935 resultados para Technical endoscopy


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background Roux-en-Y gastric bypass (RYGB) is amongst the commonest surgical intervention for weight loss in obese patients. Gastrocutaneous fistula, which usually occurs along the vertical staple line of the pouch, is amongst its most alarming complications. Medical management comprised of wound drainage, nutritional support, acid suppression, and antibiotics may be ineffective in as many as a third of patients with this complication. We present outcomes after endoscopic application of SurgiSIS (R), which is a novel biomaterial for the treatment of this complication. Design A case series of 25 patients. Methods Twenty-five patients who had failed conservative medical management of gastrocutaneous fistula after RYGB underwent endoscopic application of SurgiSIS (R)-an acellular fibrogenic matrix biomaterial to help fistula healing. Main outcome measures Fistula closure as assessed by upper gastrointestinal imaging and endoscopic examination. Results In patients who had failed medical management lasting 4-25 (median, 7) weeks, closure of the fistulous tract was successful after one application in six patients (30%), two applications in 11 patients (55%), and three applications in three patients (15%). There were no procedure-related complications. Conclusions Endoscopic application of SurgiSIS (R)-an acellular fibrogenic matrix-is safe and effective for the treatment of gastrocutaneous fistula after RYGB.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Wireless capsule endoscopy has been introduced as an innovative, non-invasive diagnostic technique for evaluation of the gastrointestinal tract, reaching places where conventional endoscopy is unable to. However, the output of this technique is an 8 hours video, whose analysis by the expert physician is very time consuming. Thus, a computer assisted diagnosis tool to help the physicians to evaluate CE exams faster and more accurately is an important technical challenge and an excellent economical opportunity. METHOD: The set of features proposed in this paper to code textural information is based on statistical modeling of second order textural measures extracted from co-occurrence matrices. To cope with both joint and marginal non-Gaussianity of second order textural measures, higher order moments are used. These statistical moments are taken from the two-dimensional color-scale feature space, where two different scales are considered. Second and higher order moments of textural measures are computed from the co-occurrence matrices computed from images synthesized by the inverse wavelet transform of the wavelet transform containing only the selected scales for the three color channels. The dimensionality of the data is reduced by using Principal Component Analysis. RESULTS: The proposed textural features are then used as the input of a classifier based on artificial neural networks. Classification performances of 93.1% specificity and 93.9% sensitivity are achieved on real data. These promising results open the path towards a deeper study regarding the applicability of this algorithm in computer aided diagnosis systems to assist physicians in their clinical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wireless capsule endoscopy (CE) is a technology developed for the endoscopic exploration of the small bowel. The first capsule model was approved by the Food and Drug Administration in 2001, and its first and essential indication was occult gastrointestinal (GI) bleeding. Over subsequent years, this technology has been refined to provide superior resolution, increased battery life, and capabilities to view different parts of the GI tract. Indeed, cases for which CE proved useful have increased significantly over the last few years, with new indications for the small bowel and technical improvements that have expanded its use to other parts of the GI tract, including the esophagus and colon. The main challenges in the development of CE are new devices with the ability to provide therapy, air inflation for a better vision of the small bowel, biopsy sampling systems attached to the capsule and the possibility to guide and move the capsule with an external motion control. In this article we review the current and new indications of CE, and the evolving technological changes shaping this technology, which has a promising potential in the coming future of gastroenterology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The quality of colon cleansing is a major determinant of quality of colonoscopy. To our knowledge, the impact of bowel preparation on the quality of colonoscopy has not been assessed prospectively in a large multicenter study. Therefore, this study assessed the factors that determine