This study was conducted to determine the relationship among temperatures measured at different anatomical sites of the animal body and their daily pattern as indicative of the thermal stress in lactating dairy cows under tropical conditions. Environmental dry bulb (DBT) and black globe (BGT) temperatures and relative humidity (RH) were recorded. Rectal temperature (RT), respiratory frequency (RF), body surface (BST), internal base of tail (TT), vulva (VT) and auricular temperatures (AT) were collected, from 37 Black and White Holstein cows at 0700, 1300 and 1800 hours. RT showed a moderately and positive correlations with all body temperatures, ranging from 0.59 with TT to 0.64 with BST. Correlations among AT, VT and TT with RF were very similar (from 0.63 to 0.64) and were greater than those observed for RF with RT (0.55) or with BST (0.54). RF and RT were positively correlated to TT (0.63 and 0.59, respectively), AT (r = 0.63 for both) and VT (r = 0.64 and 0.63, respectively). Positive and very high correlations were observed among AT, VT and TT (from 0.94 to 0.97) indicating good association of temperatures measured in these anatomical sites. Correlations of BST with AT and VT were positive and very similar (0.71 and 0.72, respectively) and lower with TT (0.66). The AT, TT, VT and BST presented similar patterns and follow the variations of DBT through the day. Temperatures measured at different anatomical sites of the animal body have the potential to be used as indicative of the thermal stress in lactating dairy cows.
Resumo:
Aim and objectives To identify the prevalence that temperature reduced by more than 1°C from pre to post-procedure in a sample of non-anaesthetised patients undergoing procedures in a cardiac catheterisation laboratory. Background Advances in medical technology are minimising the invasiveness of diagnostic tests and treatments for disease, which is correspondingly increasing the number of medical procedures performed without sedation or anaesthesia. Procedural areas in which medical procedures are performed without anaesthesia are typically kept at a cool temperature for staff comfort. As such, there is a need to inform nursing practices in regard to the thermal management of non-anaesthetised patients undergoing procedures in surgical or procedural environments. Design Single-site observational study Methods Patients were included if they had undergone an elective procedure without sedation or anaesthesia in a cardiac catheterisation laboratory. Ambient room temperature was maintained between 18°C and 20°C. Passive warming with heated cotton blankets was applied. Nurses measured body temperature and thermal comfort before and after 342 procedures. Results Mean change in temperature was -0.08°C (Standard deviation 0.43). The reduction in temperature was more than 1°C after 11 procedures (3.2%). One patient whose temperature had reduced more than 1°C after their procedure reported thermal discomfort. A total of 12 patients were observed to be shivering post-procedure (3.6%). No demographic or clinical characteristics were associated with reduction in temperature of more than 1°C from pre to post-procedure. Conclusions Significant reduction in body temperature was rare in our sample of non-anaesthetised patients. Relevance to clinical practice Similar results would likely be found in other procedural contexts during procedures conducted in settings with comparable room temperatures where passive warming can also be applied with limited skin exposure.
Resumo:
Goat breeding in the state of Rio Grande do Norte, Brazil has promising economic possibilities, with the proper handling of the natural resources. The introduction of specialized animals has been one of the ways used to improve herd genetics and increase productivity. However, climate has been one of the regional factors that most interferes with the adaptation of the new genetic prevalence resulting from the introduction of exotic breeds, because in their country of origin, the air temperature during most of the year is lower than the animals body temperature. With this in mind, the aim of this study was to characterize behavioral, physiological and morphological profiles and milk production of female Saanen goats belonging to different genetic groups raised in the semi-arid region of Rio Grande do Norte in Northeast Brazil. The study was conducted in the city of Lages (5° 42 00 S and 36° 14 41 W). We used 25 lactating female Saanen goats, distributed into 3 genetic groups: 5 purebred animals, 11 three-quarter bred and 9 half-bred. Behavioral observations were made over three consecutive days in the months of August and September, between 09:00 and 11:30h, when the animals were grazing. Physiological and meteorological data were recorded in the last three days of June, July, August and September at 05:00h and at 16:00h. In the semi-intensive breeding system, the animals from different genetic groups were similar in both field behavior and physiological response patterns. Although the purebred goats had longer hair, they did not show symptoms of thermal discomfort. Their white hair helped to reflect the short wavelength rays and thus eliminate those at the longer wave lengths. We concluded that the animals raised in the semi-intensive milk production system in this study seem to have adapted to the climatic conditions of the semi-arid region of Rio Grande do Norte, Brazil
Resumo:
