974 resultados para Tear film stability


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: With the potential to address evaporative dry eye, a novel spray has been developed in which phospholipid liposomes are delivered to the tear film via the surface of the closed eyelid. This study evaluated the short-term effects of liposomal spray application on the lipid and stability characteristics of the pre-ocular tear film in normal eyes. Methods: Twenty-two subjects (12M, 10F) aged 35.1 ± 7.1 years participated in this prospective, randomised, double-masked investigation in which the liposomal spray was applied to one eye, and an equal volume of saline spray (control) applied to the contralateral eye. Lipid layer grade (LLG), non-invasive tear film stability (NIBUT) and tear meniscus height (TMH) were evaluated at baseline, and at 30, 60, 90 and 135 minutes post-application. Subjective reports of comfort were also compared. Results: Treated and control eyes were not significantly different at baseline (p>0.05). Post-application, LLG increased significantly, at 30 and 60 minutes, only in the treated eyes (p=0.005). NIBUT also increased significantly in the treated eyes only (p<0.001), at 30, 60 and 90 minutes. TMH did not alter significantly (p>0.05). Comfort improved relative to baseline in 46% of treated and 18% of control eyes, respectively, at 30 minutes post-application. Of those expressing a preference in comfort between the eyes, 68% preferred the liposomal spray. Conclusions: Consistent with subjective reports of improved comfort, statistically and clinically significant improvements in lipid layer thickness and tear film stability are observed in normal eyes for at least an hour after a single application of a phospholipid liposomal spray.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate eyelid temperature change and short-term effects on tear film stability and lipid layer thickness in healthy patients using a commercially available warm compress (MGDRx EyeBag) for ophthalmic use. Methods: Eyelid temperature, noninvasive tear film breakup time (NITBUT), and tear film lipid layer thickness (TFLLT) of 22 healthy subjects were measured at baseline, immediately after, and 10 minutes after application of a heated eyebag for 5 minutes to one eye selected at random. A nonheated eyebag was applied to the contralateral eye as a control. Results: Eyelid temperatures, NITBUT, and TFLLT increased significantly from baseline in test eyes immediately after removal of the heated eyebag compared with those in control eyes (maximum temperature change, 2.3 +/- 1.2[degrees]C vs. 0.3 +/- 0.5[degrees]C, F = 20.533, p < 0.001; NITBUT change, 4.0 +/- 2.3 seconds vs. 0.4 +/- 1.7 seconds, p < 0.001; TFLLT change, 2.0 +/- 0.9 grades vs. 0.1 +/- 0.4 grades, Z = -4.035, p < 0.001). After 10 minutes, measurements remained significantly higher than those in controls (maximum temperature change, 1.0 +/- 0.7[degrees]C vs. 0.1 +/- 0.3[degrees]C, F = 14.247, p < 0.001; NITBUT change, 3.6 +/- 2.1 seconds vs. 0.1 +/- 1.9 seconds, p < 0.001; TFLLT change, 1.5 +/- 0.9 vs. 0.2 +/- 0.5 grades, Z = -3.835, p < 0.001). No adverse events occurred during the study. Conclusions: The MGDRx EyeBag is a simple device for heating the eyelids, resulting in increased NITBUT and TFLLT in subjects without meibomian gland dysfunction that seem to be clinically significant. Future studies are required to determine clinical efficacy and evaluate safety after long-term therapy in meibomian gland dysfunction patients. © 2013 American Academy of Optometry

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate eyelid temperature change and short-term effects on tear film stability and lipid layer thickness in healthy patients using a commercially available warm compress (MGDRx EyeBag) for ophthalmic use. METHODS: Eyelid temperature, noninvasive tear film breakup time (NITBUT), and tear film lipid layer thickness (TFLLT) of 22 healthy subjects were measured at baseline, immediately after, and 10 minutes after application of a heated eyebag for 5 minutes to one eye selected at random. A nonheated eyebag was applied to the contralateral eye as a control. RESULTS: Eyelid temperatures, NITBUT, and TFLLT increased significantly from baseline in test eyes immediately after removal of the heated eyebag compared with those in control eyes (maximum temperature change, 2.3 ± 1.2 °C vs. 0.3 ± 0.5 °C, F = 20.533, p <0.001; NITBUT change, 4.0 ± 2.3 seconds vs. 0.4 ± 1.7 seconds, p <0.001; TFLLT change, 2.0 ± 0.9 grades vs. 0.1 ± 0.4 grades, Z = -4.035, p <0.001). After 10 minutes, measurements remained significantly higher than those in controls (maximum temperature change, 1.0 ± 0.7 °C vs. 0.1 ± 0.3 °C, F = 14.247, p <0.001; NITBUT change, 3.6 ± 2.1 seconds vs. 0.1 ± 1.9 seconds, p <0.001; TFLLT change, 1.5 ± 0.9 vs. 0.2 ± 0.5 grades, Z = -3.835, p <0.001). No adverse events occurred during the study. CONCLUSIONS: The MGDRx EyeBag is a simple device for heating the eyelids, resulting in increased NITBUT and TFLLT in subjects without meibomian gland dysfunction that seem to be clinically significant. Future studies are required to determine clinical efficacy and