970 resultados para Tc-99m-sestamibi


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the tumor response to neoadjuvant chemotherapy, Tc-99m-sestamibi breast scintigraphy was proposed as a quantitative method Fifty-five patients with ductal carcinoma were studied They underwent breast scintigraphy before and after neoadjuvant chemotherapy, along with clinical assessment and surgical specimen analysis The regions of interest on the lesion and contralateral breast were identified, and the pixel counts were used to evaluate lesion uptake in relation to background radiation The ratio of these counts before to after neoadjuvant chemotherapy was assessed The decrease in uptake rate due to chemotherapy characterized the scintigraphy tumor response The Kruskal-Wallis test was used to compare the mean scintigraphic tumor response and histological type Dunn's multiple comparison test was used to detect differences between histological types The Mann-Whitney test was used to compare means between quantitative and qualitative variables scintigraphic tumor response vs clinical response and uptake before chemotherapy vs scintigraphic tumor response The Spearman's test was used to correlate the quantitative variables of clinical reduction in tumor size and scintigraphic tumor response All of the variables compared presented significant differences The change in Tc-99m-sestamibi uptake noted on breast scintigraphy, before to after neoadjuvant chemotherapy, may be used as an effective method for evaluating the response to neoadjuvant chemotherapy, since this quantification reflects the biological behavior of the tumor towards the chemotherapy regimen Furthermore, additional analysis on the uptake rate before chemotherapy may accurately predict treatment response

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Scintimammography using Tc-99m-sestamibi is a noninvasive and painless diagnostic imaging method that is used to detect breast cancer when mammography is inconclusive Because of the advantages of labeling v '7,ith Tc-99m-sestamibi and its high efficiency in detecting carcinomas, it is the most widespread agent for this purpose Its accumulation in the tumor has multifactorial causes and does not depend on the presence of architectural distortion or local or diffuse density variation in the breast The objective of tfiis study was to evaluate the accuracy of scintimammography 1 for detecting breast cancer One hundred and fifty-seven patients presenting 158 palpable and non-palpable breast nodules were evaluated Three patients were male and 154 were female, aged between 14 and 81 years All patients underwent scintimammography, and the nodule was subjected i to cytological or histological study, i e, the gold standard for diagnosing cancer One hundred and eleven malignant and 47 benign nodules were detected, with predominance of ductal carcinomas (n=94) and fibroadenoma/fibrocysiic condition (n=11/n=11), respectively The mean size was 3 11 cm (7-10 cm) among the malignant nodules and 2 07 cm among the benign nodules (0 5-10 cm) The sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 89, 89, 95, 78 and 89%, respectively Analysis on the histological types showed that the technique was more effective on tumors that were more aggressive, such as ductal carcinoma In this study, Tc-99m-sestamibi scintim immography was shown to be an important tool for diagnosing breast cancer when mammography was inconclusive

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate changes in mammographic density and Tc-99m-sestamibi scintimammographic uptake in postmenopausal women on hormone replacement therapy (HRT).Methods: Seventy-five postmenopausal women were prospectively studied and allocated into three groups: 50 women were randomized to either Group 1 (G1, n = 25), which received 2 mg of 17 beta-oestradiol continuously combined with 1 mg of norethisterone acetate (E-2/NETA, Kliogest (R), Medley) or Group 2 (G2), which received 2.5 mg/day of tibolone (Livial (R), Organon). The remaining 25 women, who were asymptomatic and had no desire to undergo HRT, constituted the control group (G3). Each patient was submitted to both mammography and scintimammography at baseline and after six months. Mammographic density was evaluated by using the BI-RADS classification system. The