388 resultados para Tear
Resumo:
The tear film plays an important role in maintaining the integrity of the ocular suface. During general anesthesia, tear production is considerably reduced, which requires care to prevent adverse effects that result in diseases of these structures. Studies comparing the effects of induction of anaesthesia with thiopental and propofol on tear production have not been carried out yet. Because these drugs are used in veterinary medicine, we decided to evaluate the tear production in 30 dogs undergoing experimental surgery as well as routine procedures at the veterinary hospital of Federal University of Viçosa. Patients were divided into two groups of equal number. All animals were sedated with clorpromazine and maintained with isoflurane in diluted oxygen. Group 1 was induced with thiopental whereas group 2 with propofol. Schirmer tear test 1 was performed before sedation (T0), 15 minutes after sedation (T1) and 10 minutes after induction of anesthesia (T2) with the drug chosen for one of the groups. There was a significant decrease in tear production for both drugs, but no significant statistical differences were found between them. Thus, considering the results and the way in which the study was conducted, we suggest protecting the cornea and conjunctiva of patients during anesthesia using any of the drugs here evaluated.
Resumo:
Some ophthalmic surgeries require induction of mydriasis, however, drugs traditionally used for this purpose significantly reduces tear production. To evaluate the effect of acepromazine and tramadol, used alone or in combination, on pupil diameter, tear production, heart and respiratory rate, systolic blood pressure and rectal temperature, these drugs were administered to seven clinically normal dogs divided into three experimental groups (G1 - acepromazine; G2 - tramadol; G3 - tramadol + acepromazine) that differed only in the sedation protocol. Parameters were measured in four experimental moments. Miosis occurred in G1, in addition to reduced tear production and respiratory rate. No significant changes were found in the parameters assessed in G2, whereas in G3, there was decrease in tear production of the right eye, decrease in the respiratory rate and rectal temperature. Tramadol proved to be a drug suitable for pre-anesthetic procedures that require the maintenance of pupil diameter and keeps the tear production within normal parameters. However, the use of acepromazine alone or in combination with tramadol requires protection of the patient's eye surface to prevent the occurrence of undesirable ophthalmic changes.
Resumo:
Tomando como ponto de partida e de chegada a metáfora do “tear” utilizada por uma das supervisoras entrevistadas neste estudo descrevem-se estratégias e práticas de supervisão do ponto de vista das supervisoras e das respectivas supervisandas. Descrevem-se estratégias de “scaffolding” (colocar andaimes) numa perspectiva individual e sistémica, envolvendo todos os adultos em processos de aprendizagem para a melhoria da qualidade pedagógica. Estas estratégias são descritas usando a metáfora inicial do “tear”. Fornece-se suporte teórico para o uso destas metáforas.
Resumo:
Purpose: To determine the relationship of goblet cell density (GCD) with tear function and ocular surface physiology. Methods: This was a cross-sectional study conducted in 35 asymptomatic subjects with mean age 23.8±3.6 years. Tear film assessment, conjunctiva and cornea examination were done in each subject. Conjunctival impression cytology was performed by applying Nitrocellulose Millipore MFTM-Membrane filter over the superior bulbar conjunctiva. The filter paper was than fixed with 96% ethanol and stained with Periodic Acid Schiff, Hematoxylin and Eosin. GCD was determined by optical microscopy. Relation between GCD and Schirmer score, tear break-up time (TBUT), bulbar redness, limbal redness and corneal staining was determined. Results: The mean GCD was 151±122 cells/mm2. GCD was found higher in eyes with higher Schirmer score but it was not significant (p = 0.75). There was a significant relationship ofGCDwith TBUT (p = 0.042). GCD was not correlated with bulbar redness (p = 0.126), and limbal redness (p = 0.054) as well as corneal staining (p = 0.079). No relationship of GCD with age and gender of the subjects (p > 0.05) was observed. Conclusion: GCD was found correlated with TBUT but no significant correlation was found with the aqueous portion of the tear, limbal as well as bulbar redness and corneal staining.
Resumo:
INTRODUCTION AND HYPOTHESIS: This study aims to estimate fecal, urinary incontinence, and sexual function 6 years after an obstetrical anal sphincter tear. METHODS: Among 13,213 women who had a vaginal delivery of a cephalic singleton at term, 196 women sustained an anal sphincter tear. They were matched to 588 controls. Validated questionnaires grading fecal and urinary incontinence, and sexual dysfunction were completed by the participants. RESULTS: Severe fecal incontinence was more frequently reported by women who had sustained an anal sphincter tear compared to the controls. Women with an anal sphincter tear had no increased risk of urinary incontinence, but reported significantly more pain, difficulty with vaginal lubrication, and difficulty achieving orgasm compared to the controls. A fetal occiput posterior position during childbirth was an independent risk factor for both severe urinary incontinence and severe sexual dysfunction. CONCLUSIONS: Fecal incontinence is strongly associated with an anal sphincter tear. A fetal occiput posterior position represents a risk factor for urinary incontinence and sexual dysfunction.
Resumo:
Palmer previously proposed a classification system of triangular fibrocartilage complex (TFCC) injuries that proved to be useful in directing clinical management. However, dorsal peripheral tears (variants of class 1C) were not described and have rarely been reported in the literature since. We herewith present a rare case of bucket-handle tear of the TFCC. To our knowledge, this is the first case demonstrating partial separation of both the palmar and dorsal distal radioulnar ligaments (DRULs) from the articular disc. The particular wrist magnetic resonance (MR) arthrographic findings of this unusual complex peripheral TFCC tear (a variant of both class 1B and 1C) were nicely appreciated upon sagittal reformatted images.
Resumo:
OBJECTIVETo identify and analyse skin tear prevalence and factors associated with its occurrence.METHODSystematic review of literature of studies published until June 2014 including studies published in full in English, Spanish or Portuguese. The studies were analysed according to the Strengthening the Reporting of Observational Studies in Epidemiology and the Guidelines for Critically Appraising Studies of Prevalence or Incidence of a Health Problem.RESULTSThe analysis of eight studies showed skin tear prevalence of 3.3% to 22% in the hospital setting and 5.5% to 19.5% in homecare. Advanced age, dependence on basic activities of daily life, frail elderly, level of mobility, agitated behavior, non-responsiveness, greater risk for concurrent development of pressure ulcers, cognitive impairment, spasticity and photoaging were cited as risk factors.CONCLUSIONSkin tear prevalence ranged from 3.3% to 22% and is mainly associated with advanced age and dependence on basic activities of daily life.
Resumo:
Rotator cuff disease is the most common pathology causing shoulder pain with an overall prevalence rate of 30%. There is a significant association between increasing age and the presence of rotator cuff tears. Spontaneous healing of clinically relevant tears has not been observed. Although satisfactory pain relief is possible without rotator cuff tendon healing, functional outcome is better for healed repairs. Operative treatment must be considered in the context of the reasonable expectations for success. Repairability and potential of surgically tendon construct to heal are important considerations in surgical indications. There is no difference of outcomes between the arthroscopic and the open techniques.
Resumo:
Partial-thickness tears of the supraspinatus tendon frequently occur at its insertion on the greater tubercule of the humerus, causing pain and reduced strength and range of motion. The goal of this work was to quantify the loss of loading capacity due to tendon tears at the insertion area. A finite element model of the supraspinatus tendon was developed using in vivo magnetic resonance images data. The tendon was represented by an anisotropic hyperelastic constitutive law identified with experimental measurements. A failure criterion was proposed and calibrated with experimental data. A partial-thickness tear was gradually increased, starting from the deep articular-sided fibres. For different values of tendon tear thickness, the tendon was mechanically loaded up to failure. The numerical model predicted a loss in loading capacity of the tendon as the tear thickness progressed. Tendon failure was more likely when the tendon tear exceeded 20%. The predictions of the model were consistent with experimental studies. Partial-thickness tears below 40% tear are sufficiently stable to persist physiotherapeutic exercises. Above 60% tear surgery should be considered to restore shoulder strength.
Resumo:
Abstract The present report describes a case where typical findings of traumatic glenohumeral interposition of rotator cuff stumps were surgically confirmed. This condition is a rare complication of shoulder trauma. Generally, it occurs in high-energy trauma, frequently in association with glenohumeral joint dislocation. Radiography demonstrated increased joint space, internal rotation of the humerus and coracoid process fracture. In addition to the mentioned findings, magnetic resonance imaging showed massive rotator cuff tear with interposition of the supraspinatus, infraspinatus and subscapularis stumps within the glenohumeral joint. Surgical treatment was performed confirming the injury and the rotator cuff stumps interposition. It is important that radiologists and orthopedic surgeons become familiar with this entity which, because of its rarity, might be neglected in cases of shoulder trauma.
Resumo:
Background: Intraocular pressure (IOP) is the pressure inside the eye that helps to maintain the integrity and the suitable form of the ocular globe. Precise and accurate measures of IOP are needed for the diagnosis as well as follow-up of glaucoma. In daily clinical practice, Goldmann applanation tonometer (GAT) and Non-contact tonometer (NCT) are the most common devices for measuring IOP. A close agreement between these methods has been showed, particularly in normotensive patients and a poor agreement, especially when IOP levels are above the normal range. Ophthalmologists have noticed a poor agreement between NCT and GAT, observing that by using NCT and after comparing with GAT, there is an overestimation of IOP readings, and particularly it occurs when the eyes are tearful. Previous studies investigate the effect of tears in Non-contact tonometer readings by the instillation of artificial tears, concluding in one of the studies that the variation was less than 1mmHg and not clinically significant, in contrast with another study which the increases were sadistically significant. Tear menisci are a thin strip of tear fluid located between the bulbar conjunctiva and the eyelid margins. We think that the overestimation of IOP readings using NCT could be due to the presence of a higher volume of tear in the lower tear meniscus which might cause an optical interference in the optoelectronic applanation monitoring system of this deviceObjectives: To research the influence of a certain volume of fluid in the lower tear meniscus on IOP measurements using the NCT in healthy eyes. Moreover, to investigate the agreement between IOP readings obtained by NCT and GAT in the presence and absence of this volume of fluidMethods: The study design will be transversal for diagnostic tests of repeated measures. We will study patients with no ocular pathology and IOP<21mmHg. It will consist in the measurement of IOP using NCT before and after the instillation of COLIRCUSÍ FLUOTEST, used as a volume of fluid in the lower tear meniscus, to observe if there will be differences using the paired t-test. Moreover, we will take IOP measures by GAT in order to know the agreement between these methods after and before the application of these eyedrops, using the ICC (intraclass correlation coefficient) and the Bland-Altmann method
Resumo:
This study aimed to compare the normal intraocular pressure (IOP) and tear secretion, by means of applanation tonometry and the Schirmer tear test-1 (STT-1), in goats of the Saanen breed with different ages, and at different time points. Thirty six goats, free of ocular abnormalities, were grouped into three different age categories (n=12), animals with 45, 180 and 549 days of age. STT-1 and IOP measurements were carried out always at 9:00am and 7:00pm, during three consecutive days. Results were evaluated statistically (P<0.05). Regarding the time of the day, overall IOP values were significantly lower at 7:00 pm (P<0.001) in individuals with 45 days of age; whereas STT-1 values were significantly higher at 7:00pm (P=0.004) in goats with 549 days of age. Considering the sum of three days, both parameters were significantly lower in individuals with 45 days of age (P<0.001). Intraocular pressure and tear secretion values increase until 180 days of age in the Saanen breed of goats.