330 resultados para TRANSVAGINAL SONOGRAPHY


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To evaluate the accuracy of preoperative magnetic resonance imaging (MRI) findings relative to surgical presence of deeply infiltrating endometriosis (DIE). Methods: This prospective study included 92 women with clinical suspicion of DIE. The MR images were compared with laparoscopy and pathology findings. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of MRI for diagnosis of DIE were assessed. Results: DIE was confirmed at histopathology in 77 of the 92 patients (83.7%). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of MRI to diagnose DIE at each of the specific sites evaluated were as follows: retrocervical space (89.4%, 92.3%, 96.7%, 77.4%, 90.2%); rectosigmoid (86.0%, 92.9%, 93.5%, 84.8%, 89.1%); bladder (23.1%, 100%,100%, 88.8%, 89.1%); ureters (50.0%, 100%, 95.5%, 95.7%); and vagina (72.7%, 100%, 100%, 96.4%, 96.7%). Conclusion: MRI demonstrates high accuracy in diagnosing DIE in the retrocervical region, rectosigmoid. bladder, ureters, and vagina. (C) 2009 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Lid. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective Predictive factors of damage to the Fallopian tube may guide the treatment of Patients with tubal pregnancy. The aim of the present study was to investigate the association between the depth of trophoblastic invasion into the tubal wall, assessed on postoperative histological examination, with the findings obtained on transvaginal sonograpby (TVS) in women with ampullary Methods Women with ampullary pregnancy undergoing salpingectomy were enrolled into the study. Only women with a finding of either an embryo with cardiac activity or a tubal ring on TVS were included in the analysis, a total of 8.5 patients. Trophoblastic invasion was assessed postoperatively and was histologically classified as Stage I when limited to the tubal mucosa, Stage II when extending to the muscle layer and Stage III in the case of complete tubal wall infiltration. The association between findings on TVS and the stage of trophoblastic invasion was evaluated. Results There was a significant association between the findings on TVS and the depth of trophoblastic invasion (P < 0.001). All patients in whom an embryo with cardiac activity bad been identified were found to have Stage II (17.9%) or Stage III (82.1%) invasion, whereas in those patients who showed a tubal ring on TVS, Stage I invasion was the most frequent finding (41.3%). Conclusions In ampullary pregnancy, the finding on TVS of an embryo with cardiac activity is associated with deeper penetration of trophoblastic tissue into the tubal wall than is the finding of a tubal ring. Copyright (C) 2009 ISUOG, Published by John Wiley & Sons, Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Preterm delivery is the main cause of neonatal death and ultrasonographic cervical assessment has been shown to be more accurate than digital examination in recognizing a short cervix. This is a cross-sectional study, involving 1131 women at 22-24 weeks of pregnancy, designed to determine the distribution of cervical length and to examine which variables of demographic characteristics and obstetric history increase the risk of a short cervix (15 mm or less). The distribution of maternal demographic and obstetric history characteristics among patients with cervical length £15 mm was analyzed and compared to the findings for the general population. Risk ratios (RR) between subgroups were generated from this comparison. Median cervical length was 37 mm and in 1.5% of cases it was 15 mm or less. The proportion of women with a short cervix (<=15 mm) was significantly higher among patients with a low body mass index (RR = 3.5) and in those with previous fetal losses between 16-23 weeks (RR = 33.1) or spontaneous preterm deliveries between 24-32 weeks (RR = 14.1). We suggest that transvaginal sonographic measurement of cervical length be performed as part of a routine midtrimester ultrasound evaluation. There are specific variables of demographic characteristics and obstetric history which increase the risk of detecting a short cervix at 22-24 weeks.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUÇÃO. Mulheres pós-menopáusicas apresentam maior risco de desenvolvimento de doença arterial coronariana. Estudos observacionais demonstraram que a terapia de reposição hormonal produz efeitos benéficos no perfil lipídico e na modulação autonômica cardíaca. O aumento da variabilidade da freqüência cardíaca (VFC), até então atribuído à reposição hormonal, não foi testado em estudos randomizados, placebo-controlados, delineados para permitir a comparação entre as duas formas mais utilizadas de reposição hormonal. A VFC de 24 horas calculada pelo método não linear Mapa de Retorno Tridimensional permite avaliar tanto a modulação vagal como a simpática. OBJETIVOS Avaliar a modulação autonômica cardíaca de mulheres pósmenopáusicas através da análise da VFC no domínio do tempo e dos índices do Mapa de Retorno Tridimensional no ECG de 24 horas. Testar a hipótese