998 resultados para Thermal conditioning


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present study was to investigate the effect of thermal conditioning, (through exposure to heat stress), during pre-hatch development on some physiological responses of post-hatch broilers to a post-natal heat stress challenge. Exposure to heat stress at this stage, we hope, may possibly induce epigenetic heat adaptation. Incubating eggs were exposed to temperature of 39.0degreesC for 2 h from Day 13 to 17 of incubation. At 33, 35, 37, 39, 41 and 43 d of age, the broilers hatched from these eggs were housed individually in open-circuit respiration cells. The climatic chambers were set to 22degreesC and increased to 30degreesC for 4 h. O-2 consumption and CO2 production of each chicken was monitored continuously in order to calculate the heat production. Blood samples were obtained before and during the 4 h heat stress. Thermal conditioning during incubation did not affect the plasma T-4, corticosterone, glucose, uric acid and CK concentrations. Temperature challenge, decreased plasma T-3 of broilers of both groups but the decrease was greater in pre-conditioned broilers compared with controls. A similar trend was observed for triglycerides. These changes did not affect total heat production. Since decreased T3 and triglyceride levels are part of the mechanisms for thermoregulation, these suggest that thermal conditioning during incubation can improve the broiler chicken capability for thermotolerance at later post-hatch age. (C) 2002 Elsevier B.V. Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Previously, we reported that thermal conditioning at 39degreesC on days 13-17 of incubation of broiler eggs enabled thermotolerance during post-hatch growth (J. Therm. Biol. 28 (2003) 133). Tolerance to a temperature of 30degreesC was accompanied by changes in thyroid hormones and metabolic parameters. In the current study, we determined the mechanism of epigenetic heat adaptation during embryonic age by measuring blood physiological parameters that may be associated with the ultimate effects of thermal conditioning. Hatching eggs from Ross breeders were subjected to heat treatment of 39degreesC at days 13, 14, 15, 16 and 17 of incubation for 2 h per day. Control eggs were incubated at 37.6degreesC. Samples of eggs were withdrawn on each day of thermal conditioning and at internal pipping (IP) to obtain blood samples from embryos. The remaining eggs were weighed at day 18 and transferred to hatchers. The timing of IP, external pipping (EP) and hatching were monitored every 2 h. At hatch, chicks were weighed and hatchability was determined. Blood samples were obtained from samples of day-old chicks. T3, T4, corticosterone, pCO(2), pO(2) levels were determined in the blood. Blood pH was measured and T3/T4 ratios were calculated. Heat conditioning significantly increased corticosterone and pO(2) levels and blood pH but depressed pCO(2) at day 14. These were followed by a significant depression of T4 level on day 15. Remarkably, at day 16, all these parameters were back to normal as in the control embryos. Hatching was delayed by thermal conditioning probably as a result of the depressed corticosterone levels at IP. Hatchability was also lower in the heat-treated group but 1-day old chick weights were comparable to those of the controls. The result suggests that epigenetic thermal conditioning involves changes in these physiological parameters and probably serve as a method for epigenetic temperature adaptation since the same mechanisms are employed for coping with heat during post-embryonic growth. It also suggests that days 14-15 may be the optimal and most sensitive timing for evoking this mechanism during embryonic development. The adverse effects of heat treatment observed in this study may have been due to the continued exposure to heat until day 17. Fine-tuning thermal conditioning to days 14-15 only may improve these production parameters. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In tropical climates the heat is one of the major constraints to production of broilers and is responsible for inducing a high mortality, especially in the finishing phase. Thus, the objective of this study was to compare the thermal conditioning early (TC) and feed formulation using dietary electrolytes (DE). Therefore, the electrolyte balance of K+Na-Cl was set at 350 mEq/kg and electrolyte ratio (K+Cl)/Na) in the 3:1 program PPFR (http://www.fmva.unesp.br/ppfr). A total of 300 Cobb 500 1-dold male broiler chicks was randomly allocated to 24 floor pens with six replicates per treatment in a 2x2 factorial arrangement (with and without TC and with and without DE). Dietary treatments consisted: (T1) a traditional diet without TC; (T2) traditional diet with TC; (T3) with the application of dietary electrolyte and without TC and (T4) application of dietary electrolyte with TC. The thermal conditioning was conducted at 5 d of age (36°C for 24 h), only half of the batch (150 birds). After this period, all birds were transferred to boxes of 1.5 x3m (12 birds / box), with wood shavings reused as