1000 resultados para Teste de produção


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This document aims to improve the quality of the production test in vertical tanks with free water drain pipes, through a device to control the draining system. This proposal consists of an interface detector close to the tank bottle and a control valve on the pipe-drain; they are attached to a remote supervisor system, which will be minimizing the human influence in the conclusion of the test result. And for more consciousness the work shows the importance of the wells production test in the attendance and diagnosis of the productive process, informing the large number of tests executed and problems of the procedure adopted in the field today. There are many possible sources of uncertainty in this kind of test as shown in the experiments realized in the field; the object prototype of this dissertation will be made in the field, based upon the definition of parameters and characteristics of the devices proposal. For a better definition of the draining process the action results of the assessment test are shown, especially changed some for the understand ing of the real process. It shows the proposal details and the configuration that will be used in the tank of Monte Alegre s field Production Station, explaining the interface detector kind and the control system. It is the base to a pilot project now in development, named as the new project classified in the status of the new technology and production improvement of PETROBRAS in Rio Grande do Norte and Ceará. This dissertation concludes that the automation of the conventional test with the draining system will bring benefits both economically as metrologically, because it reduces the uncertainty of the test procedures with free water draining, and also decreases the number of tests with problems

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This document aims to improve the quality of the production test in vertical tanks with free water drain pipes, through a device to control the draining system. This proposal consists of an interface detector close to the tank bottle and a control valve on the pipe-drain; they are attached to a remote supervisor system, which will be minimizing the human influence in the conclusion of the test result. And for more consciousness the work shows the importance of the wells production test in the attendance and diagnosis of the productive process, informing the large number of tests executed and problems of the procedure adopted in the field today. There are many possible sources of uncertainty in this kind of test as shown in the experiments realized in the field; the object prototype of this dissertation will be made in the field, based upon the definition of parameters and characteristics of the devices proposal. For a better definition of the draining process the action results of the assessment test are shown, especially changed some for the understand ing of the real process. It shows the proposal details and the configuration that will be used in the tank of Monte Alegre s field Production Station, explaining the interface detector kind and the control system. It is the base to a pilot project now in development, named as the new project classified in the status of the new technology and production improvement of PETROBRAS in Rio Grande do Norte and Ceará. This dissertation concludes that the automation of the conventional test with the draining system will bring benefits both economically as metrologically, because it reduces the uncertainty of the test procedures with free water draining, and also decreases the number of tests with problems

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Dissertação de mestrado em Português Língua Não Materna (PLNM): Português Língua Estrangeira (PLE) Português Língua Segunda (PL2)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This work intends to analyze the behavior of the gas flow of plunger lift wells producing to well testing separators in offshore production platforms to aim a technical procedure to estimate the gas flow during the slug production period. The motivation for this work appeared from the expectation of some wells equipped with plunger lift method by PETROBRAS in Ubarana sea field located at Rio Grande do Norte State coast where the produced fluids measurement is made in well testing separators at the platform. The oil artificial lift method called plunger lift is used when the available energy of the reservoir is not high enough to overcome all the necessary load losses to lift the oil from the bottom of the well to the surface continuously. This method consists, basically, in one free piston acting as a mechanical interface between the formation gas and the produced liquids, greatly increasing the well s lifting efficiency. A pneumatic control valve is mounted at the flow line to control the cycles. When this valve opens, the plunger starts to move from the bottom to the surface of the well lifting all the oil and gas that are above it until to reach the well test separator where the fluids are measured. The well test separator is used to measure all the volumes produced by the well during a certain period of time called production test. In most cases, the separators are designed to measure stabilized flow, in other words, reasonably constant flow by the use of level and pressure electronic controllers (PLC) and by assumption of a steady pressure inside the separator. With plunger lift wells the liquid and gas flow at the surface are cyclical and unstable what causes the appearance of slugs inside the separator, mainly in the gas phase, because introduce significant errors in the measurement system (e.g.: overrange error). The flow gas analysis proposed in this work is based on two mathematical models used together: i) a plunger lift well model proposed by Baruzzi [1] with later modifications made by Bolonhini [2] to built a plunger lift simulator; ii) a two-phase separator model (gas + liquid) based from a three-phase separator model (gas + oil + water) proposed by Nunes [3]. Based on the models above and with field data collected from the well test separator of PUB-02 platform (Ubarana sea field) it was possible to demonstrate that the output gas flow of the separator can be estimate, with a reasonable precision, from the control signal of the Pressure Control Valve (PCV). Several models of the System Identification Toolbox from MATLAB® were analyzed to evaluate which one better fit to the data collected from the field. For validation of the models, it was used the AIC criterion, as well as a variant of the cross validation criterion. The ARX model performance was the best one to fit to the data and, this way, we decided to evaluate a recursive algorithm (RARX) also with real time data. The results were quite promising that indicating the viability to estimate the output gas flow rate from a plunger lift well producing to a well test separator, with the built-in information of the control signal to the PCV