Jersey cows has been used in warm climates because they have better performance in dairy production. Generally milk production is reduced in warm climates due to the consequent reduction in feed intake because of the heat stress. When the heat stress occurs there is an increase in the body temperature, however it is not known if the skin temperature indicates a thermal discomfort or if it influences milk yield. The objective of this research was to verify if there was a correlation between skin temperature and milk yield using two treatments. Treatment (A) where the cows stayed for 30 minutes before the milking period, in a room with a shower and a fan; and treatment (B) where the cows did not had access to any cooling device (control). After milking the skin temperature were recorded in the places: forehead, back, leg and teats. Data were statistically analyzed and, even though in treatment (A) the skin temperature were reduced it was not found correlation between skin temperature and milk yield.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Geografia - FCT
Resumo:
It is known that the urban environment modifies the energy balance between the surface and the atmosphere, causing changes in temperature, relative humidity, among other things, opening the way for studies aimed at urban climatology. Based on the theme of urban climate, this research focuses on the city of Assis, located west of São Paulo. The generation of urban climate is a result of various factors, among which stand out: the use and different land use, the thermodynamic properties of buildings, number of buildings in the urban, socioeconomic activities, etc.. In general, this increases the temperature and reducing relative humidity, providing thermal discomfort. The rural environment is used for comparison studies to this theme by presenting different characteristics in relation to the structure, morphology and urban functionality. The main objective of this study is to determine the characteristics of temperature and humidity environments with the habits and occupations of the different soils in winter, at night, one inserted into the urban fabric of Assis and the other in the rural environment, to verify for evidence of changes in climatic elements because of urbanization. To collect the data will be used mini automatic weather stations that record data on temperature and humidity. For analysis of the results will be made between the data obtained in the city and the countryside, developing graphics application using Excel to tabulate the data. It was found that there were differences in the thermo-hygrometric data collection points, showing a specific urban climate in the city of Assis
Resumo:
Mirandópolis/SP appeared in 1934 from the railroad “the Brazil Northwest”, that there it served one of the points of its stretch that had as main function to drain the agricultural production northwestern native of São Paulo of that time. The installation of the town happened absent of concerns with initial urbanístico planning, thus modifying its natural landscape and modifying characteristic ambient without compensatory measures aiming at a future expansion of the urban mesh. Fact this that still causes today consequences the quality of life of the people and also the observed thermal comfort later. Ahead of this, the present work had for objective to identify through measurements of temperature and relative humidity of the city of Mirandópolis/SP the differences that in the fabric urban they corroborate for a comfort situation or thermal discomfort to the outdoors in accordance with the Diagram Bioclimático de Olgyay the collection of data was made throughout the month of July of 2011 involving the attainment of information of Temperature and relative humidity of air and questionnaire applied to the passer-bys in the act of the measurements. Also approaching the different thermal dynamic of the zones of housing in relation to the Urban Cannyon that develops the commerce as predominant activity. This research sample that, although a city to be small, the quality of life of its inhabitants is not only guaranteed by the transport or that its thermal comfort reveals inside homogeneous of the urban perimeter, but that it has yes heterogeneidade in the scope of the urban climate in these spaces
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Na avaliação de conforto térmico em ambientes interiores não basta analisar as condições de conforto para o corpo como um todo, pois há a necessidade de se analisar também as condições de desconforto térmico local. Em ambientes complexos, tais como os ambientes cirúrgicos, onde os membros da equipe cirúrgica ocupam diferentes posições no ambiente e desempenham atividades distintas, a análise de condições de desconforto térmico local torna-se ainda mais premente. No presente trabalho foram analisadas condições de desconforto térmico local devido a assimetrias da temperatura radiante, diferença vertical de temperatura do ar e risco de correntes de ar utilizando manequim, medição de variáveis ambientais e avaliação subjetiva. Resultados da avaliação subjetiva mostraram níveis de insatisfação de até 35 % dos anestesistas e enfermeiros com correntes de ar e de até 85% dos cirurgiões com o calor do foco cirúrgico. Resultados similares foram obtidos a partir da medição de variáveis ambientais e com o uso de manequim. Estes resultados ressaltam ainda mais a grande dificuldade de se prover condições de conforto térmico neste tipo de ambiente. Entretanto, a utilização de diferentes ferramentas de análise pode auxiliar na busca de se prover condições de conforto térmico as melhores possíveis para todos os membros da equipe cirúrgica.