evaluate safety after long-term therapy in meibomian gland dysfunction patients. Copyright © 2014 American Academy of Optometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Anormalidades do filme lacrimal de cães podem ser classificadas quanto ao seu aspecto quantitativo, qualitativo ou ambos, sendo comumente observada na prática cotidiana. Intercorrências na produção de um ou mais componentes do filme lacrimal ensejam distúrbios oculares em graus variados, denominados ceratoconjuntivite seca. Diversas são as causas da ceratoconjuntivite seca em cães, mas a maioria dos casos é de caráter idiopático, estando associada à participação de linfócitos T. O diagnóstico em medicina veterinária é firmado com base nos valores obtidos pelo teste da lacrimal de Schirmer. O presente artigo objetiva revisar os aspectos relacionados à etiopatogenia e ao diagnóstico da ceratoconjuntivite seca em cães, assim como discutir novas modalidades terapêuticas para a doença.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Meibomian-derived lipid secretions are well characterised but their subsequent fate in the ocular environment is less well understood. Phospholipids are thought to facilitate the interface between aqueous and lipid layers of the tear film and to be involved in ocular lubrication processes. We have extended our previous studies on phospholipid levels in the tear film to encompass the fate of polar and non-polar lipids in progressive accumulation and aging processes on both conventional and silicone-modified hydrogel lenses. This is an important aspect of the developing understanding of the role of lipids in the clinical performance of silicone hydrogels. Method: Several techniques were used to identify lipids in the tear film. Mass-spectrometric methods included Agilent 1100-based liquid chromatography coupled to mass spectrometry (LCMS) and Perkin Elmer gas chromatography mass spectrometry (GCMS). Thin layer chromatography (TLC) was used for separation of lipids on the basis of increasing solvent polarity. Routine assay of lipid extractions from patient-worn lenses was carried out using a Hewlett Packard 1090 liquid chromatograph coupled to both uv and Agilent 1100 fluorescence detection. A range of histological together with optical, and electron microscope techniques was used in deposit analysis. Results: Progressive lipid uptake was assessed in various ways, including: composition changes with wear time, differential lipid penetrate into the lens matrix and, particularly, the extent to which lipids become unextractable as a function of wear time. Solvent-based separation and HPLC gave consistent results indicating that the polarity of lipid classes decreased as follows: phospholipids/fatty acids > triglycerides > cholesterol/cholesteryl esters. Tear lipids were found to show autofluorescence—which underpinned the value of fluorescence microscopy and fluorescence detection coupled with HPLC separation. The most fluorescent lipids were found to be cholesteryl esters; histological techniques coupled with fluorescence microscopy indicated that white spots (’’jelly bumps’’) formed on silicone hydrogel lenses contain a high proportion of cholesteryl esters. Lipid profiles averaged for 30 symptomatic and 30 asymptomatic contact lens wearers were compiled. Peak classes were split into: cholesterol (C), cholesteryl esters (CE), glycerides (G), polar fatty acids/phospholipids (PL). The lipid ratio for ymptomatic/symptomatic was 0.6 ± 0.1 for all classes except one—the cholesterol ratio was 0.2 ± 0.05. Significantly the PL ratio was no different from that of any other class except cholesterol. Chromatography indicated that: lipid polarity decreased with depth of penetration and that lipid extractability decreased with wear time. Conclusions: Meibomian lipid composition differs from that in the tear film and on worn lenses. Although the same broad lipid classes were obtained by extraction from all lenses and all patients studied, quantities vary with wear and material. Lipid extractability diminishes with wear time regardless of the use of cleaning regimes. Dry eye symptoms in contact lens wear are frequently linked to lipid layer behaviour but seem to relate more to total lipid than to specific composition. Understanding the detail of lipid related processes is an important element of improving the clinical performance of materials and care solutions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Surfactant proteins A, B, C and D complex with (phospho)lipids to produce surfactants which provide low interfacial tensions. It is likely that similar complexation occurs in the tear film and contributes to its low surface tension. Synthetic protein-phospholipid complexes, with styrene maleic anhydrides (SMAs) as the protein analogue, have been shown to have similarly low surface tensions. This study investigates the potential of modified SMAs and/or SMA-phospholipid complexes, which form under physiological conditions, to supplement natural tear film surfactants. Method: SMAs were modified to provide structural variants which can form complexes under varying conditions. Infrared spectroscopy and Nuclear Magnetic Resonance