23 resultados para Telemetric
Resumo:
A case study of Atlantic Salmon runs into the R. Tyvi (S. Wales) is presented. Radio tracking of over 200 salmon in 1988 and 1989 has demonstrated that flow is an important factor in modifying both run timing and migratory success. Entry of salmon into the river is typically in response to flow events, and periods of low falling flows delay entry and may directly result in reduced runs into the river. Delayed entry may also increase the proportion of the run migrating after the end of both rod and net fishing seasons. The implications of these results for net and rod catch and catch/effort data are discussed, using both statutory reported catch data and data from specific catch/effort studies. Flow is demonstrated to be a dominant factor in determining the within-season distribution of rod catch and catch/effort during low-flow years. Estuarial seine net catch and catch/effort tend to be controlled more by time of return than by flow although low flows may delay runs. Annual reported rod catch is correlated with flow, which controls in season availability, catchability and consequently the amount of fishing effort. Use of catch or catch/effort data should take account of inter-year variations in flow and other environmental factors. Although catch and catch/effort are valuable indicators of fishery performance, they are inadequate to represent changing stock levels.
Resumo:
This paper describes a portable recording system and methods for obtaining chronic recordings of single units and tracking rhesus monkey behavior in an open field. The integrated system consists of four major components: (1) microelectrode assembly; (2) h
Resumo:
During this thesis a new telemetric recording system has been developed allowing ECoG/EEG recordings in freely behaving rodents (Lapray et al., 2008; Lapray et al., in press). This unit has been shown to not generate any discomfort in the implanted animals and to allow recordings in a wide range of environments. In the second part of this work the developed technique has been used to investigate what cortical activity was related to the process of novelty detection in rats’ barrel cortex. We showed that the detection of a novel object is accompanied in the barrel cortex by a transient burst of activity in the γ frequency range (40-47 Hz) around 200 ms after the whiskers contact with the object (Lapray et al., accepted). This activity was associated to a decrease in the lower range of γ frequencies (30-37 Hz). This network activity may represent the optimal oscillatory pattern for the propagation and storage of new information in memory related structures. The frequency as well as the timing of appearance correspond well with other studies concerning novelty detection related burst of activity in other sensory systems (Barcelo et al., 2006; Haenschel et al., 2000; Ranganath & Rainer, 2003). Here, the burst of activity is well suited to induce plastic and long-lasting modifications in neuronal circuits (Harris et al., 2003). The debate is still open whether synchronised activity in the brain is a part of information processing or an epiphenomenon (Shadlen & Movshon, 1999; Singer, 1999). The present work provides further evidence that neuronal network activity in the γ frequency range plays an important role in the neocortical processing of sensory stimuli and in higher cognitive functions.
Resumo:
In this paper, a prototype of miniaturized, low power, bi-directional wireless sensor node for wireless sensor networks (WSN) was designed for doors and windows building monitoring. The capacitive pressure sensors have been developed particularly for such application, where packaging size and minimization of the power requirements of the sensors are the major drivers. The capacitive pressure sensors have been fabricated using a 2.4 mum thick strain compensated heavily boron doped SiGeB diaphragm is presented. In order to integrate the sensors with the wireless module, the sensor dice was wire bonded onto TO package using chip on board (COB) technology. The telemetric link and its capabilities to send information for longer range have been significantly improved using a new design and optimization process. The simulation tool employed for this work was the Designerreg tool from Ansoft Corporation.