litter. Chicks were exposed to acute stress (36°C) for 8 h at the age 36, in all treatments, being electronically monitored the temperature and humidity of the microclimate of the birds. Feed and water were provided ad libitum, even during periods of stress. Were measured performance data (weight gain, feed intake and feed conversion) and mortality rate. The early thermal conditioning (T2) and effect of dietary electrolytes (T3) were effective to minimize the mortality of broilers subjected to acute heat stress with a significant difference (P<0.05), without prejudice on broiler performance. The results also showed that there was a more favorable effect when applied dietary electrolytes and thermal conditioning simultaneously (treatment T4). However, for the treatment none of these strategies has been applied (T1), the mortality rate was 83% over that in which they were applied (T4). It was concluded from this study that both techniques: the thermal conditioning early as the dietary electrolytes are efficacious in minimize the damaging effects caused by heat broiler.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

:ofiedian lethal temperatures ( LT50' s ) were determined for rainbow trout, Salmo gairdnerii, acclimated for a minimum of 21 days at 5 c onstant temperatures between 4 and 20 0 C. and 2 diel temperature fluctuations ( sinewave curves of amplitudes ± 4 and ± 7 0 C. about a mean temperature of 12 0 C. ) . Twenty-four-, 48-, and 96-hour LT50 estimates were c alculated f ollowing standard flow-through aquatic bioassay techniques and probi t transformation of mortality data. The phenomenon of delayed thermal mortality was also investigated. Shifts in upper incipient lethal temperature occurred as a result of previous thermal conditioning. It was shown that increases in constant acclimation temperature result in proportional l inear increases in thermal tolerances. The increase i n estimated 96-hour LT50's was approximately 0.13 0 c. X 1 0 C:1 between 8 and 20 0 C. The effect of acclimation to both cyclic temperature regimes was an increase in LT50 to values between the mean and maximum constant equivalent daily temperatures of the cycles. Twenty-four-, 48-, and 96-hour LT50 estimates of both cycles corresponded approximately to the LT50 values of the 16 0 C. c onstant temperature equivalent . This increase i n thermal tolerance was further demonstrated by the delayed thermal mortality experiments . Cycle amplitudes appeared to i nfluence thermal resistance through alterations in initi al mortality since mortality patterns characteristic of base temperature acclimations re-appeared after approximately 68 hours exposure to test temperatures for the 12 + 4 0 C. group, whereas mortality patterns stabilized and remained constant for a period greater than 192 hours with the larger therma l cycle ( 12 + 7 0 C. ). NO s ignificant corre lations between s pecimen weight and time-to-death was apparent. Data are discussed in relation to the establishment of thermal criteria for important commercial and sport fishes , such as the salmonids , as is the question whether previously reported values on lethal temperature s may have been under estimated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O estudo objetivou o estabelecimento de um método efetivo e satisfatório do controle do dano de frio em limas-ácidas. Os frutos colhidos no município de Boa Vista-RR, 140 e 150 dias após a floração, apresentaram valores médios de 7,9 e 8,2 ºBrix; 6,3 e 6,0 mL de ácido cítrico.100mL de polpa-1 e pH de 2,8 e 3,0, respectivamente, nas duas colheitas. Após cada colheita, os frutos foram levados ao laboratório de Fitotecnia/UFRR, onde foram selecionados, limpos e submetidos aos tratamentos: T1 - controle; T2, T3 e T4 - condicionamento a 35ºC, por 6, 12 e 24 horas, respectivamente; T5 - aquecimento intermitente a 20ºC, por 8 horas, após 5 e 10 dias a 1ºC; T6 - aquecimento intermitente a 20ºC, por 8 horas, após 10 e 20 dias a 1ºC; T7 - ethephon a 1.500 mg.L-1; T8 - ethephon a 3.000 mg.L-1. Os tratamentos T9 ao T16, diferenciaram-se dos tratamentos T1 a T8, apenas, na data da colheita (10 dias após a primeira). O experimento foi avaliado a cada 15 dias, durante 75 dias, a 1 ± 0,5 ºC e 92 ± 5 % de UR, quanto ao dano de frio, aspecto visual, perda de massa fresca, sólidos solúveis (SS), acidez titulável (AT), SS/AT (ratio - RT), clorofila total e ácido ascórbico. O atraso na colheita não proporcionou efeito significativo algum. Todos os tratamentos, à exceção do controle e do aquecimento intermitente aos 10 e 20 dias, foram eficientes no controle do dano de frio. No entanto, o tratamento químico e o condicionamento térmico aceleraram precocemente o metabolismo dos frutos, principalmente no que concerne à perda de massa fresca e ao aspecto visual. O maior teor de clorofila total e de ácido ascórbico, bem como o melhor aspecto visual, a não-incidência de podridões e a menor perda de massa fresca foram detectadas nos frutos submetidos ao aquecimento intermitente aos 5 e 10 dias. Os SS, AT e RT estavam dentro dos padrões de qualidade e não variaram estatisticamente entre os tratamentos.