were used to confirm SMA structure. Interfacial behaviour of the SMA and SMA-phospholipid complexes was studied using Langmuir trough, du Nûoy ring and pulsating bubblemethods. Factors which affect SMA-phospholipid complex formation, such as temperature and pH, were also investigated. Results: Structural manipulation of SMAs allows control over complex formation, including under physiological conditions (e.g. partial SMAesterfication allowed complexation with dimyristoylphosphatidylcholine, at pH7). The low surface tensions of the SMAs (42mN/m for static (du Nûoy ring) and 34mN/m for dynamic (Langmuir) techniques) demonstrate their surface activity at the air-aqueous interface. SMA-phospholipid complexes provide even lower surface tensions (~2 mN/m), approaching that of lung surfactant, as measured by the pulsating bubblemethod. Conclusions: Design of the molecular architecture of SMAs allows control over their surfactant properties. These SMAs could be used as novel tear films supplements, either alone to complex with native tear film phospholipids or delivered as synthetic protein-phospholipid complexes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Contact lenses have become a popular method of vision correction for millions of people globally. As with all devices designed for use within the body, interactions occur between the implanted material and the surrounding biological fluid. A common complaint of lens wearers is that they often experience symptoms of dry eye whilst wearing lenses. This sensation is often heightened towards the end of the day. Through the course of this study, various analytical techniques have been utilised including one dimensional electrophoresis and Western Blotting to study the protein profiles of tear samples. By studying the tears of non-contact lens wearers, it was possible to analyse what could be considered normal, healthy, individuals. A clinical study was also undertaken which followed a population of individuals from the neophyte stage to one whereby they were accustomed lens wearers. Tears were monitored at regular intervals throughout the course of this study and worn contact lenses were also analysed for proteins that had been deposited both on and within the lens. Contact lenses disrupt the tear film in a physical manner by their very presence. They are also thought to cause the normal protein profile to deviate from what would be considered normal. The tear film deposits proteins and lipids onto and within the lens. The lens may therefore be depriving the tear film of certain necessary components. The ultimate aim of this thesis was to discover how, and to what extent, lenses affected tear proteins and if there were any proteins in the tear fluid that had the potential to be used as biochemical markers. Should this be achievable it may be possible to identify those individuals who were more likely to become intolerant lens wearers. This study followed the changes taking place to the tear film as an effect of wearing contact lenses. Twenty-eight patients wore two different types of silicone hydrogel lenses in both a daily wear and a continuous wear regime. The tear protein profiles of the lens-wearers were compared with a control group of non-lens wearing individuals. The considerable amount of data that was generated enabled the clearly observable changes to the four main tear proteins to be monitored.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Biochemical changes brought about by the influence of the contact lens on the tear film are conveniently split into two categories. Firstly, the lens can remove or reduce the levels of specific components in the tear film, and secondly, the lens can augment the tear film, by stimulating the influx of new components or increasing the level of existing components. The most obvious tear film components for study in this context are lipids, proteins, mucins and electrolytes. The interactions are affected by the properties of the lens, the characteristics of the individual wearer and the wear schedule. An additional complicating factor is the fact that the lens is many times thicker than the tear film and any immobilised tear components will be more extensively exposed to oxygen and UV radiation than is the case in the absence of a lens. It is arguably the lipoidal components that are most markedly affected by lens wear, since their immobilisation on the lens surface markedly increases their susceptibility to autoxidative degradation. The limited information that is available highlights the importance of subject specificity and suggests that lipid oxidation phenomena are potentially important in contributing to the 'end of day' discomfort of symptomatic contact lens patients. It is clear that tear lipids, although regarded as relatively inert for many years, are now seen as a reactive and potentially important family of compounds in the search for understanding of contact lens-induced discomfort. The influence of the lens on tear proteins shows the greatest range of complexity. Deposition and denaturation can stimulate immune response, lower molecular weight proteins can be extensively absorbed into the lens matrix and the