Resumo:
The ranging patterns of two male and five female spider monkeys (Ateles geoffroyi) were studied with the use of radio telemetry in Santa Rosa National Park, Costa Rica. The average size of a spider monkey home range was 62.4 hectares; however, range size varied with sex, and, for females, with the presence of a dependent infant. The probability of encountering a radio‐collared spider monkey in a three‐hour search using radio telemetry (0.91) was much greater than using a visual search (0.20), and telemetric data resulted in a larger estimate of mean home range size than did observational data, when all subjects were compared. However, the difference appeared to be owing to the presence of male ranges in the telemetric, but not the observational, data. When the size of home ranges derived from radio‐tracking data for adult females was compared to size of ranges for adult females derived from observations, the results were not significantly different. Adult males had larger home ranges than adult females, thus lending support to the hypothesis that males have adapted to the dispersion of females by occupying a large home range that overlaps the ranges of several adult females. The smallest home ranges were occupied by low‐weight females with dependent infants, perhaps reflecting social and energetic constraints. Copyright © 1988 Wiley‐Liss, Inc., A Wiley Company
Resumo:
User induced errors are common when women repetitively employ conventional probe type thermometers to chart their basal body temperatures in an effort to indicate ovulation. An alternative technique employing a two-part telemetric thermometer is proposed, with low-power, SAWR-controlled UHF radio as the transmission medium. Worn overnight in the vagina, the 1 mu W erp telemetry transmitter sends pulse modulated data continuously to a microcontroller in a nearby receiver; a real time clock enables programmable sampling and storage of the subject's temperature to 0.1 degrees C resolution. Initial clinical results indicate an enhanced performance compared to oral and axillary temperature trends taken by a mercury-in-glass thermometer. Polar plots of both the isolated and body-worn telemetry transmitte are presented; body indced attenuations of up to 30 dB were measured.
Resumo:
The indication for pulmonary artery banding is currently limited by several factors. Previous attempts have failed to produce adjustable pulmonary artery banding with reliable external regulation. An implantable, telemetrically controlled, battery-free device (FloWatch) developed by EndoArt SA, a medical company established in Lausanne, Switzerland, for externally adjustable pulmonary artery banding was evaluated on minipigs and proved to be effective for up to 6 months. The first human implant was performed on a girl with complete atrioventricular septal defect with unbalanced ventricles, large patent ductus arteriosus and pulmonary hypertension. At one month of age she underwent closure of the patent ductus arteriosus and FloWatch implantation around the pulmonary artery through conventional left thoracotomy. The surgical procedure was rapid and uneventful. During the entire postoperative period bedside adjustments (narrowing or release of pulmonary artery banding with echocardiographic assessment) were repeatedly required to maintain an adequate pressure gradient. The early clinical results demonstrated the clinical benefits of unlimited external telemetric adjustments. The next step will be a multi-centre clinical trial to confirm the early results and adapt therapeutic strategies to this promising technology.
Resumo:
Advent of lasers together with the advancement in fiber optics technology has revolutionized the sensor technology. Advancement in the telemetric applications of optical fiber based measurements is an added bonus. The present thesis describes variety of fiber based sensors using techniques like micro bending, long period grating and evanescent waves. Sensors to measure various physical and chemical parameters are described in this thesis.
Resumo:
Advances in hardware and software in the past decade allow to capture, record and process fast data streams at a large scale. The research area of data stream mining has emerged as a consequence from these advances in order to cope with the real time analysis of potentially large and changing data streams. Examples of data streams include Google searches, credit card transactions, telemetric data and data of continuous chemical production processes. In some cases the data can be processed in batches by traditional data mining approaches. However, in some applications it is required to analyse the data in real time as soon as it is being captured. Such cases are for example if the data stream is infinite, fast changing, or simply too large in size to be stored. One of the most important data mining techniques on data streams is classification. This involves training the classifier on the data stream in real time and adapting it to concept drifts. Most data stream classifiers are based on decision trees. However, it is well known in the data mining community that there is no single optimal algorithm. An algorithm may work well on one or several datasets but badly on others. This paper introduces eRules, a new rule based adaptive classifier for data streams, based on an evolving set of Rules. eRules induces a set of rules that is constantly evaluated and adapted to changes in the data stream by adding new and removing old rules. It is different from the more popular decision tree based classifiers as it tends to leave data instances rather unclassified than forcing a classification that could be wrong. The ongoing development of eRules aims to improve its accuracy further through dynamic parameter setting which will also address the problem of changing feature domain values.