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Electronic applications are currently developed under the reuse-based paradigm. This design methodology presents several advantages for the reduction of the design complexity, but brings new challenges for the test of the final circuit. The access to embedded cores, the integration of several test methods, and the optimization of the several cost factors are just a few of the several problems that need to be tackled during test planning. Within this context, this thesis proposes two test planning approaches that aim at reducing the test costs of a core-based system by means of hardware reuse and integration of the test planning into the design flow. The first approach considers systems whose cores are connected directly or through a functional bus. The test planning method consists of a comprehensive model that includes the definition of a multi-mode access mechanism inside the chip and a search algorithm for the exploration of the design space. The access mechanism model considers the reuse of functional connections as well as partial test buses, cores transparency, and other bypass modes. The test schedule is defined in conjunction with the access mechanism so that good trade-offs among the costs of pins, area, and test time can be sought. Furthermore, system power constraints are also considered. This expansion of concerns makes it possible an efficient, yet fine-grained search, in the huge design space of a reuse-based environment. Experimental results clearly show the variety of trade-offs that can be explored using the proposed model, and its effectiveness on optimizing the system test plan. Networks-on-chip are likely to become the main communication platform of systemson- chip. Thus, the second approach presented in this work proposes the reuse of the on-chip network for the test of the cores embedded into the systems that use this communication platform. A power-aware test scheduling algorithm aiming at exploiting the network characteristics to minimize the system test time is presented. The reuse strategy is evaluated considering a number of system configurations, such as different positions of the cores in the network, power consumption constraints and number of interfaces with the tester. Experimental results show that the parallelization capability of the network can be exploited to reduce the system test time, whereas area and pin overhead are strongly minimized. In this manuscript, the main problems of the test of core-based systems are firstly identified and the current solutions are discussed. The problems being tackled by this thesis are then listed and the test planning approaches are detailed. Both test planning techniques are validated for the recently released ITC’02 SoC Test Benchmarks, and further compared to other test planning methods of the literature. This comparison confirms the efficiency of the proposed methods.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work shows a project method proposed to design and build software components from the software functional m del up to assembly code level in a rigorous fashion. This method is based on the B method, which was developed with support and interest of British Petroleum (BP). One goal of this methodology is to contribute to solve an important problem, known as The Verifying Compiler. Besides, this work describes a formal model of Z80 microcontroller and a real system of petroleum area. To achieve this goal, the formal model of Z80 was developed and documented, as it is one key component for the verification upto the assembly level. In order to improve the mentioned methodology, it was applied on a petroleum production test system, which is presented in this work. Part of this technique is performed manually. However, almost of these activities can be automated by a specific compiler. To build such compiler, the formal modelling of microcontroller and modelling of production test system should provide relevant knowledge and experiences to the design of a new compiler. In ummary, this work should improve the viability of one of the most stringent criteria for formal verification: speeding up the verification process, reducing design time and increasing the quality and reliability of the product of the final software. All these qualities are very important for systems that involve serious risks or in need of a high confidence, which is very common in the petroleum industry

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Alimentos e Nutrição - FCFAR