lens can stimulate cascade or upregulation processes leading either to the generation of additional proteins and peptides or an increase in concentration of existing components. Added to this is the stimulating influence of the lens on vascular leakage leading to the influx of plasma proteins such as albumin. The evidence from studies of mucin expression in tears is not consistent and conclusive. This is in part because sample sources, lens materials and methods of analysis vary considerably, and in some cases the study population numbers are low. Expression levels show mucin and material specificity but clear patterns of behaviour are elusive. The electrolyte composition of tears is significantly different from that of other body fluids. Sodium and potassium dominate but potassium ion concentrations in tears are much higher than in serum levels. Calcium and magnesium concentrations in tears are lower than in serum but closer to interstitial fluids. The contact lens provides the potential for increased osmolarity through enhanced evaporation and differential electrolyte concentrations between the anterior and posterior tear films. Since the changes in ocular biochemistry consequent upon contact lens wear are known to be subject-dependent - as indeed is wearer response to the lens - pre-characterisation of individual participant tear chemistry in clinical studies would enhance understanding of these complex effects. © 2013 Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. The purpose of this study was to evaluate the longitudinal changes in ocular physiology, tear film characteristics, and symptomatology experienced by neophyte silicone hydrogel (SiH) contact lens wearers in a daily-wear compared with a continuous-wear modality and with the different commercially available lenses over an 18-month period. Methods. Forty-five neophyte subjects were enrolled in the study and randomly assigned to wear one of two SiH materials: lotrafilcon A or balafilcon A lenses on either a daily- (LDW; BDW) or continuous-wear (LCW; BCW) basis. Additionally, a group of noncontact lens-wearing subjects (control group) was also recruited and followed over the same study period. Objective and subjective grading of ocular physiology were carried out together with tear meniscus height (TMH) and noninvasive tear breakup time (NITBUT). Subjects also subjectively rated symptoms and judgments with lens wear. After initial screening, subsequent measurements were taken after 1, 3, 6, 12, and 18 months. Results. Subjective and objective grading of ocular physiology revealed a small increase in bulbar, limbal, and palpebral hyperemia as well as corneal staining over time with both lens materials and regimes of wear (p < 0.05). No significant changes in NITBUT or TMH were found (p > 0.05). Subjective symptoms and judgment were not material- or modality-specific. Conclusions. Daily and continuous wear of SiH contact lenses induced small but statistically significant changes in ocular physiology and symptomatology. Clinical measures of tear film characteristics were unaffected by lens wear. Both materials and regimes of wear showed similar clinical performance. Long-term SiH contact lens wear is shown to be a successful option for patients. Copyright © 2006 American Academy of Optometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To compare graticule and image capture assessment of the lower tear film meniscus height (TMH). Methods: Lower tear film meniscus height measures were taken in the right eyes of 55 healthy subjects at two study visits separated by 6 months. Two images of the TMH were captured in each subject with a digital camera attached to a slit-lamp biomicroscope and stored in a computer for future analysis. Using the best of two images, the TMH was quantified by manually drawing a line across the tear meniscus profile, following which the TMH was measured in pixels and converted into millimetres, where one pixel corresponded to 0.0018 mm. Additionally, graticule measures were carried out by direct observation using a calibrated graticule inserted into the same slit-lamp eyepiece. The graticule was calibrated so that actual readings, in 0.03 mm increments, could be made with a 40× ocular. Results: Smaller values of TMH were found in this study compared to previous studies. TMH, as measured with the image capture technique (0.13 ± 0.04 mm), was significantly greater (by approximately 0.01 ± 0.05 mm, p = 0.03) than that measured with the graticule technique (0.12 ± 0.05 mm). No bias was found across the range sampled. Repeatability of the TMH measurements taken at two study visits showed that graticule measures were significantly different (0.02 ± 0.05 mm, p = 0.01) and highly correlated (r = 0.52, p < 0.0001), whereas image capture measures were similar (0.01 ± 0.03 mm, p = 0.16), and also highly correlated (r = 0.56, p < 0.0001). Conclusions: Although graticule and image analysis techniques showed similar mean values for TMH, the image capture technique was more repeatable than the graticule technique and this can be attributed to the higher measurement resolution of the image capture (i.e. 0.0018 mm) compared to the graticule technique (i.e. 0.03 mm). © 2006 British Contact Lens Association.