/Chol. Elle pourrait être un chaotrope volumineux. De plus, les interactions SA-calcéine plus fortes, menant à l’agrégation des vésicules, que les interactions PC-calcéine pourraient s’expliquer par le fait que la SA est chargée positivement.