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Atualmente, a produtividade do feijoeiro comum (Phaseolus vulgaris L.) pode ser reduzida devido à ocorrência de doenças em todo o território nacional, destacando-se a murcha de fusário, causada por Fusarium oxysporum f. sp. phaseoli (Fop). No campo, o patógeno é disseminado a longas distâncias através das sementes infectadas e/ou contaminadas e a sua sobrevivência ocorre, principalmente, no solo. Os objetivos deste trabalho foram: avaliar a inibição do crescimento micelial de Fop por Trichoderma spp.; classificar a sensibilidade in vitro de Fop e Trichoderma spp., separadamente, a fungicidas e verificar a compatibilidade entre fungicidas químicos e biológicos para controle de Fop, presente nas sementes e no solo. Para avaliar a inibição do crescimento micelial de Fop, foram utilizados três isolados do patógeno, os quais foram confrontados, in vitro, com três isolados de Trichoderma spp. em testes de cultura pareada e produção de metabólitos voláteis a 20-22°C. Os experimentos foram conduzidos em delineamento inteiramente casualizado, com cinco repetições para cada isolado de Trichoderma. Para a classificação da sensibilidade in vitro de Fop e Trichoderma a fungicidas, foram avaliados os mesmos isolados anteriormente utilizados. Foram comparados dez fungicidas, em doses entre 0 a 100 mg L-1 que foram ajustadas de acordo com a CI50 de cada fungicida. Com base na percentagem de inibição do crescimento micelial, foram estimados os valores da concentração inibitória de 50% (CI50) e 100% (CI100) e selecionaram-se os fungicidas compatíveis com Trichoderma spp. A compatibilidade entre tratamentos químico e biológico foi avaliada através da inoculação artificial de sementes de feijão com um isolado de Fop (IAC 11.299-1) e infestação do mesmo no solo. As sementes foram tratadas com os fungicidas fludioxonil, flutriafol e tiofanato metílico, e com os três produtos biológicos, separadamente e em misturas. Avaliou-se o efeito dos tratamentos por meio dos testes de sanidade, germinação, comprimento de plântulas, massa da matéria seca em laboratório e índice de velocidade de emergência e porcentagem de emergência em estufa não climatizada. O efeito protetor dos tratamentos foi verificado através do teste de transmissão do patógeno solo-planta. Todos os isolados de Trichoderma apresentaram antagonismo in vitro contra Fop. No teste de cultura pareada foi observada uma redução de 15 a 20% no crescimento micelial do patógeno. No teste de produção de metabólitos voláteis, o isolado T12-1086G05 foi responsável pela maior inibição do crescimento micelial de Fop (10 a 48%). Os testes de sensibilidade in vitro mostraram que tiofanato metílico, flutriafol e fludioxonil foram compatíveis com Trichoderma (CI50 > 2 mg L-1). Com exceção do flutriafol e do GF 422 isolados e em mistura, todos os tratamentos foram eficientes na erradicação de Fop nas sementes, sem afetar a sua qualidade fisiológica. No teste de transmissão, verificou-se que a incidência de Fop foi de 5 a 40% no hipocótilo e de 5 a 30% nas raízes de feijoeiro provenientes de sementes tratadas com os produtos.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Foi feita uma comparação entre os antígenos (Ag), preparados a partir dos vírus Maedi-Visna (MVV) e Artrite-encefalite Caprina (CAEV) para detecção de anticorpos contra o CAEV em 120 amostras de soro caprino. A sensibilidade e especificidade relativa da imunodifusão em ágar gel (IDAG) usando-se Ag MVV em relação ao Ag CAEV, foi 77,3% e 100%, respectivamente (X2, p<0,01). Assim, para diagnóstico de infecção pelo CAEV recomenda-se apenas o uso de Ag preparado a partir do CAEV.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

O objetivo deste trabalho foi o desenvolvimento de imunorreagentes policlonais convenientes para uso em um teste imunoenzimático para detecção rápida de Salmonella em alimentos. Foram produzidos seis anti-soros policlonais anti-Salmonella contendo as aglutininas e, h; 1,6; i; 1,2; f,g,s e m,t. Como antígenos, foram empregadas culturas formolizadas de quatro sorotipos de Salmonella (S. Typhimurium fases 1 e 2, S. Anatum fases 1 e 2, S. Agona monofásica e S. Oranienburg monofásica) cultivadas em caldo tripticase de soja. O teste imunoenzimático utilizado foi o indireto, empregando-se anti-IgG-peroxidase como conjugado e OPD-H2O2 como sistema cromógeno. Os testes imunoenzimáticos foram conduzidos com os anti-soros policlonais individuais absorvidos e não-absorvidos, bem como empregando-se um anti-soro polivalente, correspondente a um "pool" de anti-soros absorvidos e não-absorvidos com culturas puras de Salmonella e outras enterobactérias. A absorção dos soros eliminou as reações cruzadas com todas as enterobactérias testadas nesse estudo, apresentadas tanto por alguns anti-soros individuais quanto pelo polivalente. Entre os seis anti-soros estudados, os que apresentaram melhor desempenho foram o f,g,s não-absorvido e o polivalente absorvido.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study investigates the chemical species produced water from the reservoir areas of oil production in the field of Monte Alegre (onshore production) with a proposal of developing a model applied to the identification of the water produced in different zones or groups of zones.Starting from the concentrations of anions and cátions from water produced as input parameters in Linear Discriminate Analysis, it was possible to estimate and compare the model predictions respecting the particularities of their methods in order to ascertain which one would be most appropriate. The methods Resubstitution, Holdout Method and Lachenbruch were used for adjustment and general evaluation of the built models. Of the estimated models for Wells producing water for a single production area, the most suitable method was the "Holdout Method and had a hit rate of 90%. Discriminant functions (CV1, CV2 and CV3) estimated in this model were used to modeling new functions for samples ofartificial mixtures of produced water (producedin our laboratory) and samples of mixtures actualproduced water (water collected inwellsproducingmore thanonezone).The experiment with these mixtures was carried out according to a schedule experimental mixtures simplex type-centroid also was simulated in which the presence of water from steam injectionin these tanks fora part of amostras. Using graphs of two and three dimensions was possible to estimate the proportion of water in the production area