Resumo:
La presente investigación parte del problema en las zonas de clima cálido - húmedo en las cuales se producen impactos asociados a la incomodidad térmica producto de la intensa radiación solar, altas temperaturas y elevada humedad. Estos factores reducen la calidad de los espacios abiertos y desarrollan en la población una actitud de rechazo hacia el uso del microespacio urbano entre edificaciones en los desarrollos urbanos - conjuntos urbanos - , los mismos frecuentemente admiten soluciones que al parecer no contribuyen a la realización de las actividades comunes de esparcimiento de la población residente. Por lo tanto, el objetivo de la investigación es profundizar en la temática urbano - ambiental - social y el diseño urbano vinculada a la particularidad morfológica local, las condiciones microclimáticas, el uso del microespacio y los requerimientos de los usuarios. La finalidad de desarrollar estrategias de control microclimático del microespacio entre edificios en clima cálido - húmedo en búsqueda de soluciones óptimas que satisfagan las necesidades de los usuarios de los espacios exteriores en estas áreas residenciales. La investigación se centra en el estudio de las particularidades contextuales relacionadas con el microclima y las características urbanas - morfotipológicas, básicamente los factores microclimáticos (soleamiento y ventilación), los morfológicos y edificatorios y las características de las superficies (pavimentos). En coherencia con el objetivo propuesto el trabajo se desarrolla en cuatro fases: la primera aborda la revisión documental, literatura relevante e investigaciones relativas a la calidad ambiental, medio social, medio físico, el microespacio urbano, control y diseño sostenible, modelización proyectual y estrategias sostenibles; la segunda fase se refiere al marco contextual, características urbanas, datos climáticos locales, planes y procesos urbanos, tipologías y conformación urbana. En esta fase se describe el proceso de selección, análisis y evaluación urbano - ambiental de los casos de estudio (conjuntos residenciales). En la tercera fase se aborda el marco evaluativo y estudio de casos, consideraciones físicas, climáticas y valoración térmico - ambiental de los conjuntos residenciales seleccionados. En esta fase se aplican Técnicas Estadísticas y de Simulación Computacional y se analizan los resultados obtenidos. Finalmente, la cuarta fase propositiva incluye el establecimiento de Estrategias, Principios y Lineamientos de optimación térmica y se exponen las Conclusiones parciales de la tesis, alcances y perspectivas futuras. Finalmente, los resultados obtenidos en la investigación demuestran que el análisis en las experiencias de la realidad permiten comprobar que las situaciones y alteraciones ambientales sustanciales, los niveles de afectación térmica y las condiciones de confortabilidad e impacto derivan de las características urbanas, los componentes del microespacio y de las condiciones climáticas las cuales afectan el desarrollo de las actividades y el uso efectivo del microespacio entre edificios. El análisis de los factores morfo - climáticos incidentes y el estudio de los efectos de interacción contribuyen al establecimiento de Principios y Lineamientos para la evaluación y diseño sostenible del microespacio entre edificios y el uso correcto de los elementos del clima en estas áreas urbanas destinadas a la actividad social y al esparcimiento de la población residente. ABSTRACT This research starts from the problem of hot - humid climate zones where impacts related to thermal discomfort are produced as a result from the intense solar radiation and high temperatures and humidity. These factors reduce the quality of open spaces and people develop an attitude of rejection towards the use of urban microspace among buildings within urban developments - urban complexes - . Usually, these complexes admit solutions that apparently do not contribute to the achievement of common leisure activities in the resident dwellers. Therefore, the main purpose of this research is to deepen in the urban - environmental - social issue and urban design linked to the local morphological particularity, microclimate conditions, use of microspace and users’ requirements. In order to develop microclimate control strategies of microspace among buildings in hot - humid climate to look for optimal solutions that satisfy users’ needs of outdoors spaces in these residential areas. The research focuses in the study of contextual particularities related to microclimate and urban - morphotypological characteristics. Basically, microclimate (sunlight and ventilation), morphological and building factors as well as road surface characteristics. According to the proposed objective, this research is developed in four phases: the first one considers documentary review, relevant literature and researches related to environmental quality, social environment, physical environment, urban microspace, control and sustainable design, project modelling and sustainable strategies; while the second phase refers to contextual framework, urban characteristics, local climate data, plans and urban processes, typologies and urban structure. In this phase, the process of selection, analysis and urban - environmental evaluation of case studies (residential complexes) is described. The third phase approaches the assessment framework and case studies, physical and climate considerations as well as environmental - thermal evaluation of selected residential complexes. In this phase, statistical techniques and computational simulations are applied. Likewise, results obtained are analysed. Similarly, fourth and proposing phase includes the establishment of strategies, principles and guidelines of thermal optimization and partial conclusions of the thesis, scopes and future perspectives are exposed. Finally, from the results obtained, it is demonstrated that the analysis on reality experiences allow proving that situations and substantial environmental changes, levels of thermal affectations, comfort conditions and impact derive from urban characteristics, microspace components and from climate conditions which affect the development of activities and the effective use of microspace among buildings. The analysis of incidental morpho - climate factors and the study of interaction effects contribute to the establishment of principles and guidelines for the assessment and sustainable design of microspace among buildings as well as the correct use of climate elements in these urban areas oriented to social and leisure activities of resident population.