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ultimate aim of this project was to design new biomaterials which will improve the efficiency of ocular drug delivery systems. Initially, it was necessary to review the information available on the nature of the tear fluid and its relationship with the eye. An extensive survey of the relevant literature was made. There is a common belief in the literature that the ocular glycoprotein, mucin, plays an important role in tear film stability, and furthermore, that it exists as an adherent layer covering the corneal surface. If this belief is true, the muco-corneal interaction provides the ideal basis for the development of sustained release drug delivery. Preliminary investigations were made to assess the ability of mucin to adhere to polymer surfaces. The intention was to develop a synthetic model which would mimic the supposed corneal/mucin interaction. Analytical procedures included the use of microscopy (phase contrast and fluorescence), fluorophotometry, and mucin-staining dyes. Additionally, the physical properties of tears and tear models were assessed under conditions mimicking those of the preocular environment, using rheological and tensiometric techniques. The wetting abilities of these tear models and opthalmic formulations were also investigated. Tissue culture techniques were employed to enable the surface properties of the corneal surface to be studied by means of cultured corneal cells. The results of these investigations enabled the calculation of interfacial and surface characteristics of tears, tear models, and the corneal surface. Over all, this work cast doubt on the accepted relationship of mucin with the cornea. A corneal surface model was designed, on the basis of the information obtained during this project, which would possess similar surface chemical properties (i.e. would be biomimetic) to the more complex original. This model, together with the information gained on the properties of tears and solutions intended for ocular instillation, could be valuable in the design of drug formulations with enhanced ocular retention times. Furthermore, the model itself may form the basis for the design of an effective drug-carrier.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A sizeable amount of the testing in eye care, requires either the identification of targets such as letters to assess functional vision, or the subjective evaluation of imagery by an examiner. Computers can render a variety of different targets on their monitors and can be used to store and analyse ophthalmic images. However, existing computing hardware tends to be large, screen resolutions are often too low, and objective assessments of ophthalmic images unreliable. Recent advances in mobile computing hardware and computer-vision systems can be used to enhance clinical testing in optometry. High resolution touch screens embedded in mobile devices, can render targets at a wide variety of distances and can be used to record and respond to patient responses, automating testing methods. This has opened up new opportunities in computerised near vision testing. Equally, new image processing techniques can be used to increase the validity and reliability of objective computer vision systems. Three novel apps for assessing reading speed, contrast sensitivity and amplitude of accommodation were created by the author to demonstrate the potential of mobile computing to enhance clinical measurement. The reading speed app could present sentences effectively, control illumination and automate the testing procedure for reading speed assessment. Meanwhile the contrast sensitivity app made use of a bit stealing technique and swept frequency target, to rapidly assess a patient’s full contrast sensitivity function at both near and far distances. Finally, customised electronic hardware was created and interfaced to an app on a smartphone device to allow free space amplitude of accommodation measurement. A new geometrical model of the tear film and a ray tracing simulation of a Placido disc topographer were produced to provide insights on the effect of tear film breakdown on ophthalmic images. Furthermore, a new computer vision system, that used a novel eye-lash segmentation technique, was created to demonstrate the potential of computer vision systems for the clinical assessment of tear stability. Studies undertaken by the author to assess the validity and repeatability of the novel apps, found that their repeatability was comparable to, or better, than existing clinical methods for reading speed and contrast sensitivity assessment. Furthermore, the apps offered reduced examination times in comparison to their paper based equivalents. The reading speed and amplitude of accommodation apps correlated highly with existing methods of assessment supporting their validity. Their still remains questions over the validity of using a swept frequency sine-wave target to assess patient’s contrast sensitivity functions as no clinical test provides the range of spatial frequencies and contrasts, nor equivalent assessment at distance and