998 resultados para Tank system


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Polyculture of seaweeds alongside fed animal aquaculture is an environmentally friendly means of avoiding eutrophication problem both in land-based and sea-based monoculture systems. Many aspects of such polyculture systems have been described, but little attention has been given to the impact of live seaweeds on the microbiological properties of the water that connects the algae and animals. In this investigation, the Pacific red alga Gracilaria textorii was cultured in a recirculated dual tank system (150 L) with the juvenile abalone Haliotis discus hannai. Dynamic changes of total bacteria (TB) and total Vibrio (TV) in the water of polyculture and monoculture systems were evaluated. Results revealed that (1) level of TB in the polyculture was constantly higher than in the monoculture over a 6.5-day period. While levels of TV in the polyculture was detected to be constantly lower than in the monoculture, (2) integration of G. textorii in the abalone culture changed the Vibrio compositions in the water as judged by the changes of bacteria colony types; (3) application of artificial diet led to dramatic increase of the levels in TB and TV in both systems at 12 h after application in the 24-h test and resulted in selective propagation of Vibrio in the water in the monoculture system; (4) polyculture of G. textorii with juvenile abalone in combination with feeding with live algal diet helped to maintain low levels of TV and the balance of the Vibrio composition; (5) living biomass of G. textorii was effective in preventing propagation of two purified Vibrio strains (V alginolaticus and V logei) in the water. These results provide a general basis of the dynamic changes of levels in TB and TV in a seaweed-abalone polyculture system with or without artificial diet in tanks. (c) 2005 Elsevier B.V All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Appropriate pipe insulation on domestic, pumped storage (split), solar water heating systems forms an integral part of energy conservation measures of well engineered systems. However, its importance over the life of the system is often overlooked. This study outlines the findings of computer modelling to quantify the energy and cost savings by using pipe insulation between the collector and storage tank. System sizes of 270 Litre storage tank, together with either selectively surfaced, flat plate collectors (4m2 area), or 30 evacuated tube collectors, were used. Insulation thicknesses of 13mm and 15mm, pipe runs both ways of 10, 15 and 20 metres and both electric and gas boosting of systems were all considered. The TRNSYS program was used to model the system performance at a representative city in each of the 6 climate zones for Australia and New Zealand, according to AS/NZS4234 – Heat Water Systems – Calculation of energy consumption and the ORER RECs calculation method. The results show:  Energy savings from pipe insulation are very significant, even in mild climates such as Rockhampton. Across all climates zones, savings ranged from 0.16 to 3.5GJ per system per year, or about 2 to 23 percent of the annual load.  There is very little advantage in increasing the insulation thickness from 13 to 15mm. For electricity at 19c/kWh and gas at 2 c/MJ, cost savings of between $27 and $100 per year are achieved across the climate zones. Both energy and cost savings would increase in colder climates with increased system size, solar contribution and water temperatures.  The pipe insulation substantially improves the solar contribution (or fraction) and Renewable Energy Certificates (RECs), as well as giving small savings in circulating pump running costs in milder climates. Solar contribution increased by up to 23 percent points and RECs by over 7 in some cases.  The study highlights the need to install and maintain the integrity of appropriate pipe insulation on solar water heaters over their life time in Australia and New Zealand.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To experimentally investigate the effect of vertical artificial substrate and different densities of the banana prawn Penaeus (Fenneropenaeus) merguiensis on nutrient levels in prawn pond effluent, a time series experiment was conducted in a replicated tank system supplied periodically with discharge from a prawn production pond. Few differences (P>0.05) were detected between tanks without prawns, and tanks with low densities (5 prawns in 1700 litres) of prawns (10-12 g), in terms of nitrogen and phosphorus in the water column over the 28-day experimental period. Higher densities of prawns (starting at 25 or 50 per tank) caused an elevation of these macronutrients in the water column. This was partly due to prawn biomass losses from mortalities and weight reductions in the tank system. The survival and condition of prawns was significantly (P<0.05) reduced in tanks at these higher densities. The presence of artificial substrate (2 m2 tank-1) did not affect (P>0.05) the levels of nutrients in tank water columns, but significantly (P<0.05) increased the amount of nitrogen in tank residues left at the end of the trial when no prawns were present. The prawns had obviously been grazing on surfaces inside the tanks, and their swimming actions appeared to keep light particulate matter in suspension. Higher prawn densities increased microalgal blooms, which presumably kept ammonia levels low, and it is suggested that this association may provide the means for improved remediation of prawn farm effluent in the future.