de que a reposição hormonal contínua, seja com estradiol isolado (TRE), seja com estradiol associado à noretisterona (TRH), por um período de três meses, aumenta a VFC nessas mulheres. MÉTODOS Quarenta mulheres pós-menopáusicas (46 a 63 anos; média = 54,6 ± 4,2) foram randomizadas para um dos três tratamentos, de forma contínua: TRH, estrogenioterapia (TRE) ou placebo, por três meses consecutivos. Previamente, todas as mulheres foram submetidas a exames clínico, ginecológico e laboratorial (glicose, estradiol, HDL, LDL, triglicerídios; mamografia e ultrassonografia transvaginal). O ECG de 24 horas foi gravado em cada paciente, antes e após o tratamento, para calcular os índices da VFC. RESULTADOS Não houve diferença estatisticamente significativa entre os três grupos, após 3 meses de tratamento, nos índices da VFC e do Mapa de Retorno Tridimensional. A TRH diferiu da TRE apenas quanto ao perfil lipídico. A associação com a noretisterona provocou uma redução de 12,4 % no HDL (p = 0,008). CONCLUSÃO Em mulheres pós-menopáusicas, a terapia de reposição hormonal contínua com estradiol, ou com estradiol associado à noretisterona, por um período de 3 meses, não altera a modulação autonômica cardíaca avaliada pela VFC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sonohysterography was firstly described three decades ago. The saline solution infusion into the uterine cavity favors its use and provides excellent visualization of the anatomy and the inner cavity of the uterus better than the conventional transvaginal sonography To check the current role of sonohysterography in the uterine cavity assessment in women with abnormal uterine bleeding and asymptomatic, a literature review comparing sonohysterograph with conventional transvaginal sonography and/or ambulatory diagnostic hysteroscopy was carried out. To this end, relevant studies were researched in electronic databases Medline/PubMed, SciELO/LILACS. The sonohysterography is an ambulatory procedure, non-invasive, better cost-benefit, better sensitivity and specificity to identify uterine abnormalities, causing minimal discomfort and low complications rate. It was subject to revision which there is no more doubt about its accuracy. It can be concluded that the sonohysterography is a useful tool in the propedeutics to assess uterine cavity of symptomatic patients with abnormal uterine bleeding, infertility, recurrent miscarriages, and embryonic implantation failures in assisted reproduction treatment / in vitro fertilization and in any other intra and extra uterine cavity alteration. Hence, conventional transvaginal sonography is indicated as an initial method of assessment of the uterine cavity previously to ambulatory diagnostic hysteroscopy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Successful surgical treatment of deep bowel endometriosis depends on obtaining detailed information about the lesions, prior to the procedure. The objective of this study was to determine the capability of transvaginal ultrasonography with bowel preparation (TVUS-BP) to predict the presence of one or more rectosigmoid nodules and the deepest bowel layer affected by the disease. A prospective study of 194 patients with clinical and TVUS-BP suspected deep endometriosis submitted to videolaparoscopy. Image data were compared with surgical and histological results. With respect to bowel nodule detection and presence of at least two rectosigmoid lesions, TVUS-BP had a sensitivity of 97 and 81%, specificity 100 and 99%, positive predictive value (PPV) 100 and 93% and negative predictive value (NPV) 98 and 96%, respectively. Regarding diagnosis of infiltration of the submucosal/mucosal layer, TVUS-BP had a sensitivity of 83%, specificity 94%, PPV 77%, NPV 96%. These findings show that TVUS-BP is an adequate exam for evaluating the presence of one or more rectosigmoid nodules and the deepest layer affected in deep infiltrating bowel endometriosis, confirming the importance of this technique for defining the most appropriate surgical strategy to be implemented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Deeply infiltrating endometriosis is the clinical form of the disease that is generally associated with conditions of more intense pain and may require more complex surgical management, consequently resulting in greater risks to the patient. In recent years, various investigators have confirmed the usefulness of methods such as magnetic resonance imaging (MRI), transrectal ultrasound and transvaginal ultrasound (TVUS) for the diagnosis of deep endometriotic lesions. The objectives of the present study are to describe the method used to perform TVUS for the detection of deeply infiltrating endometriosis, and to discuss the clinical benefits that the data obtained may offer clinicians providing care for patients suspected of having this type of endometriosis. (C) 2008 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Deeply infiltrating endometriosis (DIE) is a common gynecologic disease that is characterized by a difficult and delayed diagnosis. Radiologic mapping of the DIE lesion sites is crucial