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study was conducted with the objective to evaluate the duration of exposure of animals to the evaporative cooling system in the waiting barn on the weather variables (temperature and relative humidity), animal behavior, production and quality aspects of milk from Girolando cows. Sixteen multiparous lactating cows were used having a genetic composition of 7/8 Holstein-Gir and mean milk production of 18 kg animal-1day-1. A 4 × 4 Latin square design was used. The experiment was conducted during the summer season (February-March 2009) and lasted 56 days. The treatments consisted of different periods of 10, 20 and 30 minutes of exposure to acclimatization and control. Time of 30 minutes of exposure to thermal conditioning system enabled the second milking (evening shift), providing an increase in milk production in the next milking of 0.640 kg animal-1. A higher percentage of time spent on food intake and rumination (17.31 and 30.19%) in 30 minutes treatment, compared to control (15.50 and 27.37%), respectively. There was no significant effect of treatments in the composition of milk.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this study was to evaluate the application of early age thermal conditioning (TC) and dietary electrolyte balances (DEB) to minimize the effect of heat stress. A total of 240 Cobb 500 1-d-old male broiler chicks was randomly allocated to 24 floor pens with six replicates per treatment in a 2x2 factorial arrangement (with and without TC and with and without DEB). Dietary treatments consisted: (T1) a traditional diet without TC; (T2) traditional diet with TC; (T3) with the application of dietary electrolyte and without TC and (T4) application of dietary electrolyte with TC. The thermal conditioning was conducted at 5 d of age (36°C for 24 h), only half of the batch (120 birds). After this period, all birds were transferred to boxes of 1.5 x 3m (10 birds / box), with wood shavings reused as litter. Chicks were exposed to chronic heat stress (32°C) for 6 h from 35 to 39 d of age, in all treatments, being electronically monitored the temperature and humidity of the microclimate of the birds. Feed and water were provided ad libitum, even during periods of stress. Were measured performance data (weight gain, feed intake and feed conversion) and mortality rate. Data were subjected to ANOVA using the GLM procedures of SAS. The results of this study demonstrated no interaction effects of all evaluated parameters (performance and mortality). Therefore, no synergism occurred when both strategies (TC and DEB) were applied. Only the first week there was prejudice on broiler performance with the application of the TC and apparently the technique of early age thermal conditioning no improve the resistance of broilers to chronic heat stress. On the other hand, DEB had significantly favorable effects (P<0.05) on performance and minimized mortality immediately after application of the TC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pregnant sows confinement systems were created in order to maximize the productivity, however there are problems concerning the animal welfare. The aim of this research was to evaluate pregnant sows in outdoors and in confinement systems in relation to the thermal environment and physiological animal responses. The experiment was conducted in a commercial farm in Monte Mor city, Sao Paulo, Brazil. The physiological evaluation was performed by recording physiological variables, such as respiratory frequency and skin temperature. Furthermore, variables like dry bulb temperature, wet bulb temperature, and black globe temperature were also evaluated to characterize the ambient by means of enthalpy and black globe humidity index. In each treatment six animals were evaluated. The experimental design was completely randomized in a split-plot version whose averages were compared by the Tukey test. The findings of the experiment revealed higher values for all the bioclimatic variables in the confined treatment. Hence, the outdoor system provided better thermal conditioning for pigs, resulting in a lower heat stress.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Esta tesis doctoral contribuye al análisis y desarrollo de nuevos elementos constructivos que integran sistemas de generación eléctrica a través de células fotovoltaicas (FV); particularmente, basados en tecnología FV de lámina delgada. Para ello se estudia el proceso de la integración arquitectónica de éstos elementos (conocido internacionalmente como “Building Integrated Photovoltaic – BIPV”) mediante diferentes metodologías. Se inicia con el estudio de los elementos fotovoltaicos existentes y continúa con los materiales que conforman actualmente las pieles de los edificios y su posible adaptación a las diferentes tecnologías. Posteriormente, se propone una estrategia de integración de los elementos FV en los materiales constructivos. En ésta se considera la doble función de los elementos BIPV, eléctrica y arquitectónica, y en especial se plantea el estudio de la integración de elementos de disipación térmica y almacenamiento