989 resultados para THERMOREMANENT MAGNETIZATION
Resumo:
The work reported in this thesis is dedicated to irreversible magnetic properties in pyrolytic nanocarbon samples. Based on atomic force microscope images, the samples consist of carbon clusters with radius 30..120 nm. These are treated as single-domain nanoparticles. Magnetic hysteresis, field cooled, zero field cooled and thermoremanent magnetization measurements were performed using an RF SQUID magnetometer and ferromagnetic behaviour was observed. Analysis suggests that the ferromagnetic ordering is associated with defects in a thin surface layer, whose thickness is independent of particle size. Critical radius for single-domain particles, critical radius for coherent rotation, magnetic layer thickness, distance between elementary magnetic moments, saturation magnetization, exchange stiffness constant and anisotropy energy density are also presented.
Resumo:
Na primeira parte deste trabalho foram desenvolvidos estudos de magnetismo de rochas e paleomagnetismo em amostras de rochas vulcânicas do Nordeste brasileiro. As idades das amostras compreende os períodos Jurássico e Cretáceo. Com este objetivo foram amostradas quatro áreas tendo sido estudado um total de 496 amostras em 55 sítios. Para a coleta foi utilizada uma perfuradora portátil que extrai amostras de 2.5 cm de diâmetro. A orientação das amostras foi feita por meio de uma bússola magnética e de um clinômetro. Os espécimes foram submetidos a desmagnetizações por campo magnético alternado e em alguns poucos casos foi empregada a desmagnetização térmica. Atribuindo-se peso unitário a cada sítio foi determinada a direção média da magnetização remanescente característica de cada uma das áreas estudadas. As rochas vulcânicas do período Jurássico, localizadas na borda oeste da Bacia do Maranhão (Porto Franco-Estreito), apresentaram uma direção media em que D= 3.9°, I= -17.9° com α95= 9.3°, k= 17.9, N= 15 e todos os sítios apresentaram polaridade normal. Para esta área foi determinado o polo paleomagnético de coordenadas 85.3°N, 82.5°E (A95= 6.9º) que se localiza próximo a outros polos paleomagnéticos conhecidos para esse período. As rochas da borda leste da Bacia do Maranhão (Teresina-Picos-Floriano) de idade cretácica inferior apresentaram uma direção média de magnetização remanescente característica tal que D= 174.7°, I= +6.0º com α95= 2.8º, k= 122, N= 21 e todos os sítios apresentaram polaridade reversa. O polo paleomagnético associado a elas apresentou por coordenadas 83.6°N, 261.0°E (A95=1.9°) e mostrou concordância com outros polos sul americanos de mesma idade. No Rio Grande do Norte foi estudado um enxame de diques toleíticos também de idade cretácica inferior, cuja direção média da magnetização remanescente característica encontrada foi D= 186.6º, I= +20.6º com α95= 14.0° e k= 12.9, N= 10. Os sítios desta área apresentaram magnetizações com polaridades normal a reversa. O polo paleomagnético obtido se localiza em 80.6°N e 94.8°E com A95= 9.5°. O estudo das rochas vulcânicas da província magnética do Cabo de Santo Agostinho indicou para a região um valor de D= 0.4º, I= -20.6º com α95= 4.8° e k= 114, N= 9 para a magnetização remanescente característica. Todos os sítios apresentaram polaridade normal e o polo paleomagnético determinado apresentou as seguintes coordenadas: 87.6ºN, 135ºE com A95= 4.5º. Foi discutida a eliminação da variação secular das direções obtidas, de forma que cada polo apresentado nesta dissertação é verdadeiramente um polo paleomagnético. A análise dos minerais magnéticos portadores da remanência, efetuada por curvas termomagnéticas ou por difração de Raio-X, indicou na maior parte das ocorrências, a presença de titanomagnetita pobre em titânio. A presença de maguemita e algumas vezes hematita, na maior parte das vezes resultado de intemperismo, não anulou a magnetização termoremanente associada à época de formação da rocha, que foi determinada após a aplicação de técnicas de desmagnetização aos espécimes. Pelas curvas termomagnéticas obteve-se, para a maioria das amostras, uma temperatura de Curie entre 500 e 600ºC. Os casos mais freqüentes indicaram a ocorrência de titanomagnetita exsolvida, em que foram observadas a presença de uma fase próxima à magnetita e outra fase rica em titânio, próxima à ilmenita, resultado de oxidação de alta temperatura. A segunda parte do trabalho diz respeito à determinação da época de abertura do oceano Atlântico Sul por meio de dados paleomagnéticos. Entretanto ao invés de se utilizar o procedimento comumente encontrado na literatura, e que se baseia nas curvas de deriva polar aparente de cada continente, foi aplicado um teste estatístico que avalia a probabilidade de determinada posição relativa entre os continentes ser válida ou não, para