for case management, patient counseling, and surgical planning. Transvaginal ultrasonography (US) is the initial imaging modality for investigating DIE and has been the focus of several recent studies. DIE typically manifests at imaging as hypoechogenic nodules throughout the affected sites and thickening of the intestinal wall, with some lesions showing a mixed pattern due to cystic areas. Transvaginal US performed after bowel preparation improves the ability to diagnose intestinal lesions and provides invaluable details, including which layers of the intestine are affected and the distance between the lesion and the anal border. It is vital that radiologists be familiar with the technical aspects of this modality and with the US manifestations of DIE lesions. Transvaginal US performed after bowel preparation should be the first-line imaging modality for the evaluation of women with suspected endometriosis. (C) RSNA, 2010 . radiographics.rsna.org

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Endometriosis is a common multifocal gynecologic disease that manifests during the reproductive years, often causing chronic pelvic pain and infertility. It may occur as invasive peritoneal fibrotic nodules and adhesions or as ovarian cysts with hemorrhagic content. Although findings at physical examination may be suggestive, imaging is necessary for definitive diagnosis, patient counseling, and treatment planning. The imaging techniques that are most useful for preoperative disease mapping are transvaginal ultrasonography (US) after bowel preparation, and magnetic resonance (MR) imaging. Initial transvaginal US is a reliable technique for detecting rectosigmoid endometriotic lesions. MR imaging is indicated as a complementary examination in complex cases of endometriosis with extensive adhesions and ureteral involvement. Peritoneal endometriotic implants are typically hypoechoic on transvaginal US images and demonstrate low signal intensity on T2-weighted MR images. Endometriotic implants most commonly are found in retrocervical and rectosigmoid sites, followed by the vagina, bladder, and ureters. Cysts with low-level internal echoes and echogenic peripheral foci at transvaginal US are suggestive of endometriomas. MR imaging has high specificity for identifying endometriomas, which are characterized by high signal intensity on T1-weighted images and low signal intensity on T2-weighted images. Correlation of the radiologic imaging features of endometriotic lesions with their laparoscopic appearances may help improve individual proficiency in the radiologic diagnosis of endometriosis. Supplemental material available at http:// radiographics.rsna.org/lookup/suppl/doi: 10.1148/rg.314105193/-/DC1. (C) RSNA, 2011 radiographics.rsna.org

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to differentiate benign ovarian tumors from malignant ones before surgery using color and pulsed Doppler sonography, and to compare results obtained before and after use of contrast medium, thereby verifying whether contrast results in an improvement in the diagnostic sensitivity. METHODS: Sixty two women (mean age 49.9 years) with ovarian tumors were studied, 45 with benign and 17 with malignant tumors. All women underwent a transvaginal color Doppler ultrasonographic exam. A study of the arterial vascular flow was made in all tumor areas, as well as an impedance evaluation of arterial vascular flow using the resistance index. RESULT: Localization of the vessels in the tumor revealed a greater proportion of malignant tumors with detectable internal vascular flows (64%) than benign tumors with such flows (22%). There was a considerable overlap of these findings. The use of contrast identified a greater number of vessels with confirmation in the totality of tumors, but did not improve the Doppler capacity in tumoral differentiation. Malignant tumors presented lower values of resistance index than the benign ones, whether or not contrast was used. The cutoff value for resistance index that better maximized the Doppler sensitivity and specificity was 0.55. Through this value, an increase of the sensitivity after contrast use was obtained, varying from 47% to 82%, while specificity remained statistically unchanged. CONCLUSION: Although the injection of a microbubble agent improved the sensitivity of the method detecting vascularization of tumors, a positive finding for vascularization by this method was not clinically useful in the differentiation of benign and malignant ovarian tumors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the intratumoral reliability of color Doppler parameters and the contribution of Doppler sonography to the gray-scale differential diagnosis of ovarian masses. Methods: An observational study was performed including 67 patients, 15 (22.4%) with malignant ovarian neoplasm and 52 (77.6%) with benign ovarian diseases. We performed the Doppler evaluation in two distinct vessels selected after decreasing the Doppler gain to sample only vessels with higher velocity flow. Doppler measurements were obtained from each identified vessel, and