943 resultados para Testing Facilities


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two force balance techniques for use in hypersonic impulse facilities are compared by measuring the drag force on a 30° semi-apex-angle blunt cone model in a hypersonic shock tunnel at a free stream Mach number of 5.75. An accelerometer-based balance and a stress-wave force balance were tested simultaneously on the same model to measure the drag force. It was found that drag force measurements could be made using both techniques in a flow with a 450-μ s test period. The measured drag forces compared well with the theoretical values estimated using Newtonian theory.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

As identified by Griffin (1997) and Kahn (2012), manufacturing organisations typically improve their market position by accelerating their product development (PD) cycles. One method for achieving this is to reduce the time taken to design, test and validate new products, so that they can reach the end customer before competition. This paper adds to existing research on PD testing procedures by reporting on an exploratory investigation carried out in a UK-based manufacturing plant. We explore the organisational and managerial factors that contribute to the time spent on testing of new products during development. The investigation consisted of three sections, viz. observations and process modelling, utilisation metrics and a questionnaire-based investigation, from which a proposed framework to improve and reduce the PD time cycle is presented. This research focuses specifically on the improvement of the utilisation of product testing facilities and the links to its main internal stakeholders - PD engineers.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Prostate cancer is a major cause of cancer death in Nigerian men. Attempts to reduce mortality from prostate cancer have focused mainly on early detection of the disease by the use of PSA testing. As a result of the increased incidence of prostate cancer in Nigeria despite the widespread availability of testing facilities, it became pertinent to understand the salient factors that prompt Nigerian men to go for prostate cancer testing. Objective: This study explores the factors that influence a group of Nigerian men’s decision to go for Prostate Specific Antigen (PSA) testing. Methods: Following ethical approval, semi structured interviews were conducted with a group of 10 men who had PSA test following consultation with their doctor with signs and symptoms at the University of Benin Teaching Hospital from July to August, 2010. Interview transcripts were analysed by employing steps proposed by Collaizi (1978). Results: Five themes were identified: the symptoms experienced, the influence of friends and relatives, older age associated with increased awareness, accessibility to testing services and the knowledge of the PSA test. Conclusion: The study revealed that there continues to be a considerable lack of awareness and knowledge about prostate cancer and screening.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Diplomityö on tehty Insinööritoimisto W.Zenner Oy:n LVI -tekniikan laboratoriossa. Insinööritoimisto W.Zenner Oy:n LVI-tekniikan laboratorio tarjoaa alan yrityksille tutkimuspalveluita sekä laboratoriossa että kentällä. Tämän työn tarkoituksena on ollut määrittää asiakkaan keksimän, toimintaperiaatteltaan aiemmista poikkeavan, lumenerotusjärjestelmän prototyypin lumenerotusaste. Mittausten aikana kuitenkin ilmeni, että keksintö ei sellaisenaan ole toimiva. Tämän vuoksi on työssä käsitelty hieman laajemmin lumenerottelutapoja, järjestelmien suunnittelu- ja käyttöperusteita sekä niiden testausmahdollisuuksia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Early diagnosis and appropriate therapy are essential for the best prognosis and quality of life in patients with primary immunodeficiency diseases (PIDDs). Experts from several Latin American countries have been meeting on a regular basis as part of an ongoing effort to improve the diagnosis and treatment of PIDD in this region. Three programmes are in development that will expand education and training and improve access to testing facilities throughout Latin America. These programmes are: an educational outreach programme (The L-Project); an immunology fellowship programme; and the establishment of a laboratory network to expand access to testing facilities. This report provides the status of these programmes based on the most recent discussions and describes the next steps toward full implementation of these programmes. (C) 2010 SEICAP. Published by Elsevier Espana, S.L. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hurricane is one of the most destructive and costly natural hazard to the built environment and its impact on low-rise buildings, particularity, is beyond acceptable. The major objective of this research was to perform a parametric evaluation of internal pressure (IP) for wind-resistant design of low-rise buildings and wind-driven natural ventilation applications. For this purpose, a multi-scale experimental, i.e. full-scale at Wall of Wind (WoW) and small-scale at Boundary Layer Wind Tunnel (BLWT), and a Computational Fluid Dynamics (CFD) approach was adopted. This provided new capability to assess wind pressures realistically on internal volumes ranging from small spaces formed between roof tiles and its deck to attic to room partitions. Effects of sudden breaching, existing dominant openings on building envelopes as well as compartmentalization of building interior on the IP were systematically