determinado período em estudo. Assim foi aplicado um teste F a polos paleomagnéticos da África e da América do Sul, dos períodos Triássico, Jurássico, Cretáceo Inferior e Cretáceo Médio-Superior, tendo sido estudadas situações que reconstituem a posição pré-deriva dos continentes e configurações que simulem um afastamento entre eles. Os resultados dos testes estatísticos indicaram, dentro de uma probabilidade de erro de menos de 5%, que a configuração pré-deriva de Martin et al (1981) é compatível com os dados paleomagnéticos do Triássico, mas apresenta uma diferença significativa para os paleopolos de Jurássico, Cretáceo Inferior, Cretáceo Médio-Superior. Outras reconstruções pré-deriva testadas apresentaram o mesmo resultado. A comparação entre os polos paleomagnéticos da América do Sul e da África, segundo uma reconstrução que admite uma pequena abertura entre os continentes, como a proposta por Sclater et al (1977) para 110 m.a. atrás, indicou que os dados do Triássico não são compatíveis com este afastamento. Por outro lado os paleopolos do Jurássico e do Cretáceo Inferior, embora mais antigos que a data sugerida pela reconstrução, são consistentes com esta separação dentro de uma probabilidade de erro de menos de 5%. Os dados do Cretáceo Médio-Superior se mostraram consistentes com a reconstrução sugerida para 80 m.a. atrás por Francheteau (1973) e que propõe uma separação maior entre os continentes. Com base na premissa de deslocamentos de blocos continentais rígidos a análise dos resultados obtidos indicou que América do Sul e África estavam unidas por suas margens continentais opostas no período Triássico e que uma pequena separação entre estes continentes, provavelmente devida a uma rutura inicial, ocorreu no Jurássico e se manteve, então, aproximadamente estacionária até o início do Cretáceo Inferior. Esta conclusão difere da maior parte dos trabalhos que discutem a abertura do oceano Atlântico Sul. Os dados do Cretáceo Médio-Superior são compatíveis com um afastamento rápido e significativo entre os continentes naquele período.
Resumo:
We report new archeointensity data obtained from the analyses of baked clay elements (architectural and kiln brick fragments) sampled in Southeast Brazil and historically and/or archeologically dated between the end of the XVIth century and the beginning of the XXth century AD. The results were determined using the classical Thellier and Thellier protocol as modified by Coe, including partial thermoremanent magnetization (pTRM) and pTRM-tail checks, and the Triaxe protocol, which involves continuous high-temperature magnetization measurements. In both protocols, TRM anisotropy and cooling rate TRM dependence effects were taken into account for intensity determinations which were successfully performed for 150 specimens from 43 fragments, with a good agreement between intensity results obtained from the two procedures. Nine site-mean intensity values were derived from three to eight fragments and defined with standard deviations of less than 8%. The site-mean values vary from similar to 25 mu T to similar to 42 mu T and describe in Southeast Brazil a continuous decreasing trend by similar to 5 mu T per century between similar to 1600 AD and similar to 1900 AD. Their comparison with recent archeointensity results obtained from Northeast Brazil and reduced at a same latitude shows that: (1) the geocentric axial dipole approximation is not valid between these southeastern and northeastern regions of Brazil, whose latitudes differ by similar to 10 degrees, and (2) the available global geomagnetic field models (gufm1 models, their recalibrated versions and the CALSK3 models) are not sufficiently precise to reliably reproduce the non-dipole field effects which prevailed in Brazil for at least the 1600-1750 period. The large non-dipole contribution thus highlighted is most probably linked to the evolution of the South Atlantic Magnetic Anomaly (SAMA) during that period. Furthermore, although our dataset is limited, the Brazilian archeointensity data appear to support the view of a rather oscillatory behavior of the axial dipole moment during the past three centuries that would have been marked in particular by a moderate increase between the end of the XVIIIth century and the middle of the XIXth century followed by the well-known decrease from 1840 AD attested by direct measurements. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
