922 resultados para Technical failures


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To describe the use of self-expandable metallic stents to manage malignant colorectal obstructions and to compare the radiation dose between fluoroscopic guidance of stent placement and combined endoscopic and fluoroscopic guidance. Materials and Methods: From January 1998 to December 2007, 467 oncology patients undergoing colorectal stent placement in a single center were included in the study. Informed consent was obtained in all cases. All procedures were performed with fluoroscopic or combined fluoroscopic and endoscopic guidance. Inclusion criteria were total or partial colorectal obstruction of neoplastic origin. Exclusion criteria were life expectancy shorter than I month, suspicion of perforation, and/or severe colonic neoplastic bleeding. Procedure time and radiation dose were recorded, and technical and clinical success were evaluated. Follow-up was performed by clinical examination and simple abdominal radiographs at 1 day and at I, 3, 6, and 12 months. Results: Of 467 procedures, technical success was achieved in 432 (92.5%). Thirty-five treatments (7.5%) were technical failures, and the patients were advised to undergo surgery. Significant differences in radiation dose and clinical success were found between the fluoroscopy and combined-technique groups (P < .001). Total decompression was achieved in 372 cases, 29 patients showed remarkable improvement, 11 showed slight improvement, and 20 showed clinical failure. Complications were recorded in 89 patients (19%), the most significant were perforation (2.3%) and stent migration (6.9%). Mean interventional time and radiation dose were 67 minutes and 3,378 dGy.cm(2), respectively. Conclusions: Treatment of colonic obstruction with stents requires a long time in the interventional room and considerable radiation dose. Nevertheless, the clinical benefits and improvement in quality of life justify the radiation risk.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work focuses on the appraisal of public and environmental projects and, more specifically, on the calculation of the social discount rate (SDR) for this kind of very long-term investment projects. As a rule, we can state that the instantaneous discount rate must be equal to the hazard rate of the public good or to the mortality rate of the population that the project is intended to. The hazard can be due to technical failures of the system, but, in this paper, we are going to consider different independent variables that can cause the hazard. That is, we are going to consider a multivariate hazard rate. In our empirical application, the Spanish forest surface will be the system and the forest fire will be the fail that can be caused by several factors. The aim of this work is to integrate the different variables that produce the fail in the calculation of the SDR from a multivariate hazard rate approach.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the initial clinical experience with the Helex septal occluder for percutaneous closure of atrial septal defects. METHODS: Ten patients underwent the procedure, 7 patients with ostium secundum atrial septal defects (ASD) with hemodynamic repercussions and 3 patients with pervious foramen ovale (PFO) and a history of stroke. Mean age was 33.8 years and mean weight was 55.4 kg. Mean diameter by transesophageal echocardiography and mean stretched ASD diameter were 11.33 ± 3.3mm, and 15.2 ± 3.8mm, respectively. The Qp/Qs ratio was 1.9 ± 0.3 in patients with ASD. RESULTS: Eleven occluders were placed because a patient with 2 holes needed 2 devices. It was necessary to retrieve and replace 4 devices in 3 patients. We observed immediate residual shunt (< 2mm) in 4 patients with ASD, and in those with patent foramen ovale total occlusion of the defect occurred. No complications were noted, and all patients were discharged on the following day. After 1 month, 2 patients with ASD experienced trivial residual shunts (1mm). In 1 patient, we observed mild prolapse in the proximal disk in the right atrium, without consequences. CONCLUSION: The Helex septal occluder was safe and effective for occluding small to moderate atrial septal defects. Because the implantation technique is demanding, it requires specific training of the operator. Even so, small technical failures may occur in the beginning of the learning curve, but they do not involve patient safety.