investigated. Results of this research indicated: (i) for sudden breaching of dominant openings, the transient overshooting response was lower than the subsequent steady state peak IP and internal volume correction for low-wind-speed testing facilities was necessary. For example a building without volume correction experienced a response four times faster and exhibited 30–40% lower mean and peak IP; (ii) for existing openings, vent openings uniformly distributed along the roof alleviated, whereas one sided openings aggravated the IP; (iii) larger dominant openings exhibited a higher IP on the building envelope, and an off-center opening on the wall exhibited (30–40%) higher IP than center located openings; (iv) compartmentalization amplified the intensity of IP and; (v) significant underneath pressure was measured for field tiles, warranting its consideration during net pressure evaluations. The study aimed at wind driven natural ventilation indicated: (i) the IP due to cross ventilation was 1.5 to 2.5 times higher for Ainlet/Aoutlet>1 compared to cases where Ainlet/Aoutlet<1, this in effect reduced the mixing of air inside the building and hence the ventilation effectiveness; (ii) the presence of multi-room partitioning increased the pressure differential and consequently the air exchange rate. Overall good agreement was found between the observed large-scale, small-scale and CFD based IP responses. Comparisons with ASCE 7-10 consistently demonstrated that the code underestimated peak positive and suction IP.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Marine Renewable Energy Conversion systems comprise wave energy and tidal stream converters as well as offshore-wind turbines for electrical generation. These technologies are currently at different stages of development but are mostly at the pre-commercial stage and require research to be undertaken at a series of scales along the path to commercialization. However each of these technologies also needs specific research infrastructures in order to conduct this research. The aim of the MARINET initiative is to coordinate research and development at all scales (small models through to prototype scales, from laboratories through to open sea tests) and to allow access for researchers and developers to infrastructures which are not available universally in Europe, including test facilities for components such as power take-off systems, grid integration, moorings and environmental monitoring so as to ensure a focusing of activities in this area. The initiative offers researchers and developers access to 45 research facilities as well as to the associated network of expertise at all scales in Offshore Marine Renewable Energy technology research and development. The aim of this paper is to present this MARINET initiative that was started in 2011, bringing together a network of 29 partners spread across twelve countries. Details of the MARINET Transnational Access (TA) program are presented, for which over 260 applications were received throughout the 5 official calls for proposals. In particular, statistics on applications and completed projects are presented which provide an overview of the global development progress of the different offshore renewable energy conversion technologies at a European level. It also provides a good overview of the current research activity, as well as evidence of the requirement for specialised research facilities, in this burgeoning field.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Syphilis remains a significant cause of preventable perinatal death in developing countries with many women remaining untested and thus untreated. Syphilis testing in the clinic (on-site testing) may be a useful strategy to overcome this. We studied the impact of on-site syphilis testing on treatment delays and rates, and perinatal mortality. Methods: We conducted a cluster randomised controlled trial among seven pairs of primary healthcare clinics in rural South Africa, comparing on-site testing complemented by laboratory confirmation versus laboratory testing alone. Intervention clinics used the on-site test conducted by primary care nurses, with results and treatment available within an hour. Control clinics sent blood samples to the provincial laboratory, with results returned 2 weeks later. Results: Of 7134 women seeking antenatal care with available test results, 793 (11.1%) tested positive for syphilis. Women at intervention clinics completed treatment 16 days sooner on average (95% confidence interval: 11 to 21), though there was no significant difference in the proportion receiving adequate treatment at intervention (64%) and control (69%) clinics. There was also no significant difference in the proportion experiencing perinatal loss (3.3% v 5.1%; adjusted risk difference: -0.9%; 95% Cl -4.4 to 2.7). Conclusions: Despite reducing treatment delays, the addition of on-site syphilis testing to existing laboratory testing services did not lead to higher treatment rates or reduce perinatal mortality. However on-site testing for syphilis may remain an important option for improving antenatal care in settings where laboratory facilities are not available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wastewater control at storage terminals of liquid chemical products in bulk is very difficult because of the variety of products handled in the facilities generating effluents of variable composition. The main objective of this work was to verify if the Vibrio fischeri acute toxicity test could be routinely included in the wastewater management of those facilities along with physical and