This study presents the first archeointensity results from Northeast Brazil obtained from 14 groups of architectural brick fragments sampled in the city of Salvador, Bahia State (13 degrees S, 38.5 degrees W) and dated between the middle of the XVIth century and the beginning of the XIXth century. The dating is ascertained by historical documents complemented by archeological constraints, yielding in all cases age uncertainties of less than 50 years. Analyses were carried out using two experimental protocols: 1 the ""zero field-in field"" version of the classical Thellier and Thellier method as proposed by Coe (TT-ZI), including partial thermoremanent magnetization (pTRM) and pTRM-tail checks, and 2 the Triaxe procedure involving continuous high temperature magnetization measurements. Both TRM anisotropy and cooling rate effects were taken into account for the intensity determinations. The cooling rate effect was further explored for the TT-ZI protocol using three increasing slow cooling times (5 h, 10 h and 25 h) between 450 C and room temperature. Following archeological constraints, the slowest cooling time was retained in our study, yielding decreases of the raw intensity values by 4% to 14%. For each fragment, a mean intensity was computed and retained only when the data obtained from all specimens (between 2 and 6) satisfied a coherence test at similar to 5%. A total of 57 fragments (183 specimens) was considered for the computations of site-mean intensity values, with derived standard deviations of less than 8% of the corresponding means. When separately computed using the two experimental techniques, the site-mean intensity values always agree to within 5%. A good consistency is observed between intensity values of similar or close ages, which strengthen their reliability. Our data principally show a significant and continuous decrease in geomagnetic field intensity in Northeast Brazil between the first half of the XVIIth century and the XXth century. One result dated to the second half of the XVIth century further suggests that the geomagnetic field intensity reached a maximum around 1600 AD. This evolution is in good agreement with that expected in the city of Salvador from the available global geomagnetic field models. However, the accuracy of these models appears less well constrained between similar to 1550 AD and similar to 1650 AD. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Ocean Drilling Program (ODP) Hole 735B was drilled to a depth of 1.5 km in a tectonic window of gabbroic lower oceanic crust created at the Southwest Indian Ridge. The gabbros have a very stable natural remanent magnetization (NRM) of reversed polarity with most unblocking temperatures slightly below the Curie temperature of magnetite. The NRM includes a drilling-induced overprint but its intensity decays strongly towards the interior of the drill core. The demagnetization data yield no or only a very small secondary magnetization component acquired during the present Brunhes chron or an earlier normal chron, suggesting cooling through most of the blocking temperature range during chron C5r and a strong resistance against the acquisition of thermoviscous magnetization. A novel furnace has been designed to measure magnetizations and their time dependences at high temperatures (up to 580 deg C) inside a commercial SQUID magnetometer. Magnetic viscosity experiments have been conducted on the gabbros at temperatures up to 550 deg C to determine the time and temperature stability of remanent magnetization. Viscosities are generally small and increase little with temperature below the main blocking temperature, where the increase becomes almost an order of magnitude. Extrapolations to geological times infer viscous acquisitions that would be 5-25% of a thermoremanence in 100 kyr and at temperatures of 200-500 deg C. At ocean bottom temperature the predicted magnetization of one sample acquired in the present Brunhes chron should be 10% of the NRM. However, this is not recognized during NRM demagnetization and partial thermoremanent magnetization (pTRM) acquisitions at 250 deg C are also much smaller than predicted. It thus appears that the NRMs are generally magnetically harder than magnetizations acquired after heating to 570 deg C in the laboratory. Susceptibility changes during heating are small (<5%) indicating a seemingly stable magneto-mineralogy, but conspicuous minima occur after heating to 520 deg C. Also, quasi paleointensity experiments reveal characteristic patterns in the NRM/pTRM ratios and also large increases in pTRM capacity after heating to 570 deg C. Moreover, anhysteretic remanent magnetization acquisition in the low field range (<=10 mT) is strongly enhanced after heating by factors up to three. The alteration of the magneto-mineralogy is interpreted to result from the annealing of defects in magnetite that originate from tectonically induced strain. The oceanic gabbros of Hole 735B are thus ideal source layer material for marine magnetic anomalies, and secondary thermoviscous acquisition, as a possible cause for anomalous skewness, is essentially absent.