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: The AMS 800TM is the current artificial urinary sphincter (AUS) for incontinence due to intrinsic sphincter deficiency. Despite good clinical results, technical failures inherent to the hydraulic mechanism or urethral ischemic injury contribute to revisions up to 60%. We are developing an electronic AUS, called ARTUS to overcome the rigors of AMS. The objective of this study was to evaluate the technical efficacy and tissue tolerance of the ARTUS system in an animal model.Methods: The ARTUS is composed by three parts: the contractile unit, a series of rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor. In the first phase a three-rings device was used while in the second phase a two-rings ARTUS was used. The device was implanted in 14 sheep divided in two groups of six and eight animals for study purpose. The first group aimed at bladder leak point pressure (BLPP) measurement and validation of the animal model; the second group aimed at verifying mid-term tissue tolerance by explants at twelve weeks. General animal tolerance was also evaluated.Results: The ARTUS system implantation was uneventful. When the system was activated, the BLPP was measured at 1.038±0.044 bar (mean±SD). Urethral tissue analysis did not show significant morphological changes. No infection and no sign of discomfort were noted in animals at 12 weeks.Conclusions: The ARTUS proved to be effective in continence achievement in this study. Histological results support our idea that a sequential alternative mode can avoid urethral atrophy and ischemia. Further technical developments are needed to verify long-term outcome and permit human use.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Percutaneous transluminal coronary angioplasty (PTCA) is a widely accepted treatment of symptomatic coronary heart disease providing prompt and prolonged clinical, improvement in most patients. We have examined the value of this therapy in a group of 91 patients in their eighth decade treated by 133 consecutive angioplasties. Most patients had refractory or instable angor in spite of optimal pharmacotherapy. Multivessel disease was present in 67% and maintained left-ventricular function in 92% of the patients. The angiographic success rate of PTCA was 84%; technical failures occurred in 12% and adverse events in 14%. Two patients died. The rate of symptomatic restenosis was 24%. Survival and patients free of myocardial events were at 89% and 60%, respectively, estimated by Kaplan-Meier analysis. PTCA is an efficient and acceptable treatment for the elderly patient with severe and drug-resistant angina. Two years after PTCA the majority of patients was asymptomatic.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Peritoneal dialysis is an extrarenal epuration modality which uses physiological properties of peritoneum as a dialysis membrane. Despite the improvement of peritoneal dialysis techniques in the last ten years, peritonitis remains one of the most redoubt complications. Peritonitis may sometimes lead to technical failures, which need catheter removing, but rarely lead to death. Our retrospective study at the dialysis center of CHUV has analyzed factors which can predict this kind of complication. It calculates peritonitis rate and median peritonitis free-survival for different groups of patients. It also describes causatives organisms and their sensitivity to antibiotics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: The AMS 800 is the current artifi cial urinary sphincter (AUS) forincontinence due to intrinsic sphincter defi ciency. Despite good clinical results,technical failures inherent to the hydraulic mechanism or urethral ischemicinjury contribute to revisions up to 60%. We are developing an electronic AUS,called ARTUS to overcome the rigors of AMS. The objective of this study wasto evaluate the technical effi cacy and tissue tolerance of the ARTUS systemin an animal model.Methods: The ARTUS is composed by three parts: thecontractile unit, a series of rings and an integrated microprocessor. The contractileunit is made of Nitinol fi bers. The rings are placed around the urethrato control the fl ow of urine by squeezing the urethra. They work in a sequentialalternative mode and are controlled by a microprocessor. In the fi rst phase athree-rings device was used while in the second phase a two-rings ARTUS wasused. The device was implanted in 14 sheep divided in two groups of six andeight animals for study purpose. The fi rst group aimed at bladder leak pointpressure (BLPP) measurement and validation of the animal model; the secondgroup aimed at verifying midterm tissue tolerance by explants at twelve weeks.General animal tolerance was also evaluated.Results: The ARTUS systemimplantation was uneventful. When the system was activated, the BLPP wasmeasured at 1.038 ± 0.044 bar (mean ± SD). Urethral tissue analysis did notshow signifi cant morphological changes. No infection and no sign of discomfortwere noted in animals at 12 weeks.Conclusions: The ARTUS proved to beeffective in continence achievement in this study. Histological results supportour idea that a sequential alternative mode can avoid urethral atrophy andischemia. Further technical developments are needed to verify long-termoutcome and permit human use.