chemical analysis in order to evaluate and improve the quality of the generated effluents. The study was performed in two phases before and after the implementation of better operational practices/treatment technologies. Chemical oxygen demand (COD) and toxicity of treated effluents did not correlate showing that effluents with low COD contain toxic substances and non-biodegradable organic matter, which may be not degraded when discharged into the aquatic environment. Segregation of influents or pre-treatment based on toxicity results and biodegradability index were implemented in the facilities generating significant improvements in the quality of final effluents with reduction of Biochemical oxygen demand (BOD) and toxicity. The integration of physical and chemical analysis with the V.fischeri toxicity test turned out to be an excellent tool for wastewater management in chemical terminals allowing rapid decision making for pollution control and prevention measures. Reuse of rain water was also proposed and when implemented by the facilities resulted in economical and environmental benefits. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The application of DNA-based markers toward the task of discriminating among alternate salmon runs has evolved in accordance with ongoing genomic developments and increasingly has enabled resolution of which genetic markers associate with important life-history differences. Accurate and efficient identification of the most likely origin for salmon encountered during ocean fisheries, or at salvage from fresh water diversion and monitoring facilities, has far-reaching consequences for improving measures for management, restoration and conservation. Near-real-time provision of high-resolution identity information enables prompt response to changes in encounter rates. We thus continue to develop new tools to provide the greatest statistical power for run identification. As a proof of concept for genetic identification improvements, we conducted simulation and blind tests for 623 known-origin Chinook salmon (Oncorhynchus tshawytscha) to compare and contrast the accuracy of different population sampling baselines and microsatellite loci panels. This test included 35 microsatellite loci (1266 alleles), some known to be associated with specific coding regions of functional significance, such as the circadian rhythm cryptochrome genes, and others not known to be associated with any functional importance. The identification of fall run with unprecedented accuracy was demonstrated. Overall, the top performing panel and baseline (HMSC21) were predicted to have a success rate of 98%, but the blind-test success rate was 84%. Findings for bias or non-bias are discussed to target primary areas for further research and resolution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Guided by a modified information-motivation-behavioral skills model, this study identified predictors of condom use among heterosexual people living with HIV with their steady partners. Consecutive patients at 14 European HIV outpatient clinics received an anonymous, standardized, self-administered questionnaire between March and December 2007. Data were analyzed using descriptive statistics and two-step backward elimination regression analyses stratified by gender. The survey included 651 participants (n = 364, 56% women; n = 287, 44%). Mean age was 39 years for women and 43 years for men. Most had acquired HIV sexually and more than half were in a serodiscordant relationship. Sixty-three percent (n = 229) of women and 59% of men (n = 169) reported at least one sexual encounter with a steady partner 6 months prior to the survey. Fifty-one percent (n = 116) of women and 59% of men (n = 99) used condoms consistently with that partner. In both genders, condom use was positively associated with subjective norm conducive to condom use, and self-efficacy to use condoms. Having a partner whose HIV status was positive or unknown reduced condom use. In men, higher education and knowledge about condom use additionally increased condom use, while the use of erectile-enhancing medication decreased it. For women, HIV disclosure to partners additionally reduced the likelihood of condom use. Positive attitudes to condom use and subjective norm increased self-efficacy in both genders, however, a number of gender-related differences appeared to influence self-efficacy. Service providers should pay attention to the identified predictors of condom use and adopt comprehensive and gender-related approaches for preventive interventions with people living with HIV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Jatkuvasti lisääntyvä matkapuhelinten käyttäjien määrä, internetin kehittyminen yleiseksi tiedon ja viihteen lähteeksi on luonut tarpeen palvelulle liikkuvan työaseman liittämiseksi tietokoneverkkoihin. GPRS on uusi teknologia, joka tarjoaa olemassa olevia matka- puhelinverkkoja (esim. NMT ja GSM) nopeamman, tehokkaamman ja taloudellisemman liitynnän pakettidataverkkoihin, kuten internettiin ja intranetteihin. Tämän työn tavoitteena oli toteuttaa GPRS:n paketinohjausyksikön (Packet Control Unit, PCU) testauksessa tarvittavat viestintäajurit työasemaympristöön. Aidot matkapuhelinverkot ovat liian kalliita, eikä niistä saa tarvittavasti lokitulostuksia, jotta niitä voisi käyttää GPRS:n testauksessa ohjelmiston kehityksen alkuvaihessa. Tämän takia PCU-ohjelmiston testaus suoritetaan joustavammassa ja helpommin hallittavassa ympäristössä, joka ei aseta kovia reaaliaikavaatimuksia. Uusi toimintaympäristö ja yhteysmedia vaativat PCU:n ja muiden GPRS-verkon yksiköiden välisistä yhteyksistä huolehtivien ohjelman osien, viestintäajurien uuden toteutuksen. Tämän työn tuloksena syntyivät tarvittavien viestintäajurien työasemaversiot. Työssä tarkastellaan eri tiedonsiirtotapoja ja -protokollia testattavan ohjelmiston vaateiden, toteutetun ajurin ja testauksen kannalta. Työssä esitellään kunkin ajurin toteuttama rajapinta ja toteutuksen aste, eli mitkä toiminnot on toteutettu ja mitä on jätetty pois. Ajureiden rakenne ja toiminta selvitetään siltä osin, kuin se on oleellista ohjelman toiminnan kannalta.