988 resultados para THIN-LASER CHROMATOGRAPHY
Resumo:
Forensic examinations of ink have been performed since the beginning of the 20th century. Since the 1960s, the International Ink Library, maintained by the United States Secret Service, has supported those analyses. Until 2009, the search and identification of inks were essentially performed manually. This paper describes the results of a project designed to improve ink samples' analytical and search processes. The project focused on the development of improved standardization procedures to ensure the best possible reproducibility between analyses run on different HPTLC plates. The successful implementation of this new calibration method enabled the development of mathematical algorithms and of a software package to complement the existing ink library.
Resumo:
A photometric procedure was developed for determination of aflatoxin B1 in peanuts by TLC-CCD technique. The quantification and detection limit were 1.2 μg kg-1 and 0.4 ng per spot, respectively, with mean recovery of 98%. The CCD camera is sufficiently sensitive to detect small changes in spots fluorescence intensity and the results for performance confirmed the efficiency of the method. Another important property of CCD detector is its linearity for a wide range of luminous stimulus determined by analysis of five-point calibration curves using the intensity of AFB1 fluorescence versus AFB1 concentration (0.8 to 4.8 ng per spot). The method was applied to the analysis of thirty nine peanut samples and aflatoxin B1 levels ranged from 16 to 115 μg kg-1. The TLC-CCD and the photometric procedure developed in this study demonstrated to be a simple and efficient tool for quantitative analyses of AFB1 in peanut samples.
Resumo:
A method for determining aflatoxins B1 (AFB1), B2 (AFB2),G1 (AFG1) andG2 (AFG2) in maize with florisil clean up was optimised aiming at one-dimensional thin layer chromatography (TLC) analysis with visual and densitometric quantification. Aflatoxins were extracted with chloroform: water (30:1, v/v), purified through florisil cartridges, separated on TLC plate, detected and quantified by visual and densitometric analysis. The in-house method performance characteristics were determined by using spiked, naturally contaminated maize samples, and certified reference material. The mean recoveries for aflatoxins were 94.2, 81.9, 93.5 and 97.3% in the range of 1.0 to 242 µg/kg for AFB1, 0.3 to 85mg/kg for AFB2, 0.6 to 148mg/kg for AFG1 and 0.6 to 140mg/kg for AFG2, respectively. The correlation values between visual and densitometric analysis for spiked samples were higher than 0.99 for AFB1, AFB2, AFG1 and 0.98 for AFG2. The mean relative standard deviations (RSD) for spiked samples were 16.2, 20.6, 12.8 and 16.9% for AFB1, AFB2, AFG1 and AFG2, respectively. The RSD of the method for naturally contaminated sample (n = 5) was 16.8% for AFB1 and 27.2% for AFB2. The limits of detection of the method (LD) were 0.2, 0.1, 0.1 and 0.1mg/kg and the limits of quantification (LQ) were 1.0, 0.3, 0.6 and 0.6mg/kg for AFB1, AFB2, AFG1 and AFG2, respectively.
Resumo:
Abstract The present work describes setting up a laboratory unit for supercritical fluid extraction. In addition to its construction, a survey of cost was done to compare the cost of the homemade unit with that of commercial units. The equipment was validated using an extraction of annatto seeds’ oil, and the extraction and fractionation of fennel oil were used to validate the two separators; for both systems, the solvent was carbon dioxide. The chemical profiles of annatto and fennel extracts were assessed using thin layer chromatography; the images of the chromatographic plates were processed using the free ImageJ software. The cost survey showed that the homemade equipment has a very low cost (~US$ 16,000) compared to commercial equipment. The extraction curves of annatto were similar to those obtained in the literature (yield of 3.8% oil). The separators were validated, producing both a 2.5% fraction of fennel seed extract rich in essential oils and another extract fraction composed mainly of oleoresins. The ImageJ software proved to be a low-cost tool for obtaining an initial evaluation of the chemical profile of the extracts.