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To determine whether an increase in the rate of undesirable events occurs after care provided by trainees at the beginning of the academic year. DESIGN: Retrospective cohort study using administrative and patient record data. SETTING: University affiliated hospital in Melbourne, Australia. PARTICIPANTS: 19,560 patients having an anaesthetic procedure carried out by first to fifth year trainees starting work for the first time at the hospital over a period of five years (1995-2000). MAIN OUTCOME MEASURES: Absolute event rates, absolute rate reduction, and rate ratios of undesirable events. RESULTS: The rate of undesirable events was higher at the beginning of the academic year compared with the rest of the year (absolute event rate 137 v 107 per 1000 patient hours, relative rate reduction 28%, P<0.001). The overall adjusted rate ratio for undesirable events was 1.40, 95% confidence interval 1.24 to 1.58. This excess risk was seen for all residents, regardless of their level of seniority. The excess risk decreased progressively after the first month, and the trend disappeared fully after the fourth month of the year (rate ratio for fourth month 1.21, 0.93 to 1.57). The most important decreases were for central and peripheral nerve injuries (relative difference 82%), inadequate oxygenation of the patient (66%), vomiting/aspiration in theatre (53%), and technical failures of tracheal tube placement (49%). CONCLUSIONS: The rate of undesirable events was greater among trainees at the beginning of the academic year regardless of their level of clinical experience. This suggests that several additional factors, such as knowledge of the working environment, teamwork, and communication, may contribute to the increase.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis concentrates on studying the operational disturbance behavior of machine tools integrated into FMS. Operational disturbances are short term failures of machine tools which are especially disruptive to unattended or unmanned operation of FMS. The main objective was to examine the effect of operational disturbances on reliability and operation time distribution for machine tools. The theoretical part of the thesis covers the fimdamentals of FMS relating to the subject of this study. The concept of FMS, its benefits and operator's role in FMS operation are reviewed. The importance of reliability is presented. The terms describing the operation time of machine tools are formed by adopting standards and references. The concept of failure and indicators describing reliability and operational performance for machine tools in FMSs are presented. The empirical part of the thesis describes the research methodology which is a combination of automated (ADC) and manual data collection. By using this methodology it is possible to have a complete view of the operation time distribution for studied machine tools. Data collection was carried out in four FMSs consisting of a total of 17 machine tools. Each FMS's basic features and the signals of ADC are described. The indicators describing the reliability and operation time distribution of machine tools were calculated according to collected data. The results showed that operational disturbances have a significant influence on machine tool reliability and operational performance. On average, an operational disturbance occurs every 8,6 hours of operation time and has a down time of 0,53 hours. Operational disturbances cause a 9,4% loss in operation time which is twice the amount of losses caused by technical failures (4,3%). Operational disturbances have a decreasing influence on the utilization rate. A poor operational disturbance behavior decreases the utilization rate. It was found that the features of a part family to be machined and the method technology related to it are defining the operational disturbance behavior of the machine tool. Main causes for operational disturbances were related to material quality variations, tool maintenance, NC program errors, ATC and machine tool control. Operator's role was emphasized. It was found that failure recording activity of the operators correlates with the utilization rate. The more precisely the operators record the failure, the higher is the utilization rate. Also the FMS organizations which record failures more precisely have fewer operational disturbances.