de calor mediante los materiales de cambio de fase (“Phase Change Materials – PCM”), todo esto con el objeto de favorecer el acondicionamiento térmico pasivo a través del elemento BIPV. Para validar dicha estrategia, se desarrolla una metodología experimental que consiste en el diseño y desarrollo de un prototipo denominado elemento BIPV/TF – PCM, así como un método de medida y caracterización en condiciones de laboratorio. Entre los logros alcanzados, destaca la multifuncionalidad de los elementos BIPV, el aprovechamiento de la energía residual del elemento, la reducción de los excedentes térmicos que puedan modificar el balance térmico de la envolvente del edificio, y las mejoras conseguidas en la producción eléctrica de los módulos fotovoltaicos por reducción de temperatura, lo que hará más sostenible la solución BIPV. Finalmente, como resultado del análisis teórico y experimental, esta tesis contribuye significativamente al estudio práctico de la adaptabilidad de los elementos BIPV en el entorno urbano por medio de una metodología que se basa en el desarrollo y puesta en marcha de una herramienta informática, que sirve tanto a ingenieros como arquitectos para verificar la calidad de la integración arquitectónica y calidad eléctrica de los elementos FV, antes, durante y después de la ejecución de un proyecto constructivo. ABSTRACT This Doctoral Thesis contributes to the analysis and development of new building elements that integrate power generation systems using photovoltaic solar cells (PV), particularly based on thin-film PV technology. For this propose, the architectural integration process is studied (concept known as "Building Integrated Photovoltaic - BIPV") by means of different methodologies. It begins with the study of existing PV elements and materials that are currently part of the building skins and the possible adaptation to different technologies. Subsequently, an integration strategy of PV elements in building materials is proposed. Double function of BIPV elements is considered, electrical and architectural, especially the heat dissipation and heat storage elements are studied, particularly the use Phase Change Materials– PCM in order to favor the thermal conditioning of buildings by means of the BIPV elements. For this propose, an experimental methodology is implemented, which consist of the design and develop of a prototype "BIPV/TF- PCM element" and measurement method (indoor laboratory conditions) in order to validate this strategy. Among the most important achievements obtained of this develop and results analysis includes, in particular, the multifunctionality of BIPV elements, the efficient use of the residual energy of the element, reduction of the excess heat that it can change the heat balance of the building envelope and improvements in electricity production of PV modules by reducing the temperature, are some benefits achieved that make the BIPV element will be more sustainable. Finally, as a result of theoretical and experimental analysis, this thesis contributes significantly to the practical study of the adaptability of BIPV elements in the urban environment by means of a novel methodology based on the development and implementation by computer software of a useful tool which serves as both engineers and architects to verify the quality of architectural integration and electrical performance of PV elements before, during, and after execution of a building projects.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Se propone una metodología para la evaluación de soluciones constructivas de fachada para la rehabilitación de viviendas sociales, construidas entre el final de la Guerra Civil y la entrada en vigor de la norma básica NBE-CT-79, sobre condiciones térmicas en edificios. La metodología parte por un lado del análisis del estado actual en las viviendas, y por otro de la caracterización de las soluciones constructivas de rehabilitación, para la evaluación conjunta de las posibles mejoras. Esta evaluación persigue valorar su repercusión en la calidad del ambiente interior, y en la reducción de la demanda energética para acondicionamiento térmico. Se aplica sobre dos viviendas tipo que se han monitorizado en Madrid, utilizando dos soluciones innovadoras para rehabilitación energética, que disponen de documentos de idoneidad DIT y DITE. Una incorpora sobre la fachada tipo un aislamiento por el exterior, y otra incorpora un sistema de fachada ventilada, también sobre esta fachada tipo. El análisis de las viviendas se ha realizado a partir de la toma de datos, ensayos y estudio de detalle, llevados a cabo a lo largo de los años 2014 y 2015. El análisis de los sistemas de fachada se ha realizado a partir de ensayos controlados, comparando los resultados para tres tipos de fachada: una fachada tipo, habitual en la construcción de las viviendas de este periodo, y las dos soluciones innovadoras mencionadas. Una vez realizado el diagnóstico de las viviendas y el análisis de los ensayos de los sistemas constructivos, los resultados obtenidos se utilizan para generar los modelos de simulación sobre los que evaluar las mejoras. El periodo