Resumo:
Paleomagnetic parameters of 55 basalt samples from Hole 648B on the Mid-Atlantic Ridge were studied. Negative NRM inclinations were found for 10 samples between 10 and 25 m sub-bottom depth. Several hypotheses related to this phenomenon are discussed. NRM intensities, susceptibilities, median destructive fields, and Koenigsberger ratios are slightly different for pillow and massive basalts. One can suggest from measured parameters that magnetic carriers for massive and pillow basalts are PSD titanomagnetite grains more or less close to PSD-MD threshold size with a low degree of alteration.
Resumo:
The magnetic properties of 56 samples of basalt from DSDP Leg 82 were studied in order to examine regional variations as well as the general question of the origin or remanence. Magnetization was carried, for the most part, by typical low temperature oxidized titanomagnetites, although two samples did show anomalous thermomagnetic curves. The natural remanence is distinctly different from an anhysteretic remanent magnetization and is hypothesized (by inference) to also be different from a thermoremanent magnetization (TRM) also. This suggests that alteration not only reduces the initial TRM but also changes it to chemical remanent magnetization with a significantly different magnetic character. An examination of thermomagnetic data tentatively suggests that the ulvospinel content of the titanomagnetites may be more variable than is commonly assumed. With the exception of a slight increase in saturation magnetization with decreasing latitude, no significant regional variations were evident.
Resumo:
On the basis of studies of Holocene samples,submarine basaltic glass (SBG) is thought to be an ideal paleointensity recorder because it contains unaltered single domain magnetic inclusions that yield Thellier paleointensity data of exceptional quality. To be useful as a recorder of the long-term geomagnetic field, older SBG must retain these optimal properties. Here, we examine this issue through rock magnetic and transmission electron microscope (TEM) analyses of Cretaceous SBG recovered at Ocean Drilling Program Site 1203 (northwestern Pacific Ocean). These SBG samples have very low natural remanent magnetization intensities (NRM <50 nAm**2/g) and TEM analyses indicate a correspondingly low concentration of crystalline inclusions. Thellier experiments on samples with the strongest NRM intensity (>5*10**-11 Am**2) show a rapid acquisition of thermoremanent magnetization (TRM) with respect to NRM demagnetization. Taken at face value,this behavior implies magnetization in a very weak (617 WT) ambient field. But monitoring of magnetic hysteresis properties during the Thellier experiments (on subsamples of the SBG samples used for paleointensity determinations) indicates systematic variations in values over the same temperature range where the rapid TRM acquisition is observed. A similar change in properties during heating is observed on monitor SBG specimens using low-temperature data: with progressive heatings the Verwey transition becomes more distinct. We suggest that these experimental data record the partial melting and neocrystallization of magnetic grains in SBG during the thermal treatments required by the Thellier method,resulting in paleointensity values biased to low values. We further propose that this process is pronounced in Cretaceous and Jurassic SBG (relative to Holocene SBG) because devitrification on geologic time scales (i.e., tens of millions of years) lowers the transition temperature at which the neocrystallization can commence. Magnetic hysteresis monitoring may provide a straightforward means of detecting the formation of new magnetic inclusions in SBG during Thellier experiments.