Resumo:
Backgroud: Obesity is a major public health problem and is related to the low physical capacity when obese are compared to no-obese people, however the cause of this limitation is not completely understood. The measurement associated of physiological response to the telemetric 6MWT adds information of metabolic and respiratory system for diagnose of the functional limitation. Objective: Analyze physiological, metabolic and ventilatory responses in women with different body fat during the 6MWT. Methods: 32 women (8 non-obese, 8 Overweight, 8 Obese and 8 morbidly obese) were evaluated for anthropometry, lung function and exercise capacity. Results: Morbidly obese walked the shortest distance (400.2±38.7m), had lower VO2/Kg (12.75±3.20l/Kg/min) and lower R (0.74± 0.11) in the 6MWT compared to other groups. Analyses of metabolic (VO2 and VCO2) and respiratory (VE, VT and BF) during the test did not identify differences between groups. The evaluation of cardiac function (O2 pulse) found higher values in the OM (12.3 ± 4.9ml/bat). Conclusion: The OM had worse performance in the 6MWT compared to other groups. The physical performance may be reduced in this population related to a protocol-dependent response because the speed of 6MWT is self-adjusted allows the individual himself select the intensity of the test, making it set at a speed where there is energy saving
Resumo:
This work presents a methodological proposal for acquisition of biometric data through telemetry basing its development on a research-action and a case study. Nowadays, the qualified professionals of physical evaluation have to use specific devices to obtain biometric signals and data. These devices in the most of the time are high cost and difficult to use and handling. Therefore, the methodological proposal was elaborate in order to develop, conceptually, a bio telemetric device which could acquire the desirable biometric signals: oxymetry, biometrics, corporal temperature and pedometry which are essential for the area of physical evaluation. It was researched the existent biometrics sensors, the possible ways for the remote transmission of signals and the computer systems available so that the acquisition of data could be possible. This methodological proposal of remote acquisition of biometrical signals is structured in four modules: Acquisitor of biometrics data; Converser and transmitter of biometric signals; Receiver and Processor of biometrics signals and Generator of Interpretative Graphs. The modules aim the obtention of interpretative graphics of human biometric signals. In order to validate this proposal a functional prototype was developed and it is presented in the development of this work.
Resumo:
Objectives. Blood pressure (BP) physiologically has higher and lower values during the active and rest period, respectively. Subjects failing to show the appropriate BP decrease (10-20%) on passing form diurnal activity to nocturnal rest and sleep have increased risk of target organ damage at the cardiac, vascular and cerebrovascular levels. Hypocretin (HCRT) releasing neurons, mainly located in the lateral hypothalamus, project widely to the central nervous system. Thus HCRT neurons are involved in several autonomic functions, including BP regulation. HCRT neurons also play a key role in wake-sleep cycle regulation, the lack of which becomes evident in HCRT-deficient narcoleptic patients. I investigated whether chronic lack of HCRT signaling alters BP during sleep in mouse models of narcolepsy. Methods. The main study was performed on HCRT-ataxin3 transgenic mice (TG) with selective post-natal ablation of HCRT neurons, HCRT gene knockout mice (KO) with preserved HCRT neurons, and Wild-Type control mice (WT) with identical genetic background. Experiments where replicated on TG and WT mice with hybrid genetic background (hTG and hWT, respectively). Mice were implanted with a telemetric pressure transducer (TA11PA-C10, DSI) and electrodes for discriminating wakefulness (W), rapid-eye-movement sleep (REMS) and non-REMS (NREMS). Signals were recorded for 3 days. Mean BP values were computed in each wake-sleep state and analyzed by ANOVA and t-test with significance at p<0.05. Results. The decrease in BP between either NREMS or REMS and W was significantly blunted in TG and KO with respect to WT as well as in hTG with respect to hWT. Conclusions. Independently from the genetic background, chronic HCRT deficiency leads to a decreased BP difference between W and sleep potentially adverse in narcoleptic subjects. These data suggest that HCRT play an important role in the sleep-dependent cardiovascular control.