Resumo:
Forty seven strains of mycobacteria (35 strains isolated from clinical specimens and 12 reference strains) were analyzed for mycobactin and mycolate production by thin-layer chromatography (TLC). Different growth conditions had little or no effect on the production of individual mycobactins and the reproducibility of mycobactin Rf values. Mycolate profiles of isolated strains were compared with those of reference strains. Clinical isolates belonging to the same species showed the same profiles. The combined evaluation of mycobacterial products by TLC allowed the identification of pathogenic and opportunist cultivable mycobacteria. on routine examination, the analysis of mycobactin and mycolate production constitutes an adequate procedure for the characterization and identification of myobacteria.
Resumo:
The development of fast, inexpensive, and reliable tests to identify nontuberculous mycobacteria (NTM) is needed. Studies have indicated that the conventional identification procedures, including biochemical assays, are imprecise. This study evaluated a proposed alternative identification method in which 83 NTM isolates, previously identified by conventional biochemical testing and in-house M. avium IS1245-PCR amplification, were submitted to the following tests: thin-layer chromatography (TLC) of mycolic acids and PCR-restriction enzyme analysis of hsp65 (PRA). High-performance liquid chromatography (HPLC) analysis of mycolic acids and Southern blot analysis for M. avium IS1245 were performed on the strains that evidenced discrepancies on either of the above tests. Sixty-eight out of 83 (82%) isolates were concordantly identified by the presence of IS1245 and PRA and by TLC mycolic acid analysis. Discrepant results were found between the phenotypic and molecular tests in 12/83 (14.4%) isolates. Most of these strains were isolated from non-sterile body sites and were most probably colonizing in the host tissue. While TLC patterns suggested the presence of polymycobacterial infection in 3/83 (3.6%) cultures, this was the case in only one HPLC-tested culture and in none of those tested by PRA. The results of this study indicated that, as a phenotypic identification procedure, TLC mycolic acid determination could be considered a relatively simple and cost-effective method for routine screening of NTM isolates in mycobacteriology laboratory practice with a potential for use in developing countries. Further positive evidence was that this method demonstrated general agreement on MAC and M. simiae identification, including in the mixed cultures that predominated in the isolates of the disseminated infections in the AIDS patients under study. In view of the fact that the same treatment regimen is recommended for infections caused by these two species, TLC mycolic acid analysis may be a useful identification tool wherever molecular methods are unaffordable.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The reaction of living anionic polymers with 2,2,5,5-tetramethyl-1-(3-bromopropyl)-1-aza-2,5- disilacyclopentane (1) was investigated using coupled thin layer chromatography and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Structures of byproducts as well as the major product were determined. The anionic initiator having a protected primary amine functional group, 2,2,5,5-tetramethyl- 1-(3-lithiopropyl)-1-aza-2,5-disilacyclopentane (2), was synthesized using all-glass high-vacuum techniques, which allows the long-term stability of this initiator to be maintained. The use of 2 in the preparation of well-defined aliphatic primary amine R-end-functionalized polystyrene and poly(methyl methacrylate) was investigated. Primary amino R-end-functionalized poly(methyl methacrylate) can be obtained near-quantitatively by reacting 2 with 1,1-diphenylethylene in tetrahydrofuran at room temperature prior to polymerizing methyl methacrylate at -78 °C. When 2 is used to initiate styrene at room temperature in benzene, an additive such as N,N,N',N'- tetramethylethylenediamine is necessary to activate the polymerization. However, although the resulting polymers have narrow molecular weight distributions and well-controlled molecular weights, our mass spectra data suggest that the yield of primary amine α-end-functionalized polystyrene from these syntheses is very low. The majority of the products are methyl α-end-functionalized polystyrene.