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A central composite rotatable experimental design was constructed for a statistical study of the ethylation of benzene in the liquid phase, with aluminum chloride catalyst, in an agitated tank system. The conversion of benzene and ethylene and the yield of monoethyl- and diethylbenzene are characterized by the response surface technique. In the experimental range studied, agitation rate has no significant effect. Catalyst concentration, rate of ethylene Flow, and temperature are the influential factors. The response surfaces may be adequately approximated by planes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Much of the Bangalore sewage is treated in three streams namely Bellandur (K&C Valley),Vrishabhavati and Hebbal-Nagavara stream systems. Among these it is estimated that out of a total of about 500MLD of partially treated sewage is let into the Bellandur tank. We estimate that a total of about 77t N non-industrial anthropogenic nitrogen efflux (mainly urine and excreta) in Bangalore city. This is distributed between that handled by the three sewage streams, soak-pits and land deposition. About 17-24.5t N enters the Bellandur tank daily. This has been happening over few decades and our observations suggest that this approximately 380ha tank is functioning as a C and N removal system with reasonable efficiency. The ammoniacal and nitrate nitrogen content of the water at the discharge points were estimated and found that over 80% of the nitrogen influx and over 75% of the C influx is removed by this tank system. We observed that there are three nitrogen sinks namely bacterial, micro-algal and macrophytes. The micro-algal fraction is dominated by Microcystis and Euglenophyceae members and they appear to constitute a significant fraction. Water hyacinth represents the single largest representative of the macrophytes. This tank has been functioning in this manner for over three decades. We attempt to study this phenomenon from a material balance approach and show that it is functioning with a reasonable degree of satisfaction as a natural wetland. As the population served and concomitant influx into this wetland increases, there is a potential for the system to be overloaded and to collapse. Therefore a better understanding of its function and the need for maintenance is discussed in the paper.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes the trials made with a simple portable canvas-tarpaulin tank system developed at the University Sains Malaysia for culture of hybrid catfish (Clarias gariepinus x Clarias macrocephalus) by Malaysia small scale farmers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The authors compare the performance of two types of controllers one based on the multilayered network and the other based on the single layered CMAC network (cerebellar model articulator controller). The neurons (information processing units) in the multi-layered network use Gaussian activation functions. The control scheme which is considered is a predictive control algorithm, along the lines used by Willis et al. (1991), Kambhampati and Warwick (1991). The process selected as a test bed is a continuous stirred tank reactor. The reaction taking place is an irreversible exothermic reaction in a constant volume reactor cooled by a single coolant stream. This reactor is a simplified version of the first tank in the two tank system given by Henson and Seborg (1989).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The majority of on-site sewage management systems in Australia fail to perform to expectations. About 60% to 80% of on-site systems reportedly fail to produce acceptable effluent quality, and there is an increaed concern about the risks associated with public health and environmental pollution. In Victoria, a large proportion of septic tank installations have been reported to discharge highly polluted waste to drains and streams. Users, often considered by regulators as operators, have to bear the costs of upgrade/replacement of their old systems to meet stringent water quality guidelines. Some of the common problems include clogging of the disposal fields due to solids and organic overloading and surfacing of highly polluted effluent. Large land application area is subsequently required for irrigating the effluent and/or installation of upgraded disposal fields.
This paper investigates the effectiveness of various types of textile and plastic media, in polishing primary tank effluent, downstream from a typical two-compartment septic tank system. Results to date show that high biochemical oxygen demand removal rates are achieved from the textile and plastic media (up to 86% and 83% respectively). At these removal levels, the performance of a combined conventional septic tank system and plastic/textile filters is comparable to that of an advanced aerated wastewater treatment system. This approach, subject to further investigation, could provide a less costly upgrade.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Currently the uncertain system has attracted much academic community from the standpoint of scientific research and also practical applications. A series of mathematical approaches emerge in order to troubleshoot the uncertainties of real physical systems. In this context, the work presented here focuses on the application of control theory in a nonlinear dynamical system with parametric variations in order and robustness. We used as the practical application of this work, a system of tanks Quanser associates, in a configuration, whose mathematical model is represented by a second order system with input and output (SISO). The control system is performed by PID controllers, designed by various techniques, aiming to achieve robust performance and stability when subjected to parameter variations. Other controllers are designed with the intention of comparing the performance and robust stability of such systems. The results are obtained and compared from simulations in Matlab-simulink.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In a real process, all used resources, whether physical or developed in software, are subject to interruptions or operational commitments. However, in situations in which operate critical systems, any kind of problem may bring big consequences. Knowing this, this paper aims to develop a system capable to detect the presence and indicate the types of failures that may occur in a process. For implementing and testing the proposed methodology, a coupled tank system was used as a study model case. The system should be developed to generate a set of signals that notify the process operator and that may be post-processed, enabling changes in control strategy or control parameters. Due to the damage risks involved with sensors, actuators and amplifiers of the real plant, the data set of the faults will be computationally generated and the results collected from numerical simulations of the process model. The system will be composed by structures with Artificial Neural Networks, trained in offline mode using Matlab®