resistive index (RI), pulsatility index (PI), peak systolic velocity (PSV), and end-diastolic velocity (EDV) were measured. Intraclass coefficient of correlation (ICC), sensitivity, specificity, and potential improvement in gray-scale ultrasound performance were calculated. Results: The general ICC were 0.60 (95% CI 0.42- 0.73) for RI, 0.65 (95% CI 0.49- 0.77) for PI, 0.07 (95% CI- 0.17-0.30) for PSV, and 0.19 (95% CI -0.05-0.41) for EDV. The sensitivity and specificity were respectively 84.6% and 86.7% for RI, 69.2% and 93.3% for PI, 80.0% and 65.4% for gray-scale sonography, and 93.3% and 65.4% for gray-scale plus RI (p = 0.013). Conclusions: Gynecologists must be careful in interpreting results from Doppler evaluation of ovarian masses because PSV and EDV present poor intratumoral reliability. The lower RI value, evaluated in at least two distinct sites of the tumor, was able to improve the performance of gray-scale ultrasound in differential diagnosis of ovarian masses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To compare cervical length (CL) at 18-21 and 22-25 weeks` gestation in twin pregnancies in prediction of spontaneous preterm delivery and to examine cervical shortening. Methods: Retrospective cohort study of CL measured at 18-21 and 22-25 weeks` gestation in twin pregnancies. Results: Receiver operating characteristics (ROC) curve revealed area of 0.64 (95% CI 0.53-0.75) and 0.80 (95% CI 0.72-0.88) for measurements at 18-21 and 22-25 weeks, respectively (P <= 0.001). Sensitivities of 33.3% and 23% and negative predicting value (NPV) of 97.3% and 86.8% for delivery at <28 and <34 weeks gestation were reached for measurements at 18-21 weeks. Sensitivities of 71.4% and 38.2% and NPV of 99.1% and 91.4% for delivery at <28 and <34 weeks` gestation were reached for measurements at 22-25 weeks. Cervical length shortening analysis showed an area under ROC curve of 0.81 (95% CI 0.73-0.89) and best cut-off was at >= 2 mm/week. Sensitivities of 80% and 60.8% and NPV of 98.9% and 90.6% for delivery at <28 and <34 weeks gestation were reached. Conclusions: In twin gestations, assessment of CL at 22-25 weeks is better than assessment at 18-21 weeks to predict preterm delivery before 34 weeks. Cervical shortening at a rate of >= 2 mm/weeks between 18 and 25 weeks gestation was a good predictor of spontaneous preterm birth in this high-risk population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives/Hypothesis: Blood supply to the Hadad-Bassagasteguy pedicled nasoseptal flap may be interrupted by surgery of the pterygopalatine fossa, posterior septectomy, or large sphenoidotomies. This would preclude its use for reconstruction of skull base defects after expanded endonasal approaches (EEA). We present a novel method to ascertain the patency of the nasoseptal artery after prior surgery, and consequently the availability of the nasoseptal flap, using acoustic Doppler sonography. Study Design: Retrospective clinical review. Methods: Four patients who underwent EEAs were evaluated intraoperatively with acoustic Doppler sonography. The mucosa that covers the inferior aspect of the rostrum of the sphenoid sinus was scanned with the tip of the probe. Reflection of sound waves representing intravascular blood flow was assessed. Results: In three patients, the artery was identified in at least one side. One remaining patient showed no acoustic signal suggesting loss of the nasoseptal artery bilaterally, therefore necessitating the use of a fat graft for the reconstruction. Conclusions: Acoustic Doppler sonography seems to be a feasible and effective way to ascertain the availability of the nasoseptal artery. It is a relatively inexpensive and simple technique that can be performed by any endoscopic surgeon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To build nomograms of fetal thyroid circumference (FTC), fetal thyroid area (FTA), and fetal thyroid transverse diameter (FTTD) throughout gestational age (GA). Method. Between January 2006 and July 2006, FTC, FTA, and FTTD were measured once in 196 normal fetuses examined at a GA of 22-35 weeks. Inclusion criteria were a healthy mother with normal maternal thyrotropin level during pregnancy, a singleton pregnancy with normal fetal morphology on sonography, and GA confirmed via first-trimester sonographic examination. Results. Mean FTC, FTA, and FTTD ranged from 3.21 cm, 0.58 cm(2), and 1.19 cm at 22 weeks to 5.11 cm, 1.69 cm(2), and 1.89 cm at 35 weeks, respectively. Linear regression analysis yielded the following formulas for FTC, FTA, and FTTD according to GA: FTC (cm) = 0.146 X GA (weeks); FTA (cm(2)) = -1.289 + 0.085 X GA (weeks); FTTD (cm) = 0.054 X GA (weeks). The following logarithmic formulas were obtained for the expected fetal thyroid measurements according to estimated fetal weight (FW): FTC (cm) = -4.791 + 1.265 X logN FW; FTA (cm(2)) = -1.676 + 0.455 X logN FW; and FTTD (cm) = 0.399 + 0.001 X logN FW. Conclusion. We describe new nomograms of fetal thyroid measurements throughout gestation that may be useful in case of thyroid dysfunction. (C) 2008 Wiley Periodicals, Inc.