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A regulação ambiental carece de maior transparência. Os órgãos de proteção do meio ambiente, em regra, apenas publicam as versões finais das medidas elaboradas, sem explicitar as justificativas técnicas que as embasaram, as alternativas consideradas e as possíveis contribuições decorrentes de participação social, entre outras questões. Em consequência, tem-se um cenário desfavorável à realização de controle pelos mais diversos atores. Para superá-lo, a análise de impacto regulatório é apresentada como instrumento apto a agregar clareza, objetividade e eficiência ao processo decisório ambiental. A incorporação da ferramenta, no entanto, deve ser realizada com cuidado especial, tendo em vista a existência de três principais peculiaridades do direito do meio ambiente. Primeiro, o setor lida não só com situações de risco, mas também com casos de incerteza, em que a ausência de informação impossibilita o cálculo de probabilidade de ocorrência de possíveis resultados. Em segundo lugar, a regulação ambiental recai sobre bens não transacionados em mercados, o que dificulta a obtenção de seu valor de troca, aspecto relevante para a análise de custo-benefício como tradicionalmente conhecida. Por fim, o meio ambiente apresenta desenho regulatório absolutamente fragmentado, composto por variados órgãos normatizadores, deliberativos e fiscalizadores em todos os níveis da federação, o que eleva o risco de deficiências na formação técnica das autoridades reguladoras.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Especificar e quantificar as principais falhas técnicas, sejam elas eletrônicas ou mecânicas, presentes em radiografias convencionais de tórax, com o intuito de melhorar a sua qualidade e reduzir a necessidade da repetição dos exames e, consequentemente, a dose recebida pelo paciente. MATERIAIS E MÉTODOS: Foram selecionadas e avaliadas por um pneumologista 897 radiografias convencionais realizadas ou em projeção posteroanterior ou lateral em cinco instituições de saúde da cidade de São Paulo. em cada uma delas foram feitas análises das falhas técnicas presentes, as quais foram classificadas de acordo com o erro técnico radiográfico pré-definido e que levou à repetição do exame. RESULTADOS: Os resultados obtidos mostraram que o posicionamento incorreto do paciente (27%), a subexposição (23%) e a superexposição (15%) foram as principais falhas que contribuíram para a repetição dos exames e que apresentaram, na matriz de coeficiente de correlação Pearson, um erro acima de 0,7%, ocasionando aumento da dose recebida pelos pacientes. CONCLUSÃO: Os resultados observados indicaram a necessidade da realização de controle de qualidade dos aparelhos de raios X, a atenção do operador do equipamento, bem como outras abordagens para esclarecer o impacto da necessidade de repetição do exame.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this study we present the technical details, adaptations and modifications of the original procedure of pancreaticoduodenal transplantation in rats described by Lee et al. in 1972. We also present the results and technical failures observed in a follow-up of 12 years. From March, 1982 to December, 1994, we performed in the Laboratory of Surgical Technique and Experimental Surgery of Faculty of Medicine, Botucatu - UNESP, Brazil, 665 duodenopancreatectomies in donor rats and 592 surgeries for revascularization of the pancreatic graft in recipient animals. The observed percentage of technical failures in donor rats was 11% due to bleeding and/or vascular complications, irregular flushing of the graft with saline and respiratory insufficiency. In recipients of grafts, we observed a percentage of technical failures of 22,5% due to porto-caval thrombosis, vascular bleeding, pancreatitis and graft ischemia. In both surgeries, the successful results are directly related to the technical performance of the surgeon and the cares in the postoperative period.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This report elaborates on the master degree thesis developed by the candidate within the company Superjet International. The performed activity focuses on the study and design of VAMP (Virtual Aircraft Multipurpose Platform). VAMP is a new interactive platform, not necessarily limited to the Aeronautical sector, aimed to analyse technical failures, identify risk and recommend the most appropriate corrective actions for maintenance cost reduction, taking into account reliability, availability, maintainability and safety.