near. A validation study of the new computer vision system found that the authors tear metric correlated better with existing subjective measures of tear film stability than those of a competing computer-vision system. However, repeatability was poor in comparison to the subjective measures due to eye lash interference. The new mobile apps, computer vision system, and studies outlined in this thesis provide further insight into the potential of applying mobile and image processing technology to enhance clinical testing by eye care professionals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dry eye disease is a common clinical condition whose aetiology and management challenges clinicians and researchers alike. Practitioners have a number of dry eye tests available to clinically assess dry eye disease, in order to treat their patients effectively and successfully. This thesis set out to determine the most relevant and successful key tests for dry eye disease diagnosis/ management. There has been very little research on determining the most effective treatment options for these patients; therefore a randomised controlled study was conducted in order to see how different artificial treatments perform compared to each other, whether the preferred treatment could have been predicted from their ocular clinical assessment, and if the preferred treatment subjectively related to the greatest improvement in ocular physiology and tear film stability. This research has found: 1. From the plethora of ocular the tear tests available to utilise in clinical practice, the tear stability tests as measured by the non-invasive tear break (NITBUT) up time and invasive tear break up time (NaFL TBUT) are strongly correlated. The tear volume tests are also related as measured by the phenol red thread (PRT) and tear meniscus height (TMH). Lid Parallel Conjunctival Folds (LIPCOF) and conjunctival staining are significantly correlated to one another. Symptomology and osmolarity were also found to be important tests in order to assess for dry eye. 2. Artificial tear supplements do work for ocular comfort, as well as the ocular surface as observed by conjunctival staining and the reduction LIPCOF. There is no strong evidence of one type of artificial tear supplement being more effective than others, and the data suggest that these improvements are more due to the time than the specific drops. 3. When trying to predict patient preference for artificial tears from baseline measurements, the individual category of artificial tear supplements appeared to have an improvement in at least 1 tear metric. Undoubtedly, from the study the patients preferred artificial tear supplements’ were rated much higher than the other three drops used in the study and their subjective responses were statistically significant than the signs. 4. Patients are also willing to pay for a community dry eye service in their area of £17. In conclusion, the dry eye tests conducted in the study correlate with one another and with the symptoms reported by the patient. Artificial tears do make a difference objectively as well as subjectively. There is no optimum artificial treatment for dry eye, however regular consistent use of artificial eye drops will improve the ocular surface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To assess the surface tear breakup time and clinical performance of three daily disposable silicone hydrogel contact lenses over 16 hours of wear. METHODS: Thirty-nine patients (mean [±SD] age, 22.1 [±3.5] years) bilaterally wore (narafilcon A, filcon II-3, and delefilcon A) contact lenses in a prospective, randomized, masked, 1-week crossover clinical trial. Tear film was assessed by the tear meniscus height (TMH), ocular/contact lens surface temperature dynamics, and lens surface noninvasive breakup time at 8, 12, and 16 hours of wear. Clinical performance and ocular physiology were assessed by subjective questionnaire, by high-/low-contrast logMAR (logarithm of the minimum angle of resolution) acuity, and through bulbar and limbal hyperemia grading. Corneal and conjunctival staining were assessed after lens removal. RESULTS: Delefilcon A demonstrated a longer noninvasive breakup time (13.4 [±4.4] seconds) than filcon II-3 (11.6 [±3.7] seconds; p < 0.001) and narafilcon A (12.3 [±3.7] seconds; p < 0.001). A greater TMH (0.35 [±0.11] mm) was shown by delefilcon A than filcon II-3 (0.32 [±0.10] seconds; p = 0.016). Delefilcon A showed less corneal staining after 16 hours of lens wear (0.7 [±0.6] Efron grade) than filcon II-3 (1.1 [±0.7]; p < 0.001) and narafilcon A (0.9 [±0.7]; p = 0.031). Time was not a significant factor for prelens tear film stability (F = 0.594, p = 0.555) or TMH (F = 0.632, p = 0.534). Lens brand did not affect temperature (F = 1.220, p = 0.308), but it decreased toward the end of the day (F = 19.497, p < 0.001). Comfort, quality of vision, visual acuity and contrast acuity, and limbal grading were similar between the lens brands but decreased with time during the day (p < 0.05). CONCLUSIONS: The tear breakup time over the contact lens surface differed between lens types and may have a role in protecting the ocular surface.