de estudio comprende cuatro décadas que comienzan en 1940, en un momento con escasos medios técnicos para la construcción, y que coincide con el comienzo del crecimiento en las grandes ciudades, y finaliza con la incorporación en la normativa de las exigencias de aislamiento en fachadas, de 1979. En la ciudad de Madrid las viviendas construidas en este periodo, suponen un 45% del total de viviendas censadas en 2011. La rehabilitación energética se ha ido incorporando en los sucesivos planes nacionales de vivienda como actuación protegida, y son muchos y muy diversos los planes de acción desde la administración en materia de vivienda social, tanto a nivel nacional como europeo. La vivienda queda incluida en materia de desarrollo y cohesión urbana, territorial y social, haciendo necesario un enfoque integrado. Los barrios de vivienda social forman parte de un patrimonio construido en los que los criterios de sostenibilidad toman especial interés y relevancia, ya que a través del tiempo se han construido como actores y testigos de su historia social, económica, ambiental y cultural. El diseño de los modelos y actuaciones de futuro se sustenta en la asimilación de esa complejidad y diversidad adquirida. Por otro lado, el actual reto que impone el calentamiento global obliga a plantear escenarios de adaptación y mejora en estos edificios, con una especial atención a la dependencia energética, el consumo de recursos, y emisiones de gases de efecto invernadero. La fachada es el elemento más importante de la envolvente en los edificios multifamiliares, siendo el lugar donde se produce el intercambio entre el ambiente interior y exterior. Su rehabilitación puede mejorar las prestaciones de habitabilidad en las viviendas, y disminuir la demanda de energía para alcanzar unas condiciones de confort estándar. El trabajo de investigación que se ha realizado, forma parte de una linea de investigación abierta sobre sistemas constructivos y habitabilidad en edificación. ABSTRACT A methodology for the evaluation of facade’s constructive solutions for social housing refurbishment, built between the end of the Civil War, and the entry into force of the basic standard NBE-CT-79 on thermal conditions in buildings is proposed. This methodology starts both with the analysis of the current status in dwellings, and with the characterization of rehabilitation’s constructive solutions performance, for the integrated assessment of improvements. The evaluation seeks to assess their impact on the indoor environmental quality, and on reducing the energy demand for thermal conditioning. The methodology is applied to two standard dwellings, that have been monitored in Madrid, with two innovative solutions for energy refurbishment, which have DIT and DITE assessment documents. One incorporates an exterior insulation, and the other incorporates a ventilated facade system. The analysis of the dwellings was made from data collection, testing and detailed study, conducted throughout 2014 and 2015. Analysis of the facade systems was made from controlled trials comparing the results for three types of façade: a standard usual facade common in the construction of this period, and the two innovative solutions mentioned. Based on the diagnosis of housing and systems analysis, the results are used to generate simulation models on which assess the improvements. The study period comprises four decades starting in 1940, at a time with limited technical resources for construction, which coincides with the beginning of growth in big cities, and ends with the incorporation in the 1979 legislation of the façade’s insulation requirements. In the city of Madrid the houses built in this period account for 45% of all households surveyed in 2011. As a “protected action” energy rehabilitation has been incorporated in successive national housing plans, and there are many and very different action plans from the Administration in the field of social housing, both at national and European level. An integrated approach is needed, due to the inclusion of housing in development and urban, territorial and social cohesion. Social housing neighborhoods are part of the built heritage. Sustainability criteria therefore are particularely relevant, since over time they have been built as actors and witnesses of their social, economic, environmental and cultural history. The design and performance of future models is based on the assimilation of this complexity and diversity acquired. On the other hand, the current challenge posed by global warming forces to consider scenarios for adaptation and improvement in these buildings, with particular attention to energy dependence, resource consumption, and greenhouse gas emissions. The facade is the most important element of the envelope in the multi-family buildings, being the place where the exchange occurs between the indoor and outdoor environments. Its rehabilitation can improve wellbeing in housing performance, and reduce energy demand to achieve standard comfort conditions. This research that has been done, is part of an open research line on construction and living conditions in buildings.