colon-cleansing quality and the impact of cleansing quality on the technical performance and diagnostic yield of colonoscopy. METHODS: Twenty-one centers from 11 countries participated in this prospective observational study. Colon-cleansing quality was assessed on a 5-point scale and was categorized on 3 levels. The clinical indication for colonoscopy, diagnoses, and technical parameters related to colonoscopy were recorded. RESULTS: A total of 5832 patients were included in the study (48.7% men, mean age 57.6 [15.9] years). Cleansing quality was lower in elderly patients and in patients in the hospital. Procedures in poorly prepared patients were longer, more difficult, and more often incomplete. The detection of polyps of any size depended on cleansing quality: odds ratio (OR) 1.73: 95% confidence interval (CI)[1.28, 2.36] for intermediate-quality compared with low-quality preparation; and OR 1.46: 95% CI[1.11, 1.93] for high-quality compared with low-quality preparation. For polyps >10 mm in size, corresponding ORs were 1.0 for low-quality cleansing, OR 1.83: 95% CI[1.11, 3.05] for intermediate-quality cleansing, and OR 1.72: 95% CI[1.11, 2.67] for high-quality cleansing. Cancers were not detected less frequently in the case of poor preparation. CONCLUSIONS: Cleansing quality critically determines quality, difficulty, speed, and completeness of colonoscopy, and is lower in hospitalized patients and patients with higher levels of comorbid conditions. The proportion of patients who undergo polypectomy increases with higher cleansing quality, whereas colon cancer detection does not seem to critically depend on the quality of bowel preparation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Laryngeal Electromyography (LEMG) is an auxiliary diagnostic method used for the comprehension and diagnosis of different neurological diseases that compromise laryngeal function. The most common LEMG technique is the percutaneous insertion of needle electrodes guided by surface anatomical references. We describe techniques for inserting needle electrodes into the tireoaritenoideus (TA), cricotireoideus (CT), cricoaritenoideus lateralis (CAL) and cricoaritenoideus posterioris (CAP) muscles; these are used at UNICAMP laryngology ambulatory; we discuss difficulties found and their proposed solutions. All patients were submitted to otorhinolaryngological, phonoaudiological and laryngeal endoscopy before LEMG. The CAP approach, by digital rotation of the thyroid cartilage was found to be the most difficult, followed by the CAL approach. TA and CT approaches gave no major problems, except with some older and obese patients. A significant complication of the TA approach via thyroid cartilage was a hematoma in one patient which partially obstructed the laryngeal lumen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim of this study was to analyse contact endoscopy as an auxiliary method for identifying parathyroid glands during thyroid surgery and to identify other variables that may interfere with this correlation. overall, 125 patients underwent thyroid surgery between January 2004 and February 2006. The variables analysed were: the total duration of surgery; time taken to locate and identify parathyroid glands; improvement in identifying these; numbers of parathyroid glands located by the surgeon and confirmed by contact endoscopy; histopathological diagnosis; presence of thyroiditis; thyroid weight; number of parathyroid glands left in thyroid specimens; and number of parathyroid gland autotransplantations. A total of 331 parathyroid glands were observed by the surgeon. however, 282 glands were identified by contact endoscopy. nine parathyroid glands (7.2%) were observed together with thyroid specimens (Kappa = 0.534). The longer the total duration of surgery (p = 0.03) and time taken to locate and identify (p = 0.00) the parathyroid glands by contact endoscopy, the lower the observed agreement. The second year of performing contact endoscopy led to better agreement between the results (p = 0.02). in conclusion, contact endoscopy is an efficient auxiliary method for identifying parathyroid glands during thyroid surgery. During the period studied, association between total duration of surgery and time taken to locate and identify parathyroid glands was statistically significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Highly active antiretroviral therapy (HAART) has dramatically decreased opportunistic infections (OIs) in human immunodeficiency virus (HIV)-infected patients. However, gastrointestinal disease continues to account for a high proportion of presenting symptoms in these patients. Gastrointestinal symptoms in treated patients who respond to therapy are more likely to the result of drug-induced complications than OI. Endoscopi evaluation of the gastrointestinal tract remains a cornerstone of diagnosis, especially in patients with advanced immunodeficiency, who are at risk for OI. The peripheral blood CD4 lymphocyte count helps to predict the risk of an OI, with the highest risk seen in HIV-infected patients with low CD4 count (< 200 cells/mm(3)). This review provides an update of the role of endoscopy in diagnosing OI in the upper gastrointestinal tract in HIV-infected patients in the era of HAART. (C) 2009 The WJG Press and Baishideng. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, we evaluated alternative technical markers for the motion analysis of the pelvic segment. Thirteen subjects walked eight times while tri-dimensional kinematics were recorded for one stride of each trial. Five marker sets were evaluated, and we compared the tilt, obliquity, and rotation angles of the pelvis segment: (1) standard: markers at the anterior and posterior superior iliac spines (ASIS and PSIS); (2) markers at the PSIS and at the hip joint centers, HJCs (estimated by a functional method and described with clusters of markers at the thighs); (3) markers at the PSIS and HJCs (estimated by a predictive method and described with clusters of markers at the thighs); (4) markers at the PSIS and HJCs (estimated by a predictive method and described with skin-mounted markers at the thighs based on the Helen-Hayes marker set); (5) markers at the PSIS and at the iliac spines. Concerning the pelvic angles, evaluation of the alternative technical marker sets evinced that all marker sets demonstrated similar precision across trials (about 1 degrees) but different accuracies (ranging from 1 degrees to 3 degrees) in comparison to the standard marker set. We suggest that all the investigated marker sets are reliable alternatives to the standard pelvic marker set. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The photodegradation of the herbicide clomazone in the presence of S(2)O(8)(2-) or of humic substances of different origin was investigated. A value of (9.4 +/- 0.4) x 10(8) m(-1) s(-1) was measured for the bimolecular rate constant for the reaction of sulfate radicals with clomazone in flash-photolysis experiments. Steady state photolysis of peroxydisulfate, leading to the formation of the sulfate radicals, in the presence of clomazone was shown to be an efficient photodegradation method of the herbicide. This is a relevant result regarding the in situ chemical oxidation procedures involving peroxydisulfate as the oxidant. The main reaction products are 2-chlorobenzylalcohol and 2-chlorobenzaldehyde. The degradation kinetics of clomazone was also studied under steady state conditions induced by photolysis of Aldrich humic acid or a vermicompost extract (VCE). The results indicate that singlet oxygen is the main species responsible for clomazone degradation. The quantum yield of O(2)(a(1)Delta(g)) generation (lambda = 400 nm) for the VCE in D(2)O, Phi(Delta) = (1.3 +/- 0.1) x 10(-3), was determined by measuring the O(2)(a(1)Delta(g)) phosphorescence at 1270 nm. The value of the overall quenching constant of O(2)(a(1)Delta(g)) by clomazone was found to be (5.7 +/- 0.3) x 10(7) m(-1) s(-1) in D(2)O. The bimolecular rate constant for the reaction of clomazone with singlet oxygen was k(r) = (5.4 +/- 0.1) x 10(7) m(-1) s(-1), which means that the quenching process is mainly reactive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plantation spacing selection has the primary objective of assigning each tree enough space for maximum growth and best quality to be attained with a minimum cost. From the harvest standpoint, an increase in stand density directly implies a decrease of individual tree volume, reducing also harvester productive capacity. The objective of this research is to assess the effects of several initial spacings and arrangements in eucalyptus plantations on production capacity, operational capacity and costs of forest harvester. Real operational data were collected from two eucalypt plantations at different initial spacing of 6.0, 7.5, 9.0, 12 and 18 m(2) per tree. Simulation data were obtained from a forest harvester simulator. Using spacing (E), mean tree volume (MV), diameter at breast height (DBH) and height (H) values, a stepwise regression test procedure was run, and correlations computed in order to measure their participation in operational capacity. Operational costs were computed with an accounting method proposed by FAO. Mean tree volume (MV) explained 88% of forest harvester operational capacity. Spacing (E) affected 8.5% of harvester operational capacity; wider spacings were related to higher individual tree volumes. Harvesting operation costs were lower in wider spaced treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Brazilian Network of Food Data Systems (BRASILFOODS) has