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUÇÃO: Durante procedimentos endovasculares, estão presentes os riscos relacionados ao uso dos contrastes iodados, tais como a nefropatia por contraste, uma vez que é fundamental o emprego de um meio de contraste para a obtenção das imagens radiológicas vasculares. A injeção intravascular de gás CO2 purificado é reconhecidamente uma alternativa relativamente mais segura ao contraste iodado, contudo, seu manuseio artesanal pode também trazer dificuldades técnicas e riscos aos pacientes. Para contemplar estas questões, foi desenvolvido o protótipo de um injetor intravascular de CO2 medicinal, microprocessado, dedicado à obtenção de imagens angiográficas. OBJETIVOS: Realizar os testes de viabilidade técnica inicial do protótipo em modelo in vivo. MÉTODOS: Realizar a angioplastia da artéria renal esquerda de 10 porcos, divididos em 2 grupos: Grupo 1 (n=5) injeção de contraste iodado, Grupo 2 (n=5) injeção de CO2 através do protótipo. Monitorização clínica e laboratorial dos animais no pré, intra e pós-operatório, com exames de função renal na véspera e 48h após os procedimentos e 3 gasometrias arteriais seriadas no intra-operatório. Observação clínica foi mantida por 48h no pós- operatório. RESULTADOS: Os procedimentos de angioplastia com CO2 foram realizados com sucesso técnico de 100%, sem necessidade de complementação com injeção de contraste iodado no Grupo 2. Não foram identificadas falhas no protótipo em funcionamento. Não foram identificadas alterações clínicas ou radiológicas sugestivas de contaminação por ar ambiente do sistema de CO2 e nem alterações laboratoriais nos animais. As imagens angiográficas obtidas no Grupo 2 foram consideradas, numa avaliação subjetiva, relativamente inferiores às imagens obtidas no Grupo 1. DISCUSSÃO: A qualidade inferior de imagem no Grupo 2 pode ser atribuída ao equipamento de fluoroscopia utilizado, com software desatualizado em relação aos equipamentos atuais, que incluem pré-configurações para angiografia com CO2; no entanto, ainda assim todos os procedimentos propostos no Grupo 2 foram realizados com sucesso técnico, o que nos leva a classificar as imagens deste grupo 2 como satisfatórias. O manuseio do aparelho mostrou-se ágil e eficiente, com a programação dos parâmetros sendo realizada com facilidade através do visor \"touch screen\", comparativamente superior ao método artesanal de injeção de CO2 com seringas em selo d\'água. CONCLUSÕES: O protótipo do aparelho injetor intravascular de CO2 funcionou de forma adequada durante os testes e as imagens obtidas permitiram a compleição com sucesso dos procedimentos. Portanto, os resultados positivos obtidos sugerem que o equipamento é tecnicamente viável

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The efficiency of airport airside operations is often compromised by unplanned disruptive events of different kinds, such as bad weather, strikes or technical failures, which negatively influence the punctuality and regularity of operations, causing serious delays and unexpected congestion. They may provoke important impacts and economic losses on passengers, airlines and airport operators, and consequences may propagate in the air network throughout different airports. In order to identify strategies to cope with such events and minimize their impacts, it is crucial to understand how disruptive events affect airports’ performance. The research field related with the risk of severe air transport network disruptions and their impact on society is related to the concepts of vulnerability and resilience. The main objective of this project is to provide a framework that allows to evaluate performance losses and consequences due to unexpected disruptions affecting airport airside operations, supporting the development of a methodology for estimating vulnerability and resilience indicators for airport airside operations. The methodology proposed comprises three phases. In the first phase, airside operations are modelled in both the baseline and disrupted scenarios. The model includes all main airside processes and takes into consideration the uncertainties and dynamics of the system. In the second phase, the model is implemented by using a generic simulation software, AnyLogic. Vulnerability is evaluated by taking into consideration the costs related to flight delays, cancellations and diversions; resilience is determined as a function of the loss of capacity during the entire period of disruption. In the third phase, a Bayesian Network is built in which uncertain variables refer to airport characteristics and disruption type. The Bayesian Network expresses the conditional dependence among these variables and allows to predict the impacts of disruptions on an airside system, determining the elements which influence the system resilience the most.