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A retrospective study of patients hospitalized with influenza and/or pneumonia in a Niagara area community hospital for the influenza season 2003-04 was designed with the main goal of enhancing pneumonia surveillance in acute care facilities and the following specific objectives: 1) identify etiologies, factors, and clinical presentation associated with pneumonia; 2) assess the ODIN score on ICU patients to predict outcomes of severe pneumonia; 3) identify the frequency of pneumonia and influenza in a hospital setting; and 4) develop a hospital pneumonia electronic surveillance tool. A total of 172 patients' charts (50% females) were reviewed and classified into two groups: those with diagnosis of pneumonia (n=132) and those without pneumonia (n=40). The latter group consisted mainly of patients with influenza (85%). Most patients were young (<10yrs) or elderly (>71yrs). Presenting body temperature <38°C, cough symptoms, respiratory and cardiac precomorbidities were common in both groups. Pneumonia was more frequent in males (p= .032) and more likely community-acquired (98%) than nosocomial (2%). No evidence of ventilator-associated pneumonia was found. Microbiology testing in 72% of cases detected 19 different pathogens. In pneumonia patients the most common organisms were Streptococcus pneumoniae (3%), Respiratory syncytial virus (4%), and Influenza A virus (2%). Conversely, Influenza A virus was identified in 73% of non-pneumonia patients. Community-acquired influenza was more common (80%) than nosocomial influenza (20%). The ODIN score was a good predictor of mortality and the new electronic surveillance tool was an effective prototype to monitor patients in acute care, especially during influenza season. The results of this study provided baseline data on respiratory illness surveillance and demonstrated that future research, including prospective studies, is warranted in acute care facilities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. There is emerging evidence that context is important for successful transfer of research knowledge into health care practice. The Alberta Context Tool (ACT) is a Canadian developed research-based instrument that assesses 10 modifiable concepts of organizational context considered important for health care professionals’ use of evidence. Swedish and Canadian health care have similarities in terms of organisational and professional aspects, suggesting that the ACT could be used for measuring context in Sweden. This paper reports on the translation of the ACT to Swedish and a testing of preliminary aspects of its validity, acceptability and reliability in Swedish elder care. Methods. The ACT was translated into Swedish and back-translated into English before being pilot tested in ten elder care facilities for response processes validity, acceptability and reliability (Cronbach’s alpha). Subsequently, further modification was performed. Results. In the pilot test, the nurses found the questions easy to respond to (52%) and relevant (65%), yet the questions’ clarity were mainly considered ‘neither clear nor unclear’ (52%). Missing data varied between 0 (0%) and 19 (12%) per item, the most common being 1 missing case per item (15 items). Internal consistency (Cronbach’s Alpha > .70) was reached for 5 out of 8 contextual concepts. Translation and back translation identified 21 linguistic- and semantic related issues and 3 context related deviations, resolved by developers and translators. Conclusion. Modifying an instrument is a detailed process, requiring time and consideration of the linguistic and semantic aspects of the instrument, and understanding of the context where the instrument was developed and where it is to be applied. A team, including the instrument’s developers, translators, and researchers is necessary to ensure a valid translation. This study suggests preliminary validity, reliability and acceptability evidence for the ACT when used with nurses in Swedish elder care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Regarding the location of a facility, the presumption in the widely used p-median model is that the customer opts for the shortest route to the nearest facility. However, this assumption is problematic on free markets since the customer is presumed to gravitate to a facility by the distance to and the attractiveness of it. The recently introduced gravity p-median model offers an extension to the p-median model that account for this. The model is therefore potentially interesting, although it has not yet been implemented and tested empirically. In this paper, we have implemented the model in an empirical problem of locating vehicle inspections, locksmiths, and retail stores of vehicle spare-parts for the purpose of investigating its superiority to the p-median model. We found, however, the gravity p-median model to be of limited use for the problem of locating facilities as it either gives solutions similar to the p-median model, or it gives unstable solutions due to a non-concave objective function.