Resumo:
We report accurate magnetization measurements on the spin-gap compound NiCl(2)-4SC (NH(2))(2) around the low portion of the magnetic induced phase ordering. The critical density of the magnetization at the phase boundary is analyzed in terms of a Bose-Einstein condensation (BEC) of bosonic particles, and the boson interaction strength is obtained as upsilon(0)=0.61 meV. The detailed analysis of the magnetization data across the transition leads to the conclusion for the preservation of the U(1) symmetry, as required for BEC. (c) 2009 American Institute of Physics. [DOI: 10.1063/1.3055265]
Resumo:
CoB, CO(2)B, CoSi, Co(2)Si and CO(5)Si(2)B phases can be formed during heat-treatment of amorphous co-Si-B soft magnetic materials. Thus, it is important to determine their magnetic behavior as a function of applied field and temperature. In this study, polycrystalline single-phase samples of the above phases were produced via arc melting and heat-treatment under argon. The single-phase nature of the samples was confirmed via X-ray diffraction experiments. AC and DC magnetization measurements showed that Co(2)Si and CO(5)Si(2)B phases are paramagnetic. Minor amounts of either Co(2)Si or CoSi(2) in the CoSi-phase sample suggested a paramagnetic behavior of the CoSi-phase, however, it should be diamagnetic as shown in the literature. The diamagnetic behavior of the CoB phase was also confirmed. The paramagnetic behavior of CO(5)Si(2)B is for the first time reported. The magnetization results of the phase CO(2)B have a ferromagnetic signature already verified on previous NMR studies. A detailed set of magnetization measurements of this phase showed a change of the easy magnetization axis starting at 70K, with a temperature interval of about 13K at a very small field of 1 mT. As the strength of the field is increased the temperature interval is enlarged. The strength of field at which the magnetization saturates increases almost linearly as the temperature is increased above 70K. The room temperature total magnetostriction of the CO(2)B phase was determined to be 8 ppm at a field of 1T. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Off-resonance RF pre-saturation was used to obtain contrast in MRI images of polymer gel dosimeters irradiated to doses up to 50 Gy. Two different polymer gel dosimeters composed of 2-hydroxyethyl-acryl ate or methacrylic acid monomers mixed with N, N'-methylene-bisacrylamide (BIS), dispersed in an aqueous gelatin matrix were evaluated. Radiation-induced polymerization of the co-monomers generates a fast-relaxing insoluble polymer. Saturation of the polymer using off-resonance Gaussian RF pulses prior to a spin-echo read-out with a short echo time leads to contrast that is dependent on the absorbed dose. This contrast is attributed to magnetization transfer (MT) between free water and the polymer, and direct saturation of water was found to be negligible under the prevailing experimental conditions. The usefulness of MT imaging was assessed by computing the dose resolution obtained with this technique. We found a low value of dose resolution over a wide range of doses could be obtained with a single experiment. This is an advantage over multiple spin echo (MSE) experiments using a single echo spacing where an optimal dose resolution is achieved over only very limited ranges of doses. The results suggest MT imaging protocols may be developed into a useful tool for polymer gel dosimetry.
Resumo:
Purpose: To define the role of magnetization transfer imaging (MTI) in detecting subclinical central nervous system (CNS) lesions in primary antiphospholipid syndrome (PAPS). Materials and Methods: Ten non-CNS PAPS patients were compared to 10 CNS PAPS patients and 10 age- and sex-matched controls. All PAPS patients met Sapporo criteria. All Subjects underwent conventional MRI and complementary MTI analysis to compose histograms. CNS viability was determined according to the magnetization transfer ratio (MTR) by mean pixel intensity (MPI) and the mean peak height (MPH). Volumetric cerebral measurements were assessed by brain parenchyma factor (BPF) and total/cerebral volume. Results: MTR histograms analysis revealed that MPI was significantly different among groups (P < 0.0001). Non-CNS PAPS had a higher MPI than CNS PAPS, (30.5 +/- 1.01 vs. 25.1 +/- 3.17 percent unit (pu); P < 0.05) although lower than controls (30.5 +/- 1.01 vs. 31.20 < 0.50 pu; P < 0.05). MPH in non-CNS PAPS (5.57 +/- 0.20% (1/pu)} was similar to controls (5.63 +/- 0.20% (1/pu), P > 0.05) and higher than CNS PAPS (4.71 +/- 0.30% (1/pu), P < 0.05). A higher peak location (PL) was also observed in the CNS PAPS group in comparison with the other groups (P < 0.0001). In addition, a lower BPF was found in non-CNS PAPS compared to controls (0.80 +/- 0.03 vs. 0.84 +/- 0.02 units; P < 0.05) but similar to CNS PAPS (0.80 +/- 0.03 vs. 0.79 +/- 0.05 units; P > 0.05). Conclusion: Our findings suggest that non-CNS PAPS patients have subclinical cerebral damage. The long-term-clinical relevance of MTI analysis in these patients needs to be defined by prospective studies.