Resumo:
Introduction: Paper and thin layer chromatography methods are frequently used in Classic Nuclear Medicine for the determination of radiochemical purity (RCP) on radiopharmaceutical preparations. An aliquot of the radiopharmaceutical to be tested is spotted at the origin of a chromatographic strip (stationary phase), which in turn is placed in a chromatographic chamber in order to separate and quantify radiochemical species present in the radiopharmaceutical preparation. There are several methods for the RCP measurement, based on the use of equipment as dose calibrators, well scintillation counters, radiochromatografic scanners and gamma cameras. The purpose of this study was to compare these quantification methods for the determination of RCP. Material and Methods: 99mTc-Tetrofosmin and 99mTc-HDP are the radiopharmaceuticals chosen to serve as the basis for this study. For the determination of RCP of 99mTc-Tetrofosmin we used ITLC-SG (2.5 x 10 cm) and 2-butanone (99mTc-tetrofosmin Rf = 0.55, 99mTcO4- Rf = 1.0, other labeled impurities 99mTc-RH RF = 0.0). For the determination of RCP of 99mTc-HDP, Whatman 31ET and acetone was used (99mTc-HDP Rf = 0.0, 99mTcO4- Rf = 1.0, other labeled impurities RF = 0.0). After the development of the solvent front, the strips were allowed to dry and then imaged on the gamma camera (256x256 matrix; zoom 2; LEHR parallel-hole collimator; 5-minute image) and on the radiochromatogram scanner. Then, strips were cut in Rf 0.8 in the case of 99mTc-tetrofosmin and Rf 0.5 in the case of 99mTc-HDP. The resultant pieces were smashed in an assay tube (to minimize the effect of counting geometry) and counted in the dose calibrator and in the well scintillation counter (during 1 minute). The RCP was calculated using the formula: % 99mTc-Complex = [(99mTc-Complex) / (Total amount of 99mTc-labeled species)] x 100. Statistical analysis was done using the test of hypotheses for the difference between means in independent samples. Results:The gamma camera based method demonstrated higher operator-dependency (especially concerning the drawing of the ROIs) and the measures obtained using the dose calibrator are very sensitive to the amount of activity spotted in the chromatographic strip, so the use of a minimum of 3.7 MBq activity is essential to minimize quantification errors. Radiochromatographic scanner and well scintillation counter showed concordant results and demonstrated the higher level of precision. Conclusions: Radiochromatographic scanners and well scintillation counters based methods demonstrate to be the most accurate and less operator-dependant methods.
Resumo:
Mycolic acids analysis by thin-layer chromatography (TLC) has been employed by several laboratories worldwide as a method for fast identification of mycobacteria. This method was introduced in Brazil by our laboratory in 1992 as a routine identification technique. Up to the present, 861 strains isolated were identified by mycolic acids TLC and by standard biochemical tests; 61% out of these strains came as clinical samples, 4% isolated from frogs and 35% as environmental samples. Mycobacterium tuberculosis strains identified by classical methods were confirmed by their mycolic acids contents (I, III and IV). The method allowed earlier differentiation of M. avium complex - MAC (mycolic acids I, IV and VI) from M. simiae (acids I, II and IV), both with similar biochemical properties. The method also permitted to distinguish M. fortuitum (acids I and V) from M. chelonae (acids I and II) , and to detect mixed mycobacterial infections cases as M. tuberculosis with MAC and M. fortuitum with MAC. Concluding, four years experience shows that mycolic acids TLC is an easy, reliable, fast and inexpensive method, an important tool to put together conventional mycobacteria identification methods.
Resumo:
Usually, the differentiation of inks on questioned documents is carried out by optical methods and thin layer chromatography (TLC). Therefore, spectrometric methods were also proposed in forensic literature for the analysis of dyes. Between these techniques, laser desorption/ionization mass spectrometry (LDI-MS) has demonstrated a great versatility thanks to its sensitivity to blue ballpoint ink dyes and minimal sample destruction. Previous researches concentrated mostly on the LDI-MS positive mode and have shown that this analytical tool offers higher discrimination power than high performance TLC (HPTLC) for the differentiation of blue ballpoint inks. Although LDI-MS negative mode has already been applied in numerous forensic domains like the studies of works of art, automotive paints or rollerball pens, its potential for the discrimination of ballpoint pens was never studied before. The aim of the present paper is therefore to evaluate its potential for the discrimination of blue ballpoint inks. After optimization of the method, ink entries from 33 blue ballpoint pens were analyzed directly on paper in both positive and negative modes by LDI-MS. Several cationic and anionic ink components were identified in inks; therefore, pens were classified and compared according to their formulations. Results show that additional information provided by anionic dyes and pigments significantly increases the discrimination power of positive mode. In fact, it was demonstrated that classifications obtained by the two modes were, to some extent, complementary (i.e., inks with specific cationic dyes not necessarily contained the same anionic components).