classification system of Barros et al. was used in the interpretation of scintimammography. For statistical analysis, the Chi-square test, ANOVA and Pearson's correlation were used.Results: At six months, increased mammographic density was observed in 48% of G1, 12% of G2 and 16% of G3 patients (p < 0.001). The increase in sestamibi uptake was 56% in G1, 28% in G2 and 24% in G3 (p < 0.001). Increases in both density and uptake were significantly higher in the group on E-2/NETA than among tibolone users and the controls.Conclusion: In postmenopausal women, HRT with E-2/NETA was associated with increased mammographic density and increased Tc-99m-sestamibi scintimammographic uptakes, suggesting greater mithochondrial activity in the cells of the mammary duct. This was not observed in users of 2.5 mg of tibolone, demonstrating that the effects on the breast were reduced. The same was observed in the control group. (c) 2005 Elsevier B.V.. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A macroscopic quantity of quasi-spherical fullerene-like shells (see Figure) that encapsulate iron nanoparticles containing radioisotope Tc-99m are prepared for the first time. The nanocomposite is acid-non-leachable, retaining radioactivity at an extremely high level. This method will enable rigorous studies of what are currently theoretical descriptions of nanometer-scale medicinal delivery vehicles for diagnostic and therapeutic purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A cintilografia com radioisótopos em repouso tem despertado muito interesse nos últimos anos para pesquisa da viabilidade miocárdica na disfunção isquêmica avançada do VE, porque esta pode ser reversível e porque há melhora prognóstica neste contexto. O objetivo desse trabalho é buscar identificar a acurácia da cintilografia tomográfica Tc-99m-Sestamibi, sob a infusão de dobutamina em baixa dose. Foram protocolados trinta pacientes que sofreram um infarto do miocárdio com padrão “Q”, com dissinergia ao ecocardiograma, e submetidos a estudos perfusionais em dias diferentes, com Tc-99m-Sestamibi − dobutamina e Tl-201 em repouso-redistribuição 4 horas, usado como padrão ouro. Não ocorreram complicações com nenhum paciente submetido ao protocolo do estudo. Os resultados revelaram: sensibilidade = 85%, especificidade = 87%, valor preditivo positivo = 96%, valor preditivo negativo = 65 % e acurácia de = 85,2%. A razão de probabilidade positiva foi de 6,68 e a razão de probabilidade negativa de 0,17. Confrontando-se nossos dados com uma metanálise de resultados para o Tc-99m-Sestamibi em repouso, a sensibilidade no presente estudo foi 85% vs. 81% e a especificidade de 87% vs. 60%. Em relação aos dados da literatura para Tl-201: 85% vs. 90% e 87% vs. 54%, sensibilidade e especificidade, respectivamente. Em conclusão, o Tc-99m-Sestamibi sob a infusão de dobutamina parece ser um método promissor para detectar viabilidade superior a esta modalidade de cintilografia em repouso, com valores preditivos comparáveis à literatura disponível para esse mesmo método: 85,2% vs. 87%, 96% vs. 90% e 65% vs. 83%, para acurácia, valor preditivo positivo e valor preditivo negativo, respectivamente.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. The aim of this study was to investigate the feasibility of sentinel lymph node (SLN) identification using radioisotopic lymphatic mapping with technetium-99 m-labeled phytate in patients undergoing radical hysterectomy with pelvic lymphadenectomy for treatment of early cervical cancer.Methods. Between July 2001 and February 2003, 56 patients with cervical cancer 1160 stage I (it 53) or stage 11 (it 3) underwent sentinel lymph node detection with preoperative lymphoscintigraphy (Te-99m-labeled phytate injected into the uterine cervix, at 3, 6, 9, and 12 o'clock, at a dose of 55-74 MBq in a volume of 0.8 ml) and intratoperative lymphatic mapping with a handheld gamma probe, Radical hysterectomy was aborted in three cases because parametrial invasion was found intraoperatively and we performed only sentinel node resection. The remaining 53 patients underwent radical hysterectomy with complete pelvic lymphadenectomy, Sentinel nodes were detected using a handheld gamma-probe and removed for pathological assessment during the abdominal radical hysterectomy and pelvic