Resumo:
MRI is an important tool for investigating breast cancer. Although recognized as the method of choice for screening highrisk patients, and for other indications the role of MRI for lesion characterization remains controversial. Recently some authors have advocated the use of morphologic and postcontrast features for this purpose. Quantitative breast MRI techniques have not been applied extensively in breast diseases. Magnetization transfer (MT) is a quantitative MR technique commonly used to investigate neurological diseases. In breast diseases the use of MT has been limited to improving visualization of areas of enhancement in postcontrast images. The purpose of this study was to evaluate the feasibility and utility of MT in discriminating benign from malignant breast lesions. Fifty-two lesions, Bl-RADS 4 and 5, from 49 patients, were prospectively evaluated using the MT ratio (MTR). Patients were divided into two groups: benign and malignant lesions. The MTR of fat, pectoralis major muscle, fibroglandular tissue, and breast lesions were calculated. A statistically significant difference was found between MTR from benign and malignant lesions (P < 0.001). Preliminary results suggest that MT can be used to evaluate breast lesions. Further studies are necessary to better define the utility and applicability of this technique.
Resumo:
Films of BaFe12O19/P(VDF-TrFE) composites with 5, 10 and 20 %wt Barium ferrite content have been fabricated. BaFe12O19 microparticles have the shape of thin hexagonal platelets, the easy direction of magnetization remaining along the c axis, which is perpendicular to the plates. This fact allows for ferrite particles orientation in-plane and out-of-plane within the composite films, as confirmed by measured hysteresis loops. While the in-plane induced magnetoelectric effect (ME) is practically zero, these composite films show a good out-of-plane magnetoelectric effect. with maximum ME coupling coefficient changes of 3, 17 and 2 mV/cm.Oe for the 5, 10 and 20%wt Barium ferrite content films, respectively. We infer that this ME behavior appears as driven by the magnetization process arising when we applied the external magnetic field. We have also measured linear and reversible magnetoelectric effect for low applied bias field, when magnetization process is still reversible.
Resumo:
PURPOSE: To investigate magnetization transfer (MT) effects as a new source of contrast for imaging and tracking of peripheral foot nerves. MATERIALS AND METHODS: Two sets of 3D spoiled gradient-echo images acquired with and without a saturation pulse were used to generate MT ratio (MTR) maps of 260 μm in-plane resolution for eight volunteers at 3T. Scan parameters were adjusted to minimize signal loss due to T2 dephasing, and a dedicated coil was used to improve the inherently low signal-to-noise ratio of small voxels. Resulting MTR values in foot nerves were compared with those in surrounding muscle tissue. RESULTS: Average MTR values for muscle (45.5 ± 1.4%) and nerve (21.4 ± 3.1%) were significantly different (P < 0.0001). In general, the difference in MTR values was sufficiently large to allow for intensity-based segmentation and tracking of foot nerves in individual subjects. This procedure was termed MT-based 3D visualization. CONCLUSION: The MTR serves as a new source of contrast for imaging of peripheral foot nerves and provides a means for high spatial resolution tracking of these structures. The proposed methodology is directly applicable on standard clinical MR scanners and could be applied to systemic pathologies, such as diabetes.