Resumo:
RESUME La méthode de la spectroscopie Raman est une technique d'analyse chimique basée sur l'exploitation du phénomène de diffusion de la lumière (light scattering). Ce phénomène fut observé pour la première fois en 1928 par Raman et Krishnan. Ces observations permirent à Raman d'obtenir le Prix Nobel en physique en 1930. L'application de la spectroscopie Raman a été entreprise pour l'analyse du colorant de fibres textiles en acrylique, en coton et en laine de couleurs bleue, rouge et noire. Nous avons ainsi pu confirmer que la technique est adaptée pour l'analyse in situ de traces de taille microscopique. De plus, elle peut être qualifiée de rapide, non destructive et ne nécessite aucune préparation particulière des échantillons. Cependant, le phénomène de la fluorescence s'est révélé être l'inconvénient le plus important. Lors de l'analyse des fibres, différentes conditions analytiques ont été testées et il est apparu qu'elles dépendaient surtout du laser choisi. Son potentiel pour la détection et l'identification des colorants imprégnés dans les fibres a été confirmé dans cette étude. Une banque de données spectrale comprenant soixante colorants de référence a été réalisée dans le but d'identifier le colorant principal imprégné dans les fibres collectées. De plus, l'analyse de différents blocs de couleur, caractérisés par des échantillons d'origine inconnue demandés à diverses personnes, a permis de diviser ces derniers en plusieurs groupes et d'évaluer la rareté des configurations des spectres Raman obtenus. La capacité de la technique Raman à différencier ces échantillons a été évaluée et comparée à celle des méthodes conventionnelles pour l'analyse des fibres textiles, à savoir la micro spectrophotométrie UV-Vis (MSP) et la chromatographie sur couche mince (CCM). La technique Raman s'est révélée être moins discriminatoire que la MSP pour tous les blocs de couleurs considérés. C'est pourquoi dans le cadre d'une séquence analytique nous recommandons l'utilisation du Raman après celle de la méthode d'analyse de la couleur, à partir d'un nombre de sources lasers le plus élevé possible. Finalement, la possibilité de disposer d'instruments équipés avec plusieurs longueurs d'onde d'excitation, outre leur pouvoir de réduire la fluorescence, permet l'exploitation d'un plus grand nombre d'échantillons. ABSTRACT Raman spectroscopy allows for the measurement of the inelastic scattering of light due to the vibrational modes of a molecule when irradiated by an intense monochromatic source such as a laser. Such a phenomenon was observed for the first time by Raman and Krishnan in 1928. For this observation, Raman was awarded with the Nobel Prize in Physics in 1930. The application of Raman spectroscopy has been undertaken for the dye analysis of textile fibers. Blue, black and red acrylics, cottons and wools were examined. The Raman technique presents advantages such as non-destructive nature, fast analysis time, and the possibility of performing microscopic in situ analyses. However, the problem of fluorescence was often encountered. Several aspects were investigated according to the best analytical conditions for every type/color fiber combination. The potential of the technique for the detection and identification of dyes was confirmed. A spectral database of 60 reference dyes was built to detect the main dyes used for the coloration of fiber samples. Particular attention was placed on the discriminating power of the technique. Based on the results from the Raman analysis for the different blocs of color submitted to analyses, it was possible to obtain different classes of fibers according to the general shape of spectra. The ability of Raman spectroscopy to differentiate samples was compared to the one of the conventional techniques used for the analysis of textile fibers, like UV-Vis Microspectrophotometry (UV-Vis MSP) and thin layer chromatography (TLC). The Raman technique resulted to be less discriminative than MSP for every bloc of color considered in this study. Thus, it is recommended to use Raman spectroscopy after MSP and light microscopy to be considered for an analytical sequence. It was shown that using several laser wavelengths allowed for the reduction of fluorescence and for the exploitation of a higher number of samples.