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Currently the uncertain system has attracted much academic community from the standpoint of scientific research and also practical applications. A series of mathematical approaches emerge in order to troubleshoot the uncertainties of real physical systems. In this context, the work presented here focuses on the application of control theory in a nonlinear dynamical system with parametric variations in order and robustness. We used as the practical application of this work, a system of tanks Quanser associates, in a configuration, whose mathematical model is represented by a second order system with input and output (SISO). The control system is performed by PID controllers, designed by various techniques, aiming to achieve robust performance and stability when subjected to parameter variations. Other controllers are designed with the intention of comparing the performance and robust stability of such systems. The results are obtained and compared from simulations in Matlab-simulink.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An experiment was carried out with 1 0 days old Clarias gariepinus fry over a period of 42 days to determine the effects of different feeds on growth and survival of African catfish fry in glass tanks. The experiment was designed into four treatments each having three replications. Thus treatment 1 (T1) was named as Tank Tubifex (TT) and treatment 2 (T2) as Tank Sabinco (TS), treatment 3 as Pond Tubifex (PT), and treatment 4 (T4) as Pond Sabinco (PS). Live Tubifex (protein levels 64.48%) was supplied to treatments 1 and 3 and rest of the treatments were supplied Sabinco starter-1 (protein levels 40.13%). The highest and the lowest growth in total length and weight were 12.90cm, 18.77g and 6.17cm, 4.04g recorded from the treatments 3 and 2, respectively. Growth of catfish fry under treatment 3 in terms of both length and weight were significantly higher (P<0.01) than those of the other treatments. However treatment 2 showed the significantly lowest (P<0.01) growth performance among the various treatments. The highest survival rate (92%) was also obtained with treatment 3. Tubifex proved to be the best larval feed in respect of growth and survival rate.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

More than eighteen percent of the world’s population lives without reliable access to clean water, forced to walk long distances to get small amounts of contaminated surface water. Carrying heavy loads of water long distances and ingesting contaminated water can lead to long-term health problems and even death. These problems affect the most vulnerable populations, women, children, and the elderly, more than anyone else. Water access is one of the most pressing issues in development today. Boajibu, a small village in Sierra Leone, where the author served in Peace Corps for two years, lacks access to clean water. Construction of a water distribution system was halted when a civil war broke out in 1992 and has not been continued since. The community currently relies on hand-dug and borehole wells that can become dirty during the dry season, which forces people to drink contaminated water or to travel a far distance to collect clean water. This report is intended to provide a design the system as it was meant to be built. The water system design was completed based on the taps present, interviews with local community leaders, local surveying, and points taken with a GPS. The design is a gravity-fed branched water system, supplied by a natural spring on a hill adjacent to Boajibu. The system’s source is a natural spring on a hill above Boajibu, but the flow rate of the spring is unknown. There has to be enough flow from the spring over a 24-hour period to meet the demands of the users on a daily basis, or what is called providing continuous flow. If the spring has less than this amount of flow, the system must provide intermittent flow, flow that is restricted to a few hours a day. A minimum flow rate of 2.1 liters per second was found to be necessary to provide continuous flow to the users of Boajibu. If this flow is not met, intermittent flow can be provided to the users. In order to aid the construction of a distribution system in the absence of someone with formal engineering training, a table was created detailing water storage tank sizing based on possible source flow rates. A builder can interpolate using the source flow rate found to get the tank size from the table. However, any flow rate below 2.1 liters per second cannot be used in the table. In this case, the builder should size the tank such that it can take in the water that will be supplied overnight, as all the water will be drained during the day because the users will demand more than the spring can supply through the night. In the developing world, there is often a problem collecting enough money to fund large infrastructure projects, such as a water distribution system. Often there is only enough money to add only one or two loops to a water distribution system. It is helpful to know where these one or two loops can be most effectively placed in the system. Various possible loops were designated for the Boajibu water distribution system and the Adaptive Greedy Heuristic Loop Addition Selection Algorithm (AGHLASA) was used to rank the effectiveness of the possible loops to construct. Loop 1 which was furthest upstream was selected because it benefitted the most people for the least cost. While loops which were further downstream were found to be less effective because they would benefit fewer people. Further studies should be conducted on the water use habits of the people of Boajibu to more accurately predict the demands that will be placed on the system. Further population surveying should also be conducted to predict population change over time so that the appropriate capacity can be built into the system to accommodate future growth. The flow at the spring should be measured using a V-notch weir and the system adjusted accordingly. Future studies can be completed adjusting the loop ranking method so that two users who may be using the water system for different lengths of time are not counted the same and vulnerable users are weighted more heavily than more robust users.