been keeping the Brazilian Food Composition Database-USP (TBCA-USP) (http://www.fcf.usp.br/tabela) since 1998. Besides the constant compilation, analysis and update work in the database, the network tries to innovate through the introduction of food information that may contribute to decrease the risk for non-transmissible chronic diseases, such as the profile of carbohydrates and flavonoids in foods. In 2008, data on carbohydrates, individually analyzed, of 112 foods, and 41 data related to the glycemic response produced by foods widely consumed in the country were included in the TBCA-USP. Data (773) about the different flavonoid subclasses of 197 Brazilian foods were compiled and the quality of each data was evaluated according to the USDAs data quality evaluation system. In 2007, BRASILFOODS/USP and INFOODS/FAO organized the 7th International Food Data Conference ""Food Composition and Biodiversity"". This conference was a unique opportunity for interaction between renowned researchers and participants from several countries and it allowed the discussion of aspects that may improve the food composition area. During the period, the LATINFOODS Regional Technical Compilation Committee and BRASILFOODS disseminated to Latin America the Form and Manual for Data Compilation, version 2009, ministered a Food Composition Data Compilation course and developed many activities related to data production and compilation. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study is an integral part of a research project which seeks the establishment of protocols for the production of standardized herbal dried extracts emphasizing the spouted bed drying. This thesis was conducted at faculty of Pharmaceutical Science of Ribeiro Preto/University of So Paulo, Brazil, under supervision of Prof. Dr. Wanderley Pereira Oliveira*, defended on September 28, 2007.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This technical appendix details the methods used in an assessment of the potential of snus for tobacco harm reduction using simulation modelling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article seeks to retrace some of the empirical, historical and sociological elements of Max Weber Sociology of music. Even if he is first and foremost interested in the process of rationalisation throughout western civilisation, his Sociology of music is founded on the idea of the technical medium, which he explores in several different directions. This idea will be examined here by means of several examples drawn from western music, particularly from the romantic piano repertoire.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hepatectomy may prolong the survival of colorectal cancer patients with liver metastases. Two-stage liver surgery is a valid option for the treatment of bilobar colorectal liver metastasis. This video demonstrates technical aspects of a two-stage pure laparoscopic hepatectomy for bilateral liver metastasis. To the authors` knowledge, this is the first description of a two-stage laparoscopic liver resection in the English literature. A 54-year-old man with right colon cancer and synchronous bilobar colorectal liver metastasis underwent laparoscopic right colon resection followed by oxaliplatin-based chemotherapy. The patient then was referred for surgical treatment of liver metastasis. Liver volumetry showed a small left liver remnant. Surgical planning was for a totally laparoscopic two-stage liver resection. The first stage involved laparoscopic resection of segment 3 and ligature of the right portal vein. The postoperative pathology showed high-grade liver steatosis. After 4 weeks, the left liver had regenerated, and volumetry of left liver was 43%. The second stage involved laparoscopic right hepatectomy using the intrahepatic Glissonian approach. Intrahepatic access to the main right Glissonian pedicle was achieved with two small incisions, and an endoscopic vascular stapling device was inserted between these incisions and fired. The line of liver transection was marked following the ischemic area. Liver transection was accomplished with the Harmonic scalpel and an endoscopic stapling device. The specimen was extracted through a suprapubic incision. The falciform ligament was fixed to maintain the left liver in its original anatomic position, avoiding hepatic vein kinking and outflow syndrome. The operative time was 90 min for stage 1 and 240 min for stage 2 of the procedure. The recoveries after the first and second operations were uneventful, and the patient was discharged on postoperative days 2 and 7, respectively. Two-stage liver resections can be performed safely using laparoscopy. The intrahepatic Glissonian approach is a useful tool for pedicle control of the right liver, especially after previous dissection of the hilar plate.