lymphadenectomy.Results. One or more sentinel nodes were detected in 52 out of 56 eligible patients (92.8%). A total of 120 SLNs were detected by lymphoscintigraphy (mean 2.27 nodes per patient) and intraoperatively by gamma probe, Forty-four percent of SLNs were found in the external iliac area, 39% in the obturator region, 8.3% in interiliae region, and 6.7),) in the common iliac area. Unilateral sentinel nodes were found in thirty-one patients (59%). The remaining 21 patients (4100 had bilateral sentinel nodes, Microscopic nodal metastases were confirmed in 17 (32%) cases. In 10 of these patients, only SLNs had metastases. The 98 sentinel node.,, that were negative on hematoxylin and eosin were submitted to cytokeratin immunohistochemical analysis. Five (5.1%) micrometastases were identified with this technique. The sensitivity of the sentinel node was 82.3% (CI 95% - 56.6-96.2) and the negative predictive value was 92.1% (CI 95% 78.6 98.3) the accuracy of sentinel node in predicting the lymph node status was 94.2%,Conclusion. Preoperative lymphoscintigraphy and intraoperative lymphatic mapping with Tc-99-labeled phytate are effective in identifying sentinel nodes in patients undergoing radical hysterectomy and to select women in whom lymph node dissection call be avoided. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le caratteristiche del 99mTc e la possibilità per gli ospedali di produrlo in loco quotidianamente grazie ai generatori, hanno reso questo radioisotopo il più utilizzato della fisica medica: è richiesto in circa l’80% delle procedure di medicina nucleare con circa 7 milioni di somministrazioni all’anno in Europa e 8 milioni negli USA. Inoltre il campo di applicabilità del 99mTc è molto vasto: viene infatti utilizzato per scintigrafie ossee, epatiche, renali, celebrali, tiroidee e per il controllo della funzionalità epatica. A causa del notevole incremento dell’insorgenza di patologie oncologiche e dell’aumento della popolazione, la richiesta di 99mTc è sempre cresciuta negli anni ed è ancora destinata a crescere nei prossimi; l’unico fattore attenuante è lo sviluppo di altre tecniche di diagnostica funzionale come la PET ( Positron Emission Tomography ). Nonostante la creazione del 99mTc da generatori di 99Mo sia ancora oggi il metodo di produzione più efficiente, si sta ponendo recentemente la necessità di ricercare nuove tecniche di produzione dell’isotopo per soddisfare le grandi quantità richieste dal mercato globale. Questo accade perché malgrado l’utilizzo del 99mTc sia in forte crescita, la produzione di 99Mo è destinata a diminuire in quanto necessita di reattori nucleari: gli ingenti costi delle moderne centrali e le elevate quantità di scorie prodotte, stanno guidando la politica mondiale verso una denuclearizzazione che renderà in pochi anni impossibile soddisfare la richiesta di 99Mo della medicina nucleare. Questo lavoro di tesi si colloca in questo contesto, cioè nella ricerca di un metodo alternativo per la produzione di 99mTc: l’irraggiamento con protoni di un target di 100Mo arricchito, in un ciclotrone ad uso medicale. L’obbiettivo che si vuole raggiungere è fornire una stima attendibile su tale produzione, valutare la qualità dell’isotopo e mettere in luce eventuali problematiche riscontrabili.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O 99mTc é o radionuclídeo mais utilizado em medicina nuclear. No Brasil os geradores de 99Mo/99mTc são produzidos exclusivamente pelo Centro de Radiofarmácia do IPEN-CNEN/SP, com 99Mo importado de diferentes fornecedores. O 99Mo (t1/2 = 66 h), por ser um produto de fissão do 235U, pode conter impurezas radionuclídicas prejudiciais à saúde humana. Dessa forma, para que o gerador seja utilizado de forma segura, é necessário que o 99Mo seja avaliado por ensaios de controle de qualidade e atenda à alguma especificação descrita em farmacopeia. A Farmacopeia Europeia (FE) apresenta monografia, com parâmetros (identificação, pureza radioquímica e pureza radionuclídica), métodos de análise, e limites, para avaliação da qualidade da solução de [99Mo] na forma de molibdato de sódio, que é utilizada como matéria-prima no preparo dos geradores de 99Mo/99mTc. No entanto, observa-se uma dificuldade na implementação e execução dos métodos por parte dos produtores de geradores, com pouca literatura sobre o assunto, provavelmente devido à falta de praticidade dos métodos propostos e à extensa lista de reagentes utilizados. Nesse trabalho foram avaliados vários parâmetros de qualidade do 99Mo descritos na monografia da FE. Foram estudados métodos de separação do 99Mo de suas impurezas radionuclídicas por extração em fase sólida (SPE) e por TLC. Após separação por SPE, foi proposta a quantificação de metais por ICP-OES para avaliar a porcentagem de retenção de Mo e a porcentagem de recuperação de Ru e Te e Sr em diversos tipos de cartuchos, em substituição ao uso de radiotraçadores. Observou-se que a marca de cartucho de SPE para separação do 99Mo recomendada pela FE apresentou baixa recuperação para Ru, quando comparado aos outros cartuchos de troca aniônica disponíveis no mercado. Amostras de 99Mo de diferentes fornecedores mundiais foram analisadas. Observou-se que é possível realizar a quantificação de 103Ru em amostras de 99Mo mesmo com tempos de decaimento acima de 4 semanas. Um método alternativo de separação do 99Mo do 131I por TLC apresentou resultados promissores. Não foi feita a quantificação das impurezas radionuclídicas emissoras beta e alfa. Todas as amostras analisadas apresentaram resultados dentro das especificações da FE para pureza radioquímica (>95%) e pureza radionuclídica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação (Mestrado em Tecnologia Nuclear)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A osteodistrofia renal é uma complicação comum da insuficiência renal crônica. A biópsia óssea continua sendo o melhor método para o diagnóstico das doenças ósseas metabólicas. O objetivo deste estudo foi avaliar a utilidade da ultra-sonografia e da cintilografia com Tc-99m-sestamibi da paratireóide, como métodos diagnósticos não invasivos em pacientes com osteodistrofia renal em hemodiálise. Foram investigados 30 pacientes com insuficiência renal crônica, em tratamento com hemodiálise por no mínimo 6 meses, com sintomas e/ou com alterações bioquímicas sugestivas de doença óssea renal, sendo 19 mulheres e 11 homens, com média de idade de 43,9  9,17 anos. Quinze pacientes (50%) apresentaram diagnóstico de hiperparatireoidismo secundário, 5 (16,7%) de doença óssea mista, 3 (10%) de osteomalácia e 3 (10%) de doença óssea adinâmica. Glândulas aumentadas da paratireóide foram observadas em 12 (40%) pacientes na ultra-sonografia e em 15 (50%) na cintilografia com Tc-99m-sestamibi. O grupo de pacientes com glândulas aumentadas da paratireóide na ultra-sonografia, comparado com o grupo com glândulas não detectadas, apresentaram níveis séricos de PTHi aumentados (1536,6  881,8 x 811,7  705,5 pg/ml, p<0,05) e níveis séricos de albumina menores (3,690,24 x 4,030,44 g/dl, p<0,05). Todos os pacientes com níveis séricos de PTHi inferiores a 280 pg/ml apresentaram ecografias da paratireóide com resultados normais. Nove de 12 pacientes (83,3%), com ultra-sonografia com glândulas aumentadas da paratireóide, apresentavam níveis de PTHi superiores a 720 pg/ml. Ultra-sonografia mostrando glândulas aumentadas da paratireóide apresentou uma sensibilidade de 50%, uma especificidade de 66% e um valor preditivo positivo de 83% para o diagnóstico de doenças de alto remanejamento ósseo. Em relação aos resultados das cintilografias de paratireóide com Tc-99m-sestamibi, não houve diferenças nas médias dos níveis de PTHi entre os pacientes com ou sem glândulas aumentadas da paratireóide, assim como para os outros exames bioquímicos. Quando comparado aos níveis de PTHi, 2 pacientes apresentaram resultados positivos na cintilografia com PTHi inferior a 280 pg/ml e 8 (53,4%) acima de 720 pg/ml. Semelhante aos resultados das ultra-sonografias, a sensibilidade, a especificidade e o valor preditivo positivo da cintilografia para o diagnóstico das doenças de alto remodelamento ósseo foram baixos, 50%, 33% e 71%, respectivamente. Podemos concluir que a ultra-sonografia e a cintilografia com Tc-99m-sestamibi da paratireóide não foram bons métodos para o diagnóstico de doenças ósseas com alto remodelamento, no entanto, a ultra-sonografia da paratireóide foi superior a cintilografia com Tc-99m-sestamibi na detecção de glândulas aumentadas, sugerindo ser um marcador mais útil de gravidade em